prEN 1125
(Main)Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
This European Standard specifies requirements for the manufacture; performance and testing of panic exit devices mechanically operated by a horizontal bar, for the purpose of achieving a safe exit under a panic situation on escape routes.
This European Standard covers panic exit devices which are either manufactured and placed on the market in their entirety by one producer or assembled from sub-assemblies produced by more than one producer and subsequently placed on the market as a kit in a single transaction.
Schlösser und Baubeschläge - Paniktürverschlüsse mit horizontaler Betätigungsstange für Türen in Rettungswegen - Anforderungen und Prüfverfahren
Diese Europäische Norm legt Anforderungen an Herstellung, Gebrauchstauglichkeit und Prüfung von Paniktürverschlüssen fest, die mechanisch über eine horizontale Stange betätigt werden, und die speziell für die Benutzung in Paniksituationen in Fluchtwegen ausgelegt sind.
Diese Europäische Norm behandelt Paniktürverschlüsse, die entweder insgesamt durch einen Hersteller gefertigt und in Verkehr gebracht oder durch mehr als einen Hersteller gefertigt und anschließend in einem Vorgang als Montagesatz in Verkehr gebracht werden.
Quincaillerie pour le bâtiment - Fermetures anti-panique manoeuvrées par une barre horizontale, pour portes situées sur les voies d'evacuation - Prescriptions et méthodes d'essais
La présente Norme européenne spécifie les exigences pour la fabrication, les performances et les essais des fermetures anti-panique manoeuvrées mécaniquement par une barre horizontale dans le but d'assurer une évacuation en toute sécurité dans une situation de panique sur des voies d'évacuation.
La présente Norme européenne couvre les fermetures anti-panique qui sont soit fabriquées et mises sur le marché dans leur intégralité par un fabricant, soit assemblées à partir de sous-assemblages produits par plus d'un fabricant et ultérieurement mises sur le marché en tant que kit au cours d'une transaction unique.
Ključavnice in stavbno okovje - Zapore z vodoravnim potisnim drogom za zasilne izhode ob paniki - Zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2017
.OMXþDYQLFHLQVWDYEQRRNRYMH=DSRUH]YRGRUDYQLPSRWLVQLPGURJRP]D]DVLOQH
L]KRGHRESDQLNL=DKWHYHLQSUHVNXVQHPHWRGH
Build hardware - Panic exit devices operated by a horizontal bar, for use on escape
routes - Requirements and test methods
Schlösser und Baubeschläge - Paniktürverschlüsse mit horizontaler Betätigungsstange
für Türen in Rettungswegen - Anforderungen und Prüfverfahren
4XLQFDLOOHULHSRXUOHEkWLPHQW)HUPHWXUHVDQWL"SDQLTXHPDQ°XYUpHVSDUXQHEDUUH
KRUL]RQWDOHSRXUSRUWHVVLWXpHVVXUOHVYRLHVG
pYDFXDWLRQ3UHVFULSWLRQVHWPpWKRGHV
G
HVVDLV
Ta slovenski standard je istoveten z: prEN 1125
ICS:
91.190 Stavbna oprema Building accessories
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2016
ICS 91.190 Will supersede EN 1125:2008
English Version
Build hardware - Panic exit devices operated by a
horizontal bar, for use on escape routes - Requirements
and test methods
Quincaillerie pour le bâtiment - Fermetures anti- Schlösser und Baubeschläge - Paniktürverschlüsse mit
panique manœuvrées par une barre horizontale, pour horizontaler Betätigungsstange für Türen in
portes situées sur les voies d'évacuation - Rettungswegen - Anforderungen und Prüfverfahren
Prescriptions et méthodes d'essais
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 33.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 1125:2016 E
worldwide for CEN national Members.
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 7
2 Normative references . 7
3 Terms, definitions, symbols and abbreviations . 7
3.1 Terms and definitions . 7
4 Product characteristics . 13
4.1 General . 13
4.2 Ability to release. 13
4.3 Suitability for use on fire and smoke resisting doorsets . 21
4.4 Self-closing . 21
4.5 Dangerous substances . 22
4.6 Durability of ability to release against aging and degradation (for doors on escape
routes) . 22
4.7 Durability of self-closing ability C against aging and degradation (for fire/smoke
doors) . 25
4.8 Product information . 25
5 Testing, assessment and sampling methods . 26
5.1 General . 26
5.2 Tests for ability to release . 30
5.3 Tests for suitability to use on fire doors (Sample C) . 31
5.4 Tests for self-closing: Dynamic Closing test (Sample B) . 31
5.5 Control of Dangerous substances . 32
5.6 Tests for durability of ability to release. 32
5.7 Tests for durability of self-closing ability. 38
5.8 Control of product information (Sample B) . 39
6 Assessment and verification of constancy of performance - AVCP . 39
6.1 General . 39
6.2 Type testing . 39
6.3 Factory production control (FPC) . 41
7 Classification . 45
st
7.1 Category of use (1 character) . 45
nd
7.2 Durability (2 character) . 45
rd
7.3 Door leaf mass (3 character) . 46
th
7.4 Suitability for use on fire/smoke doors (4 character) . 46
th
7.5 Safety (5 character) . 46
th
7.6 Corrosion resistance (6 character) . 46
th
7.7 Security (7 character) . 46
th
7.8 Projection of horizontal bar (8 character) . 47
th
7.9 Type of horizontal bar operation (9 character) . 47
th
7.10 Field of door application (10 character) . 47
7.11 Example of classification . 47
8 Marking . 48
8.1 On the product . 48
8.2 On the packaging . 48
8.3 On the installation instructions . 48
8.4 Mortise lock combined with a separate horizontal bar unit . 49
Annex A (informative) Installation and fixing instructions . 50
Annex B (informative) Maintenance instructions . 52
Annex C (normative) Flow chart of test procedures . 53
Annex D (informative) Guidance for choosing relevant product standards for particular
exit door applications . 55
Annex E (informative) Examples of configurations and description of exit systems . 56
Annex ZA (informative) Relationship of this European Standard with Regulation (EU)
No.305/2011 . 57
ZA.1 ZA.1 Scope and relevant characteristics. 57
ZA.2 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP). 58
ZA.3 ZA.3 Assignment of AVCP tasks . 59
European foreword
This document (prEN 1125:2016) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 1125:2008.
The major changes in this revision are as follows:
nd
— different sealing forces have been introduced for classification of the durability (2 digit);
th
— a new bar type C has been introduced (9 digit);
th
— an additional grade has been introduced for release force, in relation with safety classification (5
digit);
th
— definition of field of door application has been modified (10 digit);
— safety requirements about Outside Access Device have been added;
th
— security grades have been added (7 digit);
— durability tests have been clarified;
— a pictogram to recognise the active leaf has been added.
A full contribution to the preparation of this European Standard has been made by The European
Federation of Associations of Lock and Builders Hardware Manufacturers (ARGE).
This European Standard is part of a group of standards dedicated to building hardware products. It is
one of a group of standards for exit devices and exit systems developed by Technical Committee
CEN/TC 33.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this
document.
Introduction
Experience relating to escape from buildings, fire and/or smoke hazards and general safety has made it
desirable that doors, in public areas, public buildings, places of public entertainment, shops etc, or those
that have to be operated in a panic situation, be fitted with panic exit devices operated by a horizontal
bar to common European Standard specifications.
The main purpose of the performance requirements contained in this European Standard is to give safe
and effective escape through a doorway with one single operation by hand and/or body pressure to
release the panic exit device, with minimum effort and without prior knowledge of the panic exit device.
In a panic situation, a group of people will react differently from an individual. When two or more
people are rushing to an exit door located on an escape route, probably in darkness and/or smoke, it is
possible that the first one to reach the door shall not necessarily operate the panic
...
Questions, Comments and Discussion