Corrigendum 1 - Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.

Applies to portable voltage detectors with or without built-in power sources, to be used on electrical systems for voltages of 1 kV to 420 kV a.c. and frequencies from 15 Hz to 60 Hz. For the time being, it has been identified that : - For voltage levels up to 52 kV, the actual standard can be used in its entirety ; - For voltage levels above 52 kV, electric testing procedures are questionable from the point of view of their representativity and feasibility. For voltage detectors for use above 52 kV, manufacturers and customers should agree alternative electrical test arrangements, for example, electrical tests based on former national standards, until the publication of the second edition of this standard.

Corrigendum 1 - Travaux sous tension - Détecteurs de tension - Partie 1: Détecteurs de type capacitifs pour usage sur des tensions alternatives de plus de 1 kV

S'applique aux détecteurs de tension portatifs avec ou sans alimentation incorporée pour utilisation sur réseaux électriques de tension alternatives de 1 kV à 420 kV et de fréquences de 15 Hz à 60 Hz. Pour l'instant, il a été identifié que : La présente partie de la CEI 1243 est applicable aux détecteurs de tension portatifs avec ou sans alimentation incorporée pour - Pour des niveaux de tension jusqu'à 52 kV, la présente norme est utilisable intégralement ; utilisation sur réseaux électriques de tension alternatives de 1 kV - Pour des niveaux de tension excédant 52 kV, les procédures d'essais électriques sont discutables en ce qui a trait à leur représentativité et à leur faisabilité. à 420 kV et de fréquences de 15 Hz à 60 Hz. Dans les cas de détecteurs de tension pour utilisation à des tensions excédant 52 kV, il convient que clients et fabriquants s'entendent sur l'utilisation de montages alternatifs d'essais électriques, par exemple, des essais électriques basés sur les normes nationales antérieures, et cela jusqu'à la publication de la deuxième édition de la présente norme.

General Information

Status
Published
Publication Date
22-Jul-1999
Technical Committee
Current Stage
DELPUB - Deleted Publication
Completion Date
28-Oct-2003
Ref Project

Relations

Buy Standard

Standard
IEC 61243-1:1993/COR1:1999 - Corrigendum 1 - Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c. Released:7/23/1999
English and French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


Publication 61243-1 de la CEI IEC Publication 61243-1
(Première édition – 1993) (First edition – 1993)

Travaux sous tension – Détecteurs de tension – Live working – Voltage detectors –

Partie 1: Détecteurs de type capacitif Part 1: Capacitive type to be used

pour usage sur des tensions alternatives for voltages exceeding 1 kV a.c.
de plus de 1 kV
CORRIGENDUM 1
Le comité technique 78 est toujours attentif à Technical committee 78 continues to monitor the
l'emploi en travaux sous tension de matériaux et de use of chemicals and materials in live working that
produits chimiques qui, tout en étant adéquats, are suitable and provide for safety, occupational
assurent la santé et la sécurité au travail ainsi que health and environmental protection. As a result,
la protection de l'environnement. En conséquence, a suitable solvent has been found to replace the
un solvant adéquat a été identifié pour remplacer le previously used trichloro-1,1,2 trifluoro-1,2,2 ethane
trichloro-1,1,2 trifluoro-1,2,2 éthane (aussi connu (also known as trifluorotrichloroethane, Freon and
sous les appellations trifluorotrichloroéthane, Fréon Refrigerant 113). A part of this corrigendum was
et Réfrigérant 113), utilisé au préalable. Une partie prepared accordingly.
de ce corrigendum a été preparé sur cette base.
Page 6 Page 7
1 Domaine d’application 1 Scope
Ajouter, après le premier alinéa, le texte Add, after the first paragraph, the following
suivant: text:
Pour l’instant, il a été identifié que: For the time being, it has been identified
that:
– pour des niveaux de tension jusqu’à –for voltage levels up to 52 kV, the
52 kV, la présente norme est utilisable actual standard can be used in its
intégralement; entirety;
– pour des niveaux de tension excédant – for voltage levels above 52 kV, electric
52 kV, les procédures d’essais électriques testing procedures are questionable from
sont discutables en ce qui a trait à leur the point of view of their representativi
...