Alarm systems - Intrusion systems - Part 5-1: Interconnections - Requirements for wired Interconnection for I&HAS equipments located in supervised premises

This document applies to interconnections between intrusion and hold-up alarm system components using specific or non-specific wired interconnections (e.g. between SPT and CIE). The interconnected components are located within the supervised premises, or mounted on the outside of the supervised premises (e.g. external warning devices). This document does not apply to interconnections between components located within the same enclosure, or to interconnections between parts of an I&HAS component if covered by the relevant product standard. This document does not define the physical requirements of the interconnection media. This document is expected to be used in conjunction with the other parts of the EN 50131 series that define the functional requirements of the equipment regardless of the interconnection technique used. Where monitoring of the functionality of the interconnections is undertaken by an interconnected component, this is defined in the relevant product standard in the EN 50131 series. If a component standard indicates that an interconnection will be monitored, then this document determines the monitored conditions applicable to the interconnection. NOTE 1 For example, if there is no requirement in a detector standard to monitor a remote indication of detection input, this document does not apply to that particular interconnection. Requirements for the monitoring of the functionality of power connections between I&HAS components are defined in the relevant product standard and are not included within this document. This document defines the terms used in the field of intrusion and hold-up alarm equipment using such interconnections and includes the requirements relevant to the equipment interfaces. Wired interconnection media can include metallic single stranded insulated cable, metallic multi-stranded insulated cable, and fibre optic cable. These cables can comprise single or multiple cores. NOTE 2 Interconnections using RF techniques (i.e. wire free interconnections) are dealt with by EN 50131 5 3.

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 5-1: Verbindungen - Anforderungen an leitungsgebundene Verbindungen für EMA/ÜMA Einrichtungen in überwachten Objekten

Systèmes d'alarme - Systèmes d'alarme contre l'intrusion - Partie 5-1 : Interconnexions - Exigences pour l'interconnexion filaire des équipements contre l'intrusion et les hold-up situés dans des locaux sous surveillance

Alarmni sistemi - Sistemi za javljanje vloma - 5-1. del: Povezave - Zahteve za žične povezave za I&HAS opremo nameščeno v nadzorovanih prostorih

General Information

Status
Published
Publication Date
25-Feb-2021
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
26-Feb-2021
Due Date
30-Aug-2021
Completion Date
26-Feb-2021

Buy Standard

Technical specification
TS CLC/TS 50131-5-1:2021
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CLC/TS 50131-5-1:2021
01-april-2021
Alarmni sistemi - Sistemi za javljanje vloma - 5-1. del: Povezave - Zahteve za žične
povezave za I&HAS opremo nameščeno v nadzorovanih prostorih
Alarm systems - Intrusion systems - Part 5-1: Interconnections - Requirements for wired
Interconnection for I&HAS equipments located in supervised premises
Ta slovenski standard je istoveten z: CLC/TS 50131-5-1:2021
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST-TS CLC/TS 50131-5-1:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST-TS CLC/TS 50131-5-1:2021

---------------------- Page: 2 ----------------------
SIST-TS CLC/TS 50131-5-1:2021


TECHNICAL SPECIFICATION CLC/TS 50131-5-1

SPÉCIFICATION TECHNIQUE

TECHNISCHE SPEZIFIKATION
February 2021
ICS 13.320

English Version
Alarm systems - Intrusion systems - Part 5-1: Interconnections -
Requirements for wired Interconnection for I&HAS equipments
located in supervised premises
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
5-1: Verbindungen - Anforderungen an leitungsgebundene 5-1: Verbindungen - Anforderungen an leitungsgebundene
Verbindungen für EMA/ÜMA Einrichtungen in überwachten Verbindungen für EMA/ÜMA Einrichtungen in überwachten
Objekten Objekten
This Technical Specification was approved by CENELEC on 2021-01-11.

CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly
at national level in an appropriate form. It is permissible to keep conflicting national standards in force.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. CLC/TS 50131-5-1:2021 E

---------------------- Page: 3 ----------------------
SIST-TS CLC/TS 50131-5-1:2021
CLC/TS 50131-5-1:2021 (E)
Contents
European foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 7
3 Terms, definitions and abbreviations . 7
3.1 Terms and definitions . 7
3.2 Abbreviations . 8
4 Requirements . 8
4.1 General . 8
4.1.1 Introduction . 8
4.1.2 Interconnection Integrity . 9
4.1.3 Availability . 10
4.1.4 Verification of communications . 11
4.1.5 Message/signal Integrity . 12
4.2 Response to monitori
...