Safety of power transformers, power supply units and similar products - Part 2-9: Particular requirements for transformers for class III handlamps for tungsten filament lamps

This Part 2-9 of EN 61558 applies to stationary or portable single-phase air-cooled (natural or forced) associated safety isolating transformers for class III handlamps for tungsten filament lamps, having a rated supply voltage not exceeding 1 000 V a.c., a rated frequency not exceeding 500 Hz and a rated output not exceeding 10 kVA. It has the status of a group safety publication in accordance with IEC Guide 104

Sicherheit von Transformatoren, Netzgeräten und dergleichen - Teil 2-9: Besondere Anforderungen an Transformatoren für Handleuchten der Schutzklasse III für Wolframdrahtlampen

Sécurité des transformateurs, blocs d'alimentation et produits analogues - Partie 2-9: Règles particulières pour les transformateurs pour baladeuses de class III pour lampes à filament de tungstène

Cette Partie 2-9 de la EN 61558 s'applique aux transformateurs de sécurité pour baladeuses de classe III pour lampes à filament de tungstène, associés, monophasés, à refroidissement par air (circulation naturelle ou forcée), fixes ou mobiles, ayant une tension primaire assignée ne dépassant pas 1 000 V courant alternatif, une fréquence assignée ne dépassant pas 500 Hz, et une puissance assignée ne dépassant pas 10 kVA. Elle a le statut de publication groupée de sécurité conformément au guide CEI 104.

Safety of power transformers, power supply units and similar products - Part 2-9: Particular requirements for transformers for class III handlamps for tungsten filament lamps

General Information

Status
Withdrawn
Publication Date
06-Jan-2003
Withdrawal Date
30-Nov-2005
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
02-Jan-2014
Completion Date
02-Jan-2014

Relations

Buy Standard

Standard
EN 61558-2-9:2003
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SIST EN 61558-2-9:2003SLOVENSKIseptember 2003
STANDARDSafety of power transformers, power supply units and similar products - Part 2-9: Particular requirements for transformers for class III handlamps for tungsten filament lamps©
Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 61558-2-9:2003(en)ICS29.180







EUROPEAN STANDARD
EN 61558-2-9 NORME EUROPÉENNE EUROPÄISCHE NORM
January 2003 CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61558-2-9:2003 E
ICS 29.180 Supersedes EN 60742:1995
English version
Safety of power transformers, power supply units and similar products Part 2-9: Particular requirements for transformers
for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2002)
Sécurité des transformateurs, blocs d'alimentation et produits analogues Partie 2-9: Règles particulières
pour les transformateurs pour baladeuses de class III pour lampes à filament
de tungstène (CEI 61558-2-9:2002)
Sicherheit von Transformatoren, Netzgeräten und dergleichen Teil 2-9: Besondere Anforderungen
an Transformatoren für Handleuchten der Schutzklasse III für Wolframdrahtlampen (IEC 61558-2-9:2002)
This European Standard was approved by CENELEC on 2002-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.



EN 61558-2-9:2003 - 2 - Foreword The text of document 96/184/FDIS, future edition 1 of IEC 61558-2-9, prepared by IEC TC 96, Small power transformers, reactors, supply units and similar products, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61558-2-9 on 2002-12-01.
This Part 2-9 of EN 61558 replaces section 4 of chapter III of EN 60742:1995.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2003-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2005-12-01
This Part 2-9 is intended to be used in conjunction with EN 61558-1:1997. This Part 2-9 supplements or modifies the corresponding clauses in EN 61558-1, so as to convert that publication into the European Standard: Particular requirements for transformers for class III handlamps for tungsten filament lamps. When a particular subclause of Part 1 is not mentioned in this Part 2-9, that subclause applies as far as is reasonable. Where this Part 2-9 states “addition”, “modification” or “replacement”, the relevant text of Part 1 is to be adapted accordingly. In this standard, the following print types are used: - requirements proper: in roman type; - test specifications: in italic type; - explanatory matter: in smaller roman type. In the text of this standard the words in bold are defined in clause 3. Subclauses which are additional to those in Part 1 are numbered starting from 101. __________ Endorsement notice The text of the International Standard IEC 61558-2-9:2002 was approved by CENELEC as a European Standard without any modification. __________



NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD61558-2-9Première éditionFirst edition2002-07Sécurité des transformateurs, blocsd'alimentation et produits analogues –Partie 2-9:Règles particulières pour les transformateurspour baladeuses de classe III pour lampesà filament de tungstèneSafety of power transformers, power supplyunits and similar products –Part 2-9:Particular requirements for transformersfor class III handlamps for tungstenfilament lampsPour prix, voir catalogue en vigueurFor price, see current catalogue IEC 2002
Droits de reproduction réservés

Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite niutilisée sous quelque forme que ce soit et par aucun procédé,él
...

Questions, Comments and Discussion