Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion

IEC 60079-35-1:2011 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I - electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements for performance are in IEC 60079-35-2. This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. This first edition cancels and replaces the second edition of IEC 62013-1, published in 2005, and constitutes a full technical revision. The main technical differences with respect to the previious edition are: - the introduction of a means to achieve an equipment protection level (EPL) of Ma; - the introduction of a single clause relating to equipment construction replacing individual specific clauses for the headpiece, battery, cable and external charging contacts; - the deletion of statements relating to surface temperature, the rewording of statements relating to creepage and clearance and the addition of statements relating to thermal protection, electronic assemblies and additional circuitry; - specific referenc to lithium cells; - the addition of statements relating to battery recharging and protection against deep discharge.

Kopfleuchten für die Verwendung in schlagwettergefährdeten Grubenbauen - Teil 35-1: Allgemeine Anforderungen - Konstruktion und Prüfung in Relation zum Explosionsrisiko

Atmosphères explosives - Partie 35-1: Lampes-chapeaux utilisables dans les mines grisouteuses - Exigences générales - Construction et essais liés au risque d'explosion

La CEI 60079-35-1:2011 spécifie les exigences pour la construction, les essais et le marquage des lampes-chapeaux, y compris les lampes-chapeaux avec un point de connexion pour d'autres matériels, utilisables dans les mines grisouteuses (Groupe I - matériels électriques pour les atmosphères explosives gazeuses comme définies dans la CEI 60079-0). Elle traite uniquement du risque, présenté par une lampe-chapeau, de devenir une source d'inflammation. Les exigences d'aptitude à la fonction se trouvent dans la CEI 60079-35-2. La présente norme complète et modifie les exigences générales de la CEI 60079-0, excepté pour ce qui est indiqué dans le Tableau 1. Cette première édition annule et remplace la deuxième édition de la CEI 62013-1, parue en 2005, et constitue une révision technique générale. Les différences techniques principales par rapport à l'édition précédente sont: - l'introduction d'un article unique relatif à la construction du matériel, remplaçant les différents articles spécifiques pour le projecteur, la batterie, le câble et les contacts extérieurs de charge; - la suppression des indications concernant la température de surface, la reformulation des énoncés relatifs aux lignes de fuite et aux distances dans l'air, et l'adjonction d'indications concernant la protection thermique, les ensembles électroniques et les circuits additionnels; - une référence spécifique aux éléments au lithium; - l'adjonction d'indications concernant la recharge de la batterie et la protection contre la décharge sévère.

Rudarske naglavne svetilke za uporabo v rudnikih, kjer se lahko pojavi jamski eksplozivni plin - 1. del: Splošne zahteve - Konstruiranje in preskušanje zaradi tveganja eksplozije (IEC 60079-35-1:2011)

Ta del IEC 60079-35 določa zahteve za konstruiranje, preskušanje in označevanje rudarskih naglavnih svetilk, vključno z rudarskimi naglavnimi svetilkami s priključkom za drugo opremo, za uporabo v rudnikih, kjer se lahko pojavi jamski eksplozivni plin (skupina I – električna oprema za eksplozivne plinske atmosfere, kot je opredeljeno v IEC 60079-0). Obravnava le tveganje, da bi rudarska naglavna svetilka postala vir vžiga. Zahteve za delovanje so navedene v IEC 60079-35-2.1. Ta standard dopolnjuje in spreminja splošne zahteve IEC 60079-0, razen kot je navedeno v preglednici 1. Kjer zahteva tega standarda nasprotuje zahtevi IEC 60079-0, imajo zahteve tega standarda prednost. Skladnost s tem standardom zagotavlja EPL Mb (glej točko 4.1 tega standarda). Če je zahtevan EPL Ma, mora rudarska naglavna svetilka ustrezati zahtevam iz točke 4.2 tega standarda, ki se sklicuje na IEC 60079-11. Pričakuje se, da rudarske naglavne svetilke, ki ustrezajo temu standardu (EPL Mb), občasno obratujejo v atmosferah, kjer jamski eksplozivni plin presega zakonske ravni, pri katerih je treba ljudi odstraniti iz atmosfere z veliko količino jamskega eksplozivnega plina v varno območje. Pri načrtovanju opreme za obratovanje v pogojih, ki niso navedeni zgoraj, se ta standard lahko uporablja kot vodilo, lahko pa je potrebno dodatno preskušanje. Kadar je rudarska naglavna svetilka ocenjena kot intrinzično varna oprema, Ex ia, v skladu z IEC 60079-11, je treba uporabiti le točke/podtočke, navedene v 4.2.

General Information

Status
Published
Publication Date
11-Aug-2011
Withdrawal Date
29-Jun-2014
Current Stage
6060 - Document made available - Publishing
Start Date
12-Aug-2011
Completion Date
12-Aug-2011

Relations

Buy Standard

Standard
EN 60079-35-1:2011
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2011
1DGRPHãþD
SIST EN 62013-1:2006
Rudarske naglavne svetilke za uporabo v rudnikih, kjer se lahko pojavi jamski
eksplozivni plin - 1. del: Splošne zahteve - Konstruiranje in preskušanje zaradi
tveganja eksplozije (IEC 60079-35-1:2011)
Caplights for use in mines susceptible to firedamp - Part 1: General requirements -
Construction and testing in relation to the risk of explosion (IEC 60079-35-1:2011)
Kopfleuchten für die Verwendung in schlagwettergefährdeten Grubenbauen - Teil 35-1:
Allgemeine Anforderungen - Konstruktion und Prüfung in Relation zum Explosionsrisiko
(IEC 60079-35-1:2011)
Lampes-chapeaux utilisables dans les mines grisouteuses - Partie 1: Exigences
générales - Construction et essais liés au risque d'explosion (CEI 60079-35-1:2011)
Ta slovenski standard je istoveten z: EN 60079-35-1:2011
ICS:
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
73.100.20 3UH]UDþHYDOQD Ventilation, air-conditioning
NOLPDWL]DFLMVNDLQ and illumination equipment
UD]VYHWOMHYDOQDRSUHPD
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60079-35-1
NORME EUROPÉENNE
August 2011
EUROPÄISCHE NORM
ICS 29.260.20 Supersedes EN 62013-1:2006

English version
Explosive atmospheres -
Part 35-1: Caplights for use in mines susceptible to firedamp -
General requirements -
Construction and testing in relation to the risk of explosion
(IEC 60079-35-1:2011)
Atmosphères explosives -  Kopfleuchten für die Verwendung in
Partie 35-1: Lampes-chapeaux utilisables schlagwettergefährdeten Grubenbauen -
dans les mines grisouteuses - Teil 35-1: Allgemeine Anforderungen -
Exigences générales - Konstruktion und Prüfung in Relation zum
Construction et essais liés au risque Explosionsrisiko
d'explosion (IEC 60079-35-1:2011)
(CEI 60079-35-1:2011)
This European Standard was approved by CENELEC on 2011-06-30. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60079-35-1:2011 E
Foreword
The text of document 31/921/FDIS, future edition 1 of IEC 60079-35-1, prepared by IEC TC 31,
Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as EN 60079-35-1 on 2011-06-30.
This European Standard supersedes EN 62013-1:2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-03-30
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-06-30
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and covers essential requirements of
EC Directive ATEX (94/9/EC). See Annex ZZ.
Annexes ZA, ZY and ZZ have been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60079-35-1:2011 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 60079-35-1:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 60050-426 - International Electrotechnical Vocabulary - - -
Part 426: Equipment for explosive
atmospheres
IEC 60050-845 - International Electrotechnical Vocabulary - -
(IEV) -
Chapter 845: Lighting
IEC 60079-0 - Explosive atmospheres - EN 60079-0 -
Part 0: Equipment - General requirements

IEC 60079-1 - Explosive atmospheres - EN 60079-1 -
Part 1: Equipment protection by flameproof
enclosures "d"
IEC 60079-7 - Explosive atmospheres - EN 60079-7 -
Part 7: Equipment protection by increased
safety "e"
IEC 60079-11 - Explosive atmospheres - EN 60079-11 -
Part 11: Equipment protection by intrinsic
safety "i"
IEC 60127-2 - Miniature fuses - EN 60127-2 -
Part 2: Cartridge fuse-links
IEC 60332-1-1 - Tests on electric and optical fibre cables EN 60332-1-1 -
under fire conditions -
Part 1-1: Test for vertical flame propagation
for a single insulated wire or cable - Apparatus

IEC 60332-1-2 - Tests on electric and optical fibre cables EN 60332-1-2 -
under fire conditions -
Part 1-2: Test for vertical flame propagation
for a single insulated wire or cable -
Procedure for 1 kW pre-mixed flame

IEC 60664-3 - Insulation coordination for equipment within EN 60664-3 -
low-voltage systems -
Part 3: Use of coating, potting or moulding for
protection against pollution
UL 1642 - Standard for Lithium Batteries - -

Annex ZY
(informative)
Significant changes between EN 60079-35-1:2011 and EN 62013-1: 2006
This European Standard supersedes EN 62013-1:2006.
The significant changes with respect to EN 62013-1:2006 are as listed below.
Type
Significant Changes Clause Minor and Extension Major
editorial technical
changes changes
This first edition cancels and replaces EN 62013-1:  X
2006, and constitutes a full technical revision.
The requirements of EN 60079-0 now apply to this Scope X
standard with the exceptions of the exclusions listed
in Table 1.
Provision has also been provided for a means to
assess caplights to EPL Ma.
The standard has been re-written to be more in-line X
with other EN 60079 series standards.
Table 1 introduced to identify the clauses of EN Table 1 X
60079-0 which are excluded.
The requirements for caplights conforming to EPL 4.1 X
Mb defined.
The additional requirements for caplights 4.2 X
conforming to EPL Ma defined.
Thermal protection of electronic components added. 5.10 X
Additional requirements applied to cells and 6.1 X
batteries.
Cells and batteries are now restricted to those 7 X
meeting the requirements of EN 60079-0.
Type verification testing, where applicable refers 8 X
back to the requirements in EN 60079-0

NOTE: The technical changes referred include the significant technical changes from the EN
revised but is not an exhaustive list of all modifications from EN 62013-1:2006.

- 5 - EN 60079-35-1:2011
Explanations:
A) Definitions
Minor and editorial changes clarification
decrease of technical requirements
minor technical change
editorial corrections
Changes in a standard classified as ‘Minor and editorial changes’ refer to changes regarding the previous
standard, which modify requirements in an editorial or a minor technical way. Also changes of the wording
to clarify technical requirements without any technical change are classified as ‘Minor and editorial
changes’.
A reduction in level of existing requirement is also classified as ‘Minor and editorial changes’

Extension addition of technical options

Changes in a standard classified as ‘extension’ refers to changes regarding the previous standard, which
add new or modify existing technical requirements, in a way that new options are given, but without
increasing requirements for equipment that was fully compliant with the previous standard. Therefore
these ‘extensions’ will not have to be considered for products in conformity with the preceding edition.

Major technical change addition of technical requirements
increase of technical requirements

Changes in a standard classified as ‘Major technical change’ refer to changes regarding the previous
standard, which add new or increase the level of existing technical requirements, in a way that a product
in conformity with the preceding standard will not always be able to fulfil the requirements given in the
standard. ‘Major technical changes’ have to be considered for products in conformity with the preceding
edition. For every change classified as ‘Major Technical Change’ additional information is provided in
clause B) of the Annex ZY.
Note: These changes represent current technological knowledge . However, these changes should not
normally have an influence on equipment already placed on the market.
B) Information about the background of ‘Major Technical Changes’
None.
Instructions:
The manufacturer or his authorised representative in the Community is to draw up the instructions for use
in the required Community languages.
Marking:
The marking in this standard is to be supplemented/modified by the marking according to Directive
94/9/EC. Examples are given below.

European marking examples
Directive part Standard part   Equipment example

Ε I M2 Ex I Mb EN 60079-35-1 (0°C ≤ Ta ≤ +40°C) Caplight suitable for EPL Mb

Ε I M1 Ex ia I Ma EN 60079-35-1 (-10°C ≤ Ta ≤ +40°C) Caplight suitable for EPL Ma

see also ATEX Guide 10.3 and Annex ZZ

Annex ZZ
(informative)
Coverage of essential requirements of the directive 94/9/EC

This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and within its scope the standard covers only the
following essential requirements and out of those given in Annex II of the Directive 94/9/EC:

- ER 1.0.1 to ER 1.0.6;
- ER 1.1.1 to ER 1.1.3;
- ER 1.2.1 to ER 1.2.9;
- ER 1.3.1 to ER 1.3.5;
- ER 1.4.1 to ER 1.4.2;
- ER 2.0.1.1 to ER 2.0.1.4;
- ER 2.0.2.1 to ER 2.0.2.3;
Compliance with this standard provides one means of conformity with the specified essential
requirements of the Directive concerned.

WARNING: Other requirements and other EC Directives may be applicable to the products falling within
the scope of this standard.
IEC 60079-35-1 ®
Edition 1.0 2011-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Explosive atmospheres –
Part 35-1: Caplights for use in mines susceptible to firedamp – General
requirements – Construction and testing in relation to the risk of explosion

Atmosphères explosives –
Partie 35-1: Lampes-chapeaux utilisables dans les mines grisouteuses –
Exigences générales – Construction et essais liés au risque d'explosion

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX R
ICS 29.260.20 ISBN 978-2-88912-518-0

– 2 – 60079-35-1  IEC:2011
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 10
3 Terms and definitions . 10
4 Level of protection . 11
4.1 General . 11
4.2 Additional requirements for EPL “Ma” . 12
4.3 Thermal ignition compliance . 12
4.4 Spark ignition compliance . 12
5 Equipment construction . 12
5.1 Enclosures . 12
5.1.1 Headpiece enclosure . 12
5.1.2 Batt
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.