Household and similar electrical appliances - Safety - Part 2-10: Particular requirements for floor treatment machines and wet scrubbing machines

Deals with the safety of electric floor treatment and wet scrubbing machines intended for household and similar purposes, their rated voltage being not more than 250 V. Examples of floor treatment machines are floor buffers, polishers and waxers. Examples of wet scrubbing machines are floor scrubbers, rug shampooers and upholstry shampooers. This consolidated version consists of the fifth edition (2002) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.

Appareils électrodomestiques et analogues - Sécurité - Partie 2-10: Règles particulières pour les appareils de traitement des sols et les machines à brosser les sols mouillés

Traite de la sécurité des appareils électriques de traitement des sols et des machines électriques à brosser les sols mouillés, pour usages domestiques et analogues, dont la tension assignée n'est pas supérieure à 250 V. Comme exemples d'appareils de traitement des sols, on peut citer les lustreuses; les polisseuses; et les cireuses. Comme exemples de machines à brosser les sols mouillés, on peut citer les machines à lessiver les sols; les machines à laver les tapis;et les machines à laver les tapisseries.  Cette version consolidée comprend la cinquième édition (2002) et son amendement 1 (2008). Il n'est donc pas nécessaire de commander l'amendement avec cette publication.

General Information

Status
Published
Publication Date
14-Jul-2008
Current Stage
DELPUB - Deleted Publication
Completion Date
14-Dec-2021
Ref Project

Buy Standard

Standard
IEC 60335-2-10:2002+AMD1:2008 CSV - Household and similar electrical appliances - Safety - Part 2-10: Particular requirements for floor treatment machines and wet scrubbing machines
English and French language
24 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 60335-2-10
Edition 5.1 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-10: Particular requirements for floor treatment machines and wet
scrubbing machines

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-10: Règles particulières pour les appareils de traitement des sols et les
machines à brosser les sols mouillés

IEC 60335-2-10:2002+A1:2008

---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2008 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch

About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00


A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00

---------------------- Page: 2 ----------------------
IEC 60335-2-10
Edition 5.1 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-10: Particular requirements for floor treatment machines and wet
scrubbing machines

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-10: Règles particulières pour les appareils de traitement des sols et les
machines à brosser les sols mouillés

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CD
CODE PRIX
ICS 13.120; 97.080 ISBN 2-8318-9751-3
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 3 ----------------------
– 2 – 60335-2-10 © IEC:2002+A1:2008
CONTENTS
FOREWORD.3
INTRODUCTION.5

1 Scope.6
2 Normative references .7
3 Definitions .7
4 General requirement.7
5 General conditions for the tests .7
6 Classification.7
7 Marking and instructions.8
8 Protection against access to live parts.8
9 Starting of motor-operated appliances .8
10 Power input and current .8
11 Heating .8
12 Void.8
13 Leakage current and electric strength at operating temperature.8
14 Transient overvoltages .8
15 Moisture resistance .9
16 Leakage current and electric strength.9
17 Overload protection of transformers and associated circuits .9
18 Endurance.9
19 Abnormal operation .9
20 Stability and mechanical hazards .9
21 Mechanical strength .10
22 Construction .10
23 Internal wiring.10
24 Components .10
25 Supply connection and external flexible cords .10
26 Terminals for external conductors.10
27 Provision for earthing .11
28 Screws and connections .11
29 Clearances, creepage distances and solid insulation .11
30 Resistance to heat and fire.11
31 Resistance to rusting.11
32 Radiation, toxicity and similar hazards.11

Annexes .12

Bibliography.12

---------------------- Page: 4 ----------------------
60335-2-10 © IEC:2002+A1:2008 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –

Part 2-10: Particular requirements for floor treatment machines
and wet scrubbing machines



FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by IEC technical committee 61:
Safety of household and similar electrical appliances.
This consolidated version of IEC 60335-2-10 consists of the fifth edition (2002) [documents
61/2201/FDIS and 61/2282/RVD] and its amendment 1 (2008) [documents 61/3540/FDIS and
61/3594/RVD].
The technical content is therefore identical to the base edition and its amendment and has
been prepared for user convenience.
It bears the edition number 5.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1.

---------------------- Page: 5 ----------------------
– 4 – 60335-2-10 © IEC:2002+A1:2008
The French version of this standard has not been voted upon.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for electric floor treatment
machines and wet scrubbing machines.
When a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. When this standard states “addition”, “modification” or “replacement”,
the relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.

NOTE 3 The following print types are used:
– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold.
The following differences exist in the countries indicated below.
– 3.1.9: Floor treatment machines are operated on a polished composition tile surface. Upholstery shampooers
are operated under load (USA).
– 6.1: Appliances for household use shall be class II or class III (Sweden).
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date,
the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

NOTE 4 The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of the amendment 1 be adopted for implementation
nationally not earlier than 12 months or later than 36 months from the date of publication.

---------------------- Page: 6 ----------------------
60335-2-10 © IEC:2002+A1:2008 – 5 –
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in
normal use taking into account the manufacturer's instructions. It also covers abnormal
situations that can be expected in practice and takes into account the way in which
electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply
mains. However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
When a part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 2 Horizontal and generic standards covering a hazard are not applicable since they have been taken into
consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as
ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features that impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of
the requirements and, if found to be substantially equivalent, may be considered to comply
with the standard.

---------------------- Page: 7 ----------------------
– 6 – 60335-2-10 © IEC:2002+A1:2008
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –

Part 2-10: Particular requirements for floor treatment machines
and wet scrubbing machines



1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric floor treatment and wet scrubbing
machines intended for household and similar purposes, their rated voltage being not more
than 250 V.
NOTE 101 Examples of floor treatment machines are
– floor buffers;
– floor polishers;
– floor waxers.
NOTE 102 Examples of wet scrubbing machines are
– floor scrubbers;
– rug shampooers;
– upholstery shampooers.
Appliances not intended for normal household use but that nevertheless may be a source of
danger to the public, such as appliances intended to be used by laymen in shops, in light
industry and on farms, are within the scope of this standard.
NOTE 103 Examples of such appliances are appliances intended to be used in hotels, offices, schools, hospitals
and similar premises.
As far as is practicable, this standard deals with the common hazards presented by
appliances that are encountered by all persons in and around the home. However, in general,
it does not take into account
– persons (including children) whose
• physical, sensory or mental capabilities; or
• lack of experience and knowledge
prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
NOTE 104 Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be
necessary;
– in many countries additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour and similar authorities.
NOTE 105 This standard does not apply to
– vacuum cleaners and water suction cleaning appliances (IEC 60335-2-2);
– appliances intended for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour, or gas);
– floor sanding machines.

---------------------- Page: 8 ----------------------
60335-2-10 © IEC:2002+A1:2008 – 7 –
2 Normative references
This clause of Part 1 is applicable.
3 Definitions
This clause of Part 1 is applicable except as follows.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions
Floor treatment machines are operated while being moved backwards and forwards at a rate
of 15 cycles per minute on a polished steel plate over a distance of 1 m. The appliance is
fitted with brushes for hard-surface floors in accordance with the instructions.
NOTE 101 Heating of the steel plate is to be prevented. Forced cooling may be used but care is to be taken to
ensure that the air movement does not affect the temperature rises to be determined.
Floor scrubbers are operated on untreated smooth pine-wood boards, 25 mm thick and
approximately 100 mm wide, fastened inside the bottom of a metal pan. The pan is filled with
water to a level approximately 1 mm above the surface of the boards.  The scrubber is moved
backwards and forwards at a rate of 10 cycles per minute over a distance of 1 m.
Rug shampooers are operated on a carpet that is fastened inside the bottom of a metal pan
that is filled with water to a level approximately 3 mm below the surface of the carpet. The
carpet is made of nylon fibres having a pile height of approximately 6 mm. The shampooer is
moved backwards and forwards at a rate of 10 cycles per minute over a distance of 1 m.
If the floor scrubber or rug shampooer has a liquid dispensing system, the pan is not filled
with water but the liquid dispensing system is in operation.
Upholstery shampooers are operated without their rotating brushes or similar devices being in
contact with upholstery or any other surface. Suction hoses are laid out straight with the inlet
unobstructed. Liquid dispensing systems are operated with the liquid container empty.
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable.
6 Classification
This clause of Part 1 is applicable.

---------------------- Page: 9 ----------------------
– 8 – 60335-2-10 © IEC:2002+A1:2008
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.12 Addition:
The instructions for appliances with rotating brushes shall state that a hazard may occur if the
appliance runs over the supply cord.
The instructions for appliances with a liquid dispensing system shall specify the amount and
type of the liquid to be used.
The instructions shall state that the plug must be removed from the socket-outlet before
cleaning or maintaining the appliance.
8 Protection against access to live parts
This clause of Part 1 is applicable.
9 Starting of motor-operated appliances
This clause of Part 1 is not applicable.
10 Power input and current
This clause of Part 1 is applicable.
11 Heating
This clause of Part 1 is applicable except as follows.
11.7 Replacement:
Appliances are operated until steady conditions are established.
Appliances incorporating an automatic cord reel are operated with one-third of the total length
of the cord unreeled for 30 min, after which the cord is completely unreeled.
12 Void
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable.
14 Transient overvoltages
This clause of Part 1 is applicable.

---------------------- Page: 10 ----------------------
60335-2-10 © IEC:2002+A1:2008 – 9 –
15 Moisture resistance
This clause of Part 1 is applicable except as follows.
15.2 Modification:
Wet scrubbing machines are filled with a detergent solution specified in the instructions
instead of the saline solution.
Addition:
Wet scrubbing machines are supplied at rated voltage and operated for 10 min under
normal operation except that
– the rate of movement is 15 cycles per minute;
– the water level is
• approximately 1 mm below the surface of the carpet for rug shampooers;
• approximately 5 mm above the surface of the wooden boards for floor scrubbers.
16 Leakage current and electric strength
This clause of Part 1 is applicable.
17 Overload protection of transformers and associated circuits
This clause of Part 1 is applicable.
18 Endurance
This clause of Part 1 is not applicable.
19 Abnormal operation
This clause of Part 1 is applicable except as follows.
19.7 Addition:
Appliances are operated for 30 s.
19.10 Addition:
NOTE 101 Appliances are operated without the brushes in contact with any surface.
20 Stability and mechanical hazards
This clause of Part 1 is applicable except as follows.
20.1 Addition:
NOTE 101 This requirement only applies to parts of appliances incorporating a liquid container.

---------------------- Page: 11 ----------------------
– 10 – 60335-2-10 © IEC:2002+A1:2008
20.2 Addition:
NOTE 101 The requirement regarding moving parts does not apply to brushes and similar devices. It does not
apply to moving parts such as shafts that become accessible when changing accessories and that only move when
the brush or similar device is moving.
21 Mechanical strength
This clause of Part 1 is applicable.
22 Construction
This clause of Part 1 is applicable except as follows.
22.101 Appliances with single-disc brushes and having a rated power input exceeding
300 W shall incorporate means to prevent starting in addition to the switch.
Other appliances shall be constructed so that inadvertent operation is unlikely.
Compliance is checked by inspection, by manual test and by the following test.
The means to prevent starting is operated 6 000 times. It shall then be fit for further use and
shall not be damaged to such an extent that compliance with this standard is impaired.
NOTE 1 The means to prevent starting is considered to be met by incorporating a biased off-switch that
– incorporates a self-resetting interlock, or
– is used in combination with an additional device that prevents
• the appliance from being operated, or
• the brush from being engaged with the motor when the handle is in the storage position.
NOTE 2 Inadvertent operation is considered to be unlikely if the actuating member of the switch is appropriately
located, for example in a recess.
23 Internal wiring
This clause of Part 1 is applicable.
24 Components
This clause of Part 1 is applicable.
25 Supply connection and external flexible cords
This clause of Part 1 is applicable.
26 Terminals for external conductors
This clause of Part 1 is applicable.

---------------------- Page: 12 ----------------------
60335-2-10 © IEC:2002+A1:2008 – 11 –
27 Provision for earthing
This clause of Part 1 is applicable.
28 Screws and connections
This clause of Part 1 is applicable.
29 Clearances, creepage distances and solid insulation
This clause of Part 1 is applicable except as follows.
29.2 Addition:
The microenvironment is pollution degree 3 unless the insulation is enclosed or located so
that it is unlikely to be exposed to pollution during normal use of the appliance.
30 Resistance to heat and fire
This clause of Part 1 is applicable except as follows.
30.2.3 Not applicable.
31 Resistance to rusting
This clause of Part 1 is applicable.
32 Radiation, toxicity and similar hazards
This clause of Part 1 is applicable.

---------------------- Page: 13 ----------------------
– 12 – 60335-2-10 © IEC:2002+A1:2008
Annexes
The annexes of Part 1 are applicable except as follows.

Annex C
(normative)

Aging test on motors
Modification:
The value of p in Tabl
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.