Lightning protection system components (LPSC) - Part 5: Requirements for earth electrode inspection housings and earth electrode seals

IEC 62561-5:2011 specifies the requirements and tests for - earth electrode inspection housings (earth pit), - earth electrode seals. Lightning protection system components (LPSC) may also be suitable for use in hazardous atmospheres. Regard should then be taken of the extra requirements necessary for the components to be installed in such conditions.

Blitzschutzsystembauteile (LPSC) - Teil 5: Anforderungen an Revisionskästen und Erderdurchführungen

Composants de système de protection contre la foudre (CSPF) - Partie 5: Exigences pour les regards de visite et les joints d'étanchéité des électrodes de terre

La CEI 62561-5:2011 spécifie les exigences et les essais pour - les regards de visite des électrodes de terre (regard de terre), - les joints d'étanchéité des électrodes de terre. Les composants de système de protection contre la foudre (CSPF) peuvent aussi être employés dans des atmosphères dangereuses. Il convient alors de prendre en compte les exigences supplémentaires nécessaires pour que les composants soient installés dans de telles conditions.

Elementi za zaščito pred strelo (LPC) - 5. del: Zahteve za merilne omarice ozemljil in tesnjenje izolacije pri ozemljilih

Ta 5. del IEC 62561 določa zahteve in preskuse za - merilne omarice ozemljil (ozemljitvena luknja), - tesnjenje izolacije pri ozemljilih. Elementi za zaščito pred strelo (LPSC) so lahko prav tako primerni za uporabo v nevarnih atmosferah. Treba je upoštevati dodatne zahteve, potrebne za vgradnjo komponent v takih okoliščinah.

General Information

Status
Withdrawn
Publication Date
04-Aug-2011
Withdrawal Date
27-Jul-2014
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Dec-2020
Completion Date
01-Dec-2020

Relations

Buy Standard

Standard
EN 62561-5:2011
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62561-5:2011
01-oktober-2011
1DGRPHãþD
SIST EN 50164-5:2009
(OHPHQWL]D]DãþLWRSUHGVWUHOR /3& GHO=DKWHYH]DPHULOQHRPDULFHR]HPOMLO
LQWHVQMHQMHL]RODFLMHSULR]HPOMLOLK
Lightning Protection System Components (LPSC) - Part 5: Requirements for earth
electrode inspection housings and earth electrode seals
Blitzschutzsystembauteile (LPSC) - Teil 5: Anforderungen an Revisionskästen und
Erderdurchführungen
Composants de système de protection contre la foudre (CSPF) - Partie 5: Exigences
pour les regards de visite et les joints d'étanchéité des électrodes de terre
Ta slovenski standard je istoveten z: EN 62561-5:2011
ICS:
91.120.40 =DãþLWDSUHGVWUHOR Lightning protection
SIST EN 62561-5:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62561-5:2011

---------------------- Page: 2 ----------------------

SIST EN 62561-5:2011

EUROPEAN STANDARD
EN 62561-5

NORME EUROPÉENNE
August 2011
EUROPÄISCHE NORM

ICS 29.020; 91.120.40 Supersedes EN 50164-5:2009


English version


Lightning protection system components (LPSC) -
Part 5: Requirements for earth electrode inspection housings and earth
electrode seals
(IEC 62561-5:2011, modified)


Composants de système de protection Blitzschutzsystembauteile (LPSC) -
contre la foudre (CSPF) - Teil 5: Anforderungen an Revisionskästen
Partie 5: Exigences pour les regards de und Erderdurchführungen
visite et les joints d'étanchéité des (IEC 62561-5:2011, modifiziert)
électrodes de terre
(CEI 62561-5:2011, modifiée)





This European Standard was approved by CENELEC on 2011-07-28. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62561-5:2011 E

---------------------- Page: 3 ----------------------

SIST EN 62561-5:2011
EN 62561-5:2011 - 2 -
Foreword
The text of document 81/391/FDIS, future edition 1 of IEC 62561-5, prepared by IEC TC 81, Lightning
protection, was submitted to the IEC-CENELEC parallel vote.
A draft amendment, prepared by the Technical Committee CENELEC TC 81X, Lightning protection, was
submitted to the formal vote.
The combined texts were approved by CENELEC as EN 62561-5:2011 on 2011-07-28.
This European Standard supersedes EN 50164-5:2009.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2012-07-28
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2014-07-28
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62561-5:2011 was approved by CENELEC as a European
Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
Whole document
Replace all references to IEC 62305 by references to EN 62305.
Replace all references to IEC 62561 by references to EN 62561.

2 Normative references
Replace the two references by the following
EN 62305 series, Protection against lightning (IEC 62305 series)
EN 62305-3, Protection against lightning – Part 3: Physical damage to structures and life hazard
(IEC 62305-3)

7 Structure and content of the test report
7.1 General
In the first sentence, replace “for laboratory test reports” by "for type test reports issued by the
laboratory”.

---------------------- Page: 4 ----------------------

SIST EN 62561-5:2011
- 3 - EN 62561-5:2011
Annex ZA
(normative)

Normative references to int
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.