IEC 61300-2-21:2026
(Main)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
- Abstract
IEC 61300-2-21:2026 defines the resistance of a fibre optic device or component to the deteriorative effects of high temperature, humidity and cold conditions. It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and fissures as well as condensation. However, the degree of condensation will vary depending on the size and thermal mass of the DUT.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of the terms and definitions and of the details to be specified and reported;
b) update of Figure 1 and Figure 2 according to IEC 60068-2-38.
- Status
- Published
- Publication Date
- 15-Nov-2026
- Technical Committee
- SC 86B - Fibre optic interconnecting devices and passive components
- Drafting Committee
- WG 4 - TC 86/SC 86B/WG 4
- Current Stage
- PPUB - Publication issued
- Start Date
- 16-Nov-2026
- Completion Date
- 04-Dec-2026
Buy Documents
IEC 61300-2-21:2026 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
REDLINE IEC 61300-2-21:2026 RLV - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
IEC 61300-2-21:2026 - Dispositifs d'interconnexion et composants passifs fibroniques - Procédures fondamentales d'essais et de mesures - Partie 2-21: Essais - Essai cyclique composite de température et d'humidité
IEC 61300-2-21:2026 is an IEC International Standard for fibre optic interconnecting devices and passive components. It specifies a composite temperature/humidity cyclic test used to assess resistance to high temperature, humidity, and cold, and to reveal defects caused by breathing, trapped moisture, freezing in cracks and fissures, and condensation. Engineers, test laboratories, and specification writers use it with IEC 61753 or IEC 62005 performance or reliability requirements.
What does IEC 61300-2-21:2026 specify?
IEC 61300-2-21:2026 defines the test method, the chamber conditions, the specimen preparation, the measurements, and the reporting items for a composite temperature/humidity cyclic test. It is based on IEC 60068-2-38, test Z/AD, and is organized into clauses 1 to 8, plus a bibliography and two figures.
The document covers:
- the scope and purpose of the test
- the standards referenced for preparation, measurement, and acceptance
- the apparatus needed for humid and cold exposure
- the procedure for preconditioning, cycling, recovery, and final checks
- the severity definition and the items that must be reported
What are the key requirements of IEC 61300-2-21:2026?
IEC 61300-2-21:2026 is built around a 10-cycle environmental sequence, with each cycle lasting 24 h. The first nine cycles include cold exposure in any five cycles after the humidity subcycle, and the final cycle ends after the humidity exposure and a recovery hold before final measurements.
Test sequence and severity
Clause 4 and Clause 7 describe why the test is severe and how severity is defined. The severity combines humidity level, exposure time, cold temperature, cycle duration, and the number and position of cold cycles.
In practice, the laboratory must program the exact cycle sequence required by the relevant product specification and confirm whether the standard 10-cycle sequence applies. If the relevant specification changes the number or position of cold cycles, that specification has to define it.
Chamber and equipment requirements
Clause 5 sets the chamber conditions. The humid chamber must move between 25 °C and 65 °C within the stated time limits, hold the specified relative humidity during rising, constant, and falling temperature periods, and prevent radiant heat or falling condensate from reaching the DUT. The cold chamber must hold -10 °C for 3 h, with uniform conditions and continuous air movement.
Clause 5 also allows the cold exposure to be done in one combined chamber or in two separate chambers. When two chambers are used, the document warns against unintended thermal shock unless the DUT is known to tolerate it. That matters because a poor chamber setup can create failures that come from handling or transfer, not from the intended test severity.
Specimen preparation and preconditioning
Clause 6.1 and 6.2 require the DUT to be prepared according to IEC 61300-1, cleaned according to the manufacturer’s instructions, and connected to the optical source and detector. Unless otherwise specified, the DUT is preconditioned for 24 h at 55 °C and not more than 20 % RH, then allowed to stabilize at standard atmospheric conditions before baseline measurements.
For the reader, this means the sample must be in a repeatable ready-for-use state before the test begins. The preconditioning step is there to drive out prior moisture history so the test starts from a controlled condition.
Measurements before, during, and after the test
Clause 6.3 requires initial visual, optical, and any mechanical checks called for by the relevant specification. Visual examination follows IEC 61300-3-1, and optical measurements are taken at the wavelength(s) defined by the relevant IEC 61753 performance standard or IEC 62005 reliability document.
Clause 6.4.3 requires examinations and measurements during the test to follow the same performance or reliability document. Clause 6.6 then requires final visual examination and final optical measurements, either immediately after removal from the chamber or after a drying period, depending on the relevant specification. The results must meet the acceptance criteria set by the applicable performance or reliability document.
What the cycle actually does
Clause 6.4.2 describes the 24 h cycle in detail. The DUT is exposed to repeated transitions between 25 °C and 65 °C at controlled humidity, with a cold subcycle at -10 °C in selected cycles. If the DUT is moved between chambers, the transfer has to be completed within the stated short time window.
In practice, this is the part that the test engineer programs into the chamber controller and records in the test report. The timing matters because the standard is checking both temperature cycling and moisture behavior under rapid change.
Recovery and reporting
Clause 6.5 requires the DUT to remain at standard atmospheric conditions for at least 2 h after the final cycle. Clause 8 lists the details that must be specified and reported, including preconditioning, recovery, severity, the examination and measurement plan, additional pass/fail criteria, and any deviations from the procedure.
That reporting requirement matters because the same test method can be run with different product-specific acceptance rules. The report has to show exactly what was done and how pass or fail was decided.
What terms does IEC 61300-2-21:2026 define?
IEC 61300-2-21:2026 uses the terms and definitions from IEC 61300-1. The most important terms for day-to-day use are:
- Device under test (DUT) - the fibre optic device or component being exposed, measured, and assessed.
- Ready-for-use state - the condition of the DUT before conditioning, as prepared for normal service use.
- Relative humidity (RH) - the humidity control level used throughout the temperature/humidity subcycles.
- Standard atmospheric conditions for testing - the ambient conditions used for stabilization, recovery, and some measurements.
- Attenuation - the optical loss that is monitored for change during and after exposure.
- Return loss - the reflected optical signal parameter monitored together with attenuation.
- Thermal shock - the sudden temperature change risk that can occur when separate chambers are used for hot and cold exposure.
Who uses IEC 61300-2-21:2026?
IEC 61300-2-21:2026 is used by manufacturers of fibre optic interconnecting devices and passive components, environmental test laboratories, qualification and reliability engineers, and quality managers. It is also used by specification writers and certification bodies that need a common test method for comparing products.
In practice, they use it to:
- qualify product resistance to humidity and cold cycling
- set up laboratory test programmes
- define preconditioning, measurements, and acceptance criteria
- document pass/fail results for product specifications based on IEC 61753 or IEC 62005
What changed in IEC 61300-2-21:2026 from the previous edition?
IEC 61300-2-21:2026 cancels and replaces IEC 61300-2-21:2009 and is a technical revision. The stated changes are:
- update of the terms and definitions and of the details to be specified and reported
- update of Figure 1 and Figure 2 according to IEC 60068-2-38
Which standards are used with IEC 61300-2-21:2026?
| Standard | What it contributes |
|---|---|
| IEC 60068-2-38 | The environmental test basis for the composite temperature/humidity cyclic test, including test Z/AD |
| IEC 61300-1 | General guidance, specimen preparation, recovery conditions, and the terms and definitions used here |
| IEC 61300-3-1 | Visual examination before and after conditioning |
| IEC 61300-3-3 | Optical source and detector requirements for monitoring attenuation and return loss |
| IEC 61753 (all parts) | Performance criteria, measurement wavelengths, and acceptance limits for product qualification |
| IEC 62005 (all parts) | Reliability criteria and acceptance limits for product reliability documents |
What does the IEC 61300-2-21:2026 document contain?
IEC 61300-2-21:2026 contains the apparatus requirements for humid and cold chambers, the detailed 24 h cycle sequence, the optional cold subcycle, and the final recovery and measurement steps. Figure 1 shows the preconditioning step, and Figure 2 shows the exposure sequence with humidity followed by cold.
The document also identifies what has to be measured before, during, and after the test, and how those results are linked to the relevant IEC 61753 or IEC 62005 document. It is therefore a test method document rather than a product performance standard.
Relations
- Effective Date
- 05-Sep-2023
Buy Documents
IEC 61300-2-21:2026 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
REDLINE IEC 61300-2-21:2026 RLV - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
IEC 61300-2-21:2026 - Dispositifs d'interconnexion et composants passifs fibroniques - Procédures fondamentales d'essais et de mesures - Partie 2-21: Essais - Essai cyclique composite de température et d'humidité
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61300-2-21:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test". This standard covers: IEC 61300-2-21:2026 defines the resistance of a fibre optic device or component to the deteriorative effects of high temperature, humidity and cold conditions. It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and fissures as well as condensation. However, the degree of condensation will vary depending on the size and thermal mass of the DUT. This edition includes the following significant technical changes with respect to the previous edition: a) update of the terms and definitions and of the details to be specified and reported; b) update of Figure 1 and Figure 2 according to IEC 60068-2-38.
IEC 61300-2-21:2026 defines the resistance of a fibre optic device or component to the deteriorative effects of high temperature, humidity and cold conditions. It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and fissures as well as condensation. However, the degree of condensation will vary depending on the size and thermal mass of the DUT. This edition includes the following significant technical changes with respect to the previous edition: a) update of the terms and definitions and of the details to be specified and reported; b) update of Figure 1 and Figure 2 according to IEC 60068-2-38.
IEC 61300-2-21:2026 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61300-2-21:2026 has the following relationships with other standards: It is inter standard links to IEC 61300-2-21:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61300-2-21:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61300-2-21 ®
Edition 3.0 2026-11
INTERNATIONAL
STANDARD
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures -
Part 2-21: Tests - Composite temperature/humidity cyclic test
ICS 33.180.20 ISBN 978-2-8327-1608-3
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or
by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either
IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright
or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local
IEC member National Committee for further information.
IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Discover our powerful search engine and read freely all the
The advanced search enables to find IEC publications by a publications previews, graphical symbols and the glossary.
variety of criteria (reference number, text, technical With a subscription you will always have access to up to date
committee, …). It also gives information on projects, content tailored to your needs.
replaced and withdrawn publications.
Electropedia - www.electropedia.org
The world's leading online dictionary on electrotechnology,
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published containing more than 22 500 terminological entries in English
details all new publications released. Available online and and French, with equivalent terms in 25 additional languages.
once a month by email. Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer
Service Centre: sales@iec.ch.
CONTENTS
FOREWORD . 2
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 General . 4
5 Apparatus . 5
5.1 General . 5
5.2 Chamber for the exposure to high temperature and humidity . 5
5.3 Chamber for exposure to cold . 5
5.4 Temperature and humidity chamber . 6
5.4.1 General . 6
5.4.2 Optical measurement equipment . 6
6 Procedure . 6
6.1 Preparation of DUT . 6
6.2 Preconditioning . 6
6.3 Initial examinations and measurements . 7
6.4 Conditioning . 8
6.4.1 General . 8
6.4.2 Description of a 24 h cycle . 8
6.4.3 Examinations and measurements during the test . 11
6.5 Recovery . 11
6.6 Final examinations and measurements . 11
7 Severity . 11
8 Details to be specified and reported. 12
Bibliography . 13
Figure 1 – Preconditioning . 7
Figure 2 – Exposure to high temperature and humidity followed by exposure to cold. 10
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures -
Part 2-21: Tests - composite temperature/humidity cyclic test
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 61300-2-21 has been prepared by subcommittee 86B: Fibre optic interconnecting devices
and passive components, of IEC technical committee 86: Fibre optics. It is an International
Standard.
This third edition cancels and replaces the second edition published in 2009. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) update of the terms and definitions and of the details to be specified and reported;
b) update of Figure 1 and Figure 2 according to IEC 60068-2-38.
The text of this International Standard is based on the following documents:
Draft Report on voting
86B/5264/FDIS 86B/5299/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all the parts of IEC 61300 series, under the general title, Fibre optic interconnecting
devices and passive components - Basic test and measurement procedures, can be found on
the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
1 Scope
This part of IEC 61300 defines the resistance of a fibre optic device or component to the
deteriorative effects of high temperature, humidity and cold conditions.
It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to
absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and
fissures as well as condensation. However, the degree of condensation will vary depending on
the size and thermal mass of the DUT.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61300-1, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 1: General and guidance
IEC 61300-3-1, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 61300-3-3, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of
changes in attenuation and return loss
IEC 61753 (all parts), Fibre optic interconnecting devices and passive components -
Performance standards
IEC 62005 (all parts), Fibre optic interconnecting devices and passive components - Reliability
3 Terms and
...
IEC 61300-2-21 ®
Edition 3.0 2026-11
INTERNATIONAL
STANDARD
REDLINE VERSION
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures -
Part 2-21: Tests - Composite temperature/humidity cyclic test
ICS 33.180.20 ISBN 978-2-8327-1627-4
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or
by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either
IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright
or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local
IEC member National Committee for further information.
IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Discover our powerful search engine and read freely all the
The advanced search enables to find IEC publications by a publications previews, graphical symbols and the glossary.
variety of criteria (reference number, text, technical With a subscription you will always have access to up to date
committee, …). It also gives information on projects, content tailored to your needs.
replaced and withdrawn publications.
Electropedia - www.electropedia.org
The world's leading online dictionary on electrotechnology,
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published containing more than 22 500 terminological entries in English
details all new publications released. Available online and and French, with equivalent terms in 25 additional languages.
once a month by email. Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer
Service Centre: sales@iec.ch.
CONTENTS
FOREWORD . 2
1 Scope . 1
2 Normative references . 4
3 Terms and definitions . 4
4 General . 4
5 Apparatus . 5
5.1 General . 5
5.2 Chamber for the exposure to high temperature and humidity . 5
5.3 Chamber for exposure to cold . 5
5.4 Temperature and humidity chamber . 6
5.4.1 General . 6
5.4.2 Optical source and detector measurement equipment . 6
6 Procedure . 6
6.1 Preparation of specimens DUT . 6
6.2 Preconditioning . 6
6.3 Initial examinations and measurements . 7
6.4 Conditioning . 8
6.4.1 General . 8
6.4.2 Description of a 24 h cycle . 8
6.4.3 Examinations and measurements during the test . 12
6.5 Recovery . 12
6.6 Final examinations and measurements . 12
5.5.1 General .
5.5.2 Immediately upon removal from the chamber .
5.5.3 After final drying .
7 Severity . 13
8 Details to be specified and reported. 13
Bibliography . 12
Figure 1 – Preconditioning . 7
Figure 2 – Exposure humidity followed by exposure to cold.
Figure 2 – Exposure to high temperature and humidity followed by exposure to cold. 11
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures -
Part 2-21: Tests - composite temperature/humidity cyclic test
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
This redline version of the official IEC Standard allows users to identify the changes made since
the previous edition, IEC 61300-2-21:2009. A vertical bar appears in the margin wherever a
change has been made. Additions are shown in green text, and deletions are shown in red
strikethrough text.
IEC 61300-2-21 has been prepared by subcommittee 86B: Fibre optic interconnecting devices
and passive components, of IEC technical committee 86: Fibre optics. It is an International
Standard.
This third edition cancels and replaces the second edition published in 2009. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) update of the terms and definitions and of the details to be specified and reported ;
b) update of Figure 1 and Figure 2 according to IEC 60068-2-38.
The text of this International Standard is based on the following documents:
Draft Report on voting
86B/5264/FDIS 86B/5299/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all the parts of IEC 61300 series, under the general title, Fibre optic interconnecting
devices and passive components - Basic test and measurement procedures, can be found on
the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
1 Scope
This part of IEC 61300 defines the resistance of a fibre optic device or component to the
deteriorative effects of high temperature, humidity and cold conditions.
It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to
absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and
fissures as well as condensation. However, the degree of condensation will vary depending on
the size and thermal mass of the DUT.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60068-2-38, Environmental testing – Part 2-38: Tests – Test Z/AD: Composite
temperature/humidity cyclic test
IEC 61300-1, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 1: General and guidance
IEC 61300-3-1, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 61300-3-3, Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of
changes in attenuation and return loss
IEC 61300-3-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-4: Examinations and measurements – Attenuation
IEC 61753 (all parts), Fibre optic interconnecting devices and passive components -
Performance standards
IEC 62005 (all parts), Fibre optic interconnecting devices and passive components - Reliability
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61300-1 apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
– IEC Electropedia: available at https://www.electropedia.org/
– ISO Online browsing platform: available at https://www.iso.org/obp
4 General
This procedure is conducted in accordance with IEC 60068-2-38, test Z/AD. The DUT is placed
in a humidity chamber and subjected to 10 temperature-humidity cycles, each of 24 h duration.
During any five of the first nine cycles after exposure to the humidity subcycle, the DUT shall
be subjected to cold.
This test differs from other cyclic damp heat tests in that it derives its increased severity from:
a) a greater number of temperature variations leading to pumping actions in a given time;
b) a greater cyclic temperature range;
c) a higher rate of change of temperature;
d) the inclusion of a number of excursions to sub-zero temperature.
This type of test is particularly important for fibre optic devices or components made of a variety
of different materials.
5 Apparatus
5.1 General
The exposure to moisture humidity, followed by cold, can either be performed in one chamber
(see 5.4) or in two separate chambers (see 5.2 and 5.3).
5.2 Chamber for the exposure to moisture high temperature and humidity
The chamber for the exposure to moisture high temperature and humidity shall be so
constructed that:
a) the temperature can be varied between 25 °C ± 2 °C and 65 °C ± 2 °C in a period
between 1 h 30 min and 2 h 30 min for both rising and falling temperatures;
b) the relative humidity can be maintained at 93 % RH ± 3 % RH during the periods of constant
or rising temperature and between 88 % RH ± 8 % RH during the falling temperature
periods;
c) Care shall be taken to ensure that the conditions prevailing at any point in the working space
are uniform and are as similar as possible to those prevailing in the immediate vicinity of
suitably located temperature and humidity sensing devices;
d) the air in the chamber shall be continuously stirred at a rate necessary to maintain the
specified conditions of temperature and humidity;
e) the DUT shall not be subjected to radiant heat from the chamber conditioning processes ;
f) condensed water is continuously drained from the chamber and not used again until it has
been repurified;
g) Precautions shall be taken to ensure that no condensed water from the walls and roof of the
test chamber can fall on the DUT.
5.3 Chamber for exposure to cold
The chamber for exposure to cold shall be so constructed that:
a) the temperature can be maintained at –10 °C ± 2 °C for a period of 3 h;
b) Care shall be taken to ensure that the conditions prevailing at any point in the working space
are uniform and are as similar as possible to those prevailing in the immediate vicinity of
suitably located temperature sensing devices;
c) the air in the chamber shall be continuously stirred;
d) Care shall be taken that the thermal capacity of the DUT does not appreciably influence
conditions within the chamber.
5.4 Temperature and humidity chamber
5.4.1 General
The temperature and humidity chamber may be used for exposure to cold in which case it shall
meet the requirements of 5.2 and in addition shall be so constructed that:
a) the temperature can be lowered from 25 °C ± 2 °C to –10 °C ± 2 °C in a period of not more
than 30 min;
b) the DUT can be held at a temperature of –10 °C ± 2 °C for a period of 3 h;
c) the temperature can be raised from –10 °C ± 2 °C to 25 °C ± 2 °C in a period of not more
than 90 min.
5.4.2 Optical source and detector measurement equipment
The optical source and detector used to measure changes in for monitoring the attenuation and
return loss shall comply with those specified in IEC 61300-3-4 IEC 61300-3-3.
6 Procedure
6.1 Preparation of specimens DUT
Prepare the specimen according to the manufacturer’s instructions or as specified in the
relevant specification. The specimen shall be terminated with a sufficient length of fibre cable
to facilitate connection with the optical source and the detector.
The DUT shall be prepared in accordance with IEC 61300-1. The DUT shall be connected to
the optical source and to the detector.
Clean the optical and mechanical parts of the DUT according to the manufacturer’s instructions.
6.2 Preconditioning
Unless otherwise specified in the relevant specification, the DUT, switched off, ready for-use-
state, shall be subjected to 55 °C ± 2 °C with a relative humidity not exceeding 20 % RH for a
period of 24 h prior to the conditioning (see Figure 1).
The DUT shall then be allowed to attain thermal stability at standard atmospheric conditions for
testing or as otherwise specified in the relevant specification before the initial measurements
are made.
Figure 1 – Preconditioning
6.3 Initial examinations and measurements
The DUT shall be visually inspected and optically measured and mechanically checked as
required by the relevant specification.
Initial examinations and measurements shall be performed in accordance with the relevant
IEC 61753 performance standard or IEC 62005 reliability document. The initial visual
examination shall be performed on the DUT in accordance with IEC 61300-3-1. The optical
performance measurements shall be performed at the wavelength(s) specified in the relevant
IEC 61753 performance standard or IEC 62005 reliability document.
6.4 Conditioning
6.4.1 General
The DUT shall be introduced into the temperature and humidity chamber, switched off, ready-
for-use state, and shall fulfil its normal optical function, and shall be mounted in the normal
orientation (if known), or as otherwise specified in the relevant specification. The DUT shall
then be subjected to 10 temperature/ and humidity cycles, each of 24 h duration.
During any five of the first nine of the above-mentioned cycles, after exposure to the high
temperature and humidity subcycle (A-f to H in Figure 2), the DUT shall be subjected to cold
(see 6.4.2.2).
This exposure may be performed either in the same chamber or in separate chambers. If
separate chambers are used for the high temperature/high- and humidity and low-temperature
subcycles of the test, the DUT should not be subjected to thermal shock conditions unless it is
known that they are insensitive to this degree of thermal shock.
If a batch of DUT is subjected to thermal shock through the use of the two-chamber method and
significant failures occur, a further batch shall be retested with gradual change of temperatures
and shall be considered to have passed the test successfully if no significant failures occur
under these conditions.
The remaining four of the first nine cycles shall be run without exposure to cold (see 5.4.2.1.).
The specified high temperature and humidity cycles are the same in all cases.
6.4.2 Description of a 24 h cycle
6.4.2.1 Description of the high temperature and humidity subcycle
Applicable to all cycles (see Figure 2).
At “zero time” of every 24 h cycle, the chamber condition shall be controlled set to a temperature
of 25 °C ± 2 °C and relative humidity of 93 % RH ± 3 % RH.
a) The temperature of the chamber shall be steadily raised to 65 °C ± 2 °C over a period of
2 h ± 30 min. During this period, the relative humidity shall be maintained at
93 % RH ± 3 % RH.
b) The temperature and relative humidity in the chamber shall be maintained at 65 °C ± 2 °C
and 93 % RH ± 3 % RH respectively until 5 h 30 min after the start of the cycle.
c) The temperature shall then be allowed to fall to 25 °C ± 2 °C over a period of 2 h ± 30 min.
During this period, the relative humidity shall be maintained at 88 % RH ± 8 % RH.
d) Beginning 8 h after the start of the cycle, the temperature shall again be steadily raised to
65 °C ± 2 °C over a period of 2 h ± 30 min. During this period, the relative humidity shall be
maintained at 93 % RH ± 3 % RH.
e) The temperature and relative humidity in the chamber shall be maintained at
65 °C ± 2° C and 93 % RH ± 3 % RH respectively until 13 h 30 min after the start of the
cycle.
f) The temperature shall then be allowed to fall to 25 °C ± 2 °C over a period of 2 h ± 30 min.
During this period, the relative humidity in the chamber shall be maintained
at 88 % RH ± 8 % RH.
g) The chamber shall then continue to run at a stabilised temperature of 25 °C ± 2 °C and
relative humidity of 93 % RH ± 3 % RH until the start of the cold subcycle or until the end of
the 24 h cycle as appropriate.
6.4.2.2 Description of the cold subcycle
Applicable to any five of the first nine cycles (see Figure 2).
a) Following the completion of the high temperature and humidity subcycle (A-f to H in
Figure 2), the chamber is maintained at a temperature of 25 °C ± 2 °C and relative humidity
of 93 % RH ±3 % RH for a period of at least one 1,5 h but not more than 2,5 h.
b) 17 h 30 min after the start of the cycle, the DUT shall be exposed to a temperature of –
10 °C ± 2 °C. The ambient temperature of the chamber shall be reduced over a period of
not more than 30 min.
c) Beginning 18 h after the start of the cycle, the temperature shall be maintained at -
10 °C ± 2 °C for a period of 3 h.
d) No requirement for humidity is prescribed specified during the entire cold subcycle.
e) Beginning 21 h after the start of the cycle, the temperature shall be raised to 25 °C ± 2 °C.
This temperature shall be reached 22,5 h after the start of the cycle (see Figure 2).
f) If the DUT is transferred from one chamber to another, the transfer shall be completed within
a period of 10 min to 15 min.
g) The temperature of the chamber shall be maintained at 25 C ± 2 °C until the 24 h cycle is
completed.
h) During this period, the relative humidity shall be 93 % RH ± 3 % RH.
Relative humidity
uncontrolled
2 4 6 8 10 12 14 16 18 20 22 24 Time (h)
IEC 2407/09
a b c d e f g
* *
Preferred limit
1,5 1,5 1,5 1,5
Permissible limits
2,5 2,5 2,5 2,5
Preferred limit
Permissible limits
Time (h)
2 4 6 8 10 12 14 16 18 20 22 24
–10
IEC 2408/09
Figure 2 – Exposure humidity followed by exposure to cold
Temperature (°C) Relative humidity (%)
NOTE Relative humidity uncontrolled during the period between 17,5 h and 22,5 h. A to L are defined in
IEC 60068-2-38 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test.
Figure 2 – Exposure to high temperature and humidity followed by exposure to cold
6.4.2.3 Description of the 24 h cycles with no exposure to cold
Applicable to the remaining four of the first nine cycles.
Cycles which do not include a cold subcycle following the high temperature and humidity
subcycle are the same as described in 6.4.2.1, except that in item g) the chamber shall be
maintained at a temperature of 25 °C ± 2 °C and at a relative humidity of 93 % RH ± 3 % RH
until the 24 h cycle is completed.
6.4.2.4 Description of the final cycle
In the final cycle, following the completion of the high temperature and humidity subcycle, the
chamber is maintained at a temperature of 25 °C ± 2 °C and at a relative humidity
93 % RH ± 3 % RH for a period of 3 h 30 min after which the final measurements are made.
6.4.3 Examinations and measurements during the test
All examinations and measurements during the test (until completion of the final cycle) shall be
performed in accordance with the relevant IEC 61753 series performance standard or the
IEC 62005 series reliability document.
6.5 Recovery
After completion of the final cycle, the DUT shall be removed from the chamber and kept at
standard atmospheric conditions for at least 2 h in accordance with IEC 61300-1.
6.6 Final examinations and measurements
5.5.1 General
On completion of the test, remove all fixtures and make final measurements, as defined by the
relevant specification, to ensure that there is no permanent damage to the DUT. The results of
the final measurement shall be within the limit established in the relevant specification.
Optical and mechanical measurements shall be made:
a) immediately upon removal from the chamber, or
b) after a drying period,
as required by the relevant specification.
After conditioning, unless otherwise specified, visually examine the DUT in accordance with
IEC 61300-3-1.
Check for evidence of any degradation in the DUT. This may include, for example,
– broken, loose or damaged parts or accessories;
– breaking or damage to the cable sheath, seals, or strain relief;
– displaced, bent, or broken parts.
5.5.2 Immediately upon removal from the chamber
On completion of the final cycle, the DUT shall be removed from the chamber and be kept at
standard atmospheric conditions for testing.
If the initial measurements were made under conditions different from standard atmospheric
conditions for testin
...
IEC 61300-2-21 ®
Édition 3.0 2026-11
NORME
INTERNATIONALE
Dispositifs d'interconnexion et composants passifs fibroniques - Procédures
fondamentales d'essais et de mesures -
Partie 2-21: Essais - Essai cyclique composite de température et d'humidité
ICS 33.180.20 ISBN 978-2-8327-1608-3
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et
les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Recherche de publications IEC - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Découvrez notre puissant moteur de recherche et consultez
La recherche avancée permet de trouver des publications gratuitement tous les aperçus des publications, symboles
IEC en utilisant différents critères (numéro de référence, graphiques et le glossaire. Avec un abonnement, vous aurez
texte, comité d’études, …). Elle donne aussi des toujours accès à un contenu à jour adapté à vos besoins.
informations sur les projets et les publications remplacées
ou retirées. Electropedia - www.electropedia.org
Le premier dictionnaire d'électrotechnologie en ligne au
IEC Just Published - webstore.iec.ch/justpublished monde, avec plus de 22 500 articles terminologiques en
Restez informé sur les nouvelles publications IEC. Just anglais et en français, ainsi que les termes équivalents
dans 25 langues additionnelles. Egalement appelé
Published détaille les nouvelles publications parues.
Disponible en ligne et une fois par mois par email. Vocabulaire Electrotechnique International (IEV) en ligne.
Service Clients - webstore.iec.ch/csc
Si vous désirez nous donner des commentaires sur cette
publication ou si vous avez des questions contactez-
nous: sales@iec.ch.
SOMMAIRE
AVANT-PROPOS . 2
1 Domaine d’application . 4
2 Références normatives . 4
3 Termes et définitions . 4
4 Généralités . 4
5 Appareillage . 5
5.1 Généralités . 5
5.2 Enceinte d’exposition à des niveaux élevés de température et d’humidité . 5
5.3 Enceinte d’exposition au froid . 5
5.4 Enceinte de température et d’humidité . 6
5.4.1 Généralités . 6
5.4.2 Équipement de mesurage optique . 6
6 Mode opératoire . 6
6.1 Préparation du DUT . 6
6.2 Préconditionnement . 6
6.3 Examens et mesurages initiaux . 7
6.4 Conditionnement . 8
6.4.1 Généralités . 8
6.4.2 Description du cycle de 24 h . 8
6.4.3 Examens et mesurages pendant l’essai . 11
6.5 Récupération . 11
6.6 Examens et mesurages finaux . 11
7 Sévérité . 11
8 Détails à spécifier et à consigner dans le rapport d’essai . 12
Bibliographie . 13
Figure 1 – Préconditionnement . 7
Figure 2 – Exposition à des niveaux de température et d’humidité élevés suivie
d’une exposition au froid . 10
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
Dispositifs d’interconnexion et composants passifs fibroniques -
Procédures fondamentales d’essais et de mesures -
Partie 2-21: Essais - Essai cyclique composite
de température et d’humidité
AVANT-PROPOS
1) La Commission Électrotechnique Internationale (IEC) est une organisation mondiale de normalisation composée
de l’ensemble des comités électrotechniques nationaux (Comités nationaux de l’IEC). L’IEC a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l’électricité et de l’électronique. À cet effet, l’IEC – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de l’IEC"). Leur élaboration est confiée à des comités d’études, aux
travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec l’IEC, participent également aux
travaux. L’IEC collabore étroitement avec l’Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de l’IEC concernant les questions techniques représentent, dans la mesure du
possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de l’IEC intéressés
sont représentés dans chaque comité d’études.
3) Les Publications de l’IEC se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de l’IEC. Tous les efforts raisonnables sont entrepris afin que l’IEC
s’assure de l’exactitude du contenu technique de ses publications; l’IEC ne peut pas être tenue responsable de
l’éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d’encourager l’uniformité internationale, les Comités nationaux de l’IEC s’engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de l’IEC dans leurs publications nationales
et régionales. Toutes divergences entre toutes Publications de l’IEC et toutes publications nationales ou
régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) L’IEC elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d’évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de l’IEC. L’IEC n’est responsable d’aucun des services effectués par les organismes de certification
indépendants.
6) Tous les utilisateurs doivent s’assurer qu’ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à l’IEC, à ses administrateurs, employés, auxiliaires ou mandataires,
y compris ses experts particuliers et les membres de ses comités d’études et des Comités nationaux de l’IEC,
pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque
nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les dépenses
découlant de la publication ou de l’utilisation de cette Publication de l’IEC ou de toute a utre Publication de l’IEC,
ou au crédit qui lui est accordé.
8) L’attention est attirée sur les références normatives citées dans cette publication. L’utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’IEC attire l’attention sur le fait que la mise en application du présent document peut entraîner l’utilisation d’un
ou de plusieurs brevets. L’IEC ne prend pas position quant à la preuve, à la validité et à l’applicabilité de tout
droit de brevet revendiqué à cet égard. À la date de publication du présent document, l’IEC n’avait pas reçu
notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa mise en application. Toutefois, il y a lieu
d’avertir les responsables de la mise en application du présent document que des informations plus récentes
sont susceptibles de figurer dans la base de données de brevets, disponible à l’adresse https://pa tents.iec.ch.
L’IEC ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de propriété et averti de leur
existence.
L’IEC 61300-2-21 a été établie par le sous-comité 86B: Dispositifs d’interconnexion et
composants passifs à fibres optiques, du comité d’études 86 de l’IEC: Fibres optiques. Il s’agit
d’une Norme internationale.
Cette troisième édition annule et remplace la deuxième édition parue en 2009. Cette édition
constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l’édition
précédente:
a) mise à jour des termes et définitions et des caractéristiques détaillées à spécifier et à
consigner dans le rapport d’essai;
b) mise à jour des Figures 1 et 2 conformément à l’IEC 60068-2-38.
Le texte de cette Norme internationale est issu des documents suivants:
Projet Rapport de vote
86B/5264/FDIS 86B/5299/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à son approbation.
La langue employée pour l’élaboration de cette Norme internationale est l’anglais.
Ce document a été rédigé selon les Directives ISO/IEC, Partie 2, il a été développé selon les
Directives ISO/IEC, Partie 1 et les Directives ISO/IEC, Supplément IEC, disponibles sous
www.iec.ch/members_experts/refdocs. Les principaux types de documents développés par
l’IEC sont décrits plus en détail sous www.iec.ch/publications.
Une liste de toutes les parties de la série IEC 61300, publiées sous le titre général, Dispositifs
d’interconnexion et composants passifs fibroniques - Procédures fondamentales d’essais et de
mesures, se trouve sur le site web de l’IEC.
Le comité a décidé que le contenu de ce document ne sera pas modifié avant la date de stabilité
indiquée sur le site web de l’IEC sous webstore.iec.ch dans les données relatives au document
recherché. À cette date, le document sera:
– reconduit,
– supprimé, ou
– révisé.
1 Domaine d’application
L’objet de la présente partie de l’IEC 61300 est de déterminer la résistance d’un dispositif ou
composant fibronique aux effets de détérioration dus à des conditions de température élevée,
d’humidité et de froid.
Elle est destinée à révéler les défauts d’un dispositif soumis à essai (DUT, Device under test)
provoqués par le "pompage", phénomène distinct de l’absorption d’humidité. Cet essai couvre
l’effet de la congélation de l’eau piégée dans des craquelures et fissures et celui de la
condensation. Le niveau de condensation varie toutefois en fonction des dimensions et de la
masse thermique du DUT.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie
de leur contenu, des exigences du présent document. Pour les références datées, seule
l’édition citée s’applique. Pour les références non datées, la dernière é dition du document de
référence s’applique (y compris les éventuels amendements).
IEC 61300-1, Dispositifs d’interconnexion et composants passifs fibroniques - Procédures
fondamentales d’essais et de mesures - Partie 1: Généralités et recommandations
IEC 61300-3-1, Dispositifs d’interconnexion et composants passifs à fibres optiques - Méthodes
fondamentales d’essais et de mesures - Partie 3-1: Examens et mesures - Examen visuel
IEC 61300-3-3, Dispositifs d’interconnexion et composants passifs fibroniques - Méthodes
fondamentales d’essais et de mesures - Partie 3-3: Examens et mesures - Contrôle actif des
variations de l’affaiblissement et de l’affaiblissement de réflexion
IEC 61753 (toutes les parties), Dispositifs d’interconnexion et composants passifs fibroniques -
Norme de performance
IEC 62005 (toutes les part
...