Household electric direct-acting room heaters - Methods for measuring performance

This standard applies to electric direct-acting room heaters. They may be portable, stationary, fixed, or built-in. It does not apply to: - thermal-storage room heaters (EN 60531); - heating appliances incorporated in the building structure; - central heating systems; - heaters connected to an air duct; - wall-paper, carpets or drapes incorporating flexible heating elements; - sauna stoves. This standard defines the main performance characteristics of direct-acting room heaters and specifies methods for measuring these characteristics, for the information of users. This standard does not specify values for performance characteristics. NOTE: - This standard does not deal with: - safety requirements (EN 60335-2-30); - acoustical noise of fan heaters (EN 60704-2-2).

Elektrische Haushalt-Direktheizgeräte - Prüfverfahren zur Bestimmung der Gebrauchseigenschaft

Appareils électrodomestiques de chauffage des locaux à action directe - Méthodes de mesure de l'aptitude à la fonction

Gospodinjski sobni neposredni grelniki - Metode za merjenje funkcionalnosti - Dopolnilo A11

Ta standard se uporablja za sobne neposredne grelnike, ki so lahko prenosni, stacionarni, nepremični ali vgradni.
Ne uporablja se za:
– termoakumulacijske grelnike prostorov (IEC 531);
– grelne naprave, vgrajene v zgradbah;
– sisteme centralnega ogrevanja;
– grelnike, povezane s prezračevalnim kanalom;
– tapete, preproge ali draperije, ki vključujejo prilagodljive grelne elemente.
Ta standard določa glavne lastnosti delovanja sobnih neposrednih grelnikov in določa metode za merjenje teh lastnosti z namenom informiranja uporabnikov.
Ta standard ne določa vrednosti lastnosti delovanja.
OPOMBA: Ta standard ne obravnava:
– varnostnih zahtev (IEC 335-2-30);
– zvočnega hrupa ventilacijskih grelnikov (IEC 704-2-2).

General Information

Status
Published
Publication Date
22-Aug-2019
Withdrawal Date
16-Jun-2022
Current Stage
6060 - Document made available - Publishing
Start Date
23-Aug-2019
Due Date
28-Aug-2019
Completion Date
23-Aug-2019

Relations

Buy Standard

Amendment
EN 60675:1998/A11:2019
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2019
Gospodinjski sobni neposredni grelniki - Metode za merjenje funkcionalnosti -
Dopolnilo A11
Household electric direct-acting room heaters - Methods for measuring performance
Elektrische Haushalt-Direktheizgeräte - Prüfverfahren zur Bestimmung der
Gebrauchseigenschaft
Appareils électrodomestiques de chauffage des locaux à action directe - Méthodes de
mesure de l'aptitude à la fonction
Ta slovenski standard je istoveten z: EN 60675:1995/A11:2019
ICS:
97.100.10 Električni grelniki Electric heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60675:1995/A11

NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2019
ICS 97.100
English Version
Household electric direct-acting room heaters - Methods for
measuring performance
Appareils électrodomestiques de chauffage des locaux à Elektrische Haushalt-Direktheizgeräte - Prüfverfahren zur
action directe - Méthodes de mesure de l'aptitude à la Bestimmung der Gebrauchseigenschaft
fonction
This amendment A11 modifies the European Standard EN 60675:1995; it was approved by CENELEC on 2019-06-17. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60675:1995/A11:2019 E

Contents Page
European foreword . 3
1 Modification to Clause 1, "Scope" . 4
2 Modification to Clause 2, "Normative references" . 4
3 Modification to Clause 3, "Terms and Definitions" . 4
4 Modification to Clause 4, "Classification" . 9
5 Modification to clause 5, "List of measurements" . 11
6 Modification to clause 6, "General conditions for measurements" . 11
7 Modification to clause 7, "Dimensions, mass and means of connection to the
supply" . 12
8 Modification to clause 11, "Stability of room temperature" . 12
9 Modification to clause 12, "Set-back" . 13
10 Modification to clause 13, "Frost protection temperature" . 13
11 Modification to clause 14, "Inrush current" . 13
12 Modification to clause 16, "Measurement of the usable power" . 13
13 Addition of clause 17, "Requirements to comply with functions according to ecodesign
regulation" . 14
14 Modification of Annex A, “Climatic test room” . 18
15 Modification of Annex B, “Information provided at point of sales” . 20
16 Modification of Annex C, “Test report form” . 21
17 Additon of Annex ZZ . 24
18 Modification of Bibliography . 25

European foreword
This document (EN 60675:1995/A11:2019) has been prepared by CLC/TC 59X/WG 12 “Electric
room heating appliances”.
The following dates are fixed:

• latest date by which this document has to (dop) 2020-03-17
be implemented at national level by
publication of an identical national standard
or by endorsement
• latest date by which the national standards (dow) 2022-06-17
conflicting with this document have to be
withdrawn
This document has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association, and supports essential requirements of
EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of
this document.
The purpose of this amendment is to specify essential performance characteristics of direct
acting room heaters and to describe methods for measuring of these characteristics related to
EU Commission regulation (EU) No 2015/1188 and standardization request from the EU
Commission M/550.
1 Modification to Clause 1, "Scope"
Replace the whole clause with:
This standard applies to electric direct-acting room heaters. They may be portable, stationary,
fixed, or built-in.
It does not apply to:
– thermal-storage room heaters (EN 60531);
– heating appliances incorporated in the building structure;
– central heating systems;
– heaters connected to an air duct;
– wall-paper, carpets or drapes incorporating flexible heating elements;
– sauna stoves.
This standard defines the main performance characteristics of direct-acting room heaters and
specifies methods for measuring these characteristics, for the information of users.
This standard does not specify values for performance characteristics.
NOTE This standard does not deal with:
—safety requirements (EN 60335-2-30);
—acoustical noise of fan heaters (EN 60704-2-2).
2 Modification to Clause 2, "Normative references"
Replace the whole clause with:
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 60584-1:2013, Thermocouples - Part 1: EMF specifications and tolerances (IEC 60584-
1:2013)
3 Modification to Clause 3, "Terms and Definitions"
Replace the whole clause with:
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
local space heater (as defined in EU regulation (EU) No 2015/1188)
space heating device that emits heat by direct heat transfer or by direct heat transfer in
combination with heat transfer to a fluid, in order to reach and maintain a certain level of human
thermal comfort within an enclosed space in which the product is situated, possibly combined
with a heat output to other spaces and is equipped with one or more heat generators that convert
electricity or gaseous or liquid fuels directly into heat, through use of the Joule effect or
combustion of fuels respectively
3.2
direct-acting room heater
appliance which converts electrical energy into heat after a demand for heat has arisen in a
room and transfers this heat to the room directly
Note 1 to entry: In this standard, a direct-acting room heater is referred to as a heater.
3.3
panel heater
heater in which the temperature rise of all surfaces in contact with the circulating air does not
exceed 75 K in normal use
Note 1 to entry: Panel heaters may be oil filled.
Note 2 to entry: Panel heaters may be in column form.
Note 3 to entry: Panel heaters may include fluids and moving parts.
3.4
convector heater
heater in which the temperature rise of at least one non-visible part in contact with the
circulating air exceeds 75 K in normal use; the air is discharged through one or more outlets by
natural convection
Note 1 to entry: "Non-visible part" means that the part cannot be seen from a point situated 2 m in front
of the heater and 1,2 m above the floor when the heater is installed.
3.5
fan heater
heater in which the movement of air through it is accelerated by a fan
3.6
radiant heater
category 1
radiant heater
heater in which the temperature rise of at least one visible surface exceeds 75 K in normal use
Note 1 to entry: The visible surface may be seen through solid material which is transparent to heat
radiation. Materials such as quartz glass are considered to be transparent to heat radiation, while ordinary
glass is not.
category 2
electric radiant local space heater (as defined in (EU) No 2015/1188)
electric local space heater in which the heat emitting element is to be directed towards the place
of use so that its thermal radiation directly warms the subjects to be heated and which has a
temperature rise of the grill covering the heat emitting element of at least 130 K in normal use
and/or a temperature rise of 100 K for other surfaces
category 3
visibly glowing radiant heater
radiant heater in which the heating element is visible from the outside of the heater and has a
temperature of at least 650 °C in normal use
3.7
fixed local space heater
electric local space heater not intended to accumulate thermal energy and designed to be used
while fastened or secured in a specific location or wall mounted and not incorporated in the
building structure or building finishing
Note 1 to entry: Heaters with a heat retention of less than 20 % according to EN 60531 are still within
the scope of this standard.
Note 2 to entry: Heaters having an installed weight exceeding 18 kg which are not fixed but belong to
the category of stationary applainces are considered as fixed lacal space heaters.
3.8
portable local space heater
electric local space heater not intended to accumulate thermal energy and designed in such a
way that it can be placed in different locations without the use of tools
3.9
slave heater
electric local space heater which is not capable of autonomous operation and needs to receive
signals sent from an external master controller, not being part of the product but connected to
it by pilot wire, wireless, power line communication or an equivalent technique, in order to
regulate the emission of heat into the room in which the product is installed
3.10
room temperature control
mechanical or electronic device, sensitive to the room temperature and adjustable by the user
3.11
set-back function
function which allows the room temperature to be maintained at a lower value than the pre-set
(comfort) temperature without changing the setting of the room temperature control
3.12
frost protection means
means which allows the room temperature to be maintained at a value of 7 °C ± 3 °C
Note 1 to entry: The means may be a particular setting of the room temperature control.
3.13
rated power input
power input assigned to the heater by the manufacturer
3.14
energy ratio
ratio between the energy consumption during a representative period of operation and the
product of the rated power input and this period
3.15
average room temperature
arithmetic average of the maximum and minimum room temperatures for a setting of the room
temperature control
3.16
amplitude
difference between the maximum and the minimum room temperatures for a setting of the room
temperature control
3.17
drift
difference between the average room temperatures obtained at different energy ratios for a
setting of the room temperature control
3.18
nominal heat output
P
nom
heat output of a local space heater comprising both direct heat output and indirect heat output
(where applicable), when operating at the setting for the maximum heat output that can be
maintained over an extended period , as declared by the manufacturer, expressed in x,x kW

3.19
minimum heat output (indicative)
Pmin
heat output of a local space heater comprising both direct heat output and indirect heat output
(where applicable), when operating at setting of the lowest heat output, as declared by the
manufacturer, expressed in [x,x/N.A.] kW

3.20
maximum continuous heat output
P
max,c
declared heat output of an electric local space heater when operating at the setting for the
maximum heat output that can be maintained continuously over an extended period, as declared
by the manufacturer, expressed in x,x kW

3.21
electric power requirement in standby mode
elsb
electric power consumption of the product while in standby mode, expressed in x,xxx kW
Note 1 to entry: This is only applicable if the product has a “standby mode”. For electric local space
heaters without a standby mode the value is zero.
...