This document provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804:2012+A2:20191) for factory made and in situ thermal insulation products.
Complementary to EN 15804:2012+A2:20191, the PCR described in this document:
-   specify the declared unit to be used;
-   define the system boundaries for thermal insulation products;
-   specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules.
These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.

  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides a vocabulary of terms used in the field of thermal insulation that covers materials, products, components and applications. Some of the terms can have a different meaning when used in other industries or applications.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made expanded polystyrene products, with or without rigid or flexible facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware (flat, tapered, tongue and grooves, shiplap, profiled etc.).
Products covered by this standard are also used for sound insulation and in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required class or level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m²⋅K/W or a declared thermal conductivity at 10 °C greater than 0,060 W/(m⋅K) are not covered by this standard.
This standard does not cover in-situ insulation products (covered by EN 16025-1 and -2), products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14309), products intended to be used in civil engineering applications (covered by EN 14933) and products intended to be used in beam and block systems in floors (covered by EN 15037-4).

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,40 m2⋅K/W or a declared thermal conductivity greater than 0,050 W/(m⋅K) at 10 °C are not covered by this standard.
This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 [3]).

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made polyethylene foam (PEF) products, with or without facing or coating, which are used for thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,5 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this European Standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14313). Further excluded are non-foamed materials such as bubble films, foils etc.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.).
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m²K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 C are not covered by this standard.
This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14307), or civil engineering applications (covered by EN 14934).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards with or without facings or coatings.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W, or a declared thermal conductivity greater than 0,060 W/(mK), at 10 °C, are not covered by this European Standard.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made wood wool (WW) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels and classes required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2K/W or a declared thermal conductivity greater than 0,100 W/(mK) at 10 °C are not covered by this standard.
This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,50 m2K/W or a declared thermal conductivity greater than 0,065 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14305).

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made expanded perlite board products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards, multi-layered insulation or composite insulation products.
This standard also covers composite insulation products (see Annex E).
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2K/W or a declared thermal conductivity greater than 0,070 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made wood fibre (WF) products, with or without facings or coatings, which are used for the thermal insulation of buildings ). The products are manufactured in the form of rolls, batts, felts, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,20 m2K/W or a declared thermal conductivity greater than 0,070 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-08-04 NUP: Through decision BT C141/2021, BT approved the delition of the WI.
20191129 - ECB: FV delayed due to negative assessment
DOW = DAV + 21 months

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

  • Draft
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-08-04 NUP: Through decision BT C141/2021, BT approved the delition of the WI.
20191129 - ECB: FV delayed due to negative assessment
DOW = DAV + 21 months

  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-08-04 NUP: Through decision BT C141/2021, BT approved the delition of the WI.
20191129 - ECB: FV delayed due to negative assessment
DOW = DAV + 21 months

  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies the requirements for factory made composite products to be used for thermal insulation of buildings, such as composite insulation products with at least two different thermal insulation layers and with or without facings or coatings, and composite products with thermal insulation layer/s bonded to additional external layer/s of non insulation products.  
Products defined by standards EN 13162 to 13171 and prEN 16069 shall be used for the thermal insulation layers. If a product other than those defined in above standards is used as one of the thermal insulation layers, then its properties declared for the composite shall be assessed according to test methods and principles in above mentioned standards.
This standard does not cover the performance of prefabricated systems incorporating these composite products.
This standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Self supporting building products and products for structural use are not covered by this standard.
This standard does not cover in situ composite insulation products, composite products for civil engineering applications and composite products intended to be used for thermal insulation of building equipment and industrial installations.

  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies the requirements for factory made composite products to be used for thermal insulation of buildings, such as composite insulation products with at least two different thermal insulation layers and with or without facings or coatings, and composite products with thermal insulation layer/s bonded to additional external layer/s of non insulation products.  
Products defined by standards EN 13162 to 13171 and prEN 16069 shall be used for the thermal insulation layers. If a product other than those defined in above standards is used as one of the thermal insulation layers, then its properties declared for the composite shall be assessed according to test methods and principles in above mentioned standards.
This standard does not cover the performance of prefabricated systems incorporating these composite products.
This standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Self supporting building products and products for structural use are not covered by this standard.
This standard does not cover in situ composite insulation products, composite products for civil engineering applications and composite products intended to be used for thermal insulation of building equipment and industrial installations.

  • Draft
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies the requirements for factory made expanded perlite board (EPB) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards, multi layered insulation or composite insulation products.
This standard includes EPB multi-layered insulation products. Instructions of Annex D shall be followed.
This standard also covers composite insulation products (see Annex E).
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0.15 m2 K/W or a declared thermal conductivity greater than 0.070 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This standard does not cover the following acoustical aspects: acoustic absorption index and direct airborne sound insulation.

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards, which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.).
This standard includes XPS multi-layered insulation boards with layers perpendicular to the edges of the board, i.e. layers parallel to the surface of the final board.
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations, or civil engineering applications or acoustic insulation.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made rigid polyurethane foam (PU) products, with or without facings or coatings, which are used for the thermal insulation of buildings. PU includes both PIR and PUR products. The products are manufactured in the form of boards.
This standard includes PU multi-layered insulation products. Instructions of Annex D shall be followed.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required class/level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes/levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m K) at 10 °C are not covered by this European Standard.
This standard does not cover in situ insulation products, products intended to be used for the insulation of building equipment and industrial installations.

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made expanded polystyrene products, with or without rigid or flexible facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware (flat, tapered, tongue and grooves, shiplap, profiled etc.).
Products covered by this standard are also used for sound insulation and in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required class or level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity at 10 °C greater than 0,060 W/(m K) are not covered by this standard.
This standard does not cover in-situ insulation products (covered by FprEN 16025-1 and -2), products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14309), products intended to be used in civil engineering applications (covered by EN 14933) and products intended to be used in beam and block systems in floors (covered by EN 15037-4).

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded polystyrene, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware. This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this European Standard are also used for sound insulation and in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required class or level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non conflicting standards. Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity at 10 °C greater than 0,060 W/(m•K) are not covered by this European Standard.

  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made wood wool (WW) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials.
This standard includes WW multilayered insulation products. Instructions of annex C shall be followed.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels and classes required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2 K/W or a declared thermal conductivity greater than 0,100 W/(m K) at 10 °C are not covered by this standard.
This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of phenolic foam, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,40 m2 K/W or a declared thermal conductivity greater than 0,050 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products, products intended to be used for the insulation of building equipment and industrial installations.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

his European Standard specifies the requirements for factory made products of polyethylene foam (PEF), with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other performed ware. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property to be achieved by a products to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,05 m2K/W or a declared thermal conductivity greater than 0,05 W/(m.K) at 10 °C are not covered by this European Standard. This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. Further excluded are non-foamed materials such as bubble films, foils etc.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made wood fibre (WF) products, with or without facings or coatings, which are used for the thermal insulation of buildings ). The products are manufactured in the form of rolls, batts, felts, boards or slabs.
This standard includes WF multi-layered insulation products. Instructions of Annex C shall be followed.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,20 m2 K/W or a declared thermal conductivity greater than 0,070 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
This standard includes CG multi-layered insulation products. Instructions of Annex C shall be followed.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,50 m2 K/W or a declared thermal conductivity greater than 0,065 W/(m K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards without facings or coatings.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W, or a declared thermal conductivity greater than 0,060 W/(m K), at 10 °C, are not covered by this European Standard.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,40 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 [3]).

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804) for factory made and in situ thermal insulation products.
Complementary to EN 15804, the PCR described in this European Standard:
-   specify the declared unit to be used;
-   define the system boundaries for thermal insulation products;
-   specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules.
These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 9229:2007 establishes a vocabulary of terms used in the field of thermal insulation covering materials, products, components and applications.

  • Standard
    48 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded polystyrene, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware.
This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used for sound insulation and in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This European Standard does not specify the required class or level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity at 10 °C greater than 0,060 W/(m•K) are not covered by this European Standard.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made rigid polyurethane foam (PU) products, with or without facings or coatings, which are used for the thermal insulation of buildings. PU includes both PIR and PUR products. The products are manufactured in the form of boards.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 . K/W or a declared thermal conductivity greater than 0,060 W/(m.K) at 10 °C are not covered by this European Standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14308).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,40 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 [3]).

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.).
Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m²K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 C are not covered by this standard.
This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14307), or civil engineering applications (covered by EN 14934).

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made rigid polyurethane foam (PU) products, with or without facings or coatings, which are used for the thermal insulation of buildings. PU includes both PIR and PUR products. The products are manufactured in the form of boards.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 . K/W or a declared thermal conductivity greater than 0,060 W/(m.K) at 10 °C are not covered by this European Standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14308).

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made wood wool (WW) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels and classes required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2K/W or a declared thermal conductivity greater than 0,100 W/(mK) at 10 °C are not covered by this standard.
This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,50 m2K/W or a declared thermal conductivity greater than 0,065 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14305).

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made expanded perlite board products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards, multi-layered insulation or composite insulation products.
This standard also covers composite insulation products (see Annex E).
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2K/W or a declared thermal conductivity greater than 0,070 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,40 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 [3]).

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded polystyrene, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or rolls or other preformed ware.
This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used for sound insulation and in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This European Standard does not specify the required class or level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity at 10 °C greater than 0,060 W/(m•K) are not covered by this European Standard.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards with or without facings or coatings.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W, or a declared thermal conductivity greater than 0,060 W/(mK), at 10 °C, are not covered by this European Standard.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day