Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 Ω (type TMA) - 50 Ω applications

IEC 61169-38:2008(E) which is a sectional specification, provides information and rules for the preparation of detail specifications for series TMA r.f. connectors together with the pro forma blank detail specification. Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power. The connectors are usable up to a frequency of at least 6 GHz.

Hochfrequenz-Steckverbinder - Teil 38: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder mit Einschubkupplung (Einschubausführung) - Wellenwiderstand 50 Ω (Typ TMA) - 50-Ω-Anwendungen

Connecteurs pour fréquences radioélectriques - Partie 38: Spécification intermédiaire - Connecteurs coaxiaux pour fréquences radioélectriques, de type glissant (applications en panneau et fond de panier) - Impédance caractéristique 50 Ω (type TMA) - Applications à 50 Ω

La CEI 61169-38:2008 est une spécification intermédiaire (SS: Sectional Specification). Elle fournit des informations et des règles pour la préparation de spécifications particulières (DS: Detail Specification) pour les connecteurs RF de type TMA en série et le modèle pro-forma de la spécification particulière cadre. Les connecteurs de type TMA en série ont une impédance caractéristique de 50 Ω et sont normalement utilisés avec des câbles RF ou avec un micro-ruban dans des champs hyperfréquences ayant une entrée aveugle et une puissance basse moyenne. Les connecteurs peuvent être utilisés jusqu'à une fréquence pouvant atteindre au moins 6 GHz. La présente spécification prescrit également les dimensions des faces d'accouplement pour des connecteurs d'usage général, des informations détaillées sur les dimensions de connecteurs d'essais normalisés (catégorie 0), des informations sur les calibres et des essais choisis dans la norme QC 220000 (CEI 61169-1), applicables à toutes les spécifications particulières portant sur des connecteurs de type TMA en série. La présente spécification indique les caractéristiques de performance recommandées à prendre en considération pour rédiger une spécification particulière et elle porte sur des programmes d'essais et des exigences d'inspection pour les niveaux d'assurance M et H.

Radiofrekvenčni konektorji - 38. del: Področna specifikacija - Model radiofrekvenčnih koaksialnih zdrsnih konektorjev (za stojalo in ploščo) - Karakteristična impedanca 50 ohmov (tip TMA) - 50-ohmske aplikacije (IEC 61169-38:2008)

General Information

Status
Published
Publication Date
01-Mar-2009
Withdrawal Date
30-Nov-2011
Current Stage
6060 - Document made available - Publishing
Start Date
02-Mar-2009
Completion Date
02-Mar-2009

Buy Standard

Standard
EN 61169-38:2009
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2009
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD0RGHO
UDGLRIUHNYHQþQLKNRDNVLDOQLK]GUVQLKNRQHNWRUMHY ]DVWRMDORLQSORãþR 
.DUDNWHULVWLþQDLPSHGDQFDRKPRY WLS70$ RKPVNHDSOLNDFLMH ,(&

Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial
connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 O
(type TMA) - 50 O applications (IEC 61169-38:2008)
Hochfrequenz-Steckverbinder - Teil 38: Rahmenspezifikation - Koaxiale
Hochfrequenzsteckverbinder mit Einschubkupplung (Einschubausführung) -
Wellenwiderstand 50 O (Typ TMA) - 50-O-Anwendungen (IEC 61169-38:2008)
Connecteurs pour fréquences radioélectriques - Partie 38: Spécification intermédiaire -
Connecteurs coaxiaux pour fréquences radioélectriques avec accouplements de type
glis (applications de panneau et fond de panier ) - Impédance caractéristique 50 O
(type TMA) - Applications à 50 O (CEI 61169-38:2008)
Ta slovenski standard je istoveten z: EN 61169-38:2009
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61169-38
NORME EUROPÉENNE
March 2009
EUROPÄISCHE NORM
ICS 33.120.20
English version
Radio-frequency connectors -
Part 38: Sectional specification -
Radio frequency coaxial connectors model, slide-in
(rack and panel applications) -
Characteristic impedance 50 Ω (type TMA) -
50 Ω applications
(IEC 61169-38:2008)
Connecteurs pour fréquences radioélectriques - Hochfrequenz-Steckverbinder -
Partie 38: Spécification intermédiaire - Teil 38: Rahmenspezifikation -
Connecteurs coaxiaux pour fréquences Koaxiale Hochfrequenzsteckverbinder mit
radioélectriques avec accouplements de type glis Einschubkupplung (Einschubausführung) -
(applications de "panneau" et "fond de panier") - Wellenwiderstand 50 Ω (Typ TMA) -
Impédance caractéristique 50 Ω (type TMA) - 50-Ω-Anwendungen
Applications à 50 Ω
(IEC 61169-38:2008)
(CEI 61169-38:2008)
This European Standard was approved by CENELEC on 2008-12-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-38:2009 E
Foreword
The text of document 46F/75/CDV, future edition 1 of IEC 61169-38, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-38 on 2008-12-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-12-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-38:2008 was approved by CENELEC as a European
Standard without any modification.
__________
– 3 – EN 61169-38:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
Part 1: Generic specification - General
requirements and measuring methods

1)
IEC QC 001005 - IEC Quality assessment system for - -
electronic components (IECQ) - Register of
films, products and services approved under
the IECQ system, including ISO 9000

1)
Undated reference.
IEC 61169-38
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,
slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type
TMA) – 50 Ω applications
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.20 ISBN 2-8318-1008-7
– 2 – 61169-38 © IEC:2008(E)
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Mating face and gauge information.7
3.1 Dimensions – General connectors – Grade 2.7
3.1.1 Connector with pin centre contact (see Figure 1) .7
3.1.2 Connectors with socket-centre contact (see Figure 2).8
3.2 Gauges .9
3.2.1 Connectors with pin-centre contact.9
3.2.2 Connectors with socket-centre contact .10
3.3 Dimensions – standard test connectors – Grade 0.11
3.3.1 Connector with pin-centre contact (see Figure 5).11
3.3.2 Connector with socket-centre contact (see Figure 6) .12
3.4 General requirements for connector mounting in modules and on panels.14
3.4.1 Radial misalignment .14
3.4.2 Axial misalignment .14
4 Quality assessment procedure.15
4.1 General .15
4.2 Rating and characteristics ( see Clause 6 of IEC 61169-1/QC220000) .15
4.3 Test schedule and inspection requirements .18
4.3.1 Acceptance tests (see Table 8).18
4.3.2 Periodic tests (see Table 9) .19
4.4 Procedures.20
4.4.1 Quality conformance inspection .20
4.4.2 Qualification approval and its maintenance.20
5 Instructions for preparation of detail specifications .20
5.1 General .20
5.2 Identification of the detail specification .21
5.3 Identification of the component.21
5.4 Performance.21
5.5 Marking, ordering information and related matters .21
5.6 Selection of tests, test conditions and severities.22
5.7 Blank detail specification pro-forma for type TMA connector.23

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1).7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) .8
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3) .9
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4).10
Figure 5 – Standard test connector with pin-centre contact (for dimensions, see Table 5).11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) .12
Figure 7 – The sketch map of connector radial misalignment .14
Figure 8 – The sketch map of rigidly mounted and float-mounted connector.14

Table 1 – Dimensions of connector with pin-centre contact .7

61169-38 © IEC:2008(E) – 3 –
Table 2 – Dimensions of connector with socket-centre contact.8
Table 3 – Dimensions of gauge for outer contact of pin connector .9
Table 4 – Dimensions of gauge pin for socket-center contact.10
Table 5 – Dimensions of standard test connector with pin-centre contact.11
Table 6 – Dimensions of standard test connector with socket-centre contact .13
Table 7 – Rating and characteristics .15
Table 8 – Acceptance tests.18
Table 9 – Periodic tests .19

– 4 – 61169-38 © IEC:2008(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.