Household electric thermal storage room heaters - Methods for measuring performance

2021: CLC legacy converted by DCLab NISOSTS

Elektrische Wärmespeicher - Raumheizgeräte für den Hausgebrauch - Verfahren zur Messung der Gebrauchseigenschaften

Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de mesure de l'aptitude à la fonction

Gospodinjski termoakumulacijski grelniki - Metode za merjenje funkcionalnosti - Dopolnilo A11

Ta standard se uporablja za termoakumulacijske grelnike z dnevnim obratovalnim ciklom, ki so namenjeni ogrevanju prostora, v katerem se nahajajo.

General Information

Status
Published
Publication Date
22-Aug-2019
Withdrawal Date
16-Jun-2022
Current Stage
6060 - Document made available - Publishing
Start Date
23-Aug-2019
Due Date
28-Aug-2019
Completion Date
23-Aug-2019

Relations

Buy Standard

Amendment
EN 60531:2002/A11:2019
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2019
Gospodinjski termoakumulacijski grelniki - Metode za merjenje funkcionalnosti -
Dopolnilo A11
Household electric thermal storage room heaters - Methods for measuring performance
Elektrische Raumheizgeräte für den Hausgebrauch - Verfahren zur Messung der
Gebrauchseigenschaften
Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de
mesure de l'aptitude à la fonction
Ta slovenski standard je istoveten z: EN 60531:2000/A11:2019
ICS:
97.100.10 Električni grelniki Electric heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60531:2000/A11

NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2019
ICS 97.100
English Version
Household electric thermal storage room heaters - Methods for
measuring performance
Appareils électrodomestiques de chauffage à accumulation Elektrische Raumheizgeräte für den Hausgebrauch -
des locaux - Méthodes de mesure de l'aptitude à la fonction Verfahren zur Messung der Gebrauchseigenschaften
This amendment A11 modifies the European Standard EN 60531:2000; it was approved by CENELEC on 2019-06-17. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60531:2000/A11:2019 E

Contents Page
European foreword . 3
1 Modification to clause 1, "Scope" . 4
2 Modification to clause 2, "Normative references" . 4
3 Modification to clause 3, "Terms and Definitions" . 4
4 Modifications to clause 4, "Classification" . 8
5 Modification to clause 5, "List of measurements" . 8
6 Modifications to clause 6, "General conditions for measurements" . 8
7 Modification to clause 8, "Charge acceptance" . 9
8 Modification to clause 9, "Room heating capability" . 9
9 Modification to clause 10, "Heat retention" . 10
10 Modification of clause 13, "Stability of room temperature" . 11
11 Addition of clause 15, "Requirements to comply with functions according to the
ecodesign regulation" . 11
Annex B (normative) Climatic test room . 16
Annex D (informative) Information provided at point of sale . 17
Annex F (informative) Bibliography . 18
Annex ZZ (informative) Relationship between this European Standard and the Ecodesign
requirements of Commission Regulation EU No 2015/1188 aimed to be covered . 19
Bibliography . 20

European foreword
This document (EN 60531:2000/A11:2019) has been prepared by CLC/TC 59X/WG 12 “Electric
room heating appliances”.
The following dates are fixed:
• latest date by which this document has to (dop) 2020-03-17
be implemented at national level by
publication of an identical national standard
or by endorsement
• latest date by which the national standards (dow) 2022-06-17
conflicting with this document have to be
withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CENELEC shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association, and supports essential requirements
of EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of
this document.
The purpose of this amendment is to specify essential performance characteristics of direct
acting room heaters and to describe methods for measuring of these characteristics related to
EU Commission regulation (EU) No 2015/1188 and standardization request from the EU
Commission M/550.
1 Modification to clause 1, "Scope"
Replace by:
This standard applies to electric storage heaters having a daily operating cycle and intended
to heat the room in which they are located.
NOTE 1 This standard does not apply to heating appliances incorporated in the building structure, to
central heating systems or to floor heating installations.
NOTE 2 If an appliance is intended to be operated as a storage heater or as a direct-acting room
heater, it is also tested in accordance with EN 60675.
NOTE 3 If an appliance has a heat retention of less than 20 %, it is not considered to be a storage
heater.
This standard defines the main performance characteristics of storage heaters and specifies
methods for measuring these characteristics, for the information of users.
NOTE 4 Information which may be of interest to the consumer is listed in Annex D.
This standard does not specify values for performance characteristics.
NOTE 5 This standard does not deal with:
– safety requirements (EN 60335-2-60);
– acoustical noise of fans heaters (EN 60704-2-2).
2 Modification to clause 2, "Normative references"
Replace by:
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition cited
applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 60584-1:2013, Thermocouples - Part 1: EMF specifications and tolerances (IEC 60584-
1:2013)
3 Modification to clause 3, "Terms and Definitions"
Replace by:
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
storage local space heater
electric local space heater designed to store heat in an accumulating isolated core and to
discharge it for several hours after the accumulation phase
3.2
local space heater
space heating device that emits heat by direct heat transfer in combination with heat transfer
to a fluid, in order to reach and maintain a certain level of human comfort within an enclosed
space in which the product is situated, possibly combined with a heat output to other spaces
and is equipped with one or more heat generators that convert electricity or gaseous or liquid
fuels directly into heat, through use of the Joules effect or combustion of fuels respectively
3.3
slave heater
electric local space heater which is not capable of autonomous operation and needs to receive
signals sent from an external master controller, not being part of the product but connected to
it by pilot wire, wireless, power line communication or an equivalent technique, in order to
regulate the emission of heat into the room in which the product is installed
3.4
minimum discharge condition
condition under which the appliance is operated, the means for controlling the heat output,
such as flaps and fans, being set at the lowest position
3.5
maximum discharge condition
condition under which the appliance is operated, the means for controlling the heat output,
such as flaps and fans, being set at the highest position, any boost position being ignored
Note 1 to entry: A boost position is a setting of a control for occasional use which results in a higher temporary
fan speed.
3.6
average room temperature
arithmetic average of the maximum and minimum room temperatures for a setting of the room
temperature control
3.7
room temperature control
mechanical or electronic device, sensitive to the room temperature and adjustable by the user
3.8
amplitude
difference between the maximum and the minimum room temperatures for a setting of the room
temperature control
3.9
drift
difference between the average room temperatures obtained at different charge levels for a
setting of the room temperature control
3.10
nominal heat output
Pnom
heat output of a local space heater comprising both direct heat output and indirect heat output
(where applicable), when operating at the setting for the maximum heat output that can be
maintained over an extended period, as declared by the manufacturer, expressed in x,x kW
3.11
minimum heat output
Pmin
heat output of a local space heater comprising both direct heat output and indirect heat output
(where applicable), when operating at setting of the lowest heat output, as declared by the
manufacturer, expressed in x,x kW
3.12
maximum heat output
Pmax
declared heat output of an electric local space heater when operating at the setting of the
maximum heat output that can be maintained continuously over an extended period, as
declared by the manufacturer, expressed in x,x kW
3.13
auxiliary electricity consumption – at nominal heat output
elmax
this value is zero for electric local space heaters. All electric power consumption is included in
the nominal heat output (P )
min
3.14
auxiliary electricity consumption – at minimum heat output
el
min
this value is zero for electric local space heaters; all electric power consumption is included in
the minimal heat output (P )
min
3.15
electric power consumption in standby mode
elsb
electric power consumption of the product while in standby mode, expressed in x,xxx kW
Note 1 to entry: This is only applicable if the product has a “standby mode”. For electric local space
heaters without a standby mode the value is zero.
3.16
standby mode
state of the product where the heating function has been deactivated without disconnection
from mains or switching power off. Independent from external conditions (room temperature,
time, or control signals) the unit will not start heating; to resume the heating function a (manual)
reactivation by the user is required; in standby mode only the following functions are provided,
which may persist for an indefinite time:
— reactivation function, or reactivation function and only an indication of enabled reactivation
function, and/or
— information or status display
3.17
seasonal space heating energy efficiency
η
S
ratio between the space heating demand, supplied by a local space heater and the annual
energy consumption required to meet this demand, expressed in %; the seasonal space heating
energy efficiency is calculated using the methods described in Annex III of regulation (EU) No
2015/1188
3.18
set-back function
function which allows the room temperature to be maintained at a predefined lower value than
the pre-set (comfort) temperature without changing the setting of the room temperature control
3.19
manual heat charge control, with integrated thermostat
manually operated sensing device integrated into the product, which measures and regulates
its core temperature to vary the accumulated amount of heat
3.20
manual heat charge control with room and/or external temperature feedback
manually operated sensing device integrated into the product which measures its core
temperature and varies the accumulated amount of heat in relation with the room temperature
and/or outdoor temperature
3.21
electronic heat charge control with room and/or external temperature feedback or
regulated by energy supplier
automatically operated sensing device integrated into the product which measures its core
temperature and varies the accumulated amount of heat in relation with the room temperature
and/or outdoor temperature or a device whose charging regime can be regulated by the energy
supplier
3.22
fan assisted heat output
means the product is equipped with an integrated and controllable fan (or fans) to vary the heat
output to adjust to the heat demand
3.23
mechanical room temperature control
means the product is equipped with a non-electronic device that allows the product to
automatically vary its heat outpu
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.