Voltage surge protective devices - Part 11: Surge protective devices connected to AC low-voltage power systems - Requirements and test methods

Überspannungsschutzgeräte für Niederspannung – Teil 11: Überspannungsschutzgeräte für den Einsatz in Niederspannungs-Wechselstromnetzen – Anforderungen und Prüfverfahren

Partie 11: Parafoudres connectés aux réseaux basse tension en courant alternatif - Exigences et méthodes d’essai

Nizkonapetostne naprave za zaščito pred prenapetostnimi udari - 11. del: Naprave za zaščito pred prenapetostnimi udari za nizkonapetostne AC napajalne sisteme - Zahteve in preskusne metode (fragment 1)

General Information

Status
Not Published
Publication Date
25-May-2025
Current Stage
4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
Start Date
26-Jan-2024
Due Date
26-Jan-2024
Completion Date
26-Jan-2024

Relations

Buy Standard

Draft
prEN IEC 61643-11:2024 - BARVE
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2024
Nizkonapetostne naprave za zaščito pred prenapetostnimi udari - 11. del: Naprave
za zaščito pred prenapetostnimi udari za nizkonapetostne AC napajalne sisteme -
Zahteve in preskusne metode (fragment 1)
Fragment 1: Low-voltage surge protective devices - Part 11: Surge protective devices
connected to AC low-voltage power systems - Requirements and test methods
Partie 11: Parafoudres connectés aux systèmes basse tension - Exigences et méthodes
d'essai
Ta slovenski standard je istoveten z: prEN IEC 61643-11:2023 {frag1}
ICS:
29.120.50 Varovalke in druga Fuses and other overcurrent
nadtokovna zaščita protection devices
29.240.10 Transformatorske postaje. Substations. Surge arresters
Prenapetostni odvodniki
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

37A/403/CDV
COMMITTEE DRAFT FOR VOTE (CDV)

PROJECT NUMBER:
IEC 61643-11/FRAG1 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-11-03 2024-01-26
SUPERSEDES DOCUMENTS:
37A/368/CD, 37A/393/CC
IEC SC 37A : LOW-VOLTAGE SURGE PROTECTIVE DEVICES
SECRETARIAT: SECRETARY:
United States of America Mr Casey Granata
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

SC 37B,TC 64,TC 81,TC 82,TC 109
Other TC/SCs are requested to indicate their interest, if any,
in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they
are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries”
clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for
submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Fragment 1: Low-voltage surge protective devices - Part 11: Surge protective devices connected to AC
low-voltage power systems - Requirements and test methods

PROPOSED STABILITY DATE: 2026
NOTE FROM TC/SC OFFICERS:
This document must be read in conjuction with 37A/401/CDV for IEC 61643-01.
This fragment 1 is the core document. Fragment 2 contains an option for an additional Annex from CLC for
Additional requirements for portable SPDs classified as pluggable equipment type A.
Annex E from 37A/368/CD was decided to be shifted to future IEC TR 61643-03, which should be distributed as
a DTR in parallel to this CDV.

electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

IEC CDV 61643-11/F1/Ed2 © IEC 2023 – 2 – 37A/403/CDV
1 CONTENTS
4 FOREWORD . 4
5 INTRODUCTION . 6
6 1 Scope . 7
7 2 Normative references . 7
8 3 Terms, definitions and abbreviated terms . 7
9 4 Classification . 8
10 4.13 End of life mode of the SPD-assembly . 8
11 4.100 Power system . 8
12 4.100.1 AC between 47 Hz and 63 Hz . 8
13 4.100.2 AC other than the range of 47 Hz to 63 Hz . 8
14 5 Void . 8
15 6 Marking and other product information . 8
16 6.2 List of items . 8
17 6.2.100 Markings which are required on the body, or permanently attached to
18 the body, of the SPD: . 8
19 6.2.101 Information to be provided by the manufacturer: . 8
20 6.2.102 Information which shall be provided by the manufacturer for type
21 testing, as applicable: . 8
22 7 Service conditions . 9
23 7.100 Frequency . 9
24 8 Requirements . 9
25 8.3 Electrical requirements . 9
26 8.3.9 Behaviour under temporary overvoltages . 9
27 8.5 Environmental and material requirements . 9
28 8.5.5 Ageing behaviour under damp heat . 9
29 9 Tests . 9
30 9.1 General . 9
31 9.1.1 General testing procedures . 9
32 9.3 Electrical tests . 14
33 9.3.3 Protective conductor current I . 14
PE
34 9.3.5 Operating duty test . 14
35 9.3.6 Disconnectors, SC-means and safety performance of overstressed
36 SPDs . 14
37 9.3.9 Behaviour under temporary overvoltages (TOVs) . 17
38 9.5 Environmental and material tests . 21
39 9.5.5 Life test under damp heat . 21
40 Annex A (normative) Application of annexes from IEC 61643-01 . 22
41 Annex B (normative)  Test voltages for SPDs - U . 23
test
42 Annex C (normative)  TOV Ratings . 29
43 C.1 TOV ratings based on IEC 60364-4-44, chapter 442 . 29
44 C.2 Other TOV ratings for specific distribution systems or countries . 30
45 C.2.1 North American systems . 30
46 C.2.2 Japanese systems . 30
47 Annex D (normative) Reduced test procedures . 32

IEC CDV 61643-11/F1/Ed2 © IEC 2023 – 3 – 37A/403/CDV
49 FIGURES
50 Figure 1 – Test circuit for the dedicated overstress test . 16
51 Figure 2 – Timing diagram for the dedicated overstress test . 17
52 Figure 3 – Example of a test circuit to perform the test under TOVs caused by faults in
53 the low voltage system . 18
54 Figure 4 – Timing diagram for the test under TOVs caused by faults in the low voltage
55 system . 19
56 Figure 5 – Example of a test setup for testing SPDs for use in TT systems under TOVs
57 caused by faults in high (medium) voltage systems . 20
58 Figure 6 – Timing diagram for use in testing SPDs under TOVs caused by faults in the
59 high (medium) voltage system using the circuit of Figure 5 . 21
61 TABLES
62 Table 1 – Type test requirements for SPDs . 11
63 Table 2 – Prospective short-circuit current and power factor . 15
64 Table A.1 - Application of annexes from IEC 61643-01 . 22
65 Table B.1 –Test voltage values . 24
66 Table B.2 – Test voltage values for Japanese systems . 28
67 Table C.1 – TOV test values for systems complying with IEC 60364 series . 30
68 Table C.2 – TOV test parameters for North American systems . 30
69 Table C.3 – TOV test parameters for Japanese systems . 31
70 Table D.1 – Reduced test procedure for SPDs complying with IEC 61643-11:2011 . 33
IEC CDV 61643-11/F1/Ed2 © IEC 2023 – 4 – 37A/403/CDV
73 INTERNATIONAL ELECTROTECHNICAL COMMISSION
74 ____________
76 LOW-VOLTAGE SURGE PROTECTIVE DEVICES –
78 Part 11: Surge protective devices connected
79 to AC low-voltage power systems –
80 Requirements and test methods
84 FOREWORD
85 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
86 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
87 international co-operation on all questions concerning standardization in the electrical and electronic fields. To
88 this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
89 Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
90 Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
91 in the subject dealt with may participate in this preparatory work. International, governmental and non -
92 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
93 with the International Organization for Standardization (ISO) in accordance with conditions determined by
94 agreement between the two organizations.
95 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
96 consensus of opinion on the relevant subjects since each technical committee has representation from all
97 interested IEC National Committees.
98 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
99 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
100 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
101 misinterpretation by any end user.
102 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
103 transparently to the maximum extent possible in their national and regional publications. Any divergence
104 between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
105 the latter.
106 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
107 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
108 services carried out by independent certification bodies.
109 6) All users should ensure that they have the latest edition of this publication.
110 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
111 members of its technical committees and IEC National Committees for any personal injury, property damage or
112 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
113 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
114 Publications.
115 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
116 indispensable for the correct application of this publication.
117 9) A
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.