FprEN 12209 rev
(Main)Building hardware - Mechanically operated locks and locking plates - Requirements and test methods
Building hardware - Mechanically operated locks and locking plates - Requirements and test methods
This European Standard specifies requirements and test methods for durability, strength, security, and function of mechanically operated locks and latches and their locking plates for use in doors, window doors and entrance doors in buildings.
Locks, latches and their locking plates used in fire resistant and/or smoke control door assemblies require additional attributes in order to comply with the Essential Requirement "Safety in case of fire" either independently or as a part of a complete assembly. Additional requirements for locks and latches and their locking plates used on fire resistant and/or smoke control door assemblies are specified in annex A.
The following locking devices and associated products are not covered by this European Standard: cylinders for locks, handles, electro-mechanically operated locks and striking plates, multi-point locks and their locking plates, locks for windows, padlocks, locks for safes, furniture locks and prison locks.
NOTE A lock meeting this standard can at the same time be part of an exit device according to EN 179 or EN 1125
Schlösser und Baubeschläge - Mechanisch betätigte Schlösser und Schließbleche - Anforderungen und Prüfverfahren
Die vorliegende Europäische Norm legt Anforderungen an und Prüfverfahren für die Dauerfunktions-tüchtigkeit, Festigkeit, Schutzwirkung und Wirkungsweise von mechanisch betätigten Schlössern und deren Schließblechen fest, die in Türen von Gebäuden zum Einsatz kommen.
Die vorliegende Europäische Norm umfasst Schlösser und deren Schließbleche, die entweder in ihrer Gesamtheit durch einen Hersteller gefertigt und in den Handel gebracht werden oder durch mehr als einen Hersteller aus Baugruppen montiert und anschließend in einem Geschäftsabschluss als Bausatz in den Handel gelangen.
Die vorliegende Norm trifft Festlegungen für Schlösser und deren Schließbleche, die für den Einsatz in unterschiedlichen Umgebungs und Sicherheitsbedingungen vorgesehen sind und folglich unterschiedliche Güteklassen erfordern.
Die vorliegende Europäische Norm trifft keine Festlegungen für Mehrfachverriegelungen und deren Schließbleche, die durch EN 15685 behandelt werden.
Die vorliegende Norm legt die für die Schutzwirkung und Beurteilung der Eignung für Rauchschutztüren erforderlichen Maße und Eigenschaften fest.
Die vorliegende Europäische Norm gilt nicht für Schließzylinder, Türdrücker, Fensterriegel, Vorhänge-schlösser, Tresorschlösser, Möbelschlösser oder Gefängnisschlösser.
Die Beurteilung des Produktbeitrags zum Feuerwiderstand der spezifischen feuer /rauchbeständigen Türeneinheit gehört nicht zum Anwendungsbereich der vorliegenden Europäischen Norm.
Quincaillerie pour le bâtiment - Serrures mécaniques et gâches - Exigences et méthodes d'essai
La présente Norme européenne spécifie les exigences et les méthodes d'essai relatives à l'endurance, la résistance, la sécurité et la fonctionnalité des serrures manœuvrées mécaniquement et leurs gâches lors de leur utilisation sur des portes de bâtiment.
La présente Norme européenne couvre les serrures et leurs gâches qui sont soit fabriquées et mises sur le marché dans leur intégralité par un seul fabricant, soit produites par plusieurs fabricants et mises sur le marché séparément ou en tant que kit au cours d’une transaction unique.
Les serrures et systèmes de verrouillage spécifiés dans la présente norme sont destinés à être utilisés dans de multiples environnements et conditions de sécurité, ce qui implique la nécessiter de définir différents grades.
La présente Norme européenne ne spécifie pas les serrures multipoints et leurs gâches, qui sont définies dans le prEN 15685.
La présente norme définit les dimensions et les propriétés requises dans le cadre de la sécurité et de l'évaluation de l'aptitude des portes pare-fumée.
La présente Norme européenne ne s'applique pas aux cylindres, béquilles, serrures pour fenêtres, cadenas, serrures pour coffres-forts, serrures de meubles et serrures de prison.
L'évaluation de la contribution du produit à la résistance au feu des blocs-portes coupe-feu et/ou pare-fumée spécifiques n'entre pas dans le domaine d'application de la présente Norme européenne.
Stavbno okovje - Mehanske ključavnice in prijemniki - Zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2011
6WDYEQRRNRYMH0HKDQVNHNOMXþDYQLFHLQSULMHPQLNL=DKWHYHLQSUHVNXVQH
PHWRGH
Building hardware - Mechanically operated locks and locking plates - Requirements and
test methods
Schlösser und Baubeschläge - Mechanisch betätigte Schlösser und Schließbleche -
Anforderungen und Prüfverfahren
Quincaillerie pour le bâtiment - Serrures mécaniques et gâches - Exigences et méthodes
d'essai
Ta slovenski standard je istoveten z: prEN 12209 rev
ICS:
91.190 Stavbna oprema Building accessories
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
DRAFT
prEN 12209 rev
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2011
ICS 91.190 Will supersede EN 12209:2003
English Version
Building hardware - Mechanically operated locks and locking
plates - Requirements and test methods
Quincaillerie pour le bâtiment - Serrures mécaniques et Schlösseer und Baubeschläge - Mechanisch betätigte
gâches - Exigences et méthodes d'essai Schlösser und Schließbleche - Anforderungen und
Prüfverfahren
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 33.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 12209 rev:2011: E
worldwide for CEN national Members.
prEN 12209:2011 (E)
Contents Page
Foreword . 5
Introduction . 6
1 Scope. 7
2 Normative references . 7
3 Terms, definitions, symbols and units . 7
3.1 Terms and definitions . 7
4 Classification . 11
4.1 General . 11
4.2 Classification for mechanically operated locks and locking plates . 11
4.2.3 Door mass and closing force (third digit). 12
4.2.4 Suitability for use on fire/smoke doors (fourth digit) . 13
4.2.6 Corrosion resistance and temperature (sixth digit) . 13
4.2.7 Security and drill resistance (seventh digit) . 13
4.2.8 Key identification of lever locks (eight digit) . 14
4.2.9 Example for classification of locks, latches and their locking plates . 14
5 Requirements . 15
5.1 General . 15
5.1.1 Dangerous substances. 15
5.1.2 Return force of latch bolt . 15
5.1.3 Product information requirements . 15
5.1.4 Strength of key . 16
5.1.5 Strength of bolt actions . 16
5.1.6 Minimum follower restoring torque . 16
5.1.7 Protection against removal from door . 16
5.2 Category of use . 16
5.2.2 Torque to operate deadbolt or latch bolt . 17
5.2.3 Strength of follower stops. 18
5.2.4 Torque resistance for lockable deadbolt operation by handle/knob . 18
5.3 Durability requirements . 20
5.3.1 Durability of latch action . 20
5.3.2 Durability of deadbolt mechanism . 20
5.3.3 Durability of locking snib mechanism . 20
5.4 Door mass and door closing force . 20
5.4.1 Door mass . 20
5.4.2 Door closing force . 20
5.5 Suitability for use on fire/smoke doors . 21
5.6 Safety. 21
5.7 Corrosion resistance and temperature . 21
5.7.1 Corrosion resistance . 21
5.7.2 Operation at extremes of temperature . 21
5.8 Security – Attack resistance . 21
5.8.1 Locking . 21
5.8.2 Torque resistance of knob . 21
5.8.3 Requirements for side load . 22
5.8.4 Deadbolt projection . 22
5.8.5 Resistance to forcing in the unlocking direction (disengaging load) . 23
5.8.6 Requirements for pulling of anti separation bolt . 25
prEN 12209:2011 (E)
5.8.7 Requirements for forcing of locating device in sliding door lock . 26
5.8.8 Strong key attack on lever locks . 27
5.8.9 Torque resistance of lockable follower . 28
5.8.10. Security requirements of the component locking plate . 28
5.9 Key identification requirements of lever locks . 32
5.9.1 Minimum number of detaining elements . 32
5.9.2 Minimum number of effective differs . 32
5.9.3 Differing steps height on key . 32
5.9.4 Non-interpassing of keys with just one interval differ . 32
5.9.5 Coding protection . 32
6. Test methods . 33
6.1 General . 33
6.1.1 Test door . 34
6.1.2 Dangerous substances. 34
6.1.3 Return force of latch bolt . 34
6.1.4 Strength of key . 34
6.1.5 Strength of bolt action. . 34
6.1.6 Minimum follower restoring torque . 35
6.1.7 Protection against removal from door . 35
6.2 Category of use . 35
6.2.1 Resistance to side load on latch bolt . 35
6.2.2 Torque to operate deadbolt or latch bolt . 37
6.2.3 Strength of follower stops. 37
6.2.4 Torque resistance of lockable follower . 37
6.3 Durability . 38
6.3.1 Durability of latch action . 38
6.3.1.2 Durability of latch action with force applied . 39
6.3.2 Durability of deadbolt mechanism . 40
6.3.3 Durability of locking snib mechanism . 41
6.4 Door mass and closing force . 41
6.4.1 Door mass .
...
Questions, Comments and Discussion