ASTM D721-06
(Test Method)Standard Test Method for Oil Content of Petroleum Waxes
Standard Test Method for Oil Content of Petroleum Waxes
SIGNIFICANCE AND USE
The oil content of a wax may have significant effects on several of its properties, such as strength, hardness, flexibility, scuff resistance, coefficient of friction, coefficient of expansion, melting point, and oil straining. The importance of these effects may be dependent upon the ultimate use of the wax.
SCOPE
1.1 This test method covers the determination of oil in petroleum waxes having a congealing point of 30°C (86°F) or higher as determined in accordance with Test Method D 938, and containing not more than 15 % of oil.Note 1
With some types of waxes, of oil contents greater than 5%, there may be an incompatibility with MEK resulting in the formation of two liquid phases. If this occurs, the test method is not applicable to the material under test.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D721–06
Designation: 158/69(85)
Standard Test Method for
1
Oil Content of Petroleum Waxes
This standard is issued under the fixed designation D721; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* E128 Test Method for Maximum Pore Diameter and Per-
meability of Rigid Porous Filters for Laboratory Use
1.1 This test method covers the determination of oil in
2.2 Energy Institute Standards:
petroleum waxes having a congealing point of 30°C (86°F) or
4
Specification for IP Standard Thermometers
higher as determined in accordance with Test Method D938,
2
and containing not more than 15 % of oil.
3. Summary of Test Method
NOTE 1—With some types of waxes, of oil contents greater than 5%,
3.1 The sample is dissolved in methyl ethyl ketone, the
there may be an incompatibility with MEK resulting in the formation of
solution cooled to –32°C (–25°F) to precipitate the wax, and
two liquid phases. If this occurs, the test method is not applicable to the
filtered. The oil content of the filtrate is determined by
material under test.
evaporating the methyl ethyl ketone and weighing the residue.
1.2 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical 4. Significance and Use
conversions to SI units that are provided for information only
4.1 The oil content of a wax may have significant effects on
and are not considered standard.
several of its properties, such as strength, hardness, flexibility,
1.3 This standard does not purport to address all of the
scuffresistance,coefficientoffriction,coefficientofexpansion,
safety concerns, if any, associated with its use. It is the
meltingpoint,andoilstraining.Theimportanceoftheseeffects
responsibility of the user of this standard to establish appro-
may be dependent upon the ultimate use of the wax.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. 5. Apparatus
5.1 Filter Stick and Assembly, consisting of a 10-mm
2. Referenced Documents
diameter sintered glass filter stick of 10 to 15 µm maximum
3
2.1 ASTM Standards:
pore diameter as determined by the method in Appendix X1,
D938 Test Method for Congealing Point of Petroleum
provided with an air pressure inlet tube and delivery nozzle. It
Waxes, Including Petrolatum
is provided with a ground-glass joint to fit a 25 by 170-mm test
E1 Specification for ASTM Liquid-in-Glass Thermometers
tube. The dimensions for a suitable filtration assembly are
shown in Fig. 1.
1
This test method is under the jurisdiction of ASTM Committee D02 on
NOTE 2—A metallic filter stick may be employed if desired. A filter
Petroleum Products and Lubricants and is the direct responsibility of Subcommittee
1
stick made of stainless steel and having a 12.7–mm ( ⁄2-in.) disk of 10 to
D02.10.0A on Physical/Chemical Properties.
15-µm maximum pore diameter, as determined by Test Method E128, has
Current edition approved Nov. 1, 2006. Published November 2006. Originally
5
been found to be satisfactory. The metallic apparatus is inserted into a 25
approved in 1943. Last previous edition approved in 2005 as D721-05.
In the IP, this test method is under the jurisdiction of the Standardization
Committee. This test method was issued as a joint ASTM-IP tentative in 1964.
4
This test method was prepared jointly by the Technical Association of Pulp and Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,
Paper Industry and ASTM International. U.K.
5
This test method has been adopted for use by government agencies to replace The sole source of supply of a suitable metal filter stick with designated
Method 5431 of Federal Test Method Standard No. 79lb. DOI: 10.1520/D0721-06. porosity G known to the committee at this time is the Pall Corporation, 2200
2
This test method is being used by some laboratories for products of higher oil Northern Boulevard East Hills, NY 11548. A list of United Kingdom suppliers can
content. be obtained from Energy Institute, 61 New Cavendish St., London, W1G 7AR,
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or United Kingdom. If you are aware of alternative suppliers, please provide this
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM information to ASTM International Headquarters. Your comments will receive
1
Standards volume information, refer to the standard’s Document Summary page on careful consideration at a meeting of the responsible technical committee, whi
...
Questions, Comments and Discussion