Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - jacketed or screened and jacketed - Part 003: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket without screen - UV laser printable - Product standard

This European standard specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between – 65 °C and 135 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These jacketed cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung, XLETFE-Familie, ummantelt oder geschirmt und ummantelt - Teil 003: Kupfer verzinnt, Betriebstemperaturen zwischen -65 °C und 135 °C, einfach extrudierte Isolierung für offene Anwendungen, ummantelt ohne Schirm, UV-Laser bedruckbar - Produktnorm

Diese Europäische Norm legt die Eigenschaften von elektrischen Leitungen mit UV-Laser bedruckbarem
Mantel, mit Leiter aus Kupfer verzinnt, aus der XLETFE-Familie (quervernetztes Ethylen-Tetrafluorethylen-Co-
Polymer) zur Verwendung in elektrischen Bordnetzen von Luftfahrzeugen für Betriebstemperaturen zwischen
−65 °C und 135 °C und Spannungen bis 600 V (Effektivwert) und Frequenzen bis 2 000 Hz fest. Wenn der
Mantel vorhanden ist, sind diese ummantelten Leitungen ohne zusätzlichen Schutz für die Verlegung in Luftfahrzeugzellen
geeignet. Ist der Mantel abisoliert, können die Adern einen zusätzlichen Schutz benötigen. Im
Schiedsfall zwischen dieser Norm und anderen Referenzdokumenten müssen die Anforderungen dieser Norm
Vorrang haben.

Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 003: Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil simple isolé pour applications externes, gainé et non blindé - Marquable au laser UV - Norme de produit

La présente Norme Européenne spécifie les caractéristiques des conducteurs en cuivre étamé gainé,
marquable au laser UV de la famille des Copolymère Ethylène, Tétra Fluoro Ethylène Réticulé (XLETFE)
utilisés dans les systèmes de bord des aéronefs à une température de fonctionnement comprise entre – 65 °C
et 135 °C, à une tension n’excédant pas 600 V eff. et une fréquence de 2 000 Hz. Ces câbles gainés sont
utilisables en cellule sans protection supplémentaire quand la gaine est présente. Quand la gaine est
dénudée le conducteur peut avoir une protection additionnelle. En cas de conflit entre cette norme et un autre
document de référence, les exigences de cette norme doivent être prises en première considération.

Aeronavtika - Eno- in večžilni električni kabli za splošne namene - Družina XLETFE - oplaščeni ali zaslonjeni in oplaščeni - 003. del: Pocinjeni baker - Obratovalne temperature med –65 °C in 135 °C - Enojno ekstrudirana izolacija za zunanjo uporabo, s plaščem brez zaslona - Možnost UV-laserskega tiskanja - Standard za izdelek

Ta evropski standard določa značilnosti električnih kablov iz družine zamreženega etilen-tetrafluoretilen kopolimera (XLETFE), s prevodnikom iz pocinjenega bakra, s plaščem z možnostjo UV-laserskega potiska za uporabo v električnih sistemih na krovu zračnega plovila pri obratovalnih temperaturah med -65 °C in 135 °C, delujočih pri napetostih, ki ne presegajo 600 V r.m.s, in frekvencah, ki ne presegajo 2000 Hz. Ti oplaščeni kabli so primerni za uporabo v ogrodjih zrakoplovov brez dodatne zaščite, če imajo plašč. Če je plašč olupljen, je lahko potrebna dodatna zaščita jeder. Ob neskladju med tem standardom in drugimi referenčnimi dokumenti imajo zahteve tega standarda prednost.

General Information

Status
Withdrawn
Publication Date
18-Oct-2011
Withdrawal Date
27-Aug-2019
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
28-Aug-2019

Relations

Buy Standard

Standard
EN 4612-003:2011
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.L]GHOHNLuft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 003: Kupfer verzinnt, Betriebstemperaturen zwischen - 65 °C und 135 °C - Einfach extrudierte Isolierung für externe Verwendung, mit Mantel ohne Schirm - UV-Laser bedruckbar - ProduktnormSérie aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 003 : Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil simple isolé pour applications externes, gainé et non blindé - Marquable au laser UV - Norme de produitAerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - jacketed or screened and jacketed - Part 003: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket without screen - UV laser printable - Product standard49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4612-003:2011SIST EN 4612-003:2011en01-december-2011SIST EN 4612-003:2011SLOVENSKI
STANDARD



SIST EN 4612-003:2011



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4612-003
October 2011 ICS 49.060 English Version
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - jacketed or screened and jacketed - Part 003: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket without screen - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 003: Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil simple isolé pour applications externes, gainé et non blindé - Marquable au laser UV - Norme de produit
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 003: Kupfer verzinnt, Betriebstemperaturen zwischen - 65 °C und 135 °C - Einfach extrudierte Isolierung für externe Verwendung, mit Mantel ohne Schirm - UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 15 July 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4612-003:2011: ESIST EN 4612-003:2011



EN 4612-003:2011 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Terms, definitions and symbols .44Materials and construction .45Required characteristics .56Quality assurance .87Designation .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.