IEC 61347-2-2:2011
(Main)Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV.
This publication is to be read in conjunction with IEC 61347-1:2007.
Appareillages de lampes - Partie 2-2: Exigences particulières pour les convertisseurs abaisseurs électroniques alimentés en courant continu ou alternatif pour lampes à incandescence
La CEI 61347-2-2:2011 spécifie les exigences de sécurité particulières applicables aux convertisseurs abaisseurs électroniques pour emploi sur alimentations en courant continu jusqu'à 250 V ou en courant alternatif jusqu'à 1 000 V à 50 Hz ou 60 Hz et de tension de sortie assignée 50 V efficace d'une fréquence différente de celle de la tension d'alimentation, ou 120 V en courant continu lissé entre conducteurs et entre un conducteur et la terre, associés à des lampes tungstène-halogène comme celles spécifiées dans la CEI 60357, et avec d'autres lampes à incandescence. Cette deuxième édition de la CEI 61347-2-2 remplace la première édition (2000), l'Amendement 1 (2005) et l'Amendement 2 (2006). La principale modification de cette deuxième édition concerne le changement de l'équivalent TBTS en TBTS.
Cette publication doit être lue conjointement avec la CEI 61347-1:2007.
General Information
Relations
Standards Content (Sample)
IEC 61347-2-2 ®
Edition 2.0 2011-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Lamp controlgear –
Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down
convertors for filament lamps
Appareillages de lampes –
Partie 2-2: Exigences particulières pour les convertisseurs abaisseurs
électroniques alimentés en courant continu ou alternatif pour lampes à
incandescence
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61347-2-2 ®
Edition 2.0 2011-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Lamp controlgear –
Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down
convertors for filament lamps
Appareillages de lampes –
Partie 2-2: Exigences particulières pour les convertisseurs abaisseurs
électroniques alimentés en courant continu ou alternatif pour lampes à
incandescence
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX N
ICS 29.140.99 ISBN 978-2-88912-813-6
– 2 – 61347-2-2 © IEC:2011
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references. 6
3 Terms and definitions . 7
4 General requirements . 7
5 General notes on tests . 8
6 Classification . 8
7 Marking . 8
7.1 Mandatory marking . 8
7.2 Information to be provided if applicable . 8
8 Protection against accidental contact with live parts . 8
9 Terminals . 9
10 Provisions for protective earthing . 9
11 Moisture resistance and insulation . 9
12 Electric strength . 9
13 Thermal endurance test for windings of ballasts . 9
14 Fault conditions . 9
15 Transformer heating . 9
15.1 General . 9
15.2 Normal operation . 9
15.3 Abnormal operation . 10
16 Construction . 10
17 Creepage distances and clearances . 10
18 Screws, current-carrying parts and connections . 10
19 Resistance to heat, fire and tracking . 10
20 Resistance to corrosion . 10
Bibliography . 13
61347-2-2 © IEC:2011 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LAMP CONTROLGEAR –
Part 2-2: Particular requirements for d.c. or a.c. supplied
electronic step-down convertors for filament lamps
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-2 has been prepared by subcommittee 34C: Auxiliaries for
lamps, of IEC technical committee 34: Lamps and related equipment.
This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005)
and Amendment 2 (2006). The major modification for this second edition is the changeover
from SELV equivalent to SELV.
This standard shall be used in conjunction with the second edition of IEC 61347-1 (2007) and
its Amendment 1 (2010) and 2 (to be published).
– 4 – 61347-2-2 © IEC:2011
The text of this standard is based on the following documents:
FDIS Report on voting
34C/994/FDIS 34C/1001/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This part 2 supplements or modifies the clauses in IEC 61347-1, so as to convert that
publication into the IEC Standard: Particular requirements for d.c. or a.c. supplied electronic
step-down convertors for filament lamps.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
A list of all parts of the IEC 61347 series, under the general title: Lamp control gear can be
found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61347-2-2 © IEC:2011 – 5 –
INTRODUCTION
This second edition of IEC 61347-2-2 is published in conjunction with IEC 61347-1. The
formatting into separately published parts provides for ease of future amendments and
revisions. Additional requirements will be added as and when a need for them is recognized.
This standard, and the other parts which make up IEC 61347-2, in referring to any of the
clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in
which the tests are to be performed; they also include additional requirements, as necessary.
All parts which make up IEC 61347-2 are self-contained and, therefore, do not include
references to each other.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard
by the phrase "The requirements of clause n of IEC 61347-1 apply", this phrase is interpreted
as meaning that all requirements of the clause in question of part 1 apply, except any which are
clearly inapplicable to the specific type of lamp control gear covered by this particular part of
IEC 61347-2.
– 6 – 61347-2-2 © IEC:2011
LAMP CONTROLGEAR –
Part 2-2: Particular requirements for d.c. or a.c. supplied
electronic step-down convertors for filament lamps
1 Scope
This part of IEC 61347 specifies particular safety requirements for electronic step-down
convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or
60 Hz and with rated output voltage ≤ 50 V r.m.s. at a frequency deviating from the supply
frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth,
associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps.
NOTE The limit of 50 V rated output voltage is in accordance with band I of IEC 60449.
Particular requirements for electronic step-down convertors with means of protection against
overheating are given in Annex C.
Particular additional requirements for convertors providing safety extra low voltage (hereinafter
SELV), are given in Annex I.
Performance requirements are covered by IEC 61047.
Plug-in convertors, being part of the luminaire, are covered as for built-in convertors by the
additional requirements of the luminaire standard.
2 Normative references
For the purpose of this part of IEC 61347, the normative references given in Clause 2 of
IEC 61347-1 which are mentioned in this standard apply, together with the following normative
references:
IEC 60357, Tungsten halogen lamps (non vehicle) – Performance specifications
IEC 61047, DC or a.c. supplied electronic step-down convertors for filament lamps –
Performance requirements
IEC 61347-1:2007, Lamp controlgear – Part 1: General and safety requirements
Amendment 1 (2010)
IEC 61558-2-1, Safety of power transformers, power supplies, reactors and similar products –
Part 2-1: Particular requirements and tests for separating transformers and power supplies
incorporating separating transformers for general applications
IEC 61558-2-6, Safety of transformers, reactors, power supply units and similar products for
supply voltages up to 1 100 V – Part 2-6: Particular requirements and tests for safety isolating
transformers and power supply units incorporating safety isolating transformers
IEC 61558-2-13, Safety of transformers, reactors, power supply units and similar products for
supply voltages up to 1 100 V – Part 2-13: Particular requirements and tests for auto
transformers and power supply units incorporating auto transformers
61347-2-2 © IEC:2011 – 7 –
IEC 61558-2-16, Safety of transformers, reactors, power supply units and similar products for
voltages up to 1 100 V – Part 2-16: Particular requirements and tests for switch mode power
supply units and transformers for switch mode power supply units
3 Terms and definitions
For the purposes of this part of IEC 61347, the terms and definitions given in Clause 3 of
IEC 61347-1 apply, together with the following:
3.1
electronic step-down convertor
unit inserted between the supply and one or more tungsten-halogen or other filament lamps
which serves to supply the lamp(s) with its (their) rated voltage, generally at high frequency
The unit may consist of one or more separate components and may include means for
dimming, correcting the power factor and suppressing radio interference.
3.2
d.c. or a.c. supplied convertor
convertor that includes stabilizing elements for operating one or more filament lamps, generally
at high frequency
3.3
SELV convertor
convertor providing a SELV output isolated from the supply mains by means such as a safety
isolating transformer, as specified in IEC 61558-2-6 and IEC 61558-2-16
3.4
independent convertor
convertor designed to supply unspecified appliances and intended to be used without any
additional enclosure which provides protection against electric shock
3.5
plug-in convertor
convertor incorporated in an enclosure provided with an integral plug as the means of
connection of the electrical supply
3.6
rated output voltage
output voltage, at rated supply voltage, rated frequency and at unity power factor, assigned to
the convertor
3.7
half-resistance effect
effect which can occur at the end of lamp life due to filament deformation or crystallization
effects resulting in a partial short-circuit of the lamp filament, which can cause overloading of
the convertor
4 General requirements
The requirements of Clause 4 of IEC 61347-1 apply, together with the following additional
requirement:
Convertors providing SELV shall comply with the requirements of Annex I. This includes
insulation resistance, electric strength, creepage distances and clearances between primary
and secondary circuits.
– 8 – 61347-2-2 © IEC:2011
Other types of convertors shall comply with the requirements of:
– IEC 61558-2-13 and IEC 61558-2-16, for auto-wound convertors,
– IEC 61558-2-1 and IEC 61558-2-16, for separating convertors.
5 General notes on tests
The requirements of Clause 5 of IEC 61347-1 apply, with the following additional requirement:
5.8 Number of specimens
The following number of specimens shall be submitted for testing:
– one unit for the tests of Clauses 6 to 12 and 15 to 20;
– one unit for the tests of Clause 14 (additional units or components, where necessary, may
be required in consultation with the manufacturer).
Unless otherwise declared by the manufacturer, the tests are carried out with the length of the
output wire or cable either 20 cm or 200 cm, choosing the most unfavourable condition. It is
possible to use two twisted wires or cable H03VV-. The cross section of the conductors shall
be chosen according to the rated wattage and the current density shall not exceed 5 A/mm in
normal use.
6 Classification
Convertors are classified according to the method of installation given in Clause 6 of
IEC 61347-1 and according to:
– Protection against electric shock
• auto wound (autotransformer) convertors,
• separating convertors,
• SELV convertors.
7 Marking
7.1 Mandatory marking
Convertors, other than integral convertors, shall be clearly and durably marked, in accordance
with the requirements of 7.2 of IEC 61347-1, with the following mandatory markings:
– items a), b), c), d), e), f), k), l), m), s) and t) of 7.1 of IEC 61347-1, together with
– rated output voltage.
7.2 Information to be provided if applicable
In addition to the above mandatory markings, the following information, if applicable, shall be
given either on the convertor, or be made available in the manufacturer’s catalogue or similar:
– items h), i), j) and s) of 7.1 of IEC 61347-1 together with
– mention whether the convertor has mains-connected windings,
– a declaration of the allowed length of the output wire or cable, if it is not between 20 cm and
200 cm.
8 Protection against accidental contact with live parts
The requirements of Clause 10 of IEC 61347-1 apply.
61347-2-2 © IEC:2011 – 9 –
9 Terminals
The requirements of Clause 8 of IEC 61347-1 apply.
10 Provisions for protective earthing
The requirements of Clause 9 of IEC 61347-1 apply.
11 Moisture resistance and insulation
The requirements of Clause 11 of IEC 61347-1 apply.
12 Electric strength
The requirements of Clause 12 of IEC 61347-1 apply.
13 Thermal endurance test for windings of ballasts
The requirements of Clause 13 of IEC 61347-1 are not applicable.
14 Fault conditions
The requirements of Clause 14 of IEC 61347-1 apply, together with the following additional
requirements:
In the case of convertors provided with the marking , the requirements specified in Annex C
shall be fulfilled.
In addition, the output voltage of the convertor, when operated under fault conditions, shall not
exceed 115 % of the rated output voltage.
15 Transformer heating
15.1 General
SELV and separating convertors shall be tested according to Clause L.6 and L.7 of
IEC 61347-1, where the requirements for control gear providing SELV are valid also for
separating convertors.
15.2 Normal operation
The requirements of Clause L.6 of IEC 61347-1 apply, together with the following additional
requirements:
The test shall be carried out with the length of the output cable of both, 20 cm and 200 cm,
unless otherwise declared by the manufacturer.
For built-in and integrated convertors, tests shall be made under conditions such that the
convertor is brought to t , as reached under normal operation at rated supply voltage.
c
The load in normal operating conditions should be made by normal lamps.
– 10 – 61347-2-2 © IEC:2011
15.3 Abnormal operation
The requirements of Clause L.7 of IEC 61347-1 apply, together with the following additional
requirements:
The test shall be carried out with the length of the output cable of both, 20 cm and 200 cm,
unless otherwise declared by the manufacturer.
In addition, the following test at any voltage between 90 % and 110 % of the rated supply
voltage, shall be performed with the control gear operating according to the manufacturer’s
instructions (including heat sinks, if specified) for 1 h.
The output voltage of the convertor, when operated under fault conditions, shall not exceed
115 % of the rated output voltage.
Double the number of lamps of the type for which the convertor is designed are connected in
parallel to the output terminals.
During and at the end of the tests specified above, the convertor shall show no defect impairing
safety, nor shall any smoke or flammable gases be produced.
After the test(s), when the convertor has returned to ambient temperature, the insulation
resistance measured at approximately 500 V d.c. shall not be less than 1 MΩ.
To check whether gases liberated from the convertor are flammable or not, a test with a high
frequency spark generator is made.
The temperatures on components in non-totally enclosed convertors shall not exceed their
rated values.
16 Construction
The requirements of Clause 15 of IEC 61347-1 apply.
17 Creepage distances and clearances
Unless otherwise specified in Clause 14, the requirements of Clause 16 of IEC 61347-1 apply.
18 Screws, current-carrying parts and connections
The requirements of Clause 17 of IEC 61347-1 apply.
19 Resistance to heat, fire and tracking
The requirements of Clause 18 of IEC 61347-1 apply.
20 Resistance to corrosion
The requirements of Clause 19 of IEC 61347-1 apply.
61347-2-2 © IEC:2011 – 11 –
Annex A
(normative)
Test to establish whether a conductive part
is a live part which may cause an electric shock
The requirements of Annex A of IEC 61347-1 apply.
Annex B
(normative)
Particular requirements for thermally protected
lamp controlgear
The requirements of Annex B of IEC 61347-1 are not applicable.
Annex C
(normative)
Particular requirements for electronic lamp controlgear
with means of protection against overheating
The requirements of Annex C of IEC 61347-1 app
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...