Corrigendum 1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)

Corrigendum 1 - Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes fondamentales d'essais et de mesures - Partie 2-1: Essais - Vibrations (sinusoïdales)

General Information

Status
Published
Publication Date
13-Jan-2010
Current Stage
DELPUB - Deleted Publication
Completion Date
23-Jan-2023
Ref Project

Relations

Buy Standard

Standard
IEC 61300-2-1:2009/COR1:2010 - Corrigendum 1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) Released:1/14/2010
English and French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 61300-2-1 CEI 61300-2-1
(3rd edition – 2009) (3ème édition – 2009)

Fibre optic interconnecting devices and passive
Dispositifs d’interconnexion et composants
components – Basic test and measurement

passifs à fibres optiques – Méthodes
procedures –
fondamentales d’essais et de mesures –
Part 2-1: Tests – Vibration (sinusoidal)

Partie 2-1 : Essais – Vibrations (sinusoïdales)

C O R R I G E N D U M  1
Page 8 Page 16
Replace the existing Tables 1 and 2 with the Remplacer les Tableaux 1 et 2 existants par les
following new Tables 1 and 2: nouveaux Tableaux 1 et 2 suivants:

Table 1 – Connectors and passive components
Category Parameter Value
Categories C, U and E Frequency range 10 Hz– 55 Hz
Sweep rate 1 oct/min
Number of sweeps 15/axis
Amplitude 0,75 mm
Category O Frequency range 10 Hz – 55 Hz
Sweep rate 1 oct/min for passive
components
45 Hz/min for connectors
Duration 2 h/axis
Amplitude 1,52 mm for passive
components
0,75 mm for connectors
Table 2 – Fibre management systems and closures

Category Parameter Val
...