97.100 - Domestic, commercial and industrial heating appliances
ICS 97.100 Details
Domestic, commercial and industrial heating appliances
Elektrische Haushaltsheizgerate
Appareils de chauffage electrique a usage domestique, industriel et commercial
Industrijska in komercialna ogrevala za dom
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 97.100 - Domestic, commercial and industrial heating appliances
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This part of IEC 60704 applies to electric fan heaters, designed for placing on the floor, table
or counter, etc., or for mounting.
This document does not apply to
– electric storage room heaters;
– room humidifiers;
– room dehumidifiers;
– air cleaners;
– heaters designed exclusively for industrial purposes.
For determining and verifying noise emission values declared in product specifications, refer
to IEC 60704-3:2019.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60704-2-2:2023 is available as IEC 60704-2-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-2-2:2023 applies to electric fan heaters, designed for placing on the floor, table or counter, etc., or for mounting. This document does not apply to: - electric storage room heaters; - room humidifiers; - room dehumidifiers; - air cleaners; - heaters designed exclusively for industrial purposes. For determining and verifying noise emission values declared in product specifications, refer to IEC 60704-3:2019. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with the latest edition of IEC 60704-1:2021, - addition of several ISO standards, - revision of built-in-conditions, - addition of requirements on climatic conditions and on background noise. This part 2-2 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements. This part 2-2 supplements or modifies the corresponding clauses in IEC 60704-1:2021.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60704-2-2:2023 is available as IEC 60704-2-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60704-2-2:2023 applies to electric fan heaters, designed for placing on the floor, table or counter, etc., or for mounting. This document does not apply to:
- electric storage room heaters;
- room humidifiers;
- room dehumidifiers;
- air cleaners;
- heaters designed exclusively for industrial purposes.
For determining and verifying noise emission values declared in product specifications, refer to IEC 60704-3:2019. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- alignment with the latest edition of IEC 60704-1:2021,
- addition of several ISO standards,
- revision of built-in-conditions,
- addition of requirements on climatic conditions and on background noise.
This part 2-2 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
This part 2-2 supplements or modifies the corresponding clauses in IEC 60704-1:2021.
- Standard40 pagesEnglish languagesale 15% off
- Standard58 pagesEnglish languagesale 15% off
- Standard98 pagesEnglish languagesale 15% off
- Standard98 pagesEnglish languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
This document specifies, the requirements and tests methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid products.
The hybrid product is composed by:
- a gas boiler as heat generator which could supply the heat demand in all operating conditions;
- an electrical heat pump, as heat generator, which has not to fulfil the heat demand in all operating conditions;
- a control unit (see definition 3.10).
The gas boiler as part of the hybrid product covered by this document is a gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020:
a) that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which shall be classified as gas boiler;
f) which are intended to be installed either indoors or outdoors in a partially protected place;
g) which may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit;
h) which are designed for either sealed water systems or for open water systems.
This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11.
This document does not cover all the requirements for:
Appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex DD);
a) appliances using flue dampers;
b) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81;
c) appliances incorporating flexible plastic flue liners;
d) appliances designed to become connected to a combined flue duct system that is designed to operate under overpressure (for example Ca)).
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the manufacturer when used for space heating and/or DHW production.
This part specifies the common requirements and test methods concerning, in particular the construction, safety, fitness for purpose, and rational use of energy.
This document is to be used in conjunction with:
a) the gas fired boiler, the generic part EN 15502-1 and specific Part 2-1 and Part 2-2.
b) the electrical heat pump, EN 14511-4:2018, EN 378-1:2016 to EN 378-4:2016+A1:2019 and FprEN 14825:2020.
c) electrical safety, EN 60335-1:2019, EN 60335-2-102:2016, EN 60335-2-40:2012, EN 60335-2-40/A2:2009 and EN 60204-1.
d) for domestic hot water production, EN 13203-5.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the corrigendum of March 2017 have been included in this copy.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and similar locations. This standard also deals with the safety of electric sauna heating appliances provided with a humidifier unit, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The room air is humidified by evaporating or atomising water. This fourth edition cancels and replaces the third edition published in 2002 and its Amendment 1 (2007). It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-53 are as follows: - the scope is changed to cover infrared cabins; - additional requirements for recessed sauna heaters are added; - requirements of electronic interlocks are added (22.108). The attention of National Committees is drawn to the fact that equipment organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. This publication is to be read in conjunction with IEC 60335-1:2010.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
This standard deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
This standard deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and similar locations. This standard also deals with the safety of electric sauna heating appliances provided with a humidifier unit, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The room air is humidified by evaporating or atomising water. This fourth edition cancels and replaces the third edition published in 2002 and its Amendment 1 (2007). It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-53 are as follows: - the scope is changed to cover infrared cabins; - additional requirements for recessed sauna heaters are added; - requirements of electronic interlocks are added (22.108). The attention of National Committees is drawn to the fact that equipment organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. This publication is to be read in conjunction with IEC 60335-1:2010.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the corrigendum of March 2017 have been included in this copy.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
NEXT ACTION: TB ACTION by 2021-01-31 (TC to send text after drop of voting results - D167/C064)
HAS ASSESSMENT BY 2019-09-27
2019-01-23 CV: blocked until ratification of pr64193 is completed
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-81:2015 deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. It also does not take into account children playing with the appliance. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2011). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-81 are as follows (minor changes are not listed):
- requirements for washable appliances (5.3, 7.1, 7.6, 7.12);
- requirements for controls in flexible cords (15.1.1, 24.2) and requirements for appliance inlets (22.105, 24.1.5, 29.1.3). The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
Key words: Foot warmer, heating element, heating mat
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
NEXT ACTION: TB ACTION by 2021-01-31 (TC to send text after drop of voting results - D167/C064)
HAS ASSESSMENT BY 2019-09-27
2019-01-23 CV: blocked until ratification of pr64193 is completed
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) are of individual one-off construction design. The standard can be used for log wood fired Kachelöfen (tile stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg and a storage period (nominal heating time) between 8 h and 24 h.
This standard is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) equipped with fireclay as interior material, with an apparent density between 1,750 kg/m³ and 2,200 kg/m³, a degree of porosity from 18 % up to 33 % by volume and a heat conductivity from 0,65 W/mK up to 0,90 W/mK (temperature range 20 °C to 400 °C).
This standard is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) with sidewise combustion air supply of the combustion chamber and an inflow speed from 2 m/s to 4 m/s, whereas the height of the lowest opening is at least 5 cm above the bottom of the combustion chamber.
This standard is not valid for combinations with water heat exchangers for central heating or other heat absorbing elements like glass plates greater than 1/6 of the combustion chamber surface, open water tanks, etc. It is also not valid for combinations with heating/fireplace elements according to EN 13229. Furthermore this standard is not valid for mass-produced prefabricated or partly prefabricated slow heat release appliances according to EN 15250.
NOTE Although for the purposes of this standard these calculations are applicable only to the requirements of this standard, the same calculations can be used for other purposes, e.g. to verify emission levels and energy efficiency in case of burning log wood or wood briquettes according to the producer’s manual.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
The application of the calculations of this document enables a verification of the emission values carbon monoxide, nitrogen dioxide, organically bound carbon as well as dust and the energy efficiency.
Complying with the calculations of this document results in emission values less or equal for carbon monoxide 1 500 mg/mn3 (1 000 mg/MJ), nitrogen dioxide 225 mg/mn3 (150 mg/MJ), organically bound carbon 120 mg/mn3 (80 mg/MJ) and dust 90 mg/mn3 (60 mg/MJ). If the calculations of this document are used in combination with suitable combustion chambers that prove lower emission values in a type test, these values are also considered to be complied with.
The user shall be aware that there might be national or local regulations, which impose stricter legal emissions and/or efficiency requirements.
This document specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) are of individual one-off construction design. The document can be used for log wood fired Kachelgrundöfen/Putzgrundöfen (tiled/plastered stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg (log wood with water content from 12 % to 20 %, thickness of 5 cm to 10 cm in diameter, length varies usually from 25 cm to 50 cm, and is oriented toward the combustion chamber dimensions) and a storage period (nominal heating time) between 8 h and 24 h.
This document is applicable for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) equipped with fireclay as interior material, with an apparent density between 1,750 kg/m3 and 2,300 kg/m3, a degree of porosity from 17 % up to 33 % by volume and a heat conductivity from 0,90 W/mK up to 1,35 W/mK (temperature range 20 °C to 400 °C).
This document is applicable for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) with combustion air supply from the side via a firebox door frame or the standing grate of the heating door into the combustion chamber. The document is applicable for an inflow speed of the combustion air between 2 m/s and 4 m/s.
This document also applies to the combination with combustion chambers that are suitable for one-off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) and for which compliance with the legally required emission values has been verified as part of a type test by an accredited and/or notified body.
The following general conditions apply to such combustion chambers:
- with an air-fuel ratio of between 1,95 and 3,95 according to the type test;
- with a maximum load from 5 kg to 40 kg;
- using other suitable materials as well as fireclay.
With regard to the type test, this document is applicable for combustion chambers which are tested:
- according to EN 15250 (or prEN 16510-2-5);
- according to EN 13229 (or prEN 16510-2-2); or
- according to respective national standards (e.g. ÖNORM B 8303).
This document is applicable for type tested combustion chambers designed for batch fired pellet burning if meeting the requirements according to this document (air-fuel ratio between 1,95 and 3,95, the load of the pellets shall be burned in (78 ± 20) min).
This document is not applicable for:
- combinations with water heat exchangers for central heating or other heat absorbing elements like open water tanks etc.;
- combustion chambers with glass plates greater than 1/5 of the combustion chamber surface;
- mass-produced prefabricated stoves (slow heat release appliances) or partly prefabricated stoves (slow heat release appliances) according to EN 15250 (or prEN 16510-2-5).
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-71:2018 deals with the safety of all kinds of electrical heating appliances used for livestock rearing and breeding, such as: heat-radiating appliances, electrical sitting-hens, incubators, chicken breeding units and heating plates for animals, the rated voltage of the appliances being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard applies to heating appliances used for livestock rearing and breeding that include an electrical motor. This standard does not apply to: - appliances designed exclusively for industrial purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - heating units embedded in the floor; - flexible sheet heating elements for room heating (IEC 60335-2-96); - room heaters (IEC 60335-2-30). This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2012). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - two paragraphs are deleted (Introduction); - normative references updated (Clause 2); - colour required for symbols (7.6); - some notes converted to normative text (19.2, 21.101, 22.104).
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-08-12 CV: New assessment requested
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to residential solid fuel burning appliances.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as appliance(s)) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This European Standard also covers CO, NOx, OGC and particulate matter (PM / PME - see Annex F) emission test methods, however this European Standard does not contain any values for the limit on these emissions.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.This European Standard is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This European Standard is not applicable to appliances with a boiler intended for water systems having
- water temperatures above 110 °C and/or an operating pressure of more than 3 bar;
- direct contact with sanitary hot water.
This European Standard does not cover appliances to be operated with ventilating systems which are intended to operate with pressure below - 15 Pa in the room of installation of the appliance in relation to the outside atmosphere.
This European Standard does not cover appliances intended to carry the load of a chimney.
- Standard164 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-3 of EN 16510 is applicable to hand fired residential cookers whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions:
− wood logs
− compressed untreated wood
− wood pellets
− solid mineral fuels
− peat briquettes.
This Part 2-3 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fired.
This Part 2-3 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-2 of EN 16510 is applicable to hand fed solid fuel fired inset appliances, with or without functional modification, that operate without firedoors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel. The surround of these appliances are integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure. These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating.
These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions.
This Part 2-2 of EN 16510 also covers ‘Kachelofen’ and ‘Putzofen’ inset appliances, having nominal heat outputs up to 15 kW.prEN 16510-1
This Part 2-2 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this Part 2-2 of EN 16510.
This Part 2-2 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-6 of a European Standard series shall be applicable to space heaters, inset appliances and cookers fired by wood pellets, mechanically fed up to 50 kW nominal heat output. These appliances typically use auxiliary energy which is measured in this standard as well.
For inset pellet appliances and especially their testing, additional information is necessary from prEN 16510 2 2.
For pellet cookers and especially their testing, additional information is necessary from prEN 16510 2 3.
Non mechanically fed appliances burning solid mineral fuels, peat briquettes and natural or manufactured wood logs are not included in this European Standard, but are covered by prEN 16510 2 1 to prEN 16510 2 5.
NOTE These appliances may have an integral fuel hopper or be combined with an external fuel hopper.
This European Standard should be used in conjunction with prEN 16510-1.
The appliances covered by this part 2-6 provide heat into the space where they are installed. They may be operated with either natural draught or fan-assisted combustion air. Where fitted with a boiler, they can also provide domestic hot water and/or central heating. These appliances burn wood pellets only, in accordance with the appliance manufacturer's instructions. They only operate with the firedoors closed.
NOTE A fan-assisted appliance does still operate under negative pressure in the flue gas system.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emissions), instructions and marking together with associated test methods and test fuels.
This European Standard shall not applicable to appliances:
— with boiler intended for water systems having water temperatures above 110°C and 3 bar; and
— with boiler intendend for water systems having direct contact with sanitary hot water;
— intended to be used with a pure horizontal exhaust (through the building wall);
— with flue gas condensation in the appliance;
— switching on / off for part load operation.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-1 of EN 16510 is applicable to freestanding or inset roomheaters fired by solid fuel, without functional modification that operate with fire doors either as closed only or as closed or open.
The appliances covered by this Part 2-1 of EN 16510 provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions: .
wood logs
compressed untreated wood
wood pellets
solid minearal fuels
peat briquettes.
This Part 2-1 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This Part 2-1 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-4 of EN 16510 is applicable to hand and automatically fired residential independent boilers having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation.
The appliances covered by this Part 2-4 of EN 16510 may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions: .
wood logs
compressed untreated wood
wood pellets
solid mineral fuels
peat briquettes.
This Part 2-4 of EN 16510 is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This Part 2-4 of EN 16510 is also not applicable to the design and construction of automatic stoking devices.
This Part 2-4 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 General
This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer.
This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically.
The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber.
The boilers may operate in condensing condition.
NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery
Directive 2006/42/EC.
This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper).
This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard.
Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This European Standard does not apply to:
heating boilers and other heating appliances which are also designed for the direct heating of the place of installation;
cooking appliances;
the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler;
room sealed applications above a nominal heat output > 70 kW or operated with positive pressure in the combustion chamber or operated under natural draught;
This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements.
This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard).
1.2 Fuels
These boilers may burn either fossil fuels, biogenic fuels or other fuels such as peat, as specified for their use by the boiler manufacturer, in accordance with the requirements of this European Standard.
Solid fuels included in this European Standard are categorised as follows.
1.2.1 Biogenic fuels
Biomass in a natural state, in the form of:
Adaptation to new fuels standards and consideration of new fuels standards in preparation.
A log wood with moisture content w ≤ 25 %, according to EN 14961-5;
B1 chipped wood (wood chipped by machine, usually up to a maximum length of 15 cm) with moisture content from w 15 % to w 35 %, according to EN 14961-4;
B2 chipped wood as under B1, except with moisture content w > 35 %;
C1 compressed wood (e.g. pellets without additives, made of wood and/or bark particles; natural binding agents such as molasses, vegetable paraffins and starch are permitted), pellets according to EN 14961-2;
(...)
- Standard103 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air.
NOTE A fan-assisted appliance does still operate under negative pressure in the flue gas system.
These appliances burn wood pellets only as specified. They only operate with the firedoors closed.
This document is not applicable to appliances:
- with boiler intended for water systems having water temperatures above 110 °C and 3 bar;
- with boiler intended for water systems having direct contact with sanitary hot water;
- intended to be used with a pure horizontal exhaust (through the building wall);
- with flue gas condensation in the appliance;
- switching on/off for part load operation.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of mechanical by wood pellets fed roomheaters, inset appliances and cookers.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to residential solid fuel burning appliances of which the nominal space heat output is more than 6 % of the combined nominal space heat output and nominal water heat output (total heat output).
This document specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as “appliance(s)”) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity, i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This document specifies CO, NOx, OGC and particulate matter (PM) emission test methods.
This document is as well applicable to appliances intended to carry the load of a chimney.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.
This document is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This document is not applicable to appliances with a boiler intended for water systems having:
- water temperatures above 110 °C and/or an operating pressure of more than 300 kPa (3 bar);
- direct contact with sanitary hot water.
This document is not applicable to appliances to be operated with ventilating systems which are intended to operate with pressure below -15 Pa in the room of installation of the appliance in relation to the outside atmosphere.
- Standard164 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to roomheaters for solid fuel (freestanding or inset solid fuel burning local space heating products that operate with fire doors either as closed only or as closed or open; insets without functional modification).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning roomheaters.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
- appliances for hot water only production and heat output < 5 kW;
- automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to electronic control equipment for heating systems with direct electrical emission, which have an integrated outside compensated function and or optimum start/stop function.
This control equipment controls the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.
This European Standard also covers controllers that contain an integrated optimum start or an optimum start-stop control function. The controller modulates heating or control modes of electronic individual zone or emitter control equipment.
Safety requirements on heating systems remain unaffected by this standard. The dynamic behaviour of the local thermostats, sensors, or actuators is not covered in this standard.
A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this standard.
Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000-1.
NOTE 1 In CEN ISO/TR 52000-2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation.
NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to electronic control equipment for heating systems with direct electrical emission, which have an integrated outside compensated function and or optimum start/stop function.
This control equipment controls the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.
This document is also applicable to controllers that contain an integrated optimum start or an optimum start-stop control function. The controller modulates heating or control modes of electronic individual zone or emitter control equipment.
Safety requirements on heating systems remain unaffected by this document. The dynamic behaviour of the local thermostats, sensors, or actuators is not covered in this document.
A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this document.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
2019-01-10 AJC: Document uploaded to HAS platform for FV stage following failed original upload. New HAS deadline: 2019-02-14. Following reception of results, document will progress.
2017-07-17 CP: negative assessment recived - UAP cancelled
2021: CLC legacy converted by DCLab NISOSTS
- Amendment28 pagesEnglish languagesale 10% offe-Library read for1 day
This standard deals shavers, hair clippers and similar appliances for domestic use
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-81:2015 deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. It also does not take into account children playing with the appliance. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2011). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-81 are as follows (minor changes are not listed): - requirements for washable appliances (5.3, 7.1, 7.6, 7.12); - requirements for controls in flexible cords (15.1.1, 24.2) and requirements for appliance inlets (22.105, 24.1.5, 29.1.3). The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication. Key words: Foot warmer, heating element, heating mat
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard also deals with the safety of electric heaters intended for the heating of driver and passenger compartments of motor vehicles when they are stationary, their rated voltage being not more than 250 V.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
2021-06-03: This prAD includes common mods to EN 60335-2-30:2009/A2 (PR=74100)
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
2021-06-03: This prAD includes common mods to EN 60335-2-30:2009/A2 (PR=74100)
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard also deals with the safety of electric heaters intended for the heating of driver and passenger compartments of motor vehicles when they are stationary, their rated voltage being not more than 250 V.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the safety, design, construction, performance requirements and testing of Temperature Control Functions (TCF) and Combustion Product Discharge Safety Devices (TTB) for gas and liquid fuel burners and appliances burning one or more gaseous or liquid fuels, hereafter referred to as ‘TCF’ or ‘TTB’.
It also describes the test procedures for checking compliance with these requirements.
This document is applicable to AC and DC supplied TCF and TTB (for TCF and TTB supplied by stand-alone battery system, battery systems for mobile applications or systems which are intended to be connected to DC supply networks, see Annex I).
This document is applicable to electronically based TTB and TCF only.
For both TTB and TCF, the requirements in this document are applicable to the combination of sensing element and control.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the safety, design, construction and performance requirements for Temperature Control Function (TCF) and Combustion Product Discharge Safety Device (TTB) intended for use with burners and appliances using gaseous or liquid fuels.
It also describes the test procedures for checking compliance with these requirements.
This European Standard is applicable to AC and DC supplied TCF and TTB (for TCF and TTB supplied by stand-alone battery system, battery systems for mobile applications or systems which are intended to be connected to DC supply networks, see Annex I).
This European Standard is applicable to electronically based TTB and TCF only.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines procedures for determining the standard thermal outputs and other characteristics of radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source. This document specifies the laboratory arrangements and testing methods to be adopted, the admissible tolerances, the criteria for selecting the samples to be tested and for verifying the conformity of the current production with the samples tested at the initial test. This document also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products. This document does not apply to fan-assisted radiators, fan-assisted convectors and trench convectors or to independent heating appliances.
- Standard64 pagesEnglish languagesale 15% off
This document specifies the requirements and test methods for the construction, safety, marking and rational use of energy.
This document is applicable to types B11AS, B11BS, B11CS, C11, C31 and C91 appliances (see 4.2) and those that:
— are closed-fronted;
— incorporate a natural draught burner;
— are connected directly to an open flue or to a device to evacuate the products of combustion (open-flued appliances, balanced-flued appliances);
— are wall mounted, free-standing or built-in;
— have a nominal heat input not exceeding 20 kW (based on the net calorific value).
This document is not applicable to:
— open fronted appliances as specified in EN 13278:2013;
— decorative fuel effect appliances as specified in EN 509:1999/A1:2003;
— catalytic combustion appliances;
— appliances in which the supply of combustion air and/or evacuation of products of combustion is achieved by mechanical means as specified in EN 1266:2002;
— ducted-air appliances;
— appliances installed by means of a closure plate (see 3.3.3.3).
Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.
- Standard82 pagesEnglish languagesale 10% offe-Library read for1 day
2021: CLC legacy converted by DCLab NISOSTS
- Amendment20 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to electric direct-acting room heaters. They may be portable, stationary, fixed, or built-in. It does not apply to: - thermal-storage room heaters (EN 60531); - heating appliances incorporated in the building structure; - central heating systems; - heaters connected to an air duct; - wall-paper, carpets or drapes incorporating flexible heating elements; - sauna stoves. This standard defines the main performance characteristics of direct-acting room heaters and specifies methods for measuring these characteristics, for the information of users. This standard does not specify values for performance characteristics. NOTE: - This standard does not deal with: - safety requirements (EN 60335-2-30); - acoustical noise of fan heaters (EN 60704-2-2).
- Amendment25 pagesEnglish languagesale 10% offe-Library read for1 day