Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin sleeving, flame retarded, shrink ratios 2:1, 3:1, 4:1

This part of IEC 60684 gives the requirements for six types of general purpose, heat shrinkable dual wall polyolefin sleevings, flame retarded with nominal shrink ratios of 2:1, 3:1 or 4:1 and available in low and high temperature adhesive inner walls.

Isolierschläuche - Teil 3: Anforderungen für einzelne Schlauchtypen - Blatt 248: Polyolefin-Wärmeschrumpfschläuche mit Innenbeschichtung, Standardtyp, flammwidrig, Schrumpfverhältnisse 2:1, 3:1, 4:1

Gaines isolantes souples - Partie 3: Spécifications pour types particuliers de gaines - Feuille 248: Utilisation générale, thermorétractable, gaine à double paroi en polyoléfine, retardée à la flamme, rapport de rétreint 2:1, 3:1, 4:1

La CEI 60684-3-248:2007 définit les exigences relatives à six types de gaines à usage général, thermorétractables, en polyoléfine, à double paroi, retardées à la flamme avec des rapports de rétreint de 2:1, 3:1 et 4:1 et disponibles en parois internes adhésives à basse et haute températures.

Gibke izolacijske cevi – 3. del: Specifikacije za posamezne vrste cevi – 248. list: Splošnonamenske, toplotno skrčljive cevi z dvojno polilefinsko steno, ognjevarne, s skrčnimi razmerji 2:1, 3:1, 4:1 (IEC 60684-3-248:2007)

General Information

Status
Published
Publication Date
25-Apr-2007
Withdrawal Date
31-Mar-2010
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
26-Apr-2007
Completion Date
26-Apr-2007

Buy Standard

Standard
EN 60684-3-248:2007
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2007
*LENHL]RODFLMVNHFHYL±GHO6SHFLILNDFLMH]DSRVDPH]QHYUVWHFHYL±OLVW
6SORãQRQDPHQVNHWRSORWQRVNUþOMLYHFHYL]GYRMQRSROLOHILQVNRVWHQRRJQMHYDUQH
VVNUþQLPLUD]PHUML ,(&
Flexible insulating sleeving -- Part 3: Specifications for individual types of sleeving --
Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin sleeving, flame
retarded, shrink ratios 2:1, 3:1, 4:1 (IEC 60684-3-248:2007)
Isolierschläuche - Teil 3: Anforderungen für einzelne Schlauchtypen - Blatt 248:
Polyolefin-Wärmeschrumpfschläuche mit Innenbeschichtung, Standardtyp, flammwidrig,
Schrumpfverhältnisse 2:1, 3:1, 4:1 (IEC 60684-3-248:2007)
Gaines isolantes souples -- Partie 3: Spécifications pour types particuliers de gaines --
Feuille 248: Utilisation générale, thermorétractable, gaine a double paroi en polyoléfine,
retardée a la flamme, rapport de rétreint 2:1, 3:1, 4:1 (IEC 60684-3-248:2007)
Ta slovenski standard je istoveten z: EN 60684-3-248:2007
ICS:
29.035.20 3ODVWLþQLLQJXPHQLL]RODFLMVNL Plastics and rubber insulating
PDWHULDOL materials
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60684-3-248
NORME EUROPÉENNE
April 2007
EUROPÄISCHE NORM
ICS 29.035.20
English version
Flexible insulating sleeving -
Part 3: Specifications for individual types of sleeving -
Sheet 248: General purpose, heat-shrinkable,
dual wall polyolefin sleeving, flame retarded,
shrink ratios 2:1, 3:1, 4:1
(IEC 60684-3-248:2007)
Gaines isolantes souples -  Isolierschläuche -
Partie 3: Spécifications Teil 3: Anforderungen
pour types particuliers de gaines - für einzelne Schlauchtypen -
Feuille 248: Utilisation générale, Blatt 248: Polyolefin-
thermorétractable, gaine à double paroi Wärmeschrumpfschläuche
en polyoléfine, retardée à la flamme, mit Innenbeschichtung,
rapport de rétreint 2:1, 3:1, 4:1 Standardtyp, flammwidrig,
(CEI 60684-3-248:2007) Schrumpfverhältnisse 2:1, 3:1, 4:1
(IEC 60684-3-248:2007)
This European Standard was approved by CENELEC on 2007-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60684-3-248:2007 E

Foreword
The text of document 15/359/FDIS, future edition 1 of IEC 60684-3-248, prepared by IEC TC 15, Solid
electrical insulating materials, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60684-3-248 on 2007-04-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2008-01-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-04-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60684-3-248:2007 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 60684-3-248:2007
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 60684-1 2003 Flexible insulating sleeving - EN 60684-1 2003
Part 1: Definitions and general requirements

IEC 60684-2 1997 Flexible insulating sleeving - EN 60684-2 1997
A1 2003 Part 2: Methods of test A1 2003
A2 2005 A2 2005
IEC 60757 1983 Code for designation of colours HD 457 S1 1985

ISO 1817 2005 Rubber, vulcanized - Determination of the - -
effect of liquids
INTERNATIONAL IEC
STANDARD 60684-3-248
First edition
2007-02
Flexible insulating sleeving –
Part 3:
Specifications for individual types of sleeving –
Sheet 248: General purpose, heat-shrinkable, dual
wall polyolefin sleeving, flame retarded, shrink
ratios 2:1, 3:1, 4:1
© IEC 2007 ⎯ Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale M
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

– 2 – 60684-3-248 © IEC:2007(E)
CONTENTS
FOREWORD.3
INTRODUCTION.5

1 Scope.6
2 Normative references.6
3 Designation .7
4 Conditions of test.7
5 Requirements .7
6 Sleeving conformance.7
7 Elevated temperature performance test.8

Figure 1 – Test assembly for elevated temperature performance .8

Table 1 – Size of stepped mandrel for elevated temperature performance test.8
Table 2 – Dimensional requirements – Type AL and AH.9
Table 3 – Dimensional requirements – Type BL and BH.9
Table 4 – Dimensional requirements – Type CL and CH .10
Table 5 – Property requirements .11
Table 6 – Requirements for breakdown voltage .12
Table 7 – Resistance to selected fluids.13
Table 8 – Additional property requirements.13

60684-3-248 © IEC:2007(E) – 3 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –
Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin
sleeving, flame retarded, shrink ratios 2:1, 3:1, 4:1

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60684-3-248 has been prepared by IEC technical committee 15:
Solid electrical insulating materials.
The text of this standard is based on the following documents:
FDIS Report on voting
15/359/FDIS 15/372/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

– 4 – 60684-3-248 © IEC:2007(E)
A list of all parts of the IEC 60684 series, published under the general title Flexible insulating
sleeving, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until the

maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

60684-3-248 © IEC:2007(E) – 5 –

INTRODUCTION
This international Standard is one of a series which deals with flexible insulating sleeving for
electrical purposes.
The series consists of three parts:
Part 1: Definitions and general requirements ( IEC 60684-1)
Part 2: Methods of test ( IEC 60684-2 )
Part 3: Specifications for individual types of sleeving ( IEC 60684-3 )
This standard comprises one of the sheets of Part 3 as follows:
Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin sleeving, flame retarded,
shrink ratios 2:1, 3:1, 4:1
– 6 – 60684-3-248 © IEC:2007(E)
FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –
Sheet 248: General purpose, heat-shrinkable, dual wall polyolefin
sleeving, flame retarded, shrink ratios 2:1, 3:1, 4:1

1 Scope
This part of IEC 60684 gives the requirements for six types of general purpose, heat shrinkable
dual wall polyolefin sleevings, flame retarded with nominal shrink ratios of 2:1, 3:1 or 4:1 and
available in low and high temperature adhesive inner walls.
The low temperature adhesive sleeving has been found suitable for temperatures up to 105 °C
and the high temperature adhesive sleeving has been found suitable for temperatures up to
125 °C.
− Type AL:
2:1 shrink ratio, internal diameter up to 51 mm
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.