Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)

D109/093: CLC/TC 211 renumbered CLC/TC 106X * Superseded by EN 62209-1:2006

Grundnorm zur Messung der Spezifischen Absorptionsrate (SAR) in Bezug auf die Sicherheit von Personen in elektromagnetischen Feldern von Mobiltelefonen (300 MHz bis 3 GHz)

Norme de base relative à la mesure du Débit d'Absorption Spécifique relatif à l'exposition des personnes aux champs électromagnétiques émis par les téléphones mobiles (300 MHz - 3 GHz)

Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)

General Information

Status
Withdrawn
Publication Date
12-Jul-2001
Withdrawal Date
28-Feb-2003
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Mar-2009
Completion Date
01-Mar-2009

Relations

Buy Standard

Standard
EN 50361:2002
English language
51 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)Grundnorm zur Messung der Spezifischen Absorptionsrate (SAR) in Bezug auf die Sicherheit von Personen in elektromagnetischen Feldern von Mobiltelefonen (300 MHz bis 3 GHz)Norme de base relative à la mesure du Débit d'Absorption Spécifique relatif à l'exposition des personnes aux champs électromagnétiques émis par les téléphones mobiles (300 MHz - 3 GHz)Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)33.070.01Mobilni servisi na splošnoMobile services in general13.280Varstvo pred sevanjemRadiation protectionICS:Ta slovenski standard je istoveten z:EN 50361:2001SIST EN 50361:2002en01-januar-2002SIST EN 50361:2002SLOVENSKI
STANDARD



SIST EN 50361:2002



EUROPEAN STANDARDEN 50361NORME EUROPÉENNEEUROPÄISCHE NORMJuly 2001CENELECEuropean Committee for Electrotechnical StandardizationComité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2001 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 50361:2001 EICS 33.060.01; 33.100.01English versionBasic standard for the measurement of Specific Absorption Raterelated to human exposure to electromagnetic fields from mobile phones(300 MHz - 3 GHz)Norme de base relative à la mesuredu Débit d'Absorption Spécifique relatifà l'exposition des personnes aux champsélectromagnétiques émis par lestéléphones mobiles (300 MHz - 3 GHz)Grundnorm zur Messung der SpezifischenAbsorptionsrate (SAR) in Bezug aufdie Sicherheit von Personen inelektromagnetischen Feldern vonMobiltelefonen (300 MHz bis 3 GHz)This European Standard was approved by CENELEC on 2001-07-03. CENELEC members are bound tocomply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving thisEuropean Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in anyother language made by translation under the responsibility of a CENELEC member into its ownlanguage and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,Portugal, Spain, Sweden, Switzerland and United Kingdom.SIST EN 50361:2002



EN 50361:2001- 2 -ForewordThis European Standard was prepared by the Technical Committee CENELEC TC 211,Electromagnetic fields in the human environment.The text of the draft was submitted to the Unique Acceptance Procedure and was approved byCENELEC as EN 50361 on 2001-07-03.The following dates were fixed:–latest date by which the EN has to be implementedat national level by publication of an identicalnational standard or by endorsement(dop)2002-03-01–latest date by which the national standards conflictingwith the EN have to be withdrawn(dow)2003-03-01Annexes designated "normative" are part of the body of the standard. Annexes designated "informative" are given for information only. In this standard, annex D is normative and annexes A, B and C are informative.__________SIST EN 50361:2002



- 3 -EN 50361:2001Contents1Scope.42Normative references.43Physical quantities, units and constants.43.1Physical quantities.43.2Constants.54Definitions.55Measurement system specifications.95.1General requirements.95.2Phantom specifications (shell and liquid).105.3Specifications of the SAR measurement equipment.115.4Scanning system specifications.
...