IEC 61156-8
(First edition – 2009)
Multicore and symmetrical pair/quad cables for digital communications –
Part 8: Symmetrical pair/quad cables with transmission characteristics up to 1 200 MHz – Work
area wiring – Sectional specification
CORRIGENDUM 1
6 Characteristics and requirements
6.3.11 Return loss (RL)
Replace the existing Table 4 of 6.3.11 by the following Table 4 and delete the note.
Table 4 – Return loss (RL)
Frequency range
...
This May Also Interest You
IEC 62783-1:2023 specifies definitions, requirements and test methods of twinax cables used in digital communication systems: computer rooms, data centres, servers, etc. These cables are intended to be used indoors.
This document details the requirements and transmission characteristics for single twinax elements as well as multiple twinax elements within the same sheath, i.e. “twinax cable”. IEC 62783-1 ED2 is applicable to twinax cables and also twinax cable assemblies. This document is supplemented with family specifications that give additional requirements based on the specific application, for example, the minimum and maximum specified frequency of the cables.
- Standard20 pagesEnglish languagesale 15% off
IEC 61156-11:2023 is available as IEC 61156-11:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-11:2023 describes cables intended to be used for single balanced pair (office, home, industrial) applications according to ISO/IEC 11801-1. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-9906. The transmission characteristics of these cables are specified up to a frequency of 1,25 GHz and at a temperature of 20 °C. The T1-C type cable is specified up to 600 MHz, the T1-D type cable up to 1,25 GHz. Depending on the MICE environment and the installation conditions either unscreened or screened cables can be used. A blank detail specification can be found in Annex A.
- Standard27 pagesEnglish languagesale 15% off
- Standard56 pagesEnglish languagesale 15% off
IEC 61156-1:2023 is available as IEC 61156-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-1:2023 specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. This document is applicable to communication systems such as local area networks (LANs) and data communication cables. It is also applicable to cables used for industrial applications, customer premises wiring and generic cabling comprising installation cables and cables for work area wiring which are defined in ISO/IEC 11801 (all parts). The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example the electric power supplies of public utility mains, they are intended to be used to support the delivery of low voltage remote powering applications including but not restricted to Power over Ethernet as specified in ISO/IEC/IEEE 8802-3.
- Standard173 pagesEnglish languagesale 15% off
- Standard111 pagesEnglish and French languagesale 15% off
IEC 62807-3-10:2023 is a family specification for FTTA (Fibre-To-The-Antenna) outdoor hybrid communication cables. It specifies the design and construction, rated values and characteristics, requirements and test methods, packaging and quality assurance, etc. The FTTA hybrid communication cables are typically but not only installed between the Base Band Unit (BBU) and Remote Radio Unit (RRU; or often called RRH – Remote Radio Head or AAU – Active Antenna Unit), and other scenario that supply electric current to optical communication equipment.
- Standard35 pagesEnglish languagesale 15% off
IEC 61156-7:2023 is available as IEC 61156-7:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61156-7:2023 specifies cables that can be used for various communication systems as well as for analogue systems, such as video, that exist or are under development and which may use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems as well as to enhance present systems. It covers a cable having four individually screened (S/FTP) pairs. The cable can be provided with a common screen over the cable core. This second edition cancels and replaces the first edition published in 2003 and Amendment 1:2012. This edition includes the following significant technical changes with respect to the previous edition:
a. align clauses with IEC 61156-1:2023;
b. remove the clause related to screening attenuation as it is no longer a test to be performed (replaced by coupling attenuation);
c. replace the IEC 62153-4-2 method (injection clamp) with IEC 61156-4-5 (absorbing clamp) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
d. include IEC 62153-4-9 test method (triaxial) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
e. incorporate the blank detail specification.
- Standard26 pagesEnglish languagesale 15% off
- Standard54 pagesEnglish languagesale 15% off
IEC 61156-8:2023 is available as IEC 61156-8:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-8:2023 relates to IEC 61156-1 and IEC 61156-7. The cables described herein are specified up to 1 200 MHz and are specifically designed to build work area cords. It covers a cable having four individually screened (S/FTP) pairs. The cable can be provided with a common screen over the cable core. The cables covered by this sectional specification are intended to operate with voltages and currents normally encountered in communication systems and support the delivery of DC low voltage remote powering applications. These cables are not intended to be used in conjunction with low impedance sources, for example the electric power supply of public utility mains. This second edition cancels and replaces the first edition published in 2009, and Amendment 1:2013. This edition includes the following significant technical changes with respect to the previous edition:
a. align clauses with IEC 61156-1:2023;
b. additional reference to IEC 62153-4-9 test method (triaxial) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
c. incorporation of blank detail specification.
- Standard26 pagesEnglish languagesale 15% off
- Standard53 pagesEnglish languagesale 15% off
IEC 62807-3:2023 is a sectional specification for outdoor hybrid communication cables intended to be used externally in various applications. It specifies terms, definitions, symbols and abbreviated terms, the design and construction, rated values and characteristics, performance requirements and test methods, packaging and quality assurance.
Hybrid cables are designed for networks and customer premises cabling that transmit data, telecommunication, instrumentation, control and signalling services over optical fibres and/or broadband data over coaxial element, wire/pair/quad element and can have the option of supplying electrical current to a remote equipment.
In the IEC 62807 series, the current carrying elements are used only to supply power to the equipment within the communication network. They are not used for electricity distribution or transmission, nor for power supply to domestic appliances. The specific uses are defined in the relevant specification.
The relationship between each of the MICE classifications in ISO/IEC 11801-1, performance requirements and test methods of hybrid cables being proposed in a specific application are fully considered and aligned.
- Standard14 pagesEnglish languagesale 15% off
IEC 62783-1-1:2022 specifies time domain test methods, parameters and requirements for fixtures for twinax cables (known also as twin-axial cables or twin-coaxial cables) used in digital communication systems. The methods and fixtures facilitate measurements of differential and common mode transmission parameters as well as single-ended mode parameters. This document is applicable to twinax cables and also to symmetric cables with pitch.
- Standard12 pagesEnglish languagesale 15% off
IEC TR 62222:2021 describes the test methods for various parameters relating to the reaction to fire properties of metallic and optical fibre communications cables. The parameters have particular importance for cables intended to be installed within buildings and other structures. This document also maps the test methods and associated limits applied to the fire hazards created by particular installation conditions and which can be referenced by other international, regional and national standards. For example, it is important that compliance with the requirements and recommendations for installation methods in ISO/IEC 14763-2 taking into consideration this document improve safety concerning fire.
This third edition cancels and replaces the second edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
- Scope rewritten to clarify and bring into line current understanding from other technical sources;
- Normative References updated to be in line with the most recent technical definitions and new additions;
- new additional terms and definitions added to Annex F since these are not used in the document;
- new inclusions to the list of abbreviated terms, some corrections;
- project reports are now in Annex E, for information only;
- Subclause about mitigation of fire hazards, about fire protection, updated with clearer information on standards plus updates where new standards have been published or amended;
- test methods, test methods conclusions and fire performance updated.
- Technical report45 pagesEnglish languagesale 15% off
IEC 61156-12:2021 describes cables intended to be used for transmission of 1 Gbit/s over a single twisted pair for office, home and industrial application. An example of an existing application is 1000BASE-T1; see ISO/IEC TR 11801-9906. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for the work area wiring of shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF.
The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, e.g. the electric power supplies of public utility mains, they are intended to be used to support the delivery of low voltage remote powering applications.
- Standard25 pagesEnglish languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.