IEC TS 60034-17:2002/COR1:2002
(Corrigendum)Corrigendum 1 - Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
Corrigendum 1 - Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
Corrigendum 1 - Machines électriques tournantes - Partie 17: Moteurs à induction à cage alimentés par convertisseurs - Guide d'application
General Information
Relations
Standards Content (Sample)
CEI TS 60034-17 IEC TS 60034-17
(Troisième édition – 2002) (Third edition – 2002)
Machines électriques tournantes – Rotating electrical machines –
Partie 17: Moteurs à induction à cage alimentés Part 17: Cage induction motors when fed from
par convertisseurs – Guide d'application converters – Application guide
CORRIGENDUM 1
Page 22 Page 23
Deuxième alinéa Second paragraph
Remplacer la première phrase par Replace the first sentence by
ce qui suit: the following:
S'il est prévu de mesurer l
...
This May Also Interest You
Specifies four standard designs of starting performance of single speed three-phase cage induction motors for direct on-line or star-delta starting and rated on the basis of duty-type S-1 (maximum continuous rating). Also covers dual voltage motors in so far as the flux saturation level is the same for both voltages.
- Standard21 pagesEnglish and French languagesale 15% off
- Standard24 pagesEnglish and French languagesale 15% off
This technical specification deals with the steady-state operation of cage induction motors within the scope of IEC 60034-12, when fed from converters. It covers the operation over the whole speed setting range, but does not deal with starting or transient phenomena. Only indirect type converters are dealt with. This type comprises converters with impressed direct current in the intermediate circuit (current source converters) and converters with impressed d.c. voltage (voltage source converters), either of the block type or the pulse controlled type, without restriction on pulse number, pulse width or pulse frequency.
- Technical specification35 pagesEnglish and French languagesale 15% off
Gives the requirements for rotating control motors and describes the appropriate tests. Also gives dimensions and marking information and the details to be provided by the manufacturer in associated data sheets and catalogues. Applicable to rotating stepping motors only.
- Technical specification71 pagesEnglish and French languagesale 15% off
- Technical specification29 pagesEnglish and French languagesale 15% off
IEC 61800-9-2:2023 specifies energy efficiency indicators of power electronics (complete drive modules (CDM), input or output sub drive modules (SDM), power drive systems (PDS) and motor starters, all used for motor driven equipment.
This document is a group energy efficiency publication according to IEC Guide 119 and specifies the methodology for the determination of losses of the complete drive module (CDM), the sub drive module (SDM), the power drive system (PDS) and the motor system.
It defines IE and IES classes, their limit values and provides test procedures for the classification of the overall losses of the motor system.
Furthermore, this document proposes a methodology for the implementation of the best energy efficiency solution of drive systems. This depends on the architecture of the motor driven system, on the speed/torque profile and on the operating points over time of the driven load equipment. It provides a link for the energy efficiency evaluation and classification of the extended product.
This edition includes the following significant technical changes with respect to the previous edition:
a) Additional IES Classes defined to IES5;
b) Removed reference motor loss data and now point to IEC 60034-30-2;
c) Expanded and modified factors in Clause 6 for CDMs;
d) Annex C is now the Mathematical Model for CDM Losses;
e) Moved the mathematical model for the CDM to Annex C;
f) Added Sub Drive Input Module and Sub Drive Output Modules to Annex B;
g) Annex D is now the Converter Topology (old Annex C);
h) Annex E is now the Interpolation of Motor Losses (Old Annex D);
i) Annex E expanded to include various motor connections and updated interpolation method;
j) New Annex E for determination of Interpolation Coefficients;
k) Annex F is the old Annex E;
l) New Annex J Explanation of Correction Factors for the Reference Losses in Table 8.
- Standard276 pagesEnglish and French languagesale 15% off
IEC 61800-2:2021 applies to adjustable speed electric AC power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the AC motors.
It applies to adjustable speed electric power drive systems intended to feed AC motors from a BDM or CDM connected to line-to-line voltages up to and including 35 kV AC 50 Hz or 60 Hz and/or voltages up to and including 1,5 kV DC input side.
NOTE Adjustable speed electric DC power drive systems intended to feed DC motors are covered by IEC 61800-1.
This documents defines and describes a non-exhaustive list of criteria for the selection of BDM/CDM/PDS performance and functional attributes. This list is reviewed by the responsible parties to determine considerations for the design of device(s), equipment or system(s) with related testing specification. It also suggests a selection of performance and functional attributes for driven equipment and extended products. The performance and functional attributes focus on the following categories:
principal parts topology and classification of the PDS;
ratings, performance and functionality;
specifications for the environment in which the PDS is intended to be installed and operated;
other specifications which might be applicable when specifying a complete PDS. Traction applications and electric vehicles are excluded from the scope of this document.
This document provides a non-exhaustive list from which minimum requirements can be used for the development of a specification between customer and manufacturer based on the application requirements. This same non-exhaustive list can be used by a manufacturer to determine the minimum requirements for a commoditised BDM/CDM/PDS without customer interaction based on the specified application of that BDM/CDM/PDS.
This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a. the requirements from IEC 61800-4 for high-voltage PDS are now merged with requirements from IEC 61800-2:2015;
b. Clause 1 has been updated to introduce the new concept of Clause 4;
c. terms and definitions in Table 1 to Table 4 have been classified in logical order; classification in low voltage and high voltage has been considered in Table 5, and Figure 3 clarifies boundaries within BDM/CDM/PDS.
d. Clause 4 is new and creates the methods for evaluating a product to this document;
e. Clause 5 has been updated with respect to:
specific content for high-voltage BDM/CDM/PDS;
description of the basic topology for BDM/CDM/PDS (5.2);
ratings and performance (5.3 and 5.4);
reference to applicable standards within the IEC 61800 series with respect to EMC (IEC 61800-3), electrical safety (IEC 61800-5-1), functional safety (IEC 61800-5-2), load duty aspects (IEC TR 61800-6), communication profiles (IEC 61800-7 series), power interface voltage (IEC TS 61800-8), and ecodesign (IEC 61800-9 series) to avoid conflicting requirements (5.5, 5.6, 5.7, 5.10, 5.11, 5.12);
update of requirement for ecodesign (5.8);
update of requirement for environmental evaluation (5.9);
implementation of requirement for explosive atmosphere (5.14); f) Clause REF _Ref51162898 \w \h 6 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000D0000005F00520065006600350031003100360032003800390038000000 has been updated with test requirement in order to provide a clear link between design requirement and test requirement;
g) Clause REF _Ref336520009 \w \h 7 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003300330036003500320030003000300039000000 has been updated to harmonize the marking and documentation requirement within IEC 61800 (all parts);
h) existing REF _Ref51162926 \w \h Annex A 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000D0000005F0052006500660035003100310036003200390032003
- Standard233 pagesEnglish and French languagesale 15% off
IEC 61800-1:2021 applies to adjustable speed electric DC power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the DC motors.
It applies to adjustable speed electric power drive systems intended to feed DC motors from a BDM/CDM connected to line-to-line voltages up to and including 1 kV AC 50 Hz or 60 Hz and/or voltages up to and including 1,5 kV DC input side.
NOTE 1 Adjustable speed electric AC power drive systems intended to feed AC motors are covered by
IEC 61800-2.
NOTE 2 This document can be used as a reference for adjustable speed electric power drive systems, intended to feed DC motors from a BDM/CDM connected to line-to-line voltages up to and including 1,5 kV AC, 50 Hz or 60 Hz and/or voltages up to and including 2,25 kV DC input side.
This edition includes the following significant technical changes with respect to the previous edition:
a) the clause structure has been harmonized with IEC 61800-2;
b) Clause 2 has been updated;
c) Clause 3 has been updated including fundamental definitions to be used across IEC 61800 (all parts);
d) Clause 4 has been updated with respect to:
1) description of the basic topology for BDM/CDM/PDS (4.2);
2) ratings and performance (4.3 and 4.4);
3) reference to applicable standards within the IEC 61800 series with respect to EMC (IEC 61800-3), general safety (IEC 61800-5-1), functional safety (IEC 61800-5-2), load duty aspects (IEC TR 61800-6), communication profiles (IEC 61800-7 series),power interface voltage (IEC TS 61800-8), and ecodesign energy efficiency standards (IEC 61800-9) to avoid conflicting requirements (4.5, 4.6, 4.7, 4.10, 4.11, 4.12);
4) update of requirement for ecodesign (4.8);
5) update of requirement for environmental evaluation (4.9);
6) implementation of requirement for explosive atmosphere (4.13);
e) Clause 5 has been updated with test requirement in order to provide a clear link between design requirement and test requirement;
f) Clause 6 has been updated to harmonize the marking and documentation requirement within IEC 61800 (all parts);
g) the Annexes have been updated.
- Standard272 pagesEnglish and French languagesale 15% off
IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA).
This document specifies the methodology of determination of losses of the extended product and its sub-parts. It is applicable to motor systems operated by a motor starter or by a converter (power drive systems).
- Standard61 pagesEnglish and French languagesale 15% off
IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology for the determination of losses of the complete drive module (CDM), the power drive system (PDS) and the motor system.
It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system.
Furthermore, this document proposes a methodology for the implementation of the best energy efficiency solution of drive systems.
This depends on the architecture of the motor driven system, on the speed/load profile and on the operating points over time of the driven equipment.
- Standard226 pagesEnglish and French languagesale 15% off
IEC 60793-2-70: 2017 This part of IEC 60793 is applicable to optical fibre types D1, D2, D3, as described in REF _Ref459118742 \h \* MERGEFORMAT Table 1 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003400350039003100310038003700340032000000 . These fibres are polarization-maintaining fibre types, and are used or can be incorporated in information transmission equipment and optical fibre cable. These fibres are available for use in optical transport networks. Three types of requirements apply to these fibres:
- general requirements defined in IEC 60793-2;
- specific requirements common to the category D polarization-maintaining fibres covered in this document and which are given in Clause 4;
- particular requirements applicable to individual fibre types or specific applications, which are defined in Annexes A to C.
Table 1 – Categories of glass core/glass clad polarization-maintaining fibres
Category
Type
Description
D1
Polarization-maintaining fibre suitable for use at 980 nm
This category of polarization-maintaining fibre is optimised for polarization-maintaining ability in the 980 nm region. This fibre is used for erbium-doped fibre amplifier.
D2
Polarization-maintaining fibre suitable for use at 1 310 nm
This category of polarization-maintaining fibre is optimised for polarization-maintaining ability and connection property of category B fibres in the 1 310 nm region.
D3
Polarization-maintaining fibre suitable for use at 1 550 nm
This category of polarization-maintaining fibre is optimised for polarization-maintaining ability and connection property of category B fibres in the
1 550 nm region.
- Standard19 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion