97.100 - Domestic, commercial and industrial heating appliances
ICS 97.100 Details
Domestic, commercial and industrial heating appliances
Elektrische Haushaltsheizgerate
Appareils de chauffage electrique a usage domestique, industriel et commercial
Industrijska in komercialna ogrevala za dom
General Information
IEC 60704-2-18:2022 applies to single-unit electric water heaters for household and similar use intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter.
This document does not apply to:
– combustion water heaters;
– water kettles;
– heat pump water heaters;
– conventional electric storage water heaters as defined in IEC 60335-2-21:2012, Clause 1;
– instantaneous electric water heaters without any noise-producing components such as motors and pumps.
This document is intended to be used in conjunction with IEC 60704‑1:2021.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies methods for the classification and assessment of function blocks designed to operate burners and appliances burning gaseous or liquid fuels with particular regards to their fault behaviour and preventative measures.
This European Standard is applicable to new control function blocks, not covered by dedicated control standards.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft42 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the construction, safety, marking and rational use of energy.
This standard is applicable to types B11, type C11, type C31 and type C91 appliances that burn gas and:
- are closed-fronted;
- incorporate a natural draught burner;
- are connected directly to an open flue or to a device to evacuate the products of combustion (open-flued appliances, balanced-flued appliances);
- are wall mounted, free-standing or built-in;
- have a nominal heat input not exceeding 20 kW (based on the net calorific value).
This document is not applicable to:
- open fronted appliances as specified in EN 13278;
- decorative fuel effect appliances as specified in EN 509;
- catalytic combustion appliances;
- appliances in which the supply of combustion air and/or evacuation of products of combustion is achieved by mechanical means as specified in EN 1266;
- ducted-air appliances;
- appliances installed by means of a closure plate (see 3.3.3.3).
Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.
- Standard82 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft93 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft215 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to electric instantaneous water heaters for domestic hot water heating
for household and similar applications, which show both of the following characteristics:
– fulfilling at least one load pattern from Annex A;
– heating up to temperatures below the boiling temperature.
This document specifies terms, definitions and measurement methods for the assessment of
energy efficiency.
This document does not take into account requirements regarding the safety of the appliances
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to open outlet, single point-of-use, electric instantaneous water heaters
intended for household or similar use, for showering purposes without downstream mixing.
This document only specifies tests for the assessment of energy efficiency.
This document does not apply to electrical instantaneous water heaters covered by other parts
of this series of standards
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with an electric rated power > 2 kW.
This document specifies tests for the assessment of the performance.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft51 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric thermal-storage room heaters intended to heat the room in which they are located, their rated voltage being not more than 250 V for single phase and 480 V for other appliances.
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-106:2021 is available as IEC 60335-2-106:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60335-2-106:2021 deals with the safety of
- portable heated carpets;
- heated carpets and similar appliances;
- heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate,
their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.
Attention is drawn to the fact that
- in many countries different wiring rules apply;
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national authorities for fire protection, the national authorities for building regulations, the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- appliances intended exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- blankets, pads and similar flexible heating appliances (IEC 60335-2-17);
- heated mats and foot warmers with an area not exceeding 0,5 m2 (IEC 60335-2-81);
- flexible sheet heating systems permanently incorporated in the floor of the building structure (IEC 60335-2-96);
- flexible heating elements incorporated in other appliances;
- battery-operated appliances.
This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text (Clause 1, 5.2, 5.3, 5.6, 7.12.1, 7.101, 10.1, 18.101.1, 18.101.2, 18.102.5, 19.1, 19.103, 21.1, 21.104, 21.105, 30.102);
c) requirements for portable heated carpets have been added (Clause 1, 5.2, 5.5, 6.1, 6.2, 7.1, 7.6, 7.12, 7.14, 7.101, 11.8, 15.1, 15.101, 16.1, 16.2, 16.3, 19.101, 19.102. 19.103, 21.105, 21.106, 24.1.5, 24.2, 29.3);
d) requirements for washable portable heated carpets have been added (5.3, 7.1, 7.6, 7.12, 7.14);
e) the test of 30.102 has been updated.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
- Standard89 pagesEnglish and French languagesale 15% off
- Standard29 pagesEnglish and French languagesale 15% off
1.1 General
This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer.
This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically.
The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber.
The boilers may operate in condensing condition.
NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery
Directive 2006/42/EC.
This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper).
This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard.
Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This European Standard does not apply to:
heating boilers and other heating appliances which are also designed for the direct heating of the place of installation;
cooking appliances;
the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler;
room sealed applications above a nominal heat output > 70 kW or operated with positive pressure in the combustion chamber or operated under natural draught;
This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements.
This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard).
1.2 Fuels
These boilers may burn either fossil fuels, biogenic fuels or other fuels such as peat, as specified for their use by the boiler manufacturer, in accordance with the requirements of this European Standard.
Solid fuels included in this European Standard are categorised as follows.
1.2.1 Biogenic fuels
Biomass in a natural state, in the form of:
Adaptation to new fuels standards and consideration of new fuels standards in preparation.
A log wood with moisture content w ≤ 25 %, according to EN 14961-5;
B1 chipped wood (wood chipped by machine, usually up to a maximum length of 15 cm) with moisture content from w 15 % to w 35 %, according to EN 14961-4;
B2 chipped wood as under B1, except with moisture content w > 35 %;
C1 compressed wood (e.g. pellets without additives, made of wood and/or bark particles; natural binding agents such as molasses, vegetable paraffins and starch are permitted), pellets according to EN 14961-2;
(...)
- Standard98 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft95 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard12 pagesEnglish and French languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60675-3 applies to electric direct-acting room heaters.This document defines performance characteristics related to the radiant effect and specifiesmethods for measuring the radiation efficiency for the information of users.This document is used to measure the radiation efficiency of direct-acting room heaters.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
This clause of IEC 60675:1994 is applicable, with the following modification:
Replace the first paragraph with the following content:
This document applies to electric direct-acting room heaters .
This document defines performance characteristics related to the radiant effect and specifies
methods for measuring the radiant factor for the information of users.
This document is used to measure the radiant factor of direct-acting room heaters.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60675-2:2020 applies to electric direct-acting room heaters.
This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiant factor for the information of users.
This document is used to measure the radiant factor of direct-acting room heaters.
This International Standard is to be used in conjunction with IEC 60675:1994, IEC 60675:1994/AMD1:1998 and IEC 60675:1994/AMD2:2018.
- Standard37 pagesEnglish and French languagesale 15% off
IEC 60675-3:2020 applies to electric direct-acting room heaters.
This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiation efficiency for the information of users.
This document is used to measure the radiation efficiency of direct-acting room heaters.
This International Standard is to be used in conjunction with IEC 60675:1994, IEC 60675:1994/AMD1:1998 and IEC 60675:1994/AMD2:2018.
- Standard86 pagesEnglish and French languagesale 15% off
2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-08-12 CV: New assessment requested
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to electric instantaneous water heaters for domestic hot water heating for household and similar applications, which show both of the following characteristics:
– fulfilling at least one load pattern from Annex A;
– heating up to temperatures below the boiling temperature.
This European Standard specifies terms, definitions and measurement methods for the assessment of energy efficiency.
This European Standard does not take into account requirements regarding the safety of the appliances.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This clause of part 1 is applicable except as follows.
Addition:
This standard applies to open outlet, single point of use, electric instantaneous water heaters intended for household or similar use, for showering purposes without downstream mixing.
This standard only specifies tests for the assessment of energy efficiency.
This standard does not apply to electrical instantaneous water heaters covered by other parts of this series of standards.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This clause of Part 1 is applicable with the following exception:
This European Standard applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with electric rated power >2 kW.
This European Standard specifies tests for the assessment of the performance.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard8 pagesEnglish and French languagesale 15% off
- Amendment15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to electrical underfloor heating of dwellings and all other buildings whose use corresponds to dwellings or is at least similar, having a maximum load bearing in use of 4 kN/m². This European Standard defines the main characteristics of electrical underfloor heating and establishes the method of testing of these characteristics as information for the user. This European Standard does not deal with: - installation and safety requirements; DIN VDE 0100-723.
- Amendment14 pagesEnglish languagesale 10% offe-Library read for1 day
EN-IEC 60335-2-71 deals with the safety of all kinds of electrical heating appliances used for livestock rearing and breeding, such as: heat-radiating appliances, electrical sittinghens, incubators, chicken breeding units and heating plates for animals, the rated voltage of the appliances being not more than 250 V for single-phase appliances and 480 V for other appliances.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
EN-IEC 62282-8-201 defines the evaluation methods of typical performances for electricenergy storage systems using hydrogen. This is applicable to the systems that useelectrochemical reaction devices for both power charge and discharge. This document appliesto systems that are designed and used for service and operation in stationary locations (indoorand outdoor).The conceptual configurations of the electric energy storage systems using hydrogen are shownin Figure 1 and Figure 2. Figure 1 shows the system independently equipped with an electrolysermodule and a fuel cell module. Figure 2 shows the system equipped with a reversible cellmodule. There are an electrolyser, a hydrogen storage and a fuel cell, or a reversible cell, ahydrogen storage and an overall management system (which may include a pressuremanagement) as indispensable components. There may be a battery, an oxygen storage, a heatmanagement system (which may include a heat storage) and a water management system(which may include a water storage) as optional components. The performance measurement isexecuted in the area surrounded by the outside thick solid line square (system boundary).NOTE In the context of this document, the term "reversible" does not refer to the thermodynamic meaning of an idealprocess. It is common practice in the fuel cell community to call the operation mode of a cell that alternates betweenfuel cell mode and electrolysis mode "reversible".This document is intended to be used for data exchanges in commercial transactions betweenthe system manufacturers and customers. Users of this document can selectively execute testitems suitable for their purposes from those described in this document.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-71:2018 deals with the safety of all kinds of electrical heating appliances used for livestock rearing and breeding, such as: heat-radiating appliances, electrical sitting-hens, incubators, chicken breeding units and heating plates for animals, the rated voltage of the appliances being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard applies to heating appliances used for livestock rearing and breeding that include an electrical motor. This standard does not apply to: - appliances designed exclusively for industrial purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - heating units embedded in the floor; - flexible sheet heating elements for room heating (IEC 60335-2-96); - room heaters (IEC 60335-2-30). This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2012). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - two paragraphs are deleted (Introduction); - normative references updated (Clause 2); - colour required for symbols (7.6); - some notes converted to normative text (19.2, 21.101, 22.104).
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with the safety of electric thermal-storage room heaters intended to heat the room in which they are located, their rated voltage being not more than 250 V for single phase and 480 V for other appliances.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances".
This European Standard applies to Type A2, A3, B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net cv basis), intended for use in single unit residential dwellings and in other than single unit residential units. Provision of the heated air may be by means of ducting.
This European Standard does not apply to:
a) dual purpose air conditioning appliances (heating and cooling);
b) appliances where the air is heated by an intermediate fluid;
c) portable or transportable forced convection appliances;
d) domestic appliances for outdoor installation;
e) appliances fitted with manual or automatic means of adjusting the combustion products evacuation by means of flue dampers;
f) appliances having multiple heating units with a single draught diverter;
g) appliances fitted with more than one flue outlet;
h) appliances fitted with gas boosters;
i) domestic appliances of type C22, C23, C42, C43, C52 and C53;
j) C21 and C41 appliances for 3rd family gases;
NOTE For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated.
This European Standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals.
- Standard193 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, rational use of energy, classification and marking of non-domestic gas-fired overhead luminous radiant heaters for environmental comfort, referred to in the body of the text as "appliances".
This European Standard is applicable to Type A1 and Type A3 appliances only (see 4.2.2) intended for use in other than residential dwellings:
a) low gas pressure appliances operating at pressures up to and including 50 mbar;
b) medium gas pressure appliances operating at pressures above 50 mbar and up to 2 bar.
This European Standard is not applicable to:
- appliances designed for use in domestic dwellings;
- outdoor appliances;
- appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference gas);
This standard is applicable to appliances which are intended to be type tested.
- Standard114 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant strips heaters and multi-burner continuous radiant tube heater systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.
For radiant strip heaters incorporating a single burner, this standard is applicable to Type B22, B23, B52, B53, C12, C13, C32, C33 C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
For multi-burner continuous radiant tube heater systems this standard is applicable to type B22, B52, and C52 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
This standard also includes appliances incorporating a secondary heat exchanger in the flue system.
This standard is not applicable to:
a) appliances designed for use in domestic dwelling;
b) outdoor appliances;
c) radiant strip heaters where the heat input is in excess of 300 KW (based on the net calorific value of the appropriate reference test gas);
d) continuous radiant tube heater systems where the heat input of any individual burner unit is in excess of 70 kW (based on the net calorific value of the appropriate reference test gas);
e) appliances having combustion products evacuation ducts that are non-metallic in the flue system – except ducts downstream of a possible additional condensing exhaust gas heat exchanger.
In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to:
f) appliances that are designed for continuous condensation within the flue system under normal operating conditions – except downstream a possible additional exhaust gas heat exchanger.
This standard is applicable to appliances which are intended to be type tested.
- Standard162 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard162 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant tube heaters incorporating a single burner and multiple burner systems (referred to in the body of the text as the "system") with each burner unit under the control of an automatic burner control system.
For radiant tube heaters incorporating a single burner, this standard is applicable to Type A2, A3, B12, B13, B22, B23, B42, B43, B52, B53, C12, C13, C32, C33, C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means located upstream of the draught diverter, if provided.
For radiant tube heater systems incorporating multiple tube heater segments, this standard is applicable to Type B52, B52x, B53 and B53x systems intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
This standard also includes appliances incorporating a secondary heat exchanger in the flue system.
This standard is not applicable to:
a) appliances designed for use in domestic dwelling;
b) outdoor appliances;
c) appliances where the heat input of any individual burner unit is in excess of 120 kW (based on the net calorific value of the appropriate reference test gas);
d) appliances having combustion products evacuation ducts that are non-metallic in the flue system - except ducts downstream of a possible additional condensing exhaust gas heat exchanger.
In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to:
e) appliances and systems that are designed for continuous condensation within the flue system under normal operating conditions - except downstream a possible additional exhaust gas heat exchanger.
This standard is applicable to systems which are intended to be type tested.
- Standard167 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, fitness
for purpose, rational use of energy and the marking of a micro combined heat and power appliance;
(hereafter referred to as “mCHP appliance”).
This European Standard applies to mCHP appliances of types B22, B23, B32, B33, B52, B53, C1, C3, C42, C43
C52, C53, C62, C63, C82, C83 and C9 based on the classifications of CEN/TR 1749:
– that use one or more supplied gases of the three gas families at the pressures stated in EN 437,
– where the temperature of the heat transfer fluid of the heating system (heating water circuit) does
not exceed 105 ºC during normal operation,
– where the maximum operating pressure in the
- heating water circuit does not exceed 6 bar,
- domestic hot water circuit (if installed) does not exceed 10 bar,
– which are either intended to be installed indoors or outdoors in a partially protected place,
– which are intended to produce hot water either by the instantaneous or storage principle,
– which have a maximum heat input (based on net calorific value) not exceeding 70 kW,
– which are designed for sealed or open water systems.
NOTE 1 For applications where the maximum allowable water temperature exceeds 110 ºC or where volume multiplied by
maximum allowable pressure exceeds 50 bar litres, further requirements may be necessary to comply with the essential
requirements of Directive 97/23/EC (Pressure Equipment Directive (PED)).
NOTE 2 For mCHP appliances with constructions that might not be fully covered by this European Standard or by another specific
standard, the risk associated with the alternative construction will be assessed.
NOTE 3 prEN 13203-4 will specify the assessment of energy consumption for domestic hot water production of gas combined
heat and power appliances (mCHP).
This European Standard does not contain the requirements necessary for appliance capable of producing
electrical energy without using the thermal energy.
This European Standard does not cover all the requirements for mCHP appliances that are intended to be
connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the
lifetime of the appliance (see Annex DD).
- Amendment28 pagesEnglish languagesale 10% offe-Library read for1 day
2019-01-10 AJC: Document uploaded to HAS platform for FV stage following failed original upload. New HAS deadline: 2019-02-14. Following reception of results, document will progress.
2017-07-17 CP: negative assessment recived - UAP cancelled
2021: CLC legacy converted by DCLab NISOSTS
- Amendment28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, rational use of energy, classification and marking of non-domestic gas-fired overhead luminous radiant heaters for environmental comfort, referred to in the body of the text as "appliances".
This European Standard is applicable to Type A1 and Type A3 appliances only (see 4.2.2) intended for use in other than residential dwellings:
a) low gas pressure appliances operating at pressures up to and including 50 mbar;
b) medium gas pressure appliances operating at pressures above 50 mbar and up to 2 bar.
This European Standard is not applicable to:
- appliances designed for use in domestic dwellings;
- outdoor appliances;
- appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference gas);
This standard is applicable to appliances which are intended to be type tested.
- Standard114 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances".
This standard also applies to warm air heaters having forced draught burners.
This European Standard applies to Type A2, A3 appliances, with an input not exceeding 300 kW (net CV basis), intended for non-domestic use.
This European Standard also applies to Type B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net CV basis), intended for domestic and non-domestic use.
Provision of the heated air may be by means of ducting.
This European Standard does not apply to:
a) dual purpose air conditioning appliances (heating and cooling);
b) appliances where the air is heated by an intermediate fluid;
c) portable or transportable forced convection appliances;
d) appliances fitted with manual or automatic means of adjusting the combustion products evacuation by means of flue dampers;
e) appliances having multiple heating units with a single draught diverter;
f) appliances fitted with more than one flue outlet;
g) appliances fitted with gas boosters;
h) C21 and C41 appliances for 3rd family gases.
NOTE For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated.
This European Standard is not intended to cover appliances projected for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance.
This European Standard is applicable to appliances which are intended to be type tested.
- Standard193 pagesEnglish languagesale 10% offe-Library read for1 day
This standard spplies to electric storage heaters having a daily operating cycle and intended to heat the room in which they are located.
- Amendment20 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to electric direct-acting room heaters. They may be portable, stationary, fixed, or built-in.
It does not apply to:
- thermal-storage room heaters (EN 60531);
- heating appliances incorporated in the building structure;
- central heating systems;
- heaters connected to an air duct;
- wall-paper, carpets or drapes incorporating flexible heating elements;
- sauna stoves.
This standard defines the main performance characteristics of direct-acting room heaters and specifies methods for measuring these characteristics, for the information of users.
This standard does not specify values for performance characteristics.
NOTE:
- This standard does not deal with:
- safety requirements (EN 60335-2-30);
- acoustical noise of fan heaters (EN 60704-2-2).
- Amendment25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant tube heaters incorporating a single burner and multiple burner systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.
For radiant tube heaters incorporating a single burner, this standard is applicable to Type A2, A3, B12, B13, B22, B23, B42, B43, B52, B53, C12, C13, C32, C33, C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means located upstream of the draught diverter, if provided.
For radiant tube heater systems incorporating multiple tube heater segments, this standard is applicable to Type B52, B52x, B53 and B53x systems intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
This standard also includes appliances incorporating a secondary heat exchanger in the flue system.
This standard is not applicable to:
a) appliances designed for use in domestic dwelling;
b) outdoor appliances;
c) appliances where the heat input of any individual burner unit is in excess of 120 kW (based on the net calorific value of the appropriate reference test gas);
d) appliances having combustion products evacuation ducts that are non-metallic in the flue system - except ducts downstream of a possible additional condensing exhaust gas heat exchanger.
In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to:
e) appliances and systems that are designed for continuous condensation within the flue system under normal operating conditions - except downstream a possible additional exhaust gas heat exchanger.
This standard is applicable to systems which are intended to be type tested.
- Standard167 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant strips heaters and multi-burner continuous radiant tube heater systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.
For radiant strip heaters incorporating a single burner, this standard is applicable to Type B22, B23, B52, B53, C12, C13, C32, C33 C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
For multi-burner continuous radiant tube heater systems this standard is applicable to type B22, B52, and C52 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
This standard also includes appliances incorporating a secondary heat exchanger in the flue system.
This standard is not applicable to:
a) appliances designed for use in domestic dwelling;
b) outdoor appliances;
c) radiant strip heaters where the heat input is in excess of 300 KW (based on the net calorific value of the appropriate reference test gas);
d) continuous radiant tube heater systems where the heat input of any individual burner unit is in excess of 70 kW (based on the net calorific value of the appropriate reference test gas);
e) appliances having combustion products evacuation ducts that are non-metallic in the flue system – except ducts downstream of a possible additional condensing exhaust gas heat exchanger.
In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to:
f) appliances that are designed for continuous condensation within the flue system under normal operating conditions – except downstream a possible additional exhaust gas heat exchanger.
This standard is applicable to appliances which are intended to be type tested.
- Standard162 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard162 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to electric direct-acting room heaters. They may be portable, stationary, fixed, or built-in. It does not apply to: - thermal-storage room heaters (EN 60531); - heating appliances incorporated in the building structure; - central heating systems; - heaters connected to an air duct; - wall-paper, carpets or drapes incorporating flexible heating elements; - sauna stoves. This standard defines the main performance characteristics of direct-acting room heaters and specifies methods for measuring these characteristics, for the information of users. This standard does not specify values for performance characteristics. NOTE: - This standard does not deal with: - safety requirements (EN 60335-2-30); - acoustical noise of fan heaters (EN 60704-2-2).
- Amendment25 pagesEnglish languagesale 10% offe-Library read for1 day
2021: CLC legacy converted by DCLab NISOSTS
- Amendment20 pagesEnglish languagesale 10% offe-Library read for1 day
2019-01-16 CV: LVD assessment uploaded on HAS tool on 2018-12-29 (deadline: 2019-02-04). If positively assessed, project can proceed to BT (1 month consultation) for the approval of the new Annex ZZ
2017-05-02: D156/C084 - Ratified standards not being made available.
2017-09-07: publication pending due to missing Annex ZZ
2021: CLC legacy converted by DCLab NISOSTS
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-96:2019 is available as IEC 60335-2-96:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60335-2-96:2019 deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.
Flexible sheet heating elements are converted into heating units that are incorporated in the building in accordance with the instructions after which the required level of protection against hazards is achieved. Attention is drawn to the fact that:
– in many countries, different wiring rules apply;
– for heating units intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national authorities for fire protection, the national authorities for building regulations, the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to:
– heating units intended exclusively for industrial purposes;
– heating units intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– blankets, pads, clothing and similar flexible heating appliances (IEC 60335-2-17);
– foot warmers and heating mats (IEC 60335-2-81);
– heated carpets and for heating units for room heating installed under removable floor coverings (IEC 60335-2-106);
– flexible sheet heating elements incorporated in other appliances.
This second edition cancels and replaces the first edition published in 2002, Amendment 1:2003 and Amendment 2: 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the first edition:
– aligns the text with IEC 60335-1:2010, and its Amendments 1 and 2;
– some notes have been converted to normative text or deleted (5.6, 7.12.1, 10.1, 11.2.103, 13.1, 13.2, 16.2, 16.3, 18.101, 18.102.5, 21.1, 22.103, 22.105, 22.106);
– the strength test for heating units incorporating insulated wires intended to be installed in floors has been modified a (21.103);
– the scope and specific requirements have been added for heating units installed in walls below a height of 1,2 m (6.2, 7.1, 7.12.1, 7.12.6, 7.101, 11.2, 19.2, 22.106, 24.102, Annex AA).
- Standard100 pagesEnglish and French languagesale 15% off
IEC TS 63070:2019 is applicable to ultrasonic equipment designed for the medical field of application. It covers both diagnostic and therapeutic (physiotherapy and HITU) equipment.
This document describes transducer evaluation by the infrared imaging technique using a split TMM-phantom for qualitative and quantitative estimation of temperature distributions in tissue-mimicking material, resulting from absorption of ultrasound and from heating of the transducer itself.
This document also describes a method to measure transducer-surface temperature, while the transducer is driven under the still-air condition.
- Technical specification26 pagesEnglish languagesale 15% off
This standard applies to electric direct -acting room heaters. They may be portable,
stationary, fixed, or built-in.
It does not apply to:
— thermal-storage room heaters (IEC 531);
- heating appliances incorporated in the building structure;
- central heating systems;
— heaters connected to an air duct;
- wall-paper, carpets or drapes incorporating flexible heating elements.
This standard defines the main performance characteristics of direct-acting room
heaters and specifies methods for measuring these characteristics, for the information of
users.
This standard does not specify values for performance characteristics.
NOTE - This standard does not deal with:
- safety requirements (IEC 335-2-30);
acoustical noise of fan heaters (IEC 704-2-2).
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to electric direct -acting room heaters. They may be portable,
stationary, fixed, or built-in.
It does not apply to:
— thermal-storage room heaters (IEC 531);
- heating appliances incorporated in the building structure;
- central heating systems;
— heaters connected to an air duct;
- wall-paper, carpets or drapes incorporating flexible heating elements.
This standard defines the main performance characteristics of direct-acting room
heaters and specifies methods for measuring these characteristics, for the information of
users.
This standard does not specify values for performance characteristics.
NOTE - This standard does not deal with:
- safety requirements (IEC 335-2-30);
acoustical noise of fan heaters (IEC 704-2-2).
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, performance (efficiency and emission), safety, instructions and marking together with associated test methods and test fuels for type testing residential independent boilers fired by solid fuel.
This standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn either solid mineral fuels, peat briquettes or natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This standard is also not applicable to the design and construction of automatic stoking devices.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard48 pagesGerman languagesale 10% offe-Library read for1 day