Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints (Metric)

ABSTRACT
This specification covers reinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients. The acceptability of the pipe, joint design, and gaskets shall be determined by the results of the tests prescribed in this specification, if and when required, and by inspection to determine whether the pipe and gaskets conform to the specification as to design and freedom from defects. Pipe manufactured in accordance with this specification shall consist of concrete, cement, fly ash, ground granulated blast furnace slag, allowable combinations of cementitious materials, a combination of Portland cement, admixtures and blends, and aggregates. The rubber compound used in the manufacture of the gasket shall be compounded from natural rubber, synthetic rubber, or a mixture of the two fabricated as prescribed in the specification. The rubber from which the gaskets are fabricated shall have the following physical properties: ultimate elongation at break; ultimate elongation at break after aging; hardness; compression set; water absorption; and ozone resistance. If a splice is used in the manufacture of the gasket, the strength shall be such that the gasket shall withstand elongation over the part of the gasket that includes the splice with no visible separation of the splice. Test specimens shall have the following test requirements: number and type of tests; external load test requirement; and hydrostatic test requirement. Rubber gasket compound tests shall include the following: tensile strength; elongation; aging; hardness; compression set; water absorption; and ozone resistance.
SCOPE
1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1.
1.2 This specification is the SI counterpart of Specification C505.
Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.  
TABLE 1 Standard Dimensions, Working Pressures, and Test Requirements   Designated Internal Diameter, mmWall Thickness,A mmWorking Pressure,B mRequired Hydrostatic Test Pressure,C kPa Minimum Three-Edge-Bearing Load, kN/linear metre 150 19927519.0 200 25927519.5 250 32927520.5 300 38927522.0 375 47927524.0 450 57927526.5 525 66927527.5 600 75927529.0
A Thinner walls are not prohibited on pipe units not over 1.22 m in length but the thickness of such walls should be not less than the internal diameter divided by 10.
B With the exception of 525 and 600-mm pipe, higher working pressures are not prohibited to be used up to a maximum of 15 m for 150 through 300-mm diameters and 12 m for 375 through 450-mm diameters. In these cases the strength of the pipe shall be increased to give minimum internal hydrostatic test pressures of at least three times the design working pressure when tested as specified in 10.4.  
C For hydrostatic test requirements, refer to 10.4.

General Information

Status
Historical
Publication Date
31-Aug-2011
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C505M-11 - Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints (Metric)
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C505M-11 - Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints (Metric)
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C505M −11
StandardSpecification for
Nonreinforced Concrete Irrigation Pipe With Rubber Gasket
1
Joints (Metric)
This standard is issued under the fixed designation C505M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D573 Test Method for Rubber—Deterioration in an Air
Oven
1.1 This specification covers nonreinforced concrete pipe
D1149 Test Methods for Rubber Deterioration—Cracking in
with rubber gasket joints to be used for the conveyance of
an Ozone Controlled Environment
irrigation water with working pressures, including hydraulic
D1415 Test Method for Rubber Property—International
transients, as shown in Table 1.
Hardness
1.2 This specification is the SI counterpart of Specification
D2240 Test Method for Rubber Property—Durometer Hard-
C505.
ness
NOTE 1—This specification is for manufacturing and purchase only and
3. Terminology
does not include requirements for bedding, backfill, installation, or field
repairs.Theowneriscautionedthathemustcorrelatefieldconditionswith
3.1 Definitions—For definitions of terms relating to con-
the characteristics of the pipe specified and provide inspection during
crete pipe, see Terminology C822.
installation.
4. Classification
2. Referenced Documents
4.1 Pipe manufactured in accordance with this specification
2
2.1 ASTM Standards:
shallbeknownas“StandardNonreinforcedConcreteIrrigation
C33 Specification for Concrete Aggregates
Pipe with Rubber Gasket Joints.”
C150 Specification for Portland Cement
5. Basis of Acceptance
C497M Test Methods for Concrete Pipe, Manhole Sections,
or Tile [Metric]
5.1 The acceptability of the pipe, joint design, and gaskets
C595 Specification for Blended Hydraulic Cements shall be determined by the results of the tests prescribed in this
C618 Specification for Coal Fly Ash and Raw or Calcined
specification, if and when required, and by inspection to
Natural Pozzolan for Use in Concrete determine whether the pipe and gaskets conform to the
C822 Terminology Relating to Concrete Pipe and Related specification as to design and freedom from defects.
Products
6. Materials and Manufacture
C989 Specification for Slag Cement for Use in Concrete and
6.1 Concrete—The concrete shall consist of cementitious
Mortars
materials, mineral aggregates, and water.
C1116 Specification for Fiber-Reinforced Concrete and
Shotcrete
6.2 Cementitious Materials:
D395 Test Methods for Rubber Property—Compression Set
6.2.1 Cement—Cement shall conform to the requirements
D412 Test Methods forVulcanized Rubber andThermoplas-
for portland cement of Specification C150 or shall be portland
tic Elastomers—Tension
blast-furnaceslagcement,orslag-modifiedportlandcement,or
D471 Test Method for Rubber Property—Effect of Liquids
portland-pozzolan cement conforming to the requirements of
Specification C595, except that the pozzolan constituent in the
Type IP portland pozzolan cement shall be fly ash.
1
This specification is under the jurisdiction of ASTM Committee C13 on
6.2.2 FlyAsh—Fly ash shall conform to the requirements of
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
Class F or Class C of Specification C618.
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)—
Current edition approved Sept. 1, 2011. Published October 2011. Originally
GGBFS shall conform to the requirements of Grade 100 or 120
approved in 1980. Last previous edition approved in 2005 as C505M – 05a. DOI:
10.1520/C0505M-11.
of Specification C989.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
6.2.4 Allowable Combinations of Cementitious Materials—
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Thecombinationofcementitiousmaterialsusedintheconcrete
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. shall be one of the following:
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C505M−11
TABLE 1 Standard Dimensions, Working Pressures, and Test
Ultimate elongation at break, min, % 350
Requirements
Ultimate elongation at break after 80
aging, min, % of
Minimum Three-
Designated Wall Required
elongation before aging
Working Edge-Bearing
A
Internal Hydrostatic Test
Thickness, Hardness, International Rubber 40 to 60
B
Pressure, m Load, kN/linear
C
Diameter, mm mm Pressure, kPa
Hardness Degrees
metre
A
or Durometer
150 19 9 275 19.0
Compression set, max, % 25
200 25 9 275 19.5
Water absorption, % 10
250 32 9 275 20.
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C505M–05a Designation: C505M – 11
Standard Specification for
Nonreinforced Concrete Irrigation Pipe With Rubber Gasket
1
Joints (Metric)
This standard is issued under the fixed designation C505M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation
water with working pressures, including hydraulic transients, as shown in Table 1.
1.2 This specification is the SI counterpart of Specification C505.
NOTE 1—Thisspecificationisformanufacturingandpurchaseonlyanddoesnotincluderequirementsforbedding,backfill,installation,orfieldrepairs.
The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.
2. Referenced Documents
2
2.1 ASTM Standards:
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile [Metric]
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
D395 Test Methods for Rubber PropertyCompression Set
D412 Test Methods for Vulcanized Rubber and Thermoplastic ElastomersTension
D471 Test Method for Rubber PropertyEffect of Liquids
D573 Test Method for RubberDeterioration in an Air Oven
D1149 Test Methods for Rubber DeteriorationCracking in an Ozone Controlled Environment
D1415 Test Method for Rubber PropertyInternational Hardness
D2240 Test Method for Rubber PropertyDurometer Hardness
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe, see Terminology C822.
4. Classification
4.1 Pipemanufacturedinaccordancewiththisspecificationshallbeknownas“StandardNonreinforcedConcreteIrrigationPipe
with Rubber Gasket Joints.”
5. Basis of Acceptance
5.1 The acceptability of the pipe, joint design, and gaskets shall be determined by the results of the tests prescribed in this
specification, if and when required, and by inspection to determine whether the pipe and gaskets conform to the specification as
to design and freedom from defects.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on Non-Reinforced
Concrete Sewer, Drain,Drain and Irrigation Pipe.
Current edition approved Dec.Sept. 1, 2005.2011. Published January 2006.October 2011. Originally approved in 1980. Last previous edition approved in 2005 as
C505M – 05a. DOI: 10.1520/C0505M-05A.10.1520/C0505M-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C505M – 11
TABLE 1 Standard Dimensions, Working Pressures, and Test
Requirements
Minimum Three-
Designated Wall Required
Working Edge-Bearing
A
Internal Thickness, Hydrostatic Test
B
Pressure, m Load, kN/linear
C
Diameter, mm mm Pressure, kPa
metre
150 19 9 275 19.0
200 25 9 275 19.5
250 32 9 275 20.5
300 38 9 275 22.0
375 47 9 275 24.0
450 57 9 275 26.5
525 66 9 275 27.5
600 75 9 275 29.0
A
Thinner walls are not prohibited on pipe units not over 1.22 m in length but the
thicknessofsuchwallsshouldbenotlessthantheinternaldiameterdividedby10.
B
With the exception of 525 and 600-mm pipe, higher working pressures are not
prohibitedtobeuseduptoamaximumof15mfor150through300-mmdiameters
and 12 m for 375 through 450-mm diameters. In these cases the strength of the
pipe shall be increased to give minimum internal hydrostatic test pressures of at
least three times the design working pressure when tested as specified in 10.4.
C
For hydrostatic test requirements, refer to 10.4.
6. Materials and Manufacture
6.1 Concrete—The concrete shall consist of cementitious materials, mineral aggregate
...

Questions, Comments and Discussion