General Information

Abstract

Specifies requirements for the construction and testing of caplights for use in mines susceptible to firedamp (Group I - electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of caplight becoming a source of ignition. The requirements of IEC 60079-0 do not apply unless specified. Is also applicable to caplights intended for use in mines which have become temporarily endangered by an explosive atmosphere of firedamp.

Status
Published
Publication Date
28-Oct-1999
Current Stage
DELPUB - Deleted Publication
Start Date
24-Oct-2005
Completion Date
28-Aug-2026

Buy Documents

Standard

IEC 62013-1:1999 - Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion Released:10/29/1999

ISBN:2-8318-6167-5
English and French language (35 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 62013-1:1999 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the general requirements, construction, and testing methods for caplights used in mines susceptible to firedamp. Firedamp, a naturally occurring explosive gas mixture primarily composed of methane, presents a significant safety risk in mining operations. This standard focuses exclusively on ensuring caplights-the essential lighting devices worn on miners’ helmets-do not become sources of ignition, thereby preventing explosions in hazardous environments.

This standard is designed for caplights used in mines where firedamp is present (classified as Group I electrical apparatus under IEC 60079-0) and also applies in cases where mines temporarily face explosive atmospheres. It outlines critical safety considerations in the design, testing, and marking of caplights to enhance miner safety and compliance with global explosion risk management practices.

Key Topics

  • Scope and Definitions: Defines applicability to caplights intended for mines susceptible to firedamp, emphasizing prevention of ignition risk without imposing all IEC 60079-0 requirements unless explicitly stated.

  • Construction Requirements: Details robust design elements including enclosures resistant to impact, dust, and water ingress to ensure operational integrity under harsh mining conditions.

  • Testing Procedures: Comprehensive test methods include:

    • Impact resistance and drop tests to simulate rough handling
    • Protection against dust and water penetration (IP rating considerations)
    • Verification of non-ignition through fuse and thermal device testing
    • Thermal ignition resistance of cable strands between headpiece and battery
    • Resistance testing for cable sheath materials against fatty acids and fire
    • Electrostatic discharge assessments to prevent static-generated sparks.
  • Overcurrent Protection: Specification of required safeguards to prevent electrical overloads that could cause ignition.

  • Components: Guidelines for critical elements including the headpiece (lamp), battery unit, cable, and external charging contacts to maintain inherent safety.

  • Marking Requirements: Clear labeling protocols to ensure traceability, compliance verification, and user information on safe use.

Applications

IEC 62013-1 is essential for manufacturers, testing laboratories, and safety officers involved in the production and regulation of caplights used in:

  • Underground coal mines and other mining operations where firedamp presents a hazard.
  • Mines temporarily exposed to explosive atmospheres requiring reliable, explosion-proof lighting.
  • Safety equipment suppliers looking to certify and market caplights compliant with international explosion protection standards.
  • Mining companies seeking to ensure worker safety through standardized lighting equipment that minimizes ignition risks.

Implementing this standard helps reduce the incidence of methane-related explosions triggered by faulty or unsafe lighting devices, thereby protecting lives and assets while promoting compliance with mining safety regulations.

Related Standards

  • IEC 60079-0: General requirements for electrical apparatus in explosive gas atmospheres, providing the overarching framework for explosion protection.

  • IEC 60079 Series: Covers various types of explosion protection techniques such as intrinsic safety (i), increased safety (e), and flameproof enclosures (d).

  • ISO/IEC Directives, Part 3: Provides guidance on the structure and drafting of international standards ensuring coherence in documents like IEC 62013-1.

  • National Mining Safety Regulations: Standards such as MSHA (USA) and other regional mining safety codes often reference IEC standards for explosion protection equipment.

By aligning with IEC 62013-1 and complementary standards, the mining industry can effectively manage explosion risks associated with firedamp, ensuring caplights contribute safely to underground illumination needs.


Keywords: IEC 62013-1, caplights, firedamp, mine safety, explosion protection, electrical apparatus, mining lighting standards, ignition risk, caplight testing, underground mines, methane explosion prevention.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 62013-1:1999 - Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion Released:10/29/1999

ISBN:2-8318-6167-5
English and French language (35 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

IEC 62013-1:1999 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion". This standard covers: Specifies requirements for the construction and testing of caplights for use in mines susceptible to firedamp (Group I - electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of caplight becoming a source of ignition. The requirements of IEC 60079-0 do not apply unless specified. Is also applicable to caplights intended for use in mines which have become temporarily endangered by an explosive atmosphere of firedamp.

Specifies requirements for the construction and testing of caplights for use in mines susceptible to firedamp (Group I - electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of caplight becoming a source of ignition. The requirements of IEC 60079-0 do not apply unless specified. Is also applicable to caplights intended for use in mines which have become temporarily endangered by an explosive atmosphere of firedamp.

IEC 62013-1:1999 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 62013-1:1999 has the following relationships with other standards: It is inter standard links to IEC 62013-1:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 62013-1:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
62013-1
INTERNATIONAL
Première édition
STANDARD
First edition
1999-10
Lampes-chapeaux utilisables dans
les mines grisouteuses –
Partie 1:
Règles générales –
Construction et essais en relation avec
le risque d’explosion
Caplights for use in mines susceptible to
firedamp –
Part 1:
General requirements –
Construction and testing in relation to
the risk of explosion
Numéro de référence
Reference number
CEI/IEC 62013-1:2002
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For

devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1

exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
62013-1
INTERNATIONAL
Première édition
STANDARD
First edition
1999-10
Lampes-chapeaux utilisables dans
les mines grisouteuses –
Partie 1:
Règles générales –
Construction et essais en relation avec
le risque d’explosion
Caplights for use in mines susceptible to
firedamp –
Part 1:
General requirements –
Construction and testing in relation to
the risk of explosion
 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
Q
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 62013-1 © CEI:2002
SOMMAIRE
AVANT-PROPOS.4

1 Domaine d’application .6

2 Références normatives.6

3 Définitions .8

4 Généralités.8
4.1 Enveloppes .8
5 Protection contre les surcharges .10
6 Projecteur.12
7 Batterie .14
8 Câble .16
9 Contacts extérieurs de charge .16
10 Vérifications et essais de type .16
10.1 Généralités.16
10.2 Essai de tenue aux chocs .16
10.3 Essai de tenue aux chutes.18
10.4 Essai pour vérifier la protection contre la pénétration de la poussière
et de l'eau.18
10.5 Essai pour vérifier la non-inflammation d'un mélange gazeux électrolytique
représentatif ou de grisou par un fusible ou un disjoncteur thermique.18
10.6 Essai pour vérifier la non-inflammation, par inflammation thermique, d'un
mélange gazeux par un fil du câble situé entre le projecteur et la batterie .18
10.7 Essai pour vérifier la résistance de la gaine du câble aux acides gras.20
10.8 Essai pour vérifier la résistance de la gaine du câble au feu .20
10.9 Essai de résistance à la traction des entrées de câble, des dispositifs
d'amarrage et du câble .20
10.10 Essai d’inflammation à l'éclateur.20
10.11 Evaluation de la température de la résistance de limitation de courant .22
10.12 Essai de fuite de l’électrolyte.22
10.13 Vérification de l’absence de danger du fait de propriétés électrostatiques
liées aux dimensions, à la forme et à l’implantation .22

11 Marquage .26
Figure 1 – Exemple représentatif d’un ensemble lampe-chapeau.30
Figure 2 – Frottement avec un tissu.32
Figure 3 – Décharge d’un boîtier par l’intermédiaire d’une sonde raccordée à la terre
par un condensateur de 0,1 μF .32
Figure 4 – Chargement par influence avec une alimentation haute tension c.c. .34
Tableau 1 – Paramètres pour les essais de tenue aux chocs .28

62013-1 © IEC:2002 – 3 –
CONTENTS
FOREWORD.5

1 Scope.7

2 Normative references.7

3 Definitions .9

4 General .9
4.1 Enclosures .9
5 Overcurrent protection .11
6 Headpiece .13
7 Battery.15
8 Cable.17
9 External charging contacts.17
10 Type verifications and tests.17
10.1 General .17
10.2 Impact test.17
10.3 Drop tests.19
10.4 Test to verify the protection against ingress of dust and water .19
10.5 Test to verify the non-ignition of a representative electrolytic gas mixture or
firedamp by fuse or thermal circuit-breaker.19
10.6 Test to verify the non-ignition of a gas mixture by one strand of the cable
between the headpiece and the battery by thermal ignition .19
10.7 Test to verify the resistance of the cable sheath to fatty acids.21
10.8 Test to verify the resistance of the cable sheath to fire .21
10.9 Test to verify the strength of cable entries, anchoring devices and cable.21
10.10 Spark ignition test .21
10.11 Current-limiting resistor temperature assessment.23
10.12 Electrolyte leakage test .23
10.13 Verification of non-hazardous electrostatic properties by size,
shape and layout.23
11 Marking .27

Figure 1 – A representative caplight assembly.31
Figure 2 – Rubbing with a cloth .33
Figure 3 – Discharging of a container with a probe connected to earth via a 0,1 μF capacitor. 33
Figure 4 – Charging by influence with a d.c. voltage power supply .35
Table 1 – Parameters for impact test.29

– 4 – 62013-1 © CEI:2002
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
LAMPES-CHAPEAUX UTILISABLES DANS LES MINES GRISOUTEUSES –

Partie 1: Règles générales –
Construction et essais en relation avec le risque d’explosion

AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 62013-1 a été établie par le comité 31 de la CEI: Matériel
électrique pour atmosphères explosives.
Cette version bilingue (2002-02) remplace la version monolingue anglaise.
Elle s’appuie sur une combinaison des concepts de protection cités dans la CEI 60079, par
exemple la sécurité augmentée «e» et la sécurité intrinsèque «i» ainsi que sur l’incor-
poration de l’expérience acquise depuis plusieurs années dans le domaine de la prévention
des explosions de gaz.
Le texte anglais de cette norme est basé sur les documents 31/294/FDIS et 31/311/RVD.
Le rapport de vote 31/311/RVD donne toute information sur le vote ayant abouti à l'appro-
bation de cette norme.
La version française de cette norme n'a pas été soumise au vote.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2003.
A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
62013-1 © IEC:2002 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP –

Part 1: General requirements –

Construction and testing in relation to the risk of explosion

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62013-1 has been prepared by IEC technical committee 31:
Electrical apparatus for explosive atmospheres.
This bilingual version (2002-02) replaces the English version.
It is based on a combination of the protective concepts listed in IEC 60079, for example
Increased Safety “e” and Intrinsic Safety “i” as well as incorporating operating experience
gained over many years in the field of gas ignition prevention.
The text of this standard is based on the following documents:

FDIS Report on voting
31/294/FDIS 31/311/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
The committee has decided that this publication remains unchanged until 2003. At this date,
the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition; or
• amended.
– 6 – 62013-1 © CEI:2002
LAMPES-CHAPEAUX UTILISABLES DANS LES MINES GRISOUTEUSES –

Partie 1: Règles générales –
Construction et essais en relation avec le risque d’explosion

1 Domaine d’application
Cette partie de la CEI 62013 spécifie les règles pour la construction et les essais des lampes-

chapeaux utilisables dans les mines grisouteuses (Groupe I – matériels électriques pour les

atmosphères explosives gazeuses comme définies dans la CEI 60079-0). Elle traite
uniquement du risque présenté par une lampe-chapeau de devenir une source d’inflam-
mation. Les règles de la CEI 60079-0 ne s’appliquent pas à moins que cela ne soit spécifié.
La présente norme est aussi applicable pour une utilisation dans les mines qui sont
temporairement mises en danger par la présence d’une atmosphère explosive grisouteuse.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60050(845):1987, Vocabulaire Electrotechnique International (VEI) – Chapitre 845:
Eclairage
CEI 60079-0:1998, Matériel électrique pour atmosphères explosives gazeuses – Partie 0:
Règles générales
CEI 60079-7:1990, Matériel électrique pour atmosphères explosives gazeuses – Partie 7:
Sécurité augmentée «e»
CEI 60079-11:1999, Matériel électrique pour atmosphères explosives gazeuses – Partie 11:
Sécurité intrinsèque «i»
CEI 60079-20:1996, Matériels électriques pour atmosphères explosives gazeuses – Partie 20:
Données pour gaz et vapeurs inflammables en relation avec l'utilisateur des matériels
électriques
CEI 60112:1979, Méthode pour déterminer des indices de résistance et de tenue au
cheminement des matériaux isolants solides dans des conditions humides
CEI 60127-2:1989, Coupe-circuit miniatures – Deuxième partie: Cartouches
CEI 60332-1:1993, Essais des câbles électriques soumis au feu – Partie 1: Essais sur un
conducteur ou câble isolé vertical
CEI 60455-1:1998, Composés réactifs à base de résine utilisés comme isolants électriques –
Partie 1: Définitions et prescriptions générales
CEI 60529:1989, Degrés de protection procurés par les enveloppes (Code IP)

62013-1 © IEC:2002 – 7 –
CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP –

Part 1: General requirements –

Construction and testing in relation to the risk of explosion

1 Scope
This part of IEC 62013 specifies requirements for the construction and testing of caplights

for use in mines susceptible to firedamp (Group I – electrical apparatus for explosive gas

atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a
source of ignition. The requirements of IEC 60079-0 do not apply unless specified.
This standard is also applicable to caplights intended for use in mines which have become
temporarily endangered by an explosive atmosphere of firedamp.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60050(845):1987, International Electrotechnical Vocabulary (IEV) – Chapter 845: Lighting
IEC 60079-0:1998, Electrical apparatus for explosive gas atmospheres – Part 0: General
requirements
IEC 60079-7:1990, Electrical apparatus for explosive gas atmospheres – Part 7: Increased
safety "e"
IEC 60079-11:1999, Electrical apparatus for explosive gas atmospheres – Part 11: Intrinsic
safety "i"
IEC 60079-20:1996, Electrical apparatus for explosive gas atmospheres – Part 20: Data for
flammable gases and vapours, relating to use of electrical apparatus
IEC 60112:1979, Method for determining the comparative and the proof tracking indices of
solid insulating, materials under moist conditions

IEC 60127-2:1989, Miniature fuses – Part 2: Cartridge fuse-links
IEC 60332-1:1993, Tests on electric cables under fire conditions – Part 1: Test on a single
vertical insulated wire or cable
IEC 60455-1:1998, Resin based reactive components used for electrical insulation – Part 1:
Definitions and general requirements
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)

– 8 – 62013-1 © CEI:2002
3 Définitions
Pour les besoins de la présente partie de la CEI 62013, les définitions de la CEI 60079-0 et

de la CEI 60050(845) sont applicables, ainsi que les définitions indiquées ci-après.

3.1
batterie
deux ou plusieurs éléments connectés entre eux et convenant pour l'utilisation comme source
d'énergie
3.2
boîtier de batterie
enveloppe de la batterie et tout couvercle additionnel fixé à celle-ci
3.3
lampe-chapeau
matériel comprenant un projecteur, un câble de liaison et un ou des accumulateurs dans un
boîtier (voir figure 1)
3.4
élément
ensemble d'électrodes et d'électrolyte contenus dans une enveloppe, qui constitue l'unité de
base d'un accumulateur
3.5
grisou
mélange de gaz inflammables survenant naturellement dans une mine (ayant les caracté-
ristiques données dans la CEI 60079-20)
3.6
élément «étanche»
élément dont l'étanchéité reste assurée quand il fonctionne dans ses limites spécifiées mais
qui permet l'échappement des gaz par un dispositif répétitif ou non d’échappement de la
pression lorsque la pression intérieure dépasse une valeur prédéterminée
3.7
accumulateur
système électrochimique capable d'accumuler sous forme chimique l'énergie électrique reçue
et de la restituer par transformation inverse
4 Généralités
4.1 Enveloppes
4.1.1 Les enveloppes réalisées en alliage léger doivent être conformes au 8.1 de la
CEI 60079-0.
4.1.2 Les enveloppes réalisées en matière plastique doivent être conformes au 7.3 de la
CEI 60079-0.
Si la protection contre l’inflammation par des charges électrostatiques dangereuses est basée
sur la taille, la forme et la disposition, cela doit être vérifié en accord avec une des méthodes
décrites au 10.13.
Dans le cas de l’essai décrit en 10.13.1, la capacité mesurée ne doit pas dépasser 50 pF.
Dans le cas de l’essai décrit en 10.13.2, la plus grande valeur de charge Q1, Q2 ou Q3 ne doit
pas dépasser 60 nC.
62013-1 © IEC:2002 – 9 –
3 Definitions
For the purposes of this part of IEC 62013, the definitions of IEC 60079-0, IEC 60050(845) and

the following apply.
3.1
battery
two or more cells electrically connected and suitable for use as a source of energy

3.2
battery container
battery enclosure and any additional cover attached to it
3.3
caplight
apparatus comprising a headpiece, connecting cable and rechargeable secondary cell(s)/
battery in a container (see figure 1)
3.4
cell
assembly of electrodes and electrolyte in an enclosure which constitutes the basic unit of a
battery
3.5
firedamp
flammable mixture of gases naturally occurring in a mine (having characteristics as referenced
in IEC 60079-20)
3.6
"sealed" cell
cell which remains closed when it is operated within its specified design limits but permits the
escape of gas through either a resetting or a non-resetting pressure release device if the
internal pressure exceeds a predetermined value
3.7
secondary cell or battery
electrochemical system capable of storing under chemical form the electrical energy received
and which can give it back by reconversion
4 General
4.1 Enclosures
4.1.1 Enclosures made of light alloy shall conform to 8.1 of IEC 60079-0.
4.1.2 Enclosures made of plastic material shall conform to 7.3 of IEC 60079-0.
If the protection against ignition by dangerous electrostatic charges is by virtue of size, shape
and layout, this shall be verified in accordance with one of the methods described in 10.13.
In the case of the test described in 10.13.1, the capacitance measured shall not exceed 50 pF.
In the case of the test described in 10.13.2, the highest value of charge Q1, Q2 or Q3 shall not
exceed 60 nC.
– 10 – 62013-1 © CEI:2002
4.2 Les connexions électriques internes doivent être conformes au 4.2 de la CEI 60079-7.

4.3 Les matériaux isolant solides doivent être conformes au 4.5 de la CEI 60079-7.

4.4 Le câblage interne doit être conforme au 4.8 de la CEI 60079-7.

4.5 La lampe-chapeau doit être construite de telle manière que le circuit (sans autre

matériel connecté)
– se comporte comme s'il était uniquement résistif et

– comprenne les moyens pour prévenir l’inflammation du grisou par effets thermiques ou par
des arcs.
4.6 Lorsque la batterie de la lampe-chapeau est également utilisée pour l'alimentation d'un
autre matériel, l'autre matériel doit être conforme aux règles d'un ou de plusieurs des modes
de protection cités dans la CEI 60079-0 et l'association doit être approuvée comme un tout
afin d’assurer que ni la lampe-chapeau ni le matériel n'affecte défavorablement le mode de
protection fourni par chacun.
4.7 Lignes de fuite et les distances dans l’air: toutes les connexions filaires et les pistes de
circuits imprimés qui peuvent affecter le mode de protection procuré doivent être considérées
comme ayant des séparations infaillibles si elles répondent aux exigences suivantes pour les
lignes de fuite et distances dans l’air:
– 1,6 mm dans l’air;
– 0,5 mm au travers d’un isolant solide ou sous un revêtement;
– tous les matériaux d’isolation doivent avoir un indice de résistance au cheminement (IRC)
d’au moins 175 (lorsqu’il est essayé selon la CEI 60112).
4.8 Il ne doit pas être possible d’obtenir un courant plus grand que 50 mA entre deux points
accessibles de la lampe-chapeau lorsque qu’elle est assemblée pour l’utilisation.
5 Protection contre les surcharges
5.1 Une protection contre les surcharges doit être fournie, qui limite efficacement le courant
de décharge à un niveau non susceptible de provoquer l’inflammation d’une atmosphère
rendue dangereuse par le grisou. Une telle protection doit être procurée par un ou plusieurs
des moyens suivants et doit être conforme au 5.2, ou au 5.3 et au 5.4, ou au 5.3 et au 5.5, et
en plus au 5.6:
a) un fusible ou un disjoncteur thermique;

b) le choix d’une batterie possédant des caractéristiques internes telles qu’elle ne soit pas
capable d’enflammer le gaz d’essai lorsqu’elle est essayée conformément au 10.10;
c) une résistance de limitation du courant infaillible conforme au 3.9 de la CEI 60079-11;
d) un dispositif actif de limitation de courant examiné en fonction de la CEI 60079-11.
Si le courant de charge de la batterie traverse le moyen de protection, les caractéristiques
doivent être fonction du plus grand des courants de charge ou de décharge.
5.2 Lorsque le moyen de protection contre les surcharges est un fusible ou un disjoncteur
thermique et que la lampe-chapeau est construite de telle manière que
– la tension nominale ne dépasse pas 6 V;
– l'intensité du courant normal d'utilisation ne dépasse pas 1,5 A;
– la puissance nominale de la lampe ne dépasse pas 6 W

62013-1 © IEC:2002 – 11 –
4.2 Internal electrical connections shall conform to 4.2 of IEC 60079-7.

4.3 Solid electrical insulating materials shall conform to 4.5 of IEC 60079-7.

4.4 Internal wiring shall conform to 4.8 of IEC 60079-7.

4.5 The caplight shall be constructed in such a manner that the circuit (without another
apparatus connected)
– behaves as if solely resistive, and

– incorporates means to prevent ignition of firedamp by thermal effects or arcing.

4.6 Where the caplight is also used to supply electrical power to another apparatus, the other
apparatus shall conform to the requirements of one or more of the types of protection listed in
IEC 60079-0 and the combination of the caplight and other apparatus shall be assessed as a
whole to ensure that neither the caplight nor the apparatus adversely affects the type of
explosion protection provided by each.
4.7 Creepage and clearance distances – all wiring connections and printed wiring boards
which can affect the type of protection afforded shall be considered to have infallible
separations if they meet the following creepage and clearance requirements:
– 1,6 mm in air;
– 0,5 mm through solid insulation or under a coating;
– all insulating materials shall have a Comparative Tracking Index (CTI) of at least 175 (when
tested in accordance with IEC 60112).
4.8 It shall not be possible to obtain a current of greater than 50 mA between any two
accessible points of the caplight when assembled for use.
5 Overcurrent protection
5.1 Overcurrent protection shall be provided which effectively limits the discharge current to
a level unlikely to cause an ignition of an atmosphere endangered by firedamp. Such protection
shall be provided by one or more of the following means, and shall conform to 5.2, or to 5.3
and 5.4, or to 5.3 and 5.5, and additionally to 5.6:
a) a fuse or thermal circuit-breaker;
b) selecting a battery with appropriate internal characteristics so that it is not capable of
igniting the test gas when tested in accordance with 10.10;

c) an infallible current-limiting resistor conforming to 3.9 of IEC 60079-11;
d) an active current-limiting device assessed to IEC 60079-11.
If the battery-charging current passes through the protective means, the rating of that means
shall be based on the charge current or discharge current, whichever is the greater.
5.2 Where the means of overcurrent protection is a fuse or thermal circuit-breaker and the
caplight is constructed in such a manner that
– the nominal voltage is not greater than 6 V;
– the value of the current in normal use is not greater than 1,5 A, and
– the nominal rating of the lamp is not greater than 6 W

– 12 – 62013-1 © CEI:2002
le fusible ou le disjoncteur thermique doit être conforme aux exigences suivantes:

a) le fusible ou le disjoncteur thermique doit être protégé de telle façon que, lorsqu’il est

essayé selon 10.5, il n’y ait pas d’inflammation du mélange de gaz environnant,

NOTE  Un exemple de protection valable est l'encapsulage, sauf des sorties, dans un compound approprié

(voir 4.21 de la CEI 60455-1) ayant une épaisseur minimale de couche de 1 mm.

et
b) le fusible doit être conforme avec la CEI 60127-2 et doit répondre de plus aux exigences

suivantes:
Les courants et les temps de fusion ou de coupure doivent être aussi faibles que possible par

rapport aux caractéristiques courant/temps de charge et décharge de la batterie.

– temps de fusion ou de coupure à 12 A ± 0,1 A: pas plus de 1 s et
– temps de fusion ou de coupure à 15 A ± 0,1 A: pas plus de 200 ms.
5.3 Dans tous les cas, autres que le 5.2 ci-dessus, l’association de la batterie et des
moyens de protection doit être conforme aux règles de la CEI 60079-11 concernant l’essai
d’inflammation à l'éclateur décrit au 10.10.
5.4 Lorsque le moyen de protection contre les surcharges est une ou des résistances, il doit
être relié au circuit le plus près possible des connexions de la batterie.
De plus, la ou les résistances doivent:
a) être de type métallique ou couche d’oxyde métallique ou bobinées à simple couche avec
une protection mécanique pour éviter le débobinage du fil dans l’éventualité d’une rupture,
ou être de construction équivalente possédant un mode de défaillance qui augmente la
résistance;
b) fonctionner à pas plus des deux tiers de leur puissance assignée en fonctionnement normal.
5.5 Lorsque la protection de surintensité est réalisée par des limiteurs de courant actifs, il
faut utiliser deux limiteurs en série conformément à 7.1 de la CEI 60079-11. Cette disposition
ne préjuge pas de l’utilisation d’un dispositif actif et d’un fusible en série, conformément à 5.2.
5.6 La disposition physique des moyens de protection contre les surintensités et du câble à
l’intérieur du boîtier de la batterie doit être telle qu’il soit improbable qu’un court-circuit
passant ailleurs qu’à travers les circuits de protection puisse se produire.
6 Projecteur
6.1 L'enveloppe du projecteur de la lampe-chapeau doit assurer au moins le degré de
protection IP54 (catégorie 2) contre la pénétration de la poussière et de l'eau conformément à
la CEI 60529.
L'enveloppe du projecteur, lorsqu’elle est essayée conformément à 10.4.1, doit être conforme
à 10.4.2 et 10.4.3.
6.2 Le projecteur doit être muni d’un dispositif de verrouillage ou de fermetures spéciales
pour prévenir l’accès sans autorisation aux parties internes.
6.3 La lampe doit être protégée par un couvercle de protection transparent qui répond aux
exigences du tableau 1 et qui peut posséder un bourrelet de protection. Le couvercle de
protection doit être également muni d’une grille de protection sauf si:
a) la surface libre du couvercle de protection ne dépasse pas 35 cm ; ou
b) le couvercle de protection résiste à l’essai de tenue aux chocs selon 10.2 avec l’énergie
de choc prévue pour le couvercle de protection sans grille de protection; ou
c) le projecteur est muni d’un moyen de coupure automatique de l’alimentation de tous les
filaments en cas de rupture du couvercle de protection ou de l’enveloppe de la lampe.

62013-1 © IEC:2002 – 13 –
the fuse or thermal circuit-breaker shall conform to the following requirements:

a) the fuse or thermal circuit-breaker shall be protected so that, when tested according to

10.5, there is no ignition of any surrounding gas mixture,

NOTE An example of such suitable protection is to cover, except for the terminations, with an appropriate

encapsulation compound (see 4.21 of IEC 60455-1) with a minimum thickness of 1 mm.

and
b) the fuse shall comply with IEC 60127-2 and additionally meet the following criteria.

The fusing or interrupting current and fusing or interrupting time shall be as small as possible

with regard to the current/time charging and discharging characteristics of the battery. The

following rules shall apply:
– fusing or interrupting time at 12 A ± 0,1 A: not more than 1 s, and
– fusing or interrupting time at 15 A ± 0,1 A: not more than 200 ms.
5.3 In all cases, other than 5.2 above, the combination of the battery and the means of
protection shall conform to the requirements of IEC 60079-11 using the spark ignition test
described in 10.10.
5.4 Where the means of overcurrent protection is a resistor or resistors, it shall be connected
into the circuit as near to the battery terminals as possible.
Furthermore, the resistor(s) shall
a) be of the metal or metal oxide film type, or of the single-layer wire-wound type with
mechanical protection to prevent unwinding of the wire in the event of breakage, or any
similar construction which has a failure mode that increases resistance;
b) operate at no more than two-thirds of its power rating under normal operation.
5.5 When the overcurrent protection is made by active current-limiting devices, two devices
in accordance with 7.1 of IEC 60079-11 in series shall be used. This does not preclude the use
of one active device and a fuse, complying with 5.2, in series.
5.6 The physical arrangement of the means of overcurrent protection and the cable within the
battery container shall be such that a short-circuit current not passing through the means of
protection is unlikely.
6 Headpiece
6.1 The enclosure of the headpiece of the caplight shall provide a degree of protection
against the ingress of dust and water of at least IP54 (category 2) as specified in IEC 60529.

When tested in accordance with 10.4.1, the headpiece enclosure shall conform to 10.4.2 and
10.4.3.
6.2 The headpiece shall be provided with an interlocking device or special fastener to
prevent unauthorized access to the internal parts.
6.3 The lamp shall be protected by a protective cover which is light transmitting, meets the
requirements of table 1 and may have a protective rim. The protective cover shall be fitted
additionally with a protective grill unless
a) the free surface of the protective cover does not exceed 35 cm ; or
b) the protective cover withstands the impact test according to 10.2 with the impact energy for
the protection cover without the protective grill; or
c) the headpiece is fitted with means to cut off automatically the power supply to all filaments
when either the protective cover or the lamp envelope breaks.

– 14 – 62013-1 © CEI:2002
6.4 Le couvercle de protection et la grille de protection spécifiée en 6.3 ne doivent pouvoir
être déposés qu’après avoir manœuvré le dispositif de verrouillage ou l’attache spéciale

spécifiée en 6.2.
6.5 Lorsque le projecteur est équipé d'une ou de plusieurs lampes à filament unique, ou bien:

a) une distance d'au moins 1 mm doit être assurée entre chaque lampe dans sa position

correcte de fonctionnement et le disque de protection, ou encore;

b) la ou les lampes doivent être maintenues de manière que l'alimentation en énergie de la

ou des lampes soit automatiquement coupée si le disque de protection se rompt.

6.6 Lorsque le projecteur est équipé d'une ou de plusieurs lampes à deux ou plusieurs fila-
ments il doit être conçu pour que l'alimentation en énergie de chaque filament soit automa-
tiquement coupé si le disque de protection ou l'enveloppe de la lampe se rompt, par exemple
en éjectant la lampe de son support.
6.7 Tous les contacts électriques doivent assurer un contact efficace et fiable ils doivent être
conformes à 4.2 de la CEI 60079-7, à l'exception des contacts à ressort qui sont autorisés en
tant qu'éléments transmettant le courant dans le ou les circuits de la ou des lampes.
7 Batterie
7.1 Le boîtier de la batterie doit assurer la protection des connexions électriques contre
la pénétration de la poussière et de l'eau suivant au moins le degré de protection IP54
(catégorie 2) conformément à la CEI 60529. Lorsqu’il est essayé en conformité avec 10.4.1,
le boîtier de la batterie doit être en conformité avec 10.4.2 et 10.4.3
7.2 Le boîtier de la batterie doit être équipé d’un dispositif de verrouillage ou d’un dispositif
de fermeture spécial de façon à empêcher l’accès aux contacts électriques.
7.3 Le boîtier de la batterie ou l'élément doit comporter au moins un dispositif de décharge
de pression approprié.
La pression au-dessus de la pression atmosphérique à l'intérieur du boîtier de la batterie et
des éléments ne doit pas dépasser 30 kPa (0,3 bar). Dans les éléments «étanches», une
pression plus élevée est admissible, mais chaque élément doit alors être muni d'un dispositif
de décharge de pression ou autre moyen permettant de limiter la pression à une valeur qui
peut être supportée par l'élément, telle que définie par le fabricant de l’élément.
Sauf si le fabricant de la lampe-chapeau peut démontrer que la teneur en hydrogène dans le
volume libre à l'intérieur du boîtier de la batterie ne peut dépasser 2 % en volume, les orifices
pour l'évacuation des gaz de chaque élément doivent être conçus de telle sorte que les gaz
qui s'échappent ne pénètrent pas dans une enveloppe de matériel contenant des connexions
ou des composants électriques ou
...