Thermal insulation products for buildings - Factory made products of extruded polystyrene foam (XPS) - Specification

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards, which are also available with special edge and surface treatment (tongue & groove, shiplap etc.). The standard also covers multilayered insulation boards and composite insulation boards in which extruded polystyrene foam is the main insulant. The standard describes product characteristics and includes procedures for testing, marking and labelling.

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum (XPS) - Spezifikation

Diese Europäische Norm legt die Anforderungen für werkmäßig hergestellte extrudierte Polystyrolschaumprodukte mit oder ohne Kaschierung fest, die als Wärmedämmstoffe im Bauwesen verwendet werden. Die Produkte werden in Form von Platten hergestellt. Sie sind ebenso mit besonderer Klantenoder Oberflächenausbildung verfügbar (Nut und Federausbildung, Stufenfalz usw.) . Diese Norm beschreibt die Stoffeigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung. In dieser Norm beschriebene Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht-Verbundplatten angewendet; die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt. Diese Norm gilt auch für Produkte, die mehrlagig hergestellt werden. Diese Norm legt keine Anforderungsniveaus für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte Anwendungen benötigte Anforderungen können Regelwerken oder übereinstimmenden Normen entnommen werden. Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger ist als 0,25 m² K/W oder deren Nennwert der Wärmeleitfähigkeit größer ist als 0,060 W (m . K) bei 10°C Mitteltemperatur. Diese Norm gilt nicht für in situ-Dämmstoffe und für P¨rodukte, die zur Dämmung von haustechnischen oder betriebstechnischen Anlagen bestimmt sind, und Produkte, die zur Schalldämmung bestimmt sind.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse de polystyrène extrudé (XPS) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en mousse de polystyrène extrudé, avec ou sans parements ou revêtements, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux qui sont également disponibles avec traitement spécial de leurs chants et surfaces (tenon et mortaise, feuillure, etc.).
La présente norme décrit les caractéristiques du produit et inclut les procédures d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
Les produits du domaine d'application de la présente norme sont également  utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; la performance des systèmes dans lesquels entrent ces produits n'est pas définie. La norme porte également sur les panneaux multicouches d'isolation.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,25 m2K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,060 W/(m×K), ne sont pas du domaine d'application de la présente norme.
Les produits d'isolation mis en ¿uvre in situ, ceux destinés à être utilisés pour l'isolation des équipements du bâtiment et des installations industrielles ou ceux destinés à l'isolation acoustique ne sont pas du domaine d'application de la présente norme.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekstrudiranega polistirena (XPS) - Specifikacija

General Information

Status
Withdrawn
Publication Date
22-May-2001
Withdrawal Date
25-Nov-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
26-Nov-2008
Completion Date
26-Nov-2008

Relations

Buy Standard

Standard
EN 13164:2002
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermal insulation products for buildings - Factory made products of extruded polystyrene foam (XPS) - SpecificationToplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekstrudiranega polistirena (XPS) - SpecifikacijaProduits isolants thermiques pour le bâtiment - Produits manufacturés en mousse de polystyrene extrudé (XPS) - SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus extrudiertem Polystyrolschaum (XPS) - Spezifikation91.100.60Thermal and sound insulating materialsICS:SIST EN 13164:2002enTa slovenski standard je istoveten z:EN 13164:200101-marec-2002SIST EN 13164:2002SLOVENSKI
STANDARD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13164May 2001ICS 91.100.60English versionThermal insulation products for buildings - Factory madeproducts of extruded polystyrene foam (XPS) - SpecificationProduits isolants thermiques pour le bâtiment - Produitsmanufacturés en mousse de polystyrène extrudé (XPS) -SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellteProdukte aus extrudiertem Polystyrolschaum (XPS) -SpezifikationThis European Standard was approved by CEN on 16 April 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2001 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13164:2001 E



Page 2EN 13164:2001ContentsPageForeword.41Scope.52Normative references.53Terms, definitions, symbols, units, abbreviatiated terms.64Requirements.85Test methods.136Designation code.167Evaluation of Conformity.168Marking and labelling.17Annex A (normative)
Determination of the declared values of thermal resistanceand thermal conductivity.18Annex B (normative)
Factory Production Control.20Annex C (normative)
Determination of the aged values of thermal resistance andthermal conductivity.23Annex D (informativ)
Additional Properties.27Annex E (Informative)
Plan for cutting test specimen.29Annex Z.A (informative)
Clauses of this European Standard adressing theprovisions of the EU Construction Products Directive.31TablesTable 1 – Tolerances of length, width, squareness and flatness.9Table 2 – Classes for thickness tolerances.10Table 3 – Levels for compressive stress or compressive strength.10Table 4 – Levels for deformation under specified compressive load and temperature conditions11Table 5 – Levels for tensile strength, perpendicular to faces.11Table 6 – Levels for long term water absorption by total immersion.12Table 7 – Levels for long term water absorption by diffusion.13Table 8 – Levels for freeze-thaw resistance.13Table 9
– Test methods, test specimens and conditions.15Table A.1 – Values of k for one sided 90% tolerance interval with a confidence level of 90%.19Table B.1 – Minimum product testing frequencies.20Table B.2 – Minimum product testing frequencies for the reaction to fire characteristics.21Table D.1 – Test methods, test specimens, conditions
and minimum testing frequencies.28Table ZA.1 – Relevant clauses.32Table ZA.2.1 – Systems of attestation of conformity of factory made products forany intended use.33



Page 3EN 13164:2001Table ZA.2.2 – Systems of attestation of conformity of factory made products for uses subject toregulations on reaction to fire.33Table ZA.3 – Example CE marking information.35



Page 4EN 13164:2001ForewordThis European Standard has been prepared by Technical Committee CEN/TC 88 "Thermal insulating materialsand products", the secretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical textor by endorsement, at the latest by November 2001, and conflicting national standards shall be withdrawn at thelatest by March 2003.This European Standard has been prepared under a mandate given to CEN by the European Commission andthe European Free Trade Association, and supports essential requirements of EU Directive(s).For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this standard.This European Standard contains six annexes :Annex A
(normative)Determination of the declared values of thermal resistanceand thermal conductivity;Annex B
(normative)Factory production control;Annex C
(normative)Determination of aged values of thermal resistance andthermal conductivity;Annex D (informative)Additional properties;Annex E (informative)Plan for cutting test specimen;Annex ZA
(informative)Clauses of this European Standard addressing theprovisions of the EU Construction Products Directive;This European Standard is one of a series of standards for insulating products used in buildings, but thisstandard may be used in other areas where appropriate.In pursuance of resolution BT 20/1993 revised, CEN/TC88 have proposed defining the standards listed belowas a package of European Standards, setting (21 months after availability) as the date of withdrawal (dow) ofnational standards which conflict with the European Standards of this package.The package of standards comprises the following group of interrelated standards for the specifications offactory made thermal insulation products; all of which come within the scope of CEN/TC88:EN 13162, Thermal insulation products for buildings – Factory made mineral wool (MW) products –Specification.EN 13163, Thermal insulation products for buildings – Factory made products of expandedpolystyrene (EPS) – Specification.EN 13164, Thermal insulation products for buildings – Factory made products of extruded polystyrenefoam (XPS) – Specification.EN 13165, Thermal insulation products for buildings – Factory made rigid polyurethane foam(PUR) products –Specification.EN 13166, Thermal insulation products for buildings – Factory made products of phenolic foam (PF) –Specification.EN 13167, Thermal insulation products for buildings – Factory made cellular glass (CG) products – Specification.EN 13168, Thermal insulation products for buildings – Factory made wood wool (WW) products –Specification.



Page 5EN 13164:2001EN 13169, Thermal insulation products for buildings – Factory made products of expanded perlite (EPB) –Specification.EN 13170, Thermal insulation products for buildings – Factory made products of expanded cork (ICB) –Specification.EN 13171, Thermal insulation products for buildings – Factory made wood fibre (WF) products
–Specification.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark,Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.1ScopeThis European Standard specifies the requirements for factory made products of extruded polystyrene foam,with or without facings or coatings, which are used for thermal insulation of buildings. The products aremanufactured in the form of boards, which are also available with special edge and surface treatment (tongue &grooves, shiplap etc.).This standard describes product characteristics and includes procedures for testing, evaluation of conformity,marking and labelling.Products covered by this standard are also used in prefabricated thermal insulating systems and compositepanels; the performance of systems incorporating these products is not covered. The standard also coversmultilayered insulation boards.The standard does not specify the required level of a given property to be achieved by a product to demonstratefitness for purpose in a particular application. The levels required for a given application are to be found inregulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,25 m²K/W or a declared thermal conductivity greaterthan 0,060 W/(mK) at 10 C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation ofbuilding equipment and industrial installations or products intended for acoustic insulation.2Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text and the publications are listed hereafter. Fordated references subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).EN 822, Thermal insulating products for building applications - Determination of length and width.EN 823, Thermal insulating products for building applications - Determination of thickness.EN 824, Thermal insulating products for building applications - Determination of squareness.EN 825, Thermal insulating products for building applications - Determination of flatness.EN 826, Thermal insulating products for building applications - Determination of compression behaviour.prEN ISO 1182, Reaction to fire tests for building products – Non-combustibility test (ISO/DIS 1182:1998).EN 1604, Thermal insulating products for building applications - Determination of dimensional stability underspecified temperature and humidity conditions.



Page 6EN 13164:2001EN 1605, Thermal insulating products for building applications - Determination of deformation under specifiedcompressive load and temperature condition.EN 1606, Thermal insulating products for building applications - Determination of compressive creep.EN 1607, Thermal insulating products for building applications - Determination of tensile strength perpendicularto faces.prEN ISO 1716, Reaction to fire tests for building products – Determination of calorific value (ISO/DIS1716:1998).prEN ISO 9229, Thermal insulation – Definitions of terms (ISO/DIS 9229:1997).prEN ISO 11925-2, Reaction to fire tests for building products – Part 2: Ignitability when subjected to directimpingement of flame (ISO/DIS 11925-2:1998).EN 12086:1997, Thermal insulating products for building applications - Determination of water vapourtransmission properties.EN 12087, Thermal insulating products for building applications - Determination of long term water absorptionby immersion.EN 12088, Thermal insulating products for building applications - Determination of long term water absorptionby diffusion.EN 12091, Thermal insulating products for building applications - Determination of freeze-thaw resistance.prEN 12667, Thermal performance of building materials and products - Determination of thermal resistance bymeans of guarded hotplate and heat flow meter methods – Products of high and medium thermal resistance.EN 12939, Thermal performance of building materials and products – Determination of thermal resistanceby means of guarded hot plate and heat flow meter methods – Thick products of high and medium thermalresistance.prEN 13172:2001, Thermal insulating products – Evaluation of conformity.prEN 13501-1, Fire classification of construction products and building elements – Part 1: Classificationusing test data from reaction to fire test.prEN 13820, Thermal insulating products for building applications – Determination of organic content.prEN 13823, Reaction to fire tests for building products – Building products excluding floorings exposed tothe thermal attack by a single burning item.ISO 12491, Statistical methods for quality control of building materials and components.3Terms, definitions, symbols, units, abbreviatiated terms3.1Terms and definitionsFor the purposes of this standard, the following definitions apply.3.1.1Terms and definitions as given in prEN ISO 92293.1.1.1 extruded polystyrene foamrigid cellular plastics insulation material expanded and extruded with or without a skin, from polystyrene or oneof its copolymers and which has a closed cell structure



Page 7EN 13164:20013.1.1.2 boardrigid or semi-rigid insulation product of rectangular shape and cross section in which the thickness is uniformand substantially smaller than the other dimensions3.1.2Additional definitions3.1.2.1 levelthe given value which is the upper or lower limit of a requirement. The level is given by the declared value of thecharacteristic concerned3.1.2.2 classa combination of two levels of the same property between which the performance shall fall3.2 Symbols, units and abbreviated termsSymbols and units used in this standard:b is the widthmmd is the thickness mmdNis the nominal thickness of the productmmdSis the
thickness of test specimenmmb is the relative change in width%d is the relative change in thickness%l is the relative change in length%ctis the compressive creep%tis the total relative thickness reduction%1is the relative deformation after step A%2is the relative deformation after step B%kis a factor related to the number of test results available –lis the lengthmm90/90is the 90 % fractile with a confidence level of 90 % for the thermal conductivityW/(mK)90/90, 60dis the 90 % fractile with a confidence level of 90 % for the thermal conductivityW/(mK)of foam at 60 days90/90>60dis the 90 % fractile with a confidence level of 90 % for the thermal conductivityW/(mK)of foam older than 60 daysDis the declared thermal conductivityW/(mK)Iis one test result of thermal conductivityW/(mK)meanis the mean thermal conductivityW/(mK)mean, ais the mean thermal conductivity of aged valuesW/(mK)mean, 60d is the mean thermal conductivity of values for 60 days old foamW/(mK)> 60d is the measured value of the thermal conductivity of foam older than 60 daysW/(mK)is the water vapour diffusion resistance factor--nis the number of test results–R90/90is the 90 % fractile with a confidence level of 90 % for the thermal resistancem2K/WR90/90, 60dis the 90 % fractile with a confidence level of 90 % for the thermal resistancem2K/Wof foam at 60 daysR90/90>60dis the 90 % fractile with a confidence level of 90 % for the thermal resistancem2K/Wof foam older than 60 daysRDis the declared thermal resistancem2K/WRIis one test result of thermal resistancem2K/WRmeanis the mean thermal resistancem2K/WSbis the deviation from squareness on width or lengthmm/m



Page 8EN 13164:2001Smax
is the deviation from flatnessmmsRis the estimate of the standard deviation of the thermal resistancem2K/Wsis the estimate of the standard deviation of the thermal conductivityW/(mK)sais the estimate of the standard deviation of the aged thermal conductivityW/(mK)siis the estimate of the standard deviation of the initial thermal conductivitywithin 90 days of productionW/(mK)10is the compressive stress at 10% deformationkPacis the declared compressive stress kPamis the compressive strengthkPamtis the tensile strength perpendicular to faceskPaWdVis the water absorption by diffusion %Wltis the long term water pick up by total immersion%WVis the water absorption by diffusion and by freeze-thaw%Zis the water vapour resistancem2hPa/mgCC(i1/i2/y)cis the symbol of the declared level for compressive creepCS(10\Y)xis the symbol of the declared level for compressive stress or strengthDLT(1)5 is the symbol of the declared level of deformation under specified compressive load andtemperature at conditions set 1 with a maximum of 5 %
deformationDLT(2)5 is the symbol of the declared level of deformation under specified compressive load andtemperature at conditions set 2 with a maximum of 5 % deformationDS(T+)is the symbol of the declared value for dimensional stability at specified
temperatureDS(TH)is the symbol of the declared value for dimensional stability under specified temperature andhumidityFTis the symbol of the declared level for freeze thaw resistanceMUis the symbol of the declared level for water vapour diffusion resistance factorTis the symbol of the declared class for thickness tolerancesTRis the symbol of the declared level for tensile strength perpendicular to facesWD(V)is the symbol of the declared level for water absorption by diffusionWL(T)is the symbol of the declared level for long term water absorption by total immersionZis the symbol of the declared value for water vapour resistanceAbbreviated terms used in this standard:XPSis eXtruded PolyStyrene foamITT is Initial Type Testing4Requirements4.1GeneralProduct properties shall be assessed in accordance with clause 5. To comply with this standard, products shallmeet the requirements of 4.2, and the requirements of 4.3 as appropriate.NOTE
Information on additional properties is given in annex D.One test result for a product property is the average of the measured values on the number of test specimensgiven in Table 9.4.2For all applications4.2.1Thermal resistance and thermal conductivityThe thermal resistance and thermal conductivity shall be based upon measurements carried out in accordancewith prEN 12667 or EN 12939 for thick products.The thermal resistance and thermal conductivity shall be determined in accordance with annex A and annex Cand declared by the manufacturer according to the following:– the reference mean temperature shall be 10 °C;



Page 9EN 13164:2001– the measured values shall be expressed with three significant figures;– the thermal resistance, RD, shall always be declared. The thermal conductivity, D, shall be declaredwhere possible;– the declared thermal resistance, RD, and the declared thermal conductivity, D, shall be given as limitvalues representing at least 90 % of the production, determined with a confidence level of 90 %;– the value of thermal conductivity, 90/90, shall be rounded upwards to the nearest 0,001 W/(mK) anddeclared as D in levels with steps of 0,001 W/(mK);– the declared thermal resistance, RD, shall be calculated from the nominal thickness, d N ,and thecorresponding declared thermal conductivity value, 90/90;– the value of thermal resistance, R90/90, when calculated from the nominal thickness , d N , and thecorresponding thermal conductivity, 90/90, shall be rounded downwards to the nearest 0,05 m²K/W, anddeclared as RD in levels with steps of 0,05 m²K/W;– the value of, R90/90, for those products for which only the thermal resistance is measured directly, shall berounded downwards to the nearest 0,05 m²K/W and declared as RD in levels with steps of
0,05 m²K/W.4.2.2
Length, width, squareness, flatnessLength, l, and width, b, shall be determined in accordance with EN 822, the squarenesses on length and width,Sb, in accordance with EN 824, and the flatness, Smax, in accordance with EN 825. No test result shall deviatefrom the nominal values by more than the tolerances given in Table 1.Table 1 – Tolerances of length, width, squareness and flatnessTolerancesNominallength or widthLength or widthSquareness onlength and widthFlatnessmmmmSbmm/mSmaxmmless than 10001000 to 2000> 2000 to 4000> 4000±
8± 10± 10± 105555
7,014,028,035,04.2.3ThicknessThickness, d, shall be determined in accordance with EN 823. No test result shall deviate from the nominalthickness, d N , by more than the tolerances given in Table 2 for the lablled class.



Page 10EN 13164:2001Table 2 – Classes for thickness tolerances classTolerancesmmThicknessmmT1-2-2-2+2+3+8< 5050
dN
120> 120T2-1,5-1,5-1,5+1,5+1,5+1,5< 5050
dN
120> 120T3-1-1-1+1+1+1< 5050
dN
120> 1204.2.4 Dimensional stability under specified temperature and humidity conditionsDimensional stability under specified temperature and humidity conditions shall be determined in accordancewith EN 1604. The test shall be carried out after storage for 48 h at (23 ± 2) °C and (90 ± 5) % relative humidity.The relative changes in length, l, in width, b, and in thickness, d, shall not exceed 2 %. This test shall notbe performed when the more severe test, described in 4.3.2.2 is used.4.2.5Compressive stress or compressive strengthThe compressive stress at 10 % deformation, 10, or the compressive strength, m, shall be determined inaccordance with EN 826. No test result for either the compressive stress at 10 % deformation, 10, or thecompressive strength, m, whichever is the greatest, shall be lower than the values given in Table 3 for thedeclared level.Table 3 – Levels for compressive stress or compressive strengthLevelRequirementkPaCS(10\Y)100>100CS(10\Y)200 200CS(10\Y)250 250CS(10\Y)300 300CS(10\Y)400 400CS(10\Y)500 500CS(10\Y)600 600CS(10\Y)700 700CS(10\Y)800 800CS(10\Y)1000 10004.2.6 Reaction to fireReaction to fire classification (Euroclasses) shall be determined in accordance with prEN 13501-1.



Page 11EN 13164:20014.3For specific applications4.3.1
GeneralIf there is no requirement for a property described in 4.3 for a product in use, then the property does not need to bedetermined and declared by the manufacturer.4.3.2
Dimensional stability under specified conditions4.3.2.1
Dimensional stability at specified temperatureDimensional stability at specified temperature shall be determined in accordance with EN 1604. The test shallbe carried out after storage for 48 h at (70 ± 2) °C. The relative changes in length, l,, in width, b,
and inthickness, d,
shall not exceed 5 %.4.3.2.2
Dimensional stability under specified temperature and humidity conditionsDimensional stability under specified temperature and humidity conditions shall be determined in accordancewith EN 1604. The test shall be carried out after storage for 48 h at (70 ± 2) °C and (90
5) % relative humidity.The relative changes in length, l, in width, b,
and in thickness, d, shall not exceed 5 %.4.3.2.3Deformation under specified compressive load and temperature conditionsDeformation under specified compressive load and temperature conditions shall be determined in accordancewith EN 1605. For each test condition the difference between the relevant deformation, 1 , after step A and, 2 ,after step B as described in EN 1605 shall not exceed the values given in Table 4 for the declared level.Table 4 – Levels for deformation under specified compressive load and temperature conditionsLevel
Test conditionsRequirement%DLT(1)5load : 20 kPatemperature : (80 ± 1) °Ctime :
(48
1) h. 5DLT(2)5load : 40 kPatemperature : (70 ± 1) °Ctime :
(168
1) h. 54.3.3Tensile strength perpendicular to facesTensile strength perpendicular to faces, mt, shall be determined in accordance with EN 1607. No test resultshall be less than the value given in Table 5 for the declared level.Table 5 – Levels for tensile strength, perpendicular to facesLevelRequirementkPaTR100 100TR200 200TR400 400TR600 600TR900 900



Page 12EN 13164:20014.3.4Compressive creepCompressive creep,
ct , and total thickness reduction, t, shall be determined after at least one hundred twentytwo days of testing at a declared compressive stress, c, given in steps of at least 1 kPa, and the resultsextrapolated thirty times, corresponding to ten years, to obtain the declared levels in accordance with EN 1606.Tests shall be done with samples that do not exceed the compressive stress or compressive strength accordingto the level of Table 3 by more than 10 %. Compressive creep shall be declared in levels , i2
and the totalthickness reduction shall be declared in levels, i1, with steps of 0,5 % at the declared stress. No test result shallexceed the declared levels at the declared stress.NOTE 1
For building applications a total thickness reduction ,
t, of 2% and an extrapolation time of 50 years
are generallyrequired.NOTE 2
Examples for declaration of levels for compressive creep.LevelTest timedaysExtrapolation timeYearsDeclared stresskPaRequirement%CC(i1/i2%, 10)c12210ci1/ i2CC(i1/ i2 %, 25)c30425ci1/ i2CC(i1/ i2 %, 50)c60850ci1/ i2 NOTE 3
Referring to the designation code CC(i1/i2/y)c, according to clause 6, a declared level CC(2/1,5/50)100, forexample, indicates a value not exceeding 1,5 % for compressive creep and 2 % for total thickness reduction afterextrapolation at 50 years (i.e. 30 times six hundered eight days of testing) under a declared stress of 100 kPa.4.3.5
Point loadThe effects of foot traffic shall be assessed by means of determination of the compressive stress or thecompressive strength in accordance with EN 826, see 4.2.5.4.3.6
Water absorption4.3.6.1
Long term water absorption by immersionWater absorption by total immersion, Wlt , shall be determined in accordance with EN 12087 method 2A. No testresult shall be higher than the value given in Table 6, for the declared level.Table 6 –Levels for long term water absorption by total immersionLevelRequirement%WL(T)3 3WL(T)1,5 1,5WL(T)0,7 0,74.3.6.2
Long term water absorption by diffusionWater absorption by diffusion, WdV, shall determined in accordance with EN 12088. No test result shall behigher than the value given in Table 7 for the declared level.



Page 13EN 13164:2001Table 7 – Levels for long term water absorption by diffusionLevelRequirement a%dN = 50 mmdN = 100 mmdN = 200 mmWD(V)5 5 3
1,5WD(V)3
3
1,5
0,5a
Values between thicknesses to be interpolated4.3.7
Freeze-thaw resistanceFreeze-thaw resistance shall be determined in accordance with EN 12091 using the test specimen from 4.3.6.2.The water absorption, WV, shall be not higher than the value given in Table 8 for the declared level.Table 8 –
Levels for freeze-thaw resistanceLevelRequirement%FT1 2FT2 1After the freeze - thaw test the reduction in compressive stress at 10 % deformation, 10, or the compressivestrength, m,
of the dry specimen, when tested in accordance with EN 826 shall not exceed 10 % of the initialvalue.4.3.8 Water vapour transmissionWater vapour transmission properties shall be determined in accordance with EN 12086, and declared as thewater vapour diffusion resistance factor, , for homogeneous products and as the water vapour resistance, Z,for faced or non-homogeneous products. No test result of , , shall be less than the declared level , MU,choosen from the following levels : 50, 80, 100, 150, 200, 250, 300. If , Z, is declared, no test result shall be lessthan the declared value.4.3.9 Release of dangerous substancesNOTE
See annex ZA5Test methods5.1SamplingTest specimens shall be taken from the same sample, with a total area of not less than one board, sufficient tocover the needed tests. Note
If appropriate, test specimens should be cut according to the cutting plan given in annex E.5.2 ConditioningNo special conditioning of test specimens is needed unless otherwise specified in this standard. In case ofdispute the test specimens shall stored at (23
2) C and (50
5) % relative humidity for at least 6 h prior totesting unless otherwise s
...