INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
IEC 60079-0
Edition 6.0  2011-06
EXPLOSIVE ATMOSPHERES –
Part 0: Equipment – General requirements

INTERPRETATION SHEET 3
This interpretation sheet has been prepared by IEC technical committee 31: Equipment for
explosive atmospheres.
The text of this interpretation sheet is based on the following documents:
FDIS Report on voting
31/1376/FDIS 31/1386/RVD
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.

___________
Question:
How shall marking be shown for equipment covered by both the electrical and non-electrical
standards (IEC 60079 and ISO 80079 series)?
Answer:
Equipment which includes both an electrical part and a non-electrical part shall have
combined marking. For example:
Ex db h IIA T4 Gb
Ex h tb IIIC T135 °C Db
It will be clearer for the user that the combined risk of the electrical part and the non-electrical
part, covered by a single certificate, has been assessed for the complete equipment, stating
one EPL, one equipment Group and one temperature class for Gas and the same for Dust
(but showing a maximum surface temperature instead of a temperature class). It is also noted
that Ex Components are not marked with either a temperature class (Group II) or a maximum
surface temperature (Group III).
ICS 29.260.20
IEC 60079-0:2011-06/ISH3:2018-06(en-fr)

– 2 – IEC 60079-0:2011/ISH3:2018  IEC 2018

For equipment where separate certificates have been prepared, with one for the electrical

parts, and one for the non-electrical parts, it is appropriate to have separate electrical and

non-electrical marking strings, each with its own associated certificate number.

NOTE Additional guidance on the marking of assemblies is given in IEC TS 60079-46.

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.