Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (ISO 5167-3:2003)

ISO 5167-3:2003 specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit.
ISO 5167-3:2003 also provides background information for calculating the flow-rate and is applicable in conjunction with the requirements given in ISO 5167-1.
ISO 5167-3:2003 is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. In addition, each of the devices can only be used within specified limits of pipe size and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of nozzles and Venturi nozzles in pipe sizes less than 50 mm or more than 630 mm, or for pipe Reynolds numbers below 10 000.
ISO 5167-3:2003 deals with two types of standard nozzles, the ISA 1932 nozzle and the long radius nozzle, as well as the Venturi nozzle.
The two types of standard nozzle are fundamentally different and are described separately in ISO 5167-3:2003. The Venturi nozzle has the same upstream face as the ISA 1932 nozzle, but has a divergent section and, therefore, a different location for the downstream pressure tappings, and is described separately. This design has a lower pressure loss than a similar nozzle. For both of these nozzles and for the Venturi nozzle direct calibration experiments have been made, sufficient in number, spread and quality to enable coherent systems of application to be based on their results and coefficients to be given with certain predictable limits of uncertainty.

Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit Kreisquerschnitt - Teil 3: Düsen und Venturidüsen (ISO 5167-3:2003)

Dieser Teil von ISO 5167 legt die geometrischen Formen und Maße sowie die Anwendung (Einbau- und Betriebsbedingungen) von Düsen und Venturidüsen, die in einer voll durchströmten Rohrleitung zur Bestimmung des Durchflusses eingebaut sind, fest.
Dieser Teil von ISO 5167 enthält grundlegende Informationen für die Durchflussberechnung und ist gemeinsam mit den in ISO 5167-1 festgelegten Anforderungen anzuwenden.
Dieser Teil von ISO 5167 gilt nur für Düsen und Venturidüsen, in denen die Strömung im gesamten Messquerschnitt im Unterschallbereich liegt und wo das Fluid als einphasig betrachtet werden kann. Weiterhin kann jedes Gerät nur innerhalb festgelegter Grenzen für Rohrdurchmesser, Rohrrauheit, Durchmesserverhältnis und Reynolds-Zahl verwendet werden. Dieser Teil von ISO 5167 gilt nicht für Messungen bei pulsierenden Strömungen, für Rohrdurchmesser kleiner als 50 mm oder größer als 630 mm und für Reynolds-Zahlen unter 10 000.
Dieser Teil von ISO 5167 behandelt
a) zwei Arten von Norm-Düsen:
1) die ISA-1932-Düse );
2) die Langradius-Düse );
b)   die Venturidüse.
Die zwei Arten von Norm-Düsen sind grundsätzlich verschieden und sind in diesem Teil von ISO 5167 getrennt behandelt. Die Venturidüse hat die gleiche Stirnseite auf der Einlaufseite wie die ISA-1932-Düse, aber einen divergierenden Abschnitt und deswegen eine andere Anordnung der Druckentnahmen auf der Auslaufseite und wird deshalb getrennt beschrieben. Diese Ausführung hat einen geringeren Druckverlust als eine gleichartige Düse. Für beide Düsen und für die Venturidüse wurden direkte Kalibrierungen, ausreichend in Anzahl, Spreizung und Qualität, durchgeführt, sodass deren Ergebnisse und Koeffizienten auf ähnliche Anordnungen innerhalb bestimmter Grenzen der Messunsicherheit übertragbar sind.

Mesure de débit des fluides au moyen d'appareils déprimogènes insérés dans des conduites en charge de section circulaire - Partie 3: Tuyères et Venturi-tuyères (ISO 5167-3:2003)

L'ISO 5167-3:2003 spécifie la géométrie et le mode d'emploi (conditions d'installation et d'utilisation) de tuyères et de Venturi-tuyères insérés dans une conduite en charge dans le but de déterminer le débit du fluide s'écoulant dans cette conduite.
L'ISO 5167-3:2003 fournit également des informations de fond nécessaires au calcul de ce débit, et il convient de l'utiliser conjointement avec les exigences stipulées dans l'ISO 5167-1.
L'ISO 5167-3:2003 est applicable uniquement aux tuyères et aux Venturi-tuyères utilisés dans les limites spécifiées de diamètre de conduite et de nombre de Reynolds, dans lesquels l'écoulement reste subsonique dans tout le tronçon de mesurage contenant un fluide pouvant être considéré comme monophasique. Elle n'est pas applicable au mesurage d'un écoulement pulsé. Elle ne couvre pas l'utilisation de tuyères et de Venturi-tuyères dans des conduites de diamètre inférieur à 50 mm ou supérieur à 630 mm, ni les cas où les nombres de Reynolds rapportés à la tuyauterie sont inférieurs à 10 000.
L'ISO 5167-3:2003 traite de deux types de tuyères normalisées: de la tuyère ISA 1932 et de la tuyère à long rayon, ainsi que du Venturi-tuyère.
Les deux types de tuyères normalisées sont fondamentalement différents et sont décrits séparément dans l'ISO 5167-3:2003. Le Venturi-tuyère a la même face amont que la tuyère ISA 1932, mais, étant donné qu'il comporte un divergent et, par conséquent, un emplacement différent pour les prises de pression aval, il est également décrit séparément. Ce modèle présente une perte de pression plus basse qu'une tuyère similaire. Pour les deux types de tuyères normalisées et pour le Venturi-tuyère, des étalonnages directs ont été réalisés, en nombre suffisant, sur une gamme suffisante et avec une qualité suffisante pour permettre à des systèmes d'application cohérents de se baser sur leurs résultats et coefficients dans certaines limites prévisibles d'incertitude.

Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno v polno zapolnjen vod s krožnim prerezom – 3. del: Šobe in Venturijeve šobe (ISO 5167-3:2003)

General Information

Status
Withdrawn
Publication Date
28-Feb-2003
Withdrawal Date
08-Sep-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
09-Sep-2020

Relations

Buy Standard

Standard
EN ISO 5167-3:2004
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 5167-3:2004
01-januar-2004
1DGRPHãþD
SIST EN ISO 5167-1:1997
SIST EN ISO 5167-1:1997/A1:2001
0HUMHQMHSUHWRNDIOXLGDQDRVQRYLWODþQHUD]OLNHSRY]URþHQH]QDSUDYRYVWDYOMHQR
YSROQR]DSROQMHQYRGVNURåQLPSUHUH]RP±GHOâREHLQ9HQWXULMHYHãREH ,62

Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (ISO 5167-
3:2003)
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit
Kreisquerschnitt - Teil 3: Düsen und Venturidüsen (ISO 5167-3:2003)
Mesure de débit des fluides au moyen d'appareils déprimogenes insérés dans des
conduites en charge de section circulaire - Partie 3: Tuyeres et Venturi-tuyeres (ISO
5167-3:2003)
Ta slovenski standard je istoveten z: EN ISO 5167-3:2003
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
SIST EN ISO 5167-3:2004 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 5167-3:2004

---------------------- Page: 2 ----------------------

SIST EN ISO 5167-3:2004
EUROPEAN STANDARD
EN ISO 5167-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2003
ICS 17.120.10 Together with EN ISO 5167-1:2003,
EN ISO 5167-2:2003 and EN ISO 5167-4:2003,
supersedes EN ISO 5167-1:1995
English version
Measurement of fluid flow by means of pressure differential
devices inserted in circular cross-section conduits running full -
Part 3: Nozzles and Venturi nozzles (ISO 5167-3:2003)
Mesure de débit des fluides au moyen d'appareils Durchflussmessung von Fluiden mit Drosselgeräten in voll
déprimogènes insérés dans des conduites en charge de durchströmten Leitungen mit Kreisquerschnitt - Teil 3:
section circulaire - Partie 3: Tuyères et Venturi-tuyères Düsen und Venturidüsen (ISO 5167-3:2003)
(ISO 5167-3:2003)
This European Standard was approved by CEN on 20 February 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5167-3:2003 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 5167-3:2004
EN ISO 5167-3:2003 (E)
CORRECTED  2003-09-03
Foreword
This document (EN ISO 5167-3:2003) has been prepared by Technical Committee ISO/TC 30
"Measurement of fluid flow in closed conduits" in collaboration with CMC.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2003, and conflicting national
standards shall be withdrawn at the latest by September 2003.
This document, together with EN ISO 5167-1:2003, EN ISO 5167-2:2003 and EN ISO 5167-4:2003,
supersedes EN ISO 5167-1:1995.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the
United Kingdom.
Endorsement notice
The text of ISO 5167-3:2003 has been approved by CEN as EN ISO 5167-3:2003 without any
modifications.
NOTE Normative references to International Standards are listed in Annex ZA (normative).
2

---------------------- Page: 4 ----------------------

SIST EN ISO 5167-3:2004
EN ISO 5167-3:2003 (E)
Annex ZA
(normative)
Normative references to international publications
with their relevant European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amend
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.