Corrigendum 2 - Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 1: General requirements

Corrigendum 2 - Outils électroportatifs à moteur, outils portables et machines pour jardins et pelouses - Sécurité - Partie 1: Règles générales

General Information

Status
Published
Publication Date
13-Oct-2015
Current Stage
PPUB - Publication issued
Start Date
18-Sep-2015
Completion Date
14-Oct-2015
Ref Project

Relations

Buy Standard

Standard
IEC 62841-1:2014/COR2:2015 - Corrigendum 2 - Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 1: General requirements Released:14. 10. 2015
English and French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 62841-1:2014/COR2:2015 – 1 –
 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________

IEC 62841-1 IEC 62841-1
Edition 1.0  2014-03 Édition 1.0  2014-03


ELECTRIC MOTOR-OPERATED HAND- OUTILS ÉLECTROPORTATIFS À MOTEUR,
HELD TOOLS, TRANSPORTABLE TOOLS OUTILS PORTABLES ET MACHINES POUR
AND LAWN AND GARDEN MACHINERY JARDINS ET PELOUSES – SÉCURITÉ –
– SAFETY –
Partie 1: Règles générales
Part 1: General requirements


CO RRI G E NDUM 2



Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.

5 General conditions for the tests
Replace 5.19 with the following:
5.19 All electrical measurements shall be made with a maximum measurement error of 5 %.
Instruments for measuring voltage shall have an input resistance of at least 1 MΩ with a
maximum parallel capacitance of 150 pF.




Rationale for this corrigendum:
The maximum parallel capacitance for instruments for measuring voltage was increased from
25 pF to 150 pF. A 25 pF maximum parallel capacitance is not typical for voltage measuring
equipment, and would require highly specialized and expensive
...