SCOPE
1.1 This test method describes a laboratory procedure for determining the average nonvolatile content for one- or two-component cold liquid-applied elastomeric waterproofing membranes.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1250 – 93 (Reapproved 2005)
Standard Test Method for
Nonvolatile Content of Cold Liquid-Applied Elastomeric
Waterproofing Membranes
This standard is issued under the fixed designation C 1250; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 6. Apparatus
1.1 This test method describes a laboratory procedure for 6.1 Forced-draft Oven, controlled to 70 6 2°C (158 6
determining the average nonvolatile content for one- or two- 3.6°F).
component cold liquid-applied elastomeric waterproofing 6.2 Balance, sensitive to 0.01 g.
membranes. 6.3 Two Aluminum Weighing Dishes,57by18mm.
1.2 The values stated in SI units are to be regarded as the
7. Conditioning/Mixing
standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the 7.1 Unless otherwise specified by those authorizing the
tests, standard conditions for all tests are 23 6 2°C (73.4 6
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 3.6°F) and 50 6 5 % relative humidity.
7.2 Store all membrane materials to be tested in an un-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. opened container at standard conditions for at least 24 h before
any test specimens are prepared.
2. Referenced Documents
7.3 Follow the manufacturer’s instructions for mixing and
2.1 ASTM Standards: preparing membrane materials for testing. Thoroughly mix
C 717 Terminology of Building Seals and Sealants one-component materials before using. Mix two-component
compounds in the ratio recommended by the manufacturer.
3. Terminology
8. Procedure
3.1 Definitions—Refer toTerminology C 717 for definitions
of compound, elastomeric, and waterproofing, used in this test 8.1 For each test sample, prepare two test specimens as
method. follows:
8.1.1 Mark each aluminum weighing dish for identification.
4. Summary of Test Method
Accurately weigh each aluminum weighing dish to the nearest
4.1 This test method consists of preparing duplicate
0.01 g. Record each mass.
samples, each of known mass, and aging these samples for 72 8.1.2 Place an aluminum weighing dish on the balance and
hat70 6 2°C (158 6 3.6°F) in an air-circulating oven.
tare. Add 5.06 0.2 g of compound and spread evenly over the
interior surface area of the dish.
5. Significance and Use
8.1.3 Reweigh the test specimen, combination membrane,
5.1 This test method is used to determine the nonvolatile
and dish, and record the mass.
content of cold liquid-applied elastomeric waterproofing mem-
8.1.4 Repeat 8.
...