Measurement of radioactivity in the environment -Air: radon-222 - Part 5: Continuous measurement method of the activity concentration (ISO 11665-5:2012)

ISO 11665-5:2012 describes continuous measurement methods for radon-222. It gives indications for continuous measuring of the temporal variations of radon activity concentration in open or confined atmospheres.
ISO 11665-5:2012 is intended for assessing temporal changes in radon activity concentration in the environment, in public buildings, in homes and in work places, as a function of influence quantities such as ventilation and/or meteorological conditions.

Ermittlung der Radioaktivität in der Umwelt - Luft: Radon-222 - Teil 5: Kontinuierliches Messverfahren für die Aktivitätskonzentration (ISO 11665-5:2012)

Mesurage de la radioactivité dans l'environnement - Air: radon 222 - Partie 5: Méthode de mesure en continu de l'activité volumique (ISO 11665-5:2012)

L'ISO 11665-5:2012 décrit uniquement les méthodes de mesure en continu du radon 222. Elle donne des indications pour le mesurage en continu des variations temporelles de l'activité volumique du radon dans des atmosphères libres ou confinées.
L'ISO 11665-5:2012 est destinée à évaluer les variations temporelles de l'activité volumique du radon dans l'environnement, les bâtiments publics, les habitations et les lieux de travail en fonction de grandeurs d'influence telles que les conditions de ventilation et/ou météorologiques.

Merjenje radioaktivnosti v okolju - Zrak: radon-222 - 5. del: Neprekinjeno merjenje koncentracije aktivnosti (ISO 11665-5:2012)

ISO 11665-5:2012 opisuje metode neprekinjenega merjenja za radon-222. Podaja navedbe za neprekinjeno merjenje časovnih sprememb koncentracije aktivnosti radona v odprtih in zaprtih prostorih. ISO 11665-5:2012 je namenjen uporabi pri ocenjevanju časovnih sprememb koncentracije aktivnosti radona v okolju, javnih zgradbah ter na domu in delovnih mestih kot funkcija vplivnih veličin, kot so prezračevalni in/ali meteorološki pogoji.

General Information

Status
Withdrawn
Publication Date
15-Sep-2015
Withdrawal Date
04-Feb-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
05-Feb-2020

Relations

Buy Standard

Standard
EN ISO 11665-5:2015
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2015
Merjenje radioaktivnosti v okolju - Zrak: radon-222 - 5. del: Neprekinjeno merjenje
koncentracije aktivnosti (ISO 11665-5:2012)
Measurement of radioactivity in the environment -Air: radon-222 - Part 5: Continuous
measurement method of the activity concentration (ISO 11665-5:2012)
Ermittlung der Radioaktivität in der Umwelt - Luft: Radon-222 - Teil 5: Kontinuierliches
Messverfahren für die Aktivitätskonzentration (ISO 11665-5:2012)
Mesurage de la radioactivité dans l'environnement - Air: radon 222 - Partie 5: Méthode
de mesure en continu de l'activité volumique (ISO 11665-5:2012)
Ta slovenski standard je istoveten z: EN ISO 11665-5:2015
ICS:
13.040.99 Drugi standardi v zvezi s Other standards related to air
kakovostjo zraka quality
17.240 Merjenje sevanja Radiation measurements
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN ISO 11665-5
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2015
EUROPÄISCHE NORM
ICS 17.240
English Version
Measurement of radioactivity in the environment -Air:
radon-222 - Part 5: Continuous measurement method of
the activity concentration (ISO 11665-5:2012)
Mesurage de la radioactivité dans l'environnement - Ermittlung der Radioaktivität in der Umwelt - Luft:
Air: radon 222 - Partie 5: Méthode de mesure en Radon-222 - Teil 5: Kontinuierliches Messverfahren für
continu de l'activité volumique (ISO 11665-5:2012) die Aktivitätskonzentration (ISO 11665-5:2012)
This European Standard was approved by CEN on 12 June 2015.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11665-5:2015 E
worldwide for CEN national Members.

Contents Page
European foreword . 3

European foreword
The text of ISO 11665-5:2012 has been prepared by Technical Committee ISO/TC 85 “Nuclear energy,
nuclear technologies, and radiological protection” of the International Organization for Standardization
(ISO) and has been taken over as EN ISO 11665-5:2015 by Technical Committee CEN/TC 430 “Nuclear
energy, nuclear technologies, and radiological protection” the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by March 2016, and conflicting national standards shall
be withdrawn at the latest by March 2016.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11665-5:2012 has been approved by CEN as EN ISO 11665-5:2015 without any
modification.
INTERNATIONAL ISO
STANDARD 11665-5
First edition
2012-07-15
Measurement of radioactivity in the
environment — Air: radon-222 —
Part 5:
Continuous measurement method of the
activity concentration
Mesurage de la radioactivité dans l’environnement — Air: radon 222 —
Partie 5: Méthode de mesure en continu de l’activité volumique
Reference number
ISO 11665-5:2012(E)
©
ISO 2012
ISO 11665-5:2012(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

ISO 11665-5:2012(E)
Contents Page
Foreword .iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 1
4 Principle . 2
5 Equipment . 3
6 Sampling . 3
6.1 Sampling objective . 3
6.2 Sampling characteristics . 3
6.3 Sampling conditions . 3
7 Detection . 4
8 Measurement . 4
8.1 Procedure . 4
8.2 Influence quantities . 4
8.3 Calibration . 4
9 Expression of results . 5
9.1 Radon activity concentration . 5
9.2 Standard uncertainty . 5
9.3 Decision threshold and detection limit . 5
9.4 Limits of the confidence interval . 5
10 Test report . 5
Annex A (informative) Measurement method using a vented ionization chamber and a current
ionization chamber . 7
Bibliography .13
ISO 11665-5:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11665-5 was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies, and
radiological protection, Subcommittee SC 2, Radiological protection.
ISO 11665 consists of the following parts, under the general title Measurement of radioactivity in the
environment — Air: radon-222:
— Part 1: Origins of radon and its short-lived decay products and associated measurement methods
— Part 2: Integrated measurement method for determining average potential alpha energy concentration of
its short-lived decay products
— Part 3: Spot measurement method of the potential alpha energy concentration of its short-lived decay products
— Part 4: Integrated measurement method for determining average activity concentration using passive
sampling and delayed analysis
— Part 5: Continuous measurement method of the activity concentration
— Part 6: Spot measurement method of the activity concentration
— Part 7: Accumulation method for estimating surface exhalation rate
— Part 8: Methodologies for initial and additional investigations in buildings
The following parts are under preparation:
— Part 9: Method for determining exhalation rate of dense building materials
— Part 10: Determination of diffusion coefficient in waterproof materials using activity concentration measurement
iv © ISO 2012 – All rights reserved

ISO 11665-5:2012(E)
Introduction
Radon isotopes 222, 220 and 219 are radioactive gases produced by the disintegration of radium isotopes 226,
224 and 223, which are decay products of uranium-238, thorium-232 and uranium-235 respectively, and are
all found in the earth’s crust. Solid elements, also radioactive, followed by stable lead are produced by radon
[1]
disintegration .
When disintegrating, radon emits alpha particles and generates solid decay products, which are also radioactive
(polonium, bismuth, lead, etc.). The potential effects on human health of radon lie in its solid decay products
rather than the gas itself. Whether or not they are attached to atmospheric aerosols, radon decay products can
be inhaled and deposited in the bronchopulmonary tree to varying depths according to their size.
Radon is today considered to be the main source of human exposure to natural radiation. The UNSCEAR (2006)
[2]
report suggests that, at the worldwide level, radon accounts for around 52 % of global average exposure to
natural radiation. The radiological impact of isotope 222 (48 %) is far more significant than isotope 220 (4 %),
w
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.