Non destructive testing - Radiation methods - Computed tomography - Part 2: Principle, equipment and samples

This European Standard specifies the general principles of computed tomography (CT), the equipment used and basic considerations of sample, materials and geometry.

Zerstörungsfreie Prüfung - Durchstrahlungsverfahren - Computertomographie - Teil 2: Grundlagen, Geräte und Proben

Dieses Dokument legt die allgemeinen Grundlagen der Computertomografie (CT) sowie die angewendeten Geräte und grundsätzliche Überlegungen zu Proben, Materialien und Geometrie fest.

Essais non destructifs - Méthodes par rayonnements - Tomographie informatisée - Partie 2 : Principes, équipements et échantillons

La présente Norme européenne décrit les principes généraux de la tomographie informatisée (TI), l’équipement utilisé ainsi que les considérations de base relatives à l’échantillon, aux matériaux et à la géométrie.

Neporušitveno preskušanje - Sevalne metode - Računalniška tomografija - 2. del: Osnove, oprema in vzorci

Ta evropski standard določa splošna načela računalniške tomografije (CT), uporabljeno opremo in temeljne zamisli glede vzorcev, materialov in geometrije.

General Information

Status
Withdrawn
Publication Date
30-Aug-2011
Withdrawal Date
02-Apr-2019
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
03-Apr-2019

Relations

Buy Standard

Standard
EN 16016-2:2012
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Zerstörungsfreie Prüfung - Durchstrahlungsverfahren - Computertomographie - Teil 2: Grundlagen, Geräte und ProbenEssais non destructifs - Méthodes par rayonnements - Tomodensitométrie - Partie 2 : Principes, équipements et échantillonsNon destructive testing - Radiation method - Computed tomography - Part 2: Principle, equipment and samples19.100Neporušitveno preskušanjeNon-destructive testingICS:Ta slovenski standard je istoveten z:EN 16016-2:2011SIST EN 16016-2:2012en,fr,de01-marec-2012SIST EN 16016-2:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16016-2
August 2011 ICS 19.100 English Version
Non destructive testing - Radiation methods - Computed tomography - Part 2: Principle, equipment and samples
Essais non destructifs - Méthodes par rayonnements - Tomographie numérisée - Partie 2 : Principes, équipementset échantillons
Zerstörungsfreie Prüfung - Durchstrahlungsverfahren - Computertomographie - Teil 2: Grundlagen, Geräte und Proben This European Standard was approved by CEN on 29 July 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16016-2:2011: ESIST EN 16016-2:2012

CT system components . 15A.1Radiation sources . 15A.1.1Open Tube X-ray sets . 15A.1.2Sealed Tube X-ray Sets . 16A.1.3Linear Accelerators . 16A.1.4X-ray target assemblies . 17A.2Detectors . 18A.2.1Ionisation detectors . 18A.2.2Scintillation detectors . 18A.2.3Semiconductor detectors . 19A.3Manipulation . 19A.4Acquisition, reconstruction, visualisation and storage system . 19A.4.1Acquisition system . 19A.4.2Reconstruction system . 20A.4.3Visualisation system . 20A.4.4Storage system . 20Bibliography . 21 SIST EN 16016-2:2012

4.2 Advantages of CT Computed tomography (CT) is a radiographic method that can be an excellent examination technique whenever the primary goal is to locate and quantify volumetric details in three dimensions. In addition, since SIST EN 16016-2:2012
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.