Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-3: Einbruchmelder - Glasbruchmelder (Aktiv)

Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-7-3: Détecteurs d'intrusion - Détecteurs bris de glace (actifs)

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-3. del: Zahteve za javljalnike vloma - Javljalniki loma stekla (aktivni) - Dopolnilo A2

General Information

Status
Published
Publication Date
09-Jun-2016
Withdrawal Date
10-Apr-2019
Technical Committee
CLC/TC 79 - Alarm systems
Drafting Committee
CLC/TC 79 - Alarm systems
Current Stage
6060 - Document made available - Publishing
Start Date
10-Jun-2016
Due Date
03-Mar-2017
Completion Date
10-Jun-2016

Relations

Effective Date
26-Jan-2023

Overview

EN 50131-2-7-3:2012/A2:2016 is a CENELEC amendment to the European security standard for active glass break detectors used in alarm systems. This amendment (A2) updates testing conditions to clarify the acceptance criteria for immunity to mechanical impact on glass panes and revises the normative catalogue for the standard immunity test glass. It was approved on 2016-04-11 and is part of the EN 50131 family for intrusion and hold-up systems.

Key topics and requirements

  • Scope of amendment: Allows products to meet the relevant test section by aligning test parameters with the revised Annex - specifically for clause 6.6.3 Immunity to hard objects hitting the glass and Annex A (Catalogue of standard glass types).
  • Immunity test angle (clause 6.7.4): The specified impact angle for the immunity test is changed from α = 60° ± 5° to α = 27° ± 1°. This adjustment affects how a hard-object impact is applied during type testing.
  • Standard immunity glass pane (Annex A): The test glass pane thickness is changed from 4 mm ± 1 mm to 6 mm ± 1 mm (size retained at 800 mm × 1 m, framed standard plate glass). Annex A remains normative and provides the catalogue of standard glass types to be used for laboratory testing.
  • Implementation timeline: National adoption and withdrawal dates are specified in the amendment (latest date of publication/endorsement and conflicting national standards withdrawal as per CENELEC rules).

Applications and who uses this standard

  • Manufacturers of active glass break detectors: Use the amendment to design, validate and demonstrate product robustness against impacts and to ensure conformance with EN 50131 requirements.
  • Test laboratories and certification bodies: Adopt the revised test angle and updated immunity glass specifications for type testing, conformity assessment and issuing certifications.
  • System designers, integrators and specifiers: Reference the standard when selecting detectors for commercial and residential intrusion alarm systems to ensure selected devices meet recognized immunity performance.
  • Regulators and procurers: Use the standard in tenders and regulatory frameworks to define minimum performance and test conditions for glass break detection equipment.

Related standards

  • EN 50131 series - the overall European standard family for intrusion and hold-up systems (refer to the appropriate parts for system-level, detector-level and installation requirements).
  • CENELEC technical committee documents (CLC/TC 79) for alarm system standardization and implementation guidance.

Keywords: EN 50131-2-7-3:2012/A2:2016, glass break detectors, active glass break, immunity testing, alarm systems, CENELEC amendment, standard glass pane, intrusion detectors.

Amendment

EN 50131-2-7-3:2012/A2:2016

English language
4 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 50131-2-7-3:2012/A2:2016 is a amendment published by CLC. Its full title is "Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)". This standard covers: Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A

EN 50131-2-7-3:2012/A2:2016 is classified under the following ICS (International Classification for Standards) categories: 13.320 - Alarm and warning systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50131-2-7-3:2012/A2:2016 has the following relationships with other standards: It is inter standard links to EN 50131-2-7-3:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 50131-2-7-3:2012/A2:2016 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2016
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-3. del: Zahteve za
javljalnike vloma - Javljalniki loma stekla (aktivni) - Dopolnilo A2
Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass
break detectors (active)
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-3: Einbruchmelder -
Glasbruchmelder (Aktiv)
Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-7-3:
Détecteurs d'intrusion - Détecteurs bris de glace (actifs)
Ta slovenski standard je istoveten z: EN 50131-2-7-3:2012/A2:2016
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50131-2-7-3:2012/A2

NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 13.320
English Version
Alarm systems - Intrusion and hold-up systems - Part 2-7-3:
Intrusion detectors - Glass break detectors (active)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 2-7-3: Détecteurs d'intrusion - 2-7-3: Einbruchmelder - Glasbruchmelder (Aktiv)
Détecteurs bris de glace (actifs)
This amendment A2 modifies the European Standard EN 50131-2-7-3:2012; it was approved by CENELEC on 2016-04-11. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
...

Questions, Comments and Discussion