EN 50177:1996
(Main)Automatic electrostatic spraying installations for flammable coating powder
Automatic electrostatic spraying installations for flammable coating powder
This European Standard specifies requirements for automatic electrostatic spraying installations which are used for spraying flammable coating powders which may form explosive atmospheres in the spraying area. In this connection distinction is made between spraying devices which due to their type of construction comply with requirements as laid down in EN 50050:1986 as applicable, and those for which other discharge energies and/or current limits are stipulated. It also specifies the constructional requirements for the safe operational conditions of the electrical installations including ventilation requirements. Additional requirements as to the construction of the spraying areas such as cabins, booths, etc. are dealt with in other standards
Ortsfeste elektrostatische Sprühanlagen für brennbare Beschichtungspulver
Installations automatiques de projection électrostatique de poudre de revêtement inflammable
Inštalacije za avtomatsko opremo za elektrostatično brizganje z gorljivim prahom za prevleke
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-1998
,QãWDODFLMH]DDYWRPDWVNRRSUHPR]DHOHNWURVWDWLþQREUL]JDQMH]JRUOMLYLPSUDKRP
]DSUHYOHNH
Automatic electrostatic spraying installations for flammable coating powder
Ortsfeste elektrostatische Sprühanlagen für brennbare Beschichtungspulver
Installations automatiques de projection électrostatique de poudre de revêtement
inflammable
Ta slovenski standard je istoveten z: EN 50177:1996
ICS:
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
87.100 Oprema za nanašanje Paint coating equipment
premazov
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
-------------------
...
This May Also Interest You
1.1 This European Standard specifies requirements for automatic electrostatic flock application equipment which is designed for applying ignitable flock which may form explosive atmospheres in the flock application area. In this context a distinction is made between flock application devices which due to their type of construction comply with the requirements as laid down in EN 50050-3, as applicable, and those for which higher discharge energies are stipulated. This European Standard also specifies the constructional requirements for a safe operation of the stationary equipment of flock application booths, including the electrical installations and the accessories. This European Standard deals with all significant hazards, hazardous situations and events relevant to flock application booths, when they are used as intended and under conditions which are foreseeable as malfunction by the manufacturer (see Clause 4). 1.2 This European Standard considers three types of electrostatic flock systems. For more details, see Table 1. 1.3 This European Standard deals with those hazards occurring during stationary automatic electrostatic flocking. Among these hazards are, above all, ignition hazards of the generated explosive atmosphere and hazard to persons. 1.4 The stationary equipment dealt with in this European Standard is considered to be equipment of group II, category 3D for the use in areas with potential explosion hazards of zone 22. 1.5 This European Standard is not applicable for - flock systems in which mixtures of solvent vapours in air occur with a concentration of > 20 % of the LEL, - flock systems operated with AC voltage, - the application system for liquid or pasty substances (e.g. adhesives, primer), - the cleaning of flock application booths, - the storage and handling of ignitable substances outside the coating plant.
- Standard54 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard51 pagesGerman languagesale 10% offe-Library read for×1 day
- Standard – translation55 pagesSlovenian languagesale 10% offe-Library read for×1 day
- 07-May-2015
- 12-Apr-2018
- 29.260.20
- 87.100
- 2006/42/EC
- 2014/34/EU
- 94/9/EC
- M/396
- CLC/TC 31
1.1 This European Standard specifies the requirements for hand-held or hand-operated electrostatic spraying equipment for ignitable flock within a temperature range from 5 °C to 40 °C to be used in explosive atmospheres generated by their own spray cloud. This European Standard deals with all electrical hazards significant for the electrostatic spraying of flock, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere. This European Standard specifies the design-related and test requirements for electrostatic spraying equipment of type A-F and type B-F according to Table 1 of EN 50223:2010. 1.2 Electrostatic applicators are considered to be equipment of group II, category 3D for use in potentially explosive areas of zone 22. All other parts of hand-held electrostatic spraying equipment are considered to be equipment of category 3D if they are installed or used in potentially explosive areas of zone 22. NOTE 1 Solvent vapours which could be evaporated by workpieces coated with adhesives do not lead to a zone 2 in the flocking area. 1.3 In addition to the requirements above, the requirements of EN 1953 applies with regard to all other significant hazards relevant for applicators (e.g. health hazards, inadequate ergonomics). 1.4 This European Standard does not apply to zone classification of the areas in and around spray booths [see EN 50223], zone classification of other areas with potentially explosive atmosphere [see EN 60079-10-2], selection, erection and application of other electrical and non-electrical equipment in areas with explosion hazard [see EN 60079 14 and EN 50223], cleaning of spraying areas, see instruction manual of the spraying equipment, fire prevention and protection, for instance fire hazards due to other sources [see EN 50223], explosion protection systems [see EN 50223], dust hazards [see EN 12981]. NOTE 2 Noise is not considered to be a significant hazard for hand-held spraying equipment for ignitable flock.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2013
- 13-Oct-2016
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
1.1 This European Standard specifies the requirements for hand-held or hand-operated electrostatic spraying equipment for ignitable liquid coating materials to be used in explosive atmospheres generated by their own spray cloud within a temperature range from 5 °C to 40 °C. This European Standard deals with all hazards significant for the electrostatic spraying of liquid coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere. This European Standard specifies the design-related and test requirements for electrostatic spraying equipment of type A-L according to Table 1 of EN 50176:2009. 1.2 With regard to explosion protection and prevention measures, this European Standard also applies to ionisators with high voltage corona charging. Ionisators in conformity with EN 50050-1 provide equipment category 2G. Parts of ionisators, which are intended to be used or installed in Zone 2, provide equipment category 3G in conformity with EN 50050-1, see Annex D. 1.3 Electrostatic applicators are considered to be equipment of group II, category 2G for use in potentially explosive areas of zone 1 or 2, which have been generated by the equipment itself. All other parts of hand-held electrostatic spraying equipment are considered to be equipment of category 3G if they are installed or used in potentially explosive areas of zone 2. 1.4 All other significant hazards relevant for applicators (e.g. ejection of fluids, mechanical strength, electrical hazards (apart from the electrostatic hazards), noise, explosion, contact with or inhalation of dangerous substances, ergonomics) are covered by EN 1953. 1.5 This European Standard also gives details regarding quality assurance systems for electrostatic spraying equipment, see Annex C. 1.6 Additional requirements may be applicable to equipment designed for use in food and pharmaceutical industry. 1.7 This European Standard does not apply to zone classification of the areas in and around spray booths [see EN 12215], zone classification of other areas with potentially explosive atmosphere [see EN 60079-10-1], selection, erection and application of other electrical and non-electrical equipment in areas with explosion hazard [see EN 60079 14 and EN 12215], cleaning of spraying areas, see instruction manual of the spraying equipment, fire prevention and protection, for instance fire hazards due to other sources [see EN 12215], requirements for machinery for the supply and recirculation of coating material under pressure [see EN 12621]. 1.8 When processing coating materials having specific electrical properties (conductivity, resistivity) the function of the hand-held spraying equipment to charge coating materials electrostatically may be affected as a result of a voltage drop at the charging electrode.
- Standard30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2013
- 13-Oct-2016
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
2012-06-18 - Publication editing allocated to cpalagi@cencenelec.eu
2021: CLC legacy converted by DCLab NISOSTS
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 16-Aug-2012
- 22-Jul-2015
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
1.1 This European Standard specifies the requirements for stationary electrostatic application equipment for ignitable coating powders to be used in explosive atmospheres generated by their own spray cloud. A distinction is made between spraying systems corresponding to EN 50050:2001 and spraying systems designed for higher discharge energies and/or currents. The charging of ignitable coating powder can be achieved by applying high voltage or triboelectrically. This European Standard also specifies the design-related requirements for a safe operation of the stationary equipment including its electrical installation. 1.2 This European Standard considers three types of electrostatic spraying systems; see 5.1 for more details. 1.3 This European Standard deals with all hazards significant for the electrostatic spraying of coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere, and the protection of persons from electric shocks. 1.4 This stationary equipment is classified as equipment of group II, category 2D or category 3D for use in potentially explosive areas of zone 21 or 22, respectively. NOTE For other safety aspects like – zone classification of the areas in and around spray booths, see EN 12981:2005, 5.6.2.3; – zone classification of other areas with explosive atmosphere, see EN 60079-10-2; – selection, erection and application of other electrical and non electrical equipment in areas with explosion hazard, see EN 60079 14 and EN 12981:2005, 5.6.2.4; – health protection (for instance, noise) see also EN 12981:2005, 5.4 and EN 14462; – cleaning of spraying areas, see instruction manual of the spraying equipment; – fire prevention and protection (for instance fire hazards due to other sources) see also EN 12981:2005, 5.6; – explosion protection system, see EN 12981:2005, 5.6.2.5; – dust hazards, see EN 12981:2005, 5.5. Design-related measures for reducing the generation of noise of the stationary equipment for electrostatic coating are given in EN ISO 11688 1. See also EN 14462.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Oct-2009
- 31-Aug-2012
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
1.1 This European Standard specifies the requirements for stationary electrostatic application equipment for ignitable liquid coating materials and for hard to ignite liquid coating materials to be used in explosive atmospheres generated by their own spray cloud. A distinction is made between spraying systems corresponding to EN 50050 and spraying systems designed for higher discharge energies and/or currents. This European Standard also specifies the design-related requirements for a safe operation of the stationary equipment including its electrical installation. 1.2 This European Standard considers four types of electrostatic spraying systems; see 5.1 for more details. 1.3 This European Standard deals with all hazards significant for the electrostatic spraying of coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere, and the protection of persons from electric shocks. 1.4 This stationary equipment is classified as equipment of group II, category 2G or category 3G for use in potentially explosive areas of zone 1 or 2, respectively. NOTE For other safety aspects like – zone classification of the areas in and around spray booths, see EN 12215:2004, 5.7.2.3; – zone classification of other areas with explosive atmosphere, see EN 60079-10-1; – selection, installation and application of other electrical and non electrical equipment in areas with explosion hazard, see EN 60079-14 and EN 12215:2004, 5.7.2.5; – health protection (for instance, noise), see also EN 12215:2004, 5.5 and EN 14462; – cleaning of spraying areas, see instruction manual of the spraying equipment; – fire prevention and protection (for instance fire hazards due to other sources) see also EN 12215:2004, 5.7.1. Design-related measures for reducing the generation of noise of the stationary equipment for electrostatic coating are given in EN ISO 11688 1. See also EN 14462.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Oct-2009
- 31-Aug-2012
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
1.1 This document specifies the electrical requirements for the design of automatic electrostatic application systems for liquid coating materials which can be ignited in an atomised state, used within a temperature range from 5 °C to 40 °C. This document considers automatic electrostatic application systems for processing ignitable liquid coating materials, where the conductivity of the complete system is limited up to 50 nS/cm. Together with additional measures like e.g. potential separation systems, these requirements can also be applied to ignitable liquid coating materials, where the conductivity of the complete system is limited up to 2 000 μS/cm. Ignition hazards related to the generated explosive atmosphere and the protection of persons against electric shock are considered. 1.2 This document specifies — requirements for an interface to machinery according to EN 16985:2018, — additional requirements for machinery covered by EN 1953:— and EN 12621:— . 1.3 This document also specifies requirements for a safe operation of electrostatic application systems, including the electrical installation. The requirements consider both the processing of coating materials and the cleaning and purge processes. 1.4 This document applies to three types of spraying systems; see 5.1.1. Spraying systems are classified as equipment of group II, category 2G (for intended use in zone 1 or zone 2) or category 3G (for intended use in zone 2). Only electrostatic spraying systems operating with a d.c. sinusoidal ripple of not more than 10 % of the r.m.s. value are considered. 1.5 For electrostatic application systems used in food and pharmaceutical industry, additional requirements may apply. 1.6 This document does not apply to — potential separation systems; — selection, installation and application of other electrical and non-electrical equipment in areas with explosion hazard, see EN 60079-14:2014 and EN 16985:2018; — quality assurance systems for electrostatic spraying equipment (see EN ISO/IEC 80079-34:2020, Annex ZB.11).
- Draft50 pagesEnglish languagesale 10% offe-Library read for×1 day
1.1 This European Standard specifies the requirements for hand-held or hand-operated electrostatic spraying equipment for non-ignitable liquid coating materials which — do not generate an explosive atmosphere inside the spraying area; — are used to process materials with a conductivity of less than 2 000 µS/cm; — operate with direct current having a sinusoidal ripple of not more than 10 % of the rms value. This European Standard deals with all electrical hazards significant for the electrostatic spraying of non-ignitable liquid coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. This European Standard specifies the design-related and test requirements for electrostatic spraying equipment of type A-NL according to Table 1 of EN 50348:2010. 1.2 With regard to all other significant hazards relevant for applicators (e.g. ejection of fluids, mechanical strength, electrical - apart from electrostatic - hazards, noise, contact with or inhalation of dangerous substances, ergonomics) the requirements of EN 1953 apply. 1.3 This European Standard also gives details regarding quality assurance systems for electrostatic spraying equipment, see Annex D. 1.4 For electrostatic spraying equipment used in food and pharmaceutical industry, additional requirements may apply. 1.5 This document is not applicable to — electrostatic hand-held spraying equipment for non-ignitable coating materials which are manufactured before the date of its publication as EN, — cleaning of spraying areas, see instruction manual of the spraying booth, — fire prevention and protection [for instance fire hazards due to other sources; see EN 12215, EN 12981], — requirements for machinery for the supply and recirculation of coating material under pressure [see EN 12621]. The requirements of EN 12621 apply for specific requirements for machinery for the supply and recirculation of coating materials under pressure.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Jul-2018
- 26-Jul-2021
- 87.100
- 2006/42/EC
- M/396
- CLC/TC 204
1.1 This European Standard specifies requirements for automatic electrostatic flock application equipment which is designed for applying ignitable flock which may form explosive atmospheres in the flock application area. In this context a distinction is made between flock application devices which due to their type of construction comply with the requirements as laid down in EN 50050-3, as applicable, and those for which higher discharge energies are stipulated. This European Standard also specifies the constructional requirements for a safe operation of the stationary equipment of flock application booths, including the electrical installations and the accessories. This European Standard deals with all significant hazards, hazardous situations and events relevant to flock application booths, when they are used as intended and under conditions which are foreseeable as malfunction by the manufacturer (see Clause 4). 1.2 This European Standard considers three types of electrostatic flock systems. For more details, see Table 1. 1.3 This European Standard deals with those hazards occurring during stationary automatic electrostatic flocking. Among these hazards are, above all, ignition hazards of the generated explosive atmosphere and hazard to persons. 1.4 The stationary equipment dealt with in this European Standard is considered to be equipment of group II, category 3D for the use in areas with potential explosion hazards of zone 22. 1.5 This European Standard is not applicable for - flock systems in which mixtures of solvent vapours in air occur with a concentration of > 20 % of the LEL, - flock systems operated with AC voltage, - the application system for liquid or pasty substances (e.g. adhesives, primer), - the cleaning of flock application booths, - the storage and handling of ignitable substances outside the coating plant.
- Standard54 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard51 pagesGerman languagesale 10% offe-Library read for×1 day
- Standard – translation55 pagesSlovenian languagesale 10% offe-Library read for×1 day
- 07-May-2015
- 12-Apr-2018
- 29.260.20
- 87.100
- 2006/42/EC
- 2014/34/EU
- 94/9/EC
- M/396
- CLC/TC 31
1.1 This European Standard specifies the requirements for hand-held or hand-operated electrostatic spraying equipment for ignitable flock within a temperature range from 5 °C to 40 °C to be used in explosive atmospheres generated by their own spray cloud. This European Standard deals with all electrical hazards significant for the electrostatic spraying of flock, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere. This European Standard specifies the design-related and test requirements for electrostatic spraying equipment of type A-F and type B-F according to Table 1 of EN 50223:2010. 1.2 Electrostatic applicators are considered to be equipment of group II, category 3D for use in potentially explosive areas of zone 22. All other parts of hand-held electrostatic spraying equipment are considered to be equipment of category 3D if they are installed or used in potentially explosive areas of zone 22. NOTE 1 Solvent vapours which could be evaporated by workpieces coated with adhesives do not lead to a zone 2 in the flocking area. 1.3 In addition to the requirements above, the requirements of EN 1953 applies with regard to all other significant hazards relevant for applicators (e.g. health hazards, inadequate ergonomics). 1.4 This European Standard does not apply to zone classification of the areas in and around spray booths [see EN 50223], zone classification of other areas with potentially explosive atmosphere [see EN 60079-10-2], selection, erection and application of other electrical and non-electrical equipment in areas with explosion hazard [see EN 60079 14 and EN 50223], cleaning of spraying areas, see instruction manual of the spraying equipment, fire prevention and protection, for instance fire hazards due to other sources [see EN 50223], explosion protection systems [see EN 50223], dust hazards [see EN 12981]. NOTE 2 Noise is not considered to be a significant hazard for hand-held spraying equipment for ignitable flock.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2013
- 13-Oct-2016
- 87.100
- 2014/34/EU
- 94/9/EC
- CLC/TC 31
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.