Corrigendum 1 - Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"

Corrigendum 1 - Atmosphères explosives - Partie 18: Protection du matériel par encapsulage "m"

General Information

Status
Published
Publication Date
24-Jul-2018
Current Stage
PPUB - Publication issued
Start Date
19-Sep-2018
Completion Date
25-Jul-2018
Ref Project

Relations

Buy Standard

Standard
IEC 60079-18:2014/COR1:2018 - Corrigendum 1 - Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" Released:7/25/2018
English and French language
1 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


 IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60079-18 IEC 60079-18
Edition 4.0  2014-12 Édition 4.0  2014-12

EXPLOSIVE ATMOSPHERES – ATMOSPHÈRES EXPLOSIVES –

Part 18: Equipment protection Partie 18: Protection du matériel
by encapsulation "m" par encapsulage "m"

CO RRI G ENDU M 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.

8.2.5.1 Test procedure
Replace the final paragraph of Subclause 8.2.5.1 by the following new text:

The tensile force applied shall be derived in the following way:
 Measure the diameter of the cable (mm), multiply this value by 20
 Measure the mass (kg) of the ‘m’ apparatus and multiply this value by 50
 Take the lower numerical value of these calculations and apply it (in Newtons) as tensile
force for the cable pull test.
This value may be reduced to 25 % of the required value in the case of fixed installations. The
minimum tensil
...