Aerospace series - Cables, electrical, aircraft use - Test methods - Part 412: Humidity resistance

This standard specifies a method of assessing the capability of a cable to resist different hot and humid environments.
It shall be used together with EN 3475-100.

Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 412: Beständigkeit gegen Feuchte

Diese Norm legt ein Verfahren zur Beurteilung der Widerstandsfähigkeit einer Leitung gegenüber verschiedenen warmen und feuchten Umgebungsbedingungen fest.
Sie ist in Verbindung mit EN 3475-100 anzuwenden.

Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 412: Résistance à l'humidité

Aerospace series - Cables, electrical, aircraft use - Test methods - Part 412: Humidity resistance

General Information

Status
Published
Publication Date
11-Jun-2002
Withdrawal Date
30-Dec-2002
Technical Committee
Drafting Committee
Current Stage
9092 - Decision on results of review/2YR ENQ - revise - Review Enquiry
Start Date
28-Feb-2005
Completion Date
28-Feb-2005

Buy Standard

Standard
EN 3475-412:2004
English language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Aerospace series - Cables, electrical, aircraft use - Test methods - Part 412: Humidity resistanceLuft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 412: Beständigkeit gegen FeuchteSérie aérospatiale - Câbles électriques a usage aéronautique - Méthodes d'essais - Partie 412: Résistance a l'humiditéAerospace series - Cables, electrical, aircraft use - Test methods - Part 412: Humidity resistance49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-412:2002SIST EN 3475-412:2004en01-maj-2004SIST EN 3475-412:2004SLOVENSKI
STANDARD



SIST EN 3475-412:2004



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3475-412June 2002ICS 49.060English versionAerospace series - Cables, electrical, aircraft use - Testmethods - Part 412: Humidity resistanceSérie aérospatiale - Câbles électriques à usageaéronautique - Méthodes d'essais - Partie 412: Résistanceà l'humiditéLuft- und Raumfahrt - Elektrischen Leitungen für LuftfahrtVerwendung - Prüfverfahren - Teil 412: Beständigkeitgegen feuchteThis European Standard was approved by CEN on 20 January 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3475-412:2002 ESIST EN 3475-412:2004



EN 3475-412:2002 (E)2ForewordThis document (EN 2591-412:2002) has been prepared by the European Association of AerospaceManufacturers (AECMA).After enquiries and votes carried out in accordance with the rules of this Association, this Standard hasreceived the approval of the National Associations and the Official Services of the member countries ofAECMA, prior to its presentation to CEN.This European Standard shall be given the status of a national standard, either by publication of an identicaltext or by endorsement, at the latest by December 2002, and conflicting national standards shall bewithdrawn at the latest by December 2002.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark,Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway,Portugal, Spain, Sweden, Switzerland and the United KingdomSIST EN 3475-412:2004



EN 3475-412:2002 (E)31ScopeThis standard specifies a method of assessing the capability of a cable to resist different hot and humidenvironments.It shall be used together with EN 3475-100.2Normative referencesThis European Standard incorporates by dated or undated reference provisions from other publications.These normative references are cited at the appropriate places in the text and the publications are listedhereafter. For dated references, subsequent amendments to or revisions of any of these publications applyto this European Standard only when incorporated in it by amendment or revision. For undated referencesthe latest edition of the publication referred to applies.EN 3475-100Aerospace series – Cables, electrical, aircraft use – Test methods – Part 100: GeneralEN 3475-302Aerospace series – Cables, electrical, aircraft use – Test methods – Part 302: Voltageproof testEN 3475-303Aerospace series – Cables, electrical, aircraft use – Test methods – Part 303: InsulationresistanceEN 3475-405Aerospace series – Cables, electrical, aircraft use – Test methods – Part 405: Bending atambient temperature3Classification of testsTwo levels of humidity resistance are defined together with their applicable test methods:a)level 1 cables – These cables are generally located in pressurised areas at conventional relativehumidity or at operating temperatures (ambient temperature and heating due to current) greater than100 °C. For these cables, method A shall be used as specified in 6.b)level 2 cables – These are cables expose
...