EN 771-4:2003
(Main)Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units
Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units
This EN specifies the characteristics and performance requirements of autoclaved aerated concrete (AAC) masonry units for which the main intended uses are different types of loadbearing and non-loadbearing applications in all forms of walling including single leaf, cavity, partitions, retaining, basement and general use below ground level, including walling for fire protection, thermal insulation, sound insulation and chimneys.
Festlegungen für Mauersteine - Teil 4: Porenbetonsteine
Diese Europäische Norm beschreibt die Eigenschaften und Leistungsanforderungen für dampfgehärtete Porenbetonsteine, die vorwiegend in tragendem oder nichttragendem Mauerwerk in Bauwerken des Hoch- oder Tiefbaus verwendet werden. Die hierin beschriebenen Mauersteine eignen sich für alle Arten von Mauerwerk einschließlich einschaligen Mauerwerks, zweischaligen Mauerwerks, Trennwänden, Stützmauern und Fundamenten sowie für die allgemeine Verwendung unter der Erdoberfläche. Sie dienen dem Brand-, Wärme- und Schallschutz. Sie werden auch zur Herstellung von Schornsteinmauerwerk (ausgenommen bei der Auskleidung von Rauchabzügen) verwendet.
Diese Norm beschreibt die Anforderungen, z.B. an Festigkeit, Rohdichte und Maßgenauigkeit. Ferner werden die Konformitätsbewertung und die Kennzeichnung der von dieser Europäischen Norm erfassten Produkte festgelegt.
Diese Europäische Norm gilt nicht für geschosshohe Tafeln, Steine für die Auskleidung von Rauchabzügen oder für Steine zur Herstellung von feuchtesperrenden Schichten. Sie gilt nicht für Steine mit einem Wärmedämmstoff, der auf die Seiten des Steins, die Feuer ausgesetzt sein können, aufgebracht ist. Sie gibt weder genormte Größen für Porenbetonsteine noch Sollmaße und Winkel für Form- und Ergänzungssteine an. Sie enthält keine Grenzabmaße für Form- und Ergänzungssteine. Produkte zur Herstellung von feuchtesperrenden Schichten oder zur Auskleidung von Schornsteinen werden nicht behandelt.
Spécifications pour éléments de maçonnerie - Partie 4: Eléments de maçonnerie en béton cellulaire autoclavé
Cette Norme européenne spécifie les caractéristiques et les exigences de performances des blocs de maçonnerie en béton cellulaire autoclavé (BCA) dont les principales utilisations prévues sont différents types d'applications porteuses et non porteuses sous toutes les formes de murs, y compris les murs à simple ou double paroi, les cloisons, les murs de soutènement, les soubassements et les murs utilisés en sous-sol. Ils peuvent constituer une protection contre l'incendie, une isolation thermique et acoustique et un chemisage pour les conduits de fumée (excepté pour les conduits intérieurs de fumée).
Elle définit d'une part les performances relatives par exemple à la résistance, la masse volumique et les tolérances dimensionnelles et permet d'autre part d'évaluer la conformité du produit par rapport à cette Norme Européenne.
Elle inclut également les exigences de marquage des produits qui y sont traités.
Cette Norme européenne ne couvre pas les exigences concernant les panneaux hauteur d'étage, les conduits intérieurs de fumée ni les blocs comportant un isolant thermique rapporté sur les faces susceptibles d'être exposées au feu. Elle ne spécifie pas les formats normalisés des blocs en béton cellulaire autoclavé, les dimensions de fabrication courante, ni les caractéristiques angulaires des blocs de forme particulière et des blocs accessoires. Elle ne donne pas les tolérances dimensionnelles pour les blocs de forme particulière et les blocs accessoires. Elle ne couvre pas les produits destinés à servir d'assise anti-humidité ou de conduits intérieurs de fumée.
Specifikacija za zidake – 4. del: Zidaki iz avtoklaviranega celičnega betona
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2004
1DGRPHãþD
SIST EN 771-4:2000
6SHFLILNDFLMD]D]LGDNH±GHO=LGDNLL]DYWRNODYLUDQHJDFHOLþQHJDEHWRQD
Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units
Festlegungen für Mauersteine - Teil 4: Porenbetonsteine
Spécifications pour éléments de maçonnerie - Partie 4: Eléments de maçonnerie en
béton cellulaire autoclavé
Ta slovenski standard je istoveten z: EN 771-4:2003
ICS:
91.100.30
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 771-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2003
ICS 91.100.30 Supersedes EN 771-4:2000
English version
Specification for masonry units - Part 4: Autoclaved aerated
concrete masonry units
Spécifications pour éléments de maçonnerie - Partie 4: Festlegungen für Mauersteine - Teil 4: Porenbetonsteine
Eléments de maçonnerie en béton cellulaire autoclave
This European Standard was approved by CEN on 9 April 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 771-4:2003 E
worldwide for CEN national Members.
Contents Page
Foreword .4
1 Scope.5
2 Normative references.5
3 Terms and definitions.6
4 Materials and manufacture.7
4.1 General .7
4.2 Materials of manufacture.8
5 Requirements for AAC masonry units.8
5.1 General .8
5.2 Dimensions and tolerances .8
5.2.1 Dimensions .8
5.2.2 Tolerances .10
5.3 Configuration.10
5.4 Density .10
5.4.1 Gross dry density.10
5.4.2 Net dry density .11
5.4.3 Limit deviations.11
5.5 Compressive strength .11
5.6 Thermal properties.12
5.7 Durability.12
5.8 Moisture movement .12
5.9 Water vapour permeability .12
5.10 Water absorption.12
5.11 Reaction to fire .12
5.12 Shear bond strength .13
5.12.1 General .13
5.12.2 Declaration based on fixed values .13
5.12.3 Declaration based on tests .13
5.13 Flexural bond strength .13
6 Description, designation and classification of AAC masonry units.13
6.1 Description and designation.13
6.2 Classification.14
7 Marking.14
8 Evaluation of conformity .14
8.1 General .14
8.2 Initial type tests .15
8.3 Factory production control .15
8.3.1 General .15
8.3.2 Raw materials .16
8.3.3 Production process.16
8.3.4 Finished product testing .16
8.3.5 Stock control .16
Annex A (normative) Sampling for initial type testing and for independent testing of
consignments.17
A.1 General .17
A.2 Sampling procedure for an assessment of product compliance.17
A.2.1 Random sampling .17
A.2.2 Representative sampling.17
A.2.3 Dividing the sample .18
A.2.4 Number of units required for testing.18
Annex B (normative) Cutting schemes .19
B.1 Cutting scheme for producing cubes or prisms from AAC masonry units in order
to determine the dry density. .19
B.2 Cutting scheme for producing cubes from AAC masonry units in order to
determine compressive strength.20
Annex ZA (informative) Clauses of this European Standard addressing the provisions of
the EU Construction Products Directive .21
Foreword
This document (EN 771-4:2003) has been prepared by Technical Committee CEN/TC 125 "Masonry",
the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by January 2004, and conflicting national standards
shall be withdrawn at the latest by April 2005.
This document has been prepared under a mandate given to CEN by the European Commission and
the European Free Trade Association and supports the essential requirements of the EU Construction
Products Directive (89/106/EEC).
For relationship with EU Directive(89/106/EEC), see informative Annex ZA which is an integral part of
this standard.
It also takes into account the general rules for unreinforced and reinforced masonry in Eurocode 6.
The Annexes A and B of this European Standard are normative.
This European Standard replaces EN 771-4:2000.
EN 771, Specification for masonry units consists of:
Part 1: Clay masonry units.
Part 2: Calcium silicate masonry units.
Part 3: Aggregate concrete masonry units (Dense and light-weight aggregates).
Part 4: Autoclaved aerated concrete masonry units.
Part 5: Manufactured stone masonry units.
Part 6: Natural stone masonry units.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg,
Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the United
Kingdom.
1 Scope
This European Standard specifies the characteristics and performance requirements of autoclaved
aerated concrete (AAC) masonry units for which the main intended uses are different types of load
bearing and non-load bearing applications in all forms of walling including single leaf, cavity,
partitions, retaining, basement and general use below ground level, including walling for fire
protection, thermal insulation, sound insulation and the fabric of chimneys (excluding chimney flue
units).
It defines the performance related to e.g. strength, density, dimensional accuracy etc. and provides
for the evaluation of conformity of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not cover the requirements for storey height panels, flue linings and
masonry units with an incorporated thermal insulation material bonded to the faces of the unit
susceptible to be exposed to fire. It does not specify standard sizes for autoclaved aerated concrete
units nor standard work dimensions and angles of specially shaped and accessory units. It does not
give permissible deviations for specially shaped and accessory units. It does not cover products
intended for use as a damp proof course or the lining of a chimney.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
EN 680, Determination of the drying shrinkage of autoclaved aerated concrete
EN 772-1:2000, Methods of test for masonry units — Part 1: Determination of compressive strength
EN 772-10, Methods of test for masonry units — Part 10: Determination of moisture content of
calcium silicate and autoclaved aerated concrete units
EN 772-11, Methods of test for masonry units — Part 11: Determination of water absorption of
aggregate concrete, manufactured stone and natural stone masonry units due to capillary action and
the initial rate of water absorption of clay masonry units
EN 772-13, Methods of test for masonry units — Part 13: Determination of net and gross dry density
of masonry units (except for natural stone)
EN 772-16, Methods of test for masonry units — Part 16: Determination of dimensions
EN 998-2:2001, Specification for mortar for masonry — Part 2: Masonry mortar
EN 1052-3, Methods of test for masonry — Part 3: Determination of initial shear strength
EN 1745, Masonry and masonry products — Methods for determining design thermal values
EN 13501-1, Fire classification of construction products and building elements —
Part 1: Classification using test data from reaction to fire tests
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.