Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Shielded screening attenuation, test method for measuring of the screening attenuation as up to and above 3 GHz

determines the screening attenuation as of metallic communication cable screens. Due to the concentric outer tube, measurements are independent of irregularities on the circumference and outer electromagnetic field. A wide dynamic and frequency range can be applied to test even super-screened cables with normal instrumentation from low frequencies up to the limit of defined transversal waves in the outer circuit at approximately 4 GHz.

General Information

Status
Published
Publication Date
08-May-2006
Current Stage
DELPUB - Deleted Publication
Completion Date
29-Apr-2015
Ref Project

Relations

Buy Standard

Standard
IEC 62153-4-4:2006 - Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Shielded screening attenuation, test method for measuring of the screening attenuation as up to and above 3 GHz Released:5/9/2006 Isbn:2831886333
English language
16 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL IEC
STANDARD 62153-4-4
First edition
2006-05
Metallic communication cable test methods –
Part 4-4:
Electromagnetic compatibility (EMC) –
Shielded screening attenuation, test method
for measuring of the screening attenuation a
s
up to and above 3 GHz
Reference number
Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in the
60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.
Consolidated editions
The IEC is now publishing consolidated versions of its publications. For example,
edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the
base publication incorporating amendment 1 and the base publication incorporating
amendments 1 and 2.
Further information on IEC publications
The technical content of IEC publications is kept under constant review by the IEC,
thus ensuring that the content reflects current technology. Information relating to
this publication, including its validity, is available in the IEC Catalogue of
publications (see below) in addition to new editions, amendments and corrigenda.
Information on the subjects under consideration and work in progress undertaken
by the technical committee which has prepared this publication, as well as the list
of publications issued, is also available from the following:
• IEC Web Site (www.iec.ch)
• Catalogue of IEC publications
The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to
search by a variety of criteria including text searches, technical committees
and date of publication. On-line information is also available on recently issued
publications, withdrawn and replaced publications, as well as corrigenda.
• IEC Just Published
This summary of recently issued publications (www.iec.ch/online_news/ justpub)
is also available by email. Please contact the Customer Service Centre (see
below) for further information.
• Customer Service Centre
If you have any questions regarding this publication or need further assistance,
please contact the Customer Service Centre:

Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD 62153-4-4
First edition
2006-05
Metallic communication cable test methods –
Part 4-4:
Electromagnetic compatibility (EMC) –
Shielded screening attenuation, test method
for measuring of the screening attenuation a
s
up to and above 3 GHz
 IEC 2006  Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale P
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

– 2 – 62153-4-4  IEC:2006(E)
CONTENTS
FOREWORD.3

Scope.5
2 Normative references.5
3 Symbols and theoretical background .5
3.1 Electrical symbols.5
3.2 Theoretical background .6
3.3 Screening attenuation .6
3.4 Relationship between length and the surface transfer impedance Z .7
T
4 Principles of the measuring method .10
5 Measurement.11
5.1 Equipment .11
5.2 Cable under test .11
5.3 Procedure.14
5.4 Expression of results .14
6 Requirement.15

Figure 1 – Relationship of U /U on a log (f) scale for a single braided cable .8
2 1
Figure 2 – Relationship of U /U on a linear (f) scale and screening attenuation a on a
2 1 s
linear (f) scale for a single braided cable .9
Figure 3 – Measured screening attenuation a formed by the maximum envelope curve
s
to the measured coupling voltage ratio U /U of a single braided cable .9
2 1
Figure 4 – Triaxial measuring set-up .10
Figure 5 – Triaxial measuring set-up connected to the network analyser .10
Figure 6 – Preparation of test sample (symmetrical and multi-conductor cables) .11
Figure 7 – Impedance matching for Z <50 Ω .13
Figure 8 – Impedance matching for Z >50 Ω .13
62153-4-4  IEC:2006(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
METALLIC COMMUNICATION CABLE TEST METHODS –

Part 4-4: Electromagnetic compatibility (EMC) –
Shielded screening attenuation, test method for measuring of
the screening attenuation a up to and above 3 GHz
s
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62153-4-4 has been prepared by subcommittee 46A: Coaxial
cables, of IEC technical committee 46: Cables, wires, waveguides, r.f. connectors, r.f. and
microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46A/799/FDIS 46A/816/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

– 4 – 62153-4-4  IEC:2006(E)
IEC 62153 consists of the following parts under the general title Metallic communication cable
test methods:
Part 1-1: Electrical – Measurement of the pulse/step return loss in the frequency domain
using the Inverse Discrete Fourier Transformation (IDFT)
Part 1-2: Reflection measurement correction
Part 4-0: Electromagnetic Compatibility (EMC) – Relationship between Surface transfer
impedance and Screening attenuation, recommended limits
Part 4-1: Electromagnetic Compatibility (EMC) – Introduction to electromagnetic (EMC)
screening measurements
Part 4-2: Electromagnetic compatibility (EMC) – Screening and coupling attenuation –
Injection clamp method
Part 4-3: Electromagnetic Compatibility (EMC) – Surface transfer impedance – Triaxial
method
Part 4-4: Electromagnetic Compatibility (EMC) – Shielded screening attenuation, test method
for measuring of the screening attenuation "as " up to and above 3 GHz
Part 4-5: Electromagnetic Compatibility (EMC) – Coupling or screening attenuation –
absorbing clamp method
Part 4-6: Electromagnetic Compatibility (EMC) – Surface transfer impedance – line injection
method
Part 4-7: Electromagnetic Compatibility (EMC) – Shielded screening attenuation, test method
for measuring the Transfer impedance ZT, the screening attenuation as and the
coupling attenuation ac of RF-Connectors up to and above 3 GHz; Tube in Tube
method
Part 4-8: Electromagnetic Compatibility (EMC) – Capacitive Coupling Admittance
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

___________
Under consideration.
62153-4-4  IEC:2006(E) – 5 –
METALLIC COMMUNICATION CABLE TEST METHODS –

Part 4-4: Electromagnetic compatibility (EMC) –
Shielded screening attenuation, test method for measuring of
the screening attenuation a up to and above 3 GHz
s
1 Scope
This part of IEC 62153 determines the screening attenuation a of metallic communication
s
cable screens. Due to the concentric outer tube, measurements are independent of
irregularities on the circumference and outer electromagnetic field.
A wide dynamic and frequency range can be applied to test even super-screened cables with
normal instrumentation from low frequencies up to the limit of defined transversal waves in the
outer circuit at approximately 4 GHz.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 61917:1998, Cables, cable assemblies and connectors – Introduction to electromagnetic
(EMC) screening measurements
3 Symbols and theoretical background
3.1 Electrical symbols
Z characteristic impedance of the primary circuit (cable under test)
characteristic impedance of the secondary circuit
Z
Z normalized value of the characteristic impedance of the environment
S
of the cable under test (150 Ω outer circuit impedance Z )
R input impedance of the receiver
Z transfer impedance of the cable under test in Ω/m
T
Z= Z× Z × jω × C capacitive coupling impedance of the cable under test in Ω/m
F 1 2 T
f frequency in Hz
C through capacitance of the outer conductor per unit length in F/m
T
relative dielectric permittivity of the cable under test
ε
r1
relative dielectric permittivity of the secondary circuit
ε
r2
ε normalized value of the relative dielectric permittivity of the
r2,n
environment of the cable
effective coupling length
l
___________
This is under revision and will be replaced by IEC 62153-4-1.

– 6 – 62153-4-4  IEC:2006(E)
vacuum wavelength
λ
o
c vacuum velocity
o
a screening attenuation which is comparable to the results of the

s
absorbing clamp method
a normalized screening attenuation (Z = 150 Ω and |Δv/v | = 10 %)
sn S 1
P feeding power of the primary circuit
P measured power received on the input impedance R of the receiver in
the secondary circuit
P radiated power in the
...