Interpretation sheet 1 - Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications

Feuille d'interprétation 1 - Lampes à LED à deux culots conçues pour remplacer des lampes à fluorescence linéaires - Spécifications de sécurité

General Information

Status
Published
Publication Date
17-Jun-2018
Current Stage
PPUB - Publication issued
Start Date
06-Jul-2018
Completion Date
18-Jun-2018
Ref Project

Relations

Buy Standard

Standard
IEC 62776:2014/ISH1:2018 - Interpretation sheet 1 - Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications Released:6/18/2018
English and French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 62776
Edition 1.0  2014-12
DOUBLE-CAPPED LED LAMPS DESIGNED
TO RETROFIT LINEAR FLUORESCENT LAMPS –
SAFETY SPECIFICATIONS
INTERPRETATION SHEET 1
This interpretation sheet has been prepared by subcommittee 34A: Lamps, of IEC technical
committee 34: Lamps and related equipment.
The text of this interpretation sheet is based on the following documents:
FDIS Report on voting
34A/2081/FDIS 34A/2090/RVD
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.

___________
Interpretation of Clause 7 of IEC 62776:2014
The statement in the first paragraph of Clause 7 that “there shall not be any electrical
continuity between the two ends of the lamp during the insertion” is in contradiction with the
compliance requirements that follow. In the physical world, establishing the complete lack of
any electrical continuity between the two ends is not possible since all materials may be
characterized by their inherent conductivity however small it may be.
The compliance requirements described in the fourth paragraph of Clause 7 shall take
precedence.