EN 50131-6:1997
(Main)Alarm systems - Intrusion systems - Part 6: Power supplies
Alarm systems - Intrusion systems - Part 6: Power supplies
This Standard specifies requirements, testing procedures and performance criteria for PS for use in intrusion detection and hold-up-alarm systems in buildings. This standard covers mandatory functions which shall be provided on all PS and optional functions with requirements which may be provided. Other functions associated with intrusion detection and hold-up-alarm not specified in this standard may be provided. Such functions shall not effect the requirements of any mandatory or optional functions
Alarmanlagen - Einbruchmeldeanlagen - Teil 6: Energieversorgungen
Systèmes d'alarme - Systèmes d'alarme intrusion - Partie 6: Alimentation
Alarm systems - Intrusion systems - Part 6: Power supplies
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-1999
Alarm systems - Intrusion systems - Part 6: Power supplies
Alarm systems - Intrusion systems -- Part 6: Power supplies
Alarmanlagen - Einbruchmeldeanlagen -- Teil 6: Energieversorgungen
Systèmes d'alarme - Systèmes d'alarme intrusion -- Partie 6: Alimentation
Ta slovenski standard je istoveten z: EN 50131-6:1997
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This document is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130 5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to detect the broad spectrum infrared radiation emitted by an intruder, to analyse the resulting signals and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. The grade-dependent requirements of this document apply and it is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.
- Standard53 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE. This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard. The requirements correspond to each of the four security grades given in the European Standard EN 50131 1, Alarm Systems – Intrusion and Hold-Up Systems - Part 1: System requirements. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations. This standard covers: a) mandatory functions which will be provided on all PS; and b) optional functions which may be provided. This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions and reduced functional test for EMC susceptibility testing as required by EN 50130 4. Other functions associated with I&HAS not specified in this standard may be provided. Such functions will not affect the requirements of any mandatory or optional functions.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is for combined passive infrared and microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to detect the broad spectrum infrared radiation emitted by an intruder, to emit microwave signals and analyse the signals that are returned and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. For a combined detector where both detection technologies need to be in their activated state in order to generate an alarm condition, the grade-dependent requirements of this document apply. For combined detectors which can be configured or operated such that each detection technology can generate an alarm condition independently, the grade-dependant requirements as defined in EN 50131 2 2 and EN 50131-2-3 apply, when configured accordingly. Otherwise, it is the responsibility of the manufacturer to clearly state that the detector does not comply to this document and not to EN 50131-2-2 and EN 50131 2-3 when put into such a configuration. It is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.
- Standard54 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements for Intrusion and Hold-up Alarm Systems installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to the components of an I&HAS installed in a building which are normally mounted on the external structure of a building e.g. ancillary control equipment or warning devices. The standard does not include requirements for exterior I&HAS. This standard specifies performance requirements for installed I&HAS but does not include requirements for design, planning, installation, operation or maintenance. These requirements also apply to I&HAS sharing means of detection, triggering, interconnection, control, communication and power supplies with other applications. The functioning of an I&HAS shall not be adversely influenced by other applications. Requirements are specified for I&HAS components where the relevant environment is classified. This classification describes the environment in which an I&HAS component may be expected to function as designed. When the requirements of the four environmental classes are inadequate, due to the extreme conditions experienced in certain geographic locations, special national conditions are given in Annex A. General environmental requirements for I&HAS components are described in Clause 7. The requirements of this European Standard also apply to IAS and HAS when these systems are installed independently. When an I&HAS does not include functions relating to the detection of intruders, the requirements relating to intrusion detection do not apply. When an I&HAS does not include functions relating to hold-up, the requirements relating to hold-up do not apply. NOTE Unless otherwise stated the abbreviation I&HAS is intended to also mean IAS and HAS.
- Amendment11 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE. This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard. The requirements correspond to each of the four security grades given in the European Standard EN 50131 1, Alarm Systems - Intrusion and Hold-Up Systems - Part 1: System requirements. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations. This standard covers: a) mandatory functions which will be provided on all PS; and b) optional functions which may be provided. This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions and reduced functional test for EMC susceptibility testing as required by EN 50130 4. Other functions associated with I&HAS not specified in this standard may be provided. Such functions will not affect the requirements of any mandatory or optional functions.
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
Harmonise system requirements with requirements for system components specified in standard published since EN 50131-1:2006 was published.
- Amendment14 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard applies to intrusion alarm equipment using radio frequency (RF) links and located on protected premises. It does not cover long-range radio transmissions. This European Standard defines the terms used in the field of intrusion alarm equipment using radio frequency links as well as the requirements relevant to the equipment.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for×1 day
This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
- Technical specification37 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements for Intrusion and Hold-up Alarm Systems installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to the components of an I&HAS installed in a building which are normally mounted on the external structure of a building e.g. ancillary control equipment or warning devices. The standard does not include requirements for exterior I&HAS. This standard specifies performance requirements for installed I&HAS but does not include requirements for design, planning, installation, operation or maintenance. These requirements also apply to I&HAS sharing means of detection, triggering, interconnection, control, communication and power supplies with other applications. The functioning of an I&HAS shall not be adversely influenced by other applications. Requirements are specified for I&HAS components where the relevant environment is classified. This classification describes the environment in which an I&HAS component may be expected to function as designed. When the requirements of the four environmental classes are inadequate, due to the extreme conditions experienced in certain geographic locations, special national conditions are given in Annex A. General environmental requirements for I&HAS components are described in Clause 7. The requirements of this European Standard also apply to IAS and HAS when these systems are installed independently. When an I&HAS does not include functions relating to the detection of intruders, the requirements relating to intrusion detection do not apply. When an I&HAS does not include functions relating to hold-up, the requirements relating to hold-up do not apply. NOTE Unless otherwise stated the abbreviation I&HAS is intended to also mean IAS and HAS.
- Addendum19 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.