Fibre optic connector interfaces - Part 7:Type MPO connector family

Defines the standard interface dimensions for type MPO family of connectors which is a multiway plug connector characterized by a rectangular ferrule normally 6,4 mm x 2,5 mm.

General Information

Status
Published
Publication Date
27-Nov-2000
Current Stage
DELPUB - Deleted Publication
Completion Date
29-Nov-2004
Ref Project

Relations

Buy Standard

Standard
IEC 61754-7:1996 - Fibre optic connector interfaces - Part 7:Type MPO connector family Released:12/12/1996
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 61754-7:1996+AMD1:1999+AMD2:2000 CSV - Fibre optic connector interfaces - Part 7: Type MPO connector family Released:11/28/2000 Isbn:2831854210
English language
26 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL
IEC
STANDARD
1754-7
First edition
1996-12
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO

Reference number
IEC 1754-7: 1996 (E)
Validité de la présente publication Validity of this publication

Le contenu technique des publications de la CEI est cons- The technical content of IEC publications is kept under

tamment revu par la CEI afin qu'il reflète l'état actuel de constant review by the IEC, thus ensuring that the content

la technique. reflects current technology.

Des renseignements relatifs à la date de reconfirmation de Information relating to the date of the reconfirmation of the

la publication sont disponibles auprès du Bureau Central de publication is available from the IEC Central Office.

la CEI.
Les renseignements relatifs à ces révisions, à l'établis- Information on the revision work, the issue of revised
sement des éditions révisées et aux amendements peuvent editions and amendments may be obtained from IEC

être obtenus auprès des Comités nationaux de la CEI et National Committees and from the following IEC

dans les documents ci-dessous: sources:
• Bulletin de la CEI • IEC Bulletin
• Annuaire de la CEI • IEC Yearbook
Publié annuellement Published yearly
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
Terminologie Terminology
En ce qui concerne la terminologie générale, le lecteur se For general terminology, readers are referred to IEC 50:
reportera à la CEI 50: Vocabulaire Electrotechnique Inter- International Electrotechnical Vocabulary (IEV), which is
national (VEI), qui se présente sous forme de chapitres issued in the form of separate chapters each dealing
séparés traitant chacun d'un sujet défini. Des détails with a specific field. Full details of the IEV will be
complets sur le VEI peuvent être obtenus sur demande. supplied on request. See also the IEC Multilingual
Voir également le dictionnaire multilingue de la CEI. Dictionary.
Les termes et définitions figurant dans la présente publi- The terms and definitions contained in the present publi-
cation ont été soit tirés du VEI, soit spécifiquement cation have either been taken from the IEV or have been
approuvés aux fins de cette publication. specifically approved for the purpose of this publication.
Symboles graphiques et littéraux Graphical and letter symbols
Pour les symboles graphiques, les symboles littéraux et les For graphical symbols, and letter symbols and signs
signes d'usage général approuvés par la CEI, le lecteur approved by the IEC for general use, readers are referred to
consultera: publications:
– la CEI 27: Symboles littéraux à utiliser en – IEC 27: Letter symbols to be used in electrical
électro-technique; technology;
– la CEI 417: Symboles graphiques utilisables – IEC 417: Graphical symbols for use on
sur le matériel. Index, relevé et compilation des equipment. Index, survey and compilation of the
feuilles individuelles; single sheets;
– la CEI 617: Symboles graphiques pour schémas; – IEC 617: Graphical symbols for diagrams;

et pour les appareils électromédicaux, and for medical electrical equipment,
– la CEI 878: Symboles graphiques pour – IEC 878: Graphical symbols for electromedical
équipements électriques en pratique médicale. equipment in medical practice.
Les symboles et signes contenus dans la présente publi- The symbols and signs contained in the present publication
cation ont été soit tirés de la CEI 27, de la CEI 417, de la have either been taken from IEC 27, IEC 417, IEC 617
CEI 617 et/ou de la CEI 878, soit spécifiquement approuvés and/or IEC 878, or have been specifically approved for the
aux fins de cette publication. purpose of this publication.
Publications de la CEI établies par le IEC publications prepared by the same
même comité d'études technical committee
L'attention du lecteur est attirée sur les listes figurant à la fin The attention of readers is drawn to the end pages of this
de cette publication, qui énumèrent les publications de la publication which list the IEC publications issued by the
CEI préparées par le comité d'études qui a établi la technical committee which has prepared the present
présente publication. publication.

INTERNATIONAL
IEC
STANDARD
1754-7
First edition
1996-12
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO

 CEI 1996  Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized
utilisée sous quelque forme que ce soit et par aucun procédé, in any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission
microfilms, sans l'accord écrit de l'éditeur. in writing from the publisher
Bureau central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève Suisse
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE P
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 1754-7 © IEC:1996 (E)
CONTENTS
Page
FOREWORD . 3

Clause
1 Scope. 4

2 Description. 4
3 Interfaces. 4

1754-7 © IEC:1996 (E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7: Type MPO connector family

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 1754-7 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/836/FDIS 86B/926/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

– 4 – 1754-7 © IEC:1996 (E)
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7: Type MPO connector family

1 Scope
This part of IEC 1754 defines the standard interface dimensions for type MPO family of

connectors.
2 Description
The parent connector for type MPO connector family is a multiway plug connector charac-
terized by a rectangular ferrule normally 6,4 mm × 2,5 mm which utilizes two pins of 0,7 mm
diameter as its alignment. It is applicable to a joint of multiple fibres up to 12 fibres by arraying
them between two pin-positioning holes in the ferrule. The connector includes a push-pull
coupling mechanism and a ferrule spring loaded in the direction of the optical axis. The
connector has a single male key which may be used to orient and limit the relative position
between the connector and the component to which it is mated.
Connector interfaces are configured using a female plug without pins, a male plug with pins fixed
and an adaptor as shown in figure 1. The female plug is intermateable with the male plug.
Connector interfaces with different numbers of optical datum targets will intermate and will
correctly align the lower defined numbers of optical datum targets.
3 Interfaces
This standard contains the following standard interfaces.
Interface 7-1: MPO female plug connector angled interface – Push/pull
Interface 7-2: MPO male plug connector angled interface – Push/pull
Interface 7-3: MPO adaptor interface – Push/pull

1754-7 © IEC:1996 (E) – 5 –
Interface 7-1 Interface 7-3 Interface 7-2

Figure 1 – MPO connector configurations

– 6 – 1754-7 © IEC:1996 (E)
Figure 2a – MPO female plug connector angled interface

1754-7 © IEC:1996 (E) – 7 –
Table 1a – Dimensions of the MPO female plug connector angled interface

Reference Dimensions Notes
Minimum Maximum
A 0,699 mm 0,701 mm 1
B 7,9 mm 8,1 mm
C 4,597 mm 4,603 mm 2
D 6,3 mm 6,5 mm
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm
11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm 3
J 7,9 mm 8,1 mm
K 1,4 mm –
L 0,2 mm 0,8 mm 4 and 5
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42º 45º
AB – 45º
AC – 45º
AD 7,5º 8,5º
NOTES
1 Each pin-hole shall accept a gauge pin as shown in figure 2c to a depth of 5,5 mm with a maximum force of 1,7 N.
In addition, two pin-holes of a plug shall accept a gauge as shown in figure 2d to a depth of 5,5 mm with a
maximum force of 3,4 N.
2 Dimension C is defined as the distance between two pin-hole centres.
3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is
movable by a certain axial compression force, and therefore the dimension I is variable. Ferrule compression force
shall be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm.

4 Coupling sleeve shall be movable by a certain axial compression force. Dimension L is given for a coupling
sleeve end when not mated. Coupling sleeve compression force shall be 2,9 N to 6,9 N when a position of the
coupling sleeve endface from datum Z is in the range of 0 to 0,1 mm.
5 An adaptor coupling part shall be unlocked by a left-direction movement of a coupling sleeve, when it is separate
from an adaptor. When the coupling sleeve is moved for unlocking, a position of the coupling sleeve endface shall
be larger than 2,0 mm in the left direction from the datum Z.

– 8 – 1754-7 © IEC:1996 (E)
Figure 2b – Optical datum target location diagrams
NOTE – The optical datum target location diagram is shown in the figure. Here, datum X is defined as the line
passing through two pin-hole centres, and datum Y is defined as the line perpendicular to datum X and passing
through the midpoint of two pin-hole centres.

1754-7 © IEC:1996 (E) – 9 –
Figure 2c – Gauge pin
Table 1b – Dimensions of the gauge pin
Dimensions
Reference mm Notes
Minimum Maximum
A 0,6985 0,6990 1
B 10,8 11,2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 –
NOTES
1  Surface roughness R = 0,1 μm for the length of dimension BC.
z
2  Typical dimensions.
– 10 – 1754-7 © IEC:1996 (E)
Figure 2d – Gauge for plug
Table 1c – Dimensions of the gauge for plug
Dimensions
Reference mm Notes
Minimum Maximum
A 0,6985 0,6990 for two pins, 1
C 4,5995 4,6005
D 6,3 6,5 2
U 2,4 2,5 2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 6,5
NOTES
1 Surface roughness R = 0,1 μm.
z
2 Typical dimensions.
1754-7 © IEC:1996 (E) – 11 –
Figure 3a – MPO male plug connector angled interface

– 12 – 1754-7 © IEC:1996 (E)
Table 2a – Dimensions of the MPO male plug connector angled interface

Reference Dimensions Notes
Minimum Maximum
A 0,699 mm 0,701 mm 1
B 7,9 mm 8,1 mm
C 4,597 mm 4,603 mm 2
D 6,3 mm 6,5 mm
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
8,8 mm 9,2 mm 3
I
8,1 mm
J 7,9 mm

K 1,4 mm
4 and 5
L 0,2 mm 0,8 mm
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42º 45º
AB – 45º
AC – 45º
AD 7,5º 8,5º
CA
...


NORME IEC
INTERNATIONALE 61754-7
Edition 1.2
2000-11
Edition 1:1996 consolidated with amendments 1:1999 and 2:2000
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO

Reference number
Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in

the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.

Consolidated editions
The IEC is now publishing consolidated versions of its publications. For

example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base

publication, the base publication incorporating amendment 1 and the base
publication incorporating amendments 1 and 2.

Further information on IEC publications

The technical content of IEC publications is kept under constant review by the
IEC, thus ensuring that the content reflects current technology. Information
relating to this publication, including its validity, is available in the IEC
Catalogue of publications (see below) in addition to new editions,
amendments and corrigenda. Information on the subjects under consideration
and work in progress undertaken by the technical committee which has
prepared this publication, as well as the list of publications issued, is also
available from the following:
• IEC Web Site (www.iec.ch)
• Catalogue of IEC publications
The on-line catalogue on the IEC web site (www.iec.ch/catlg-e.htm)
enables you to search by a variety of criteria including text searches,
technical committees and date of publication. On-line information is also
available on recently issued publications, withdrawn and replaced
publications, as well as corrigenda.
• IEC Just Published
This summary of recently issued publications (www.iec.ch/JP.htm) is also
available by email. Please contact the Customer Service Centre (see
below) for further information.
• Customer Service Centre
If you have any questions regarding this publication or need further
assistance, please contact the Customer Service Centre:
Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD 61754-7
Edition 1.2
2000-11
Edition 1:1996 consolidated with amendments 1:1999 and 2:2000
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO

 IEC 2000 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale
U
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61754-7 © IEC:1996+A1:1999+A2:2000(E)

CONTENTS
Page
FOREWORD . 3

Clause
1 Scope . 5

2 Description. 5

3 Interfaces. 5

Figure 1 – MPO connector configurations. 6
Figure 2a – MPO female plug connector angled interface. 7
Figure 2b – Optical datum target location diagrams. 9
Figure 2c – Gauge pin . 10
Figure 2d – Gauge for plug . 11
Figure 3a – MPO male plug connector angled interface. 12
Figure 3b – Guide pin .14
Figure 4 – MPO adaptor interface . 15
Figure 5 – MPO female plug connector flat interface . 17
Figure 6 – MPO male plug connector flat interface . 19
Figure 7 – MPO backplane housing interface . 22
Figure 8 – MPO printed board housing interface. 25
Table 1a – Dimensions of the MPO female plug connector angled interface . 8
Table 1b – Dimensions of the gauge pin . 10
Table 1c – Dimensions of the gauge for plug. 11
Table 2a – Dimensions of the MPO male plug connector angled interface . 13
Table 2b – Dimensions of the guide pin. 14
Table 3 – Dimensions of the MPO adaptor interface. 16
Table 4 – Dimensions of the MPO female plug connector flat interface. 18
Table 5 – Dimensions of the MPO male plug connector flat interface. 20
Table 6a – Dimensions of the MPO backplane housing . 23

Table 6b – Grade. 24
Table 7 – Dimensions of the MPO printed board housing interface . 26

61754-7 © IEC:1996+A1:1999+A2:2000(E) – 3 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7: Type MPO connector family

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields.
To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations
liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that
compliance with this International Standard may involve the use of a patent concerning MPO connectors.
The IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he is willing to negotiate licences under reasonable and
non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of
the holder of this patent right is registered with the IEC. Information may be obtained from:
Intellectual Property Department,
Nippon Telegraph and Telephone Corporation,
20-2 Nishi-shinjuku 3-Chome Shinjukuku,
Tokyo 163-14, Japan.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights other than those identified above. IEC shall not be held responsible for identifying any or all
such patent rights.
International Standard IEC 61754-7 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This consolidated version of IEC 61754-7 is based on the first edition (1996) [documents
86B/836/FDIS and 86B/926/RVD], its amendment 1 (1999) [documents 86B/1213/FDIS and
86B/1250/RVD] and amendment 2 (2000) [documents 86B/1324/FDIS and 86B/1372/RVD].
It bears the edition number 1.2.
A vertical line in the margin shows where the base publication has been modified by
amendments 1 and 2.
– 4 – 61754-7 © IEC:1996+A1:1999+A2:2000(E)

A bilingual version of this publication may be issued at a later date.

The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2004. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or

• amended.
61754-7 © IEC:1996+A1:1999+A2:2000(E) – 5 –

FIBRE OPTIC CONNECTOR INTERFACES –

Part 7: Type MPO connector family

1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MPO family of
connectors.
2 Description
The parent connector for type MPO connector family is a multiway plug connector charac-
terized by a rectangular ferrule normally 6,4 mm × 2,5 mm which utilizes two pins of 0,7 mm
diameter as its alignment. It is applicable to a joint of multiple fibres up to 12 fibres by arraying
them between two pin-positioning holes in the ferrule. The connector includes a push-pull
coupling mechanism and a ferrule spring loaded in the direction of the optical axis. The
connector has a single male key which may be used to orient and limit the relative position
between the connector and the component to which it is mated.
Connector interfaces are configured using a female plug without pins, a male plug with pins
fixed and an adaptor as shown in figure 1. The female plug is intermateable with the male plug.
Moreover, connector interfaces between the female plug and the male plug are configured by
applying a backplane housing and a printed board housing instead of the adaptor.
Connector interfaces with different numbers of optical datum targets will intermate and will
correctly align the lower defined numbers of optical datum targets.
3 Interfaces
This standard contains the following standard interfaces.
Interface 7-1: MPO female plug connector angled interface – Push/pull
Interface 7-2: MPO male plug connector angled interface – Push/pull
Interface 7-3: MPO adaptor interface – Push/pull
Interface 7-4: MPO female plug connector flat interface – Push/pull

Interface 7-5: MPO male plug connector flat interface – Push/pull
Interface 7-6: MPO backplane housing interface – Self-retaining
Interface 7-7: MPO printed board housing interface – Self-retaining
The following standards are intermateable:
Female plugs Adaptors/housings Male plugs
61754-7-1 61754-7-3 61754-7-2
61754-7-4 61754-7-3 61754-7-5
61754-7-1 61754-7-6 and 61754-7-7 61754-7-2
61754-7-4 61754-7-6 and 61754-7-7 61754-7-5

– 6 – 61754-7 © IEC:1996+A1:1999+A2:2000(E)

Female plug Adaptor
Male plug
Printed
Backplane
board
housing
housing
IEC  1065/2000
Figure 1 – MPO connector configurations

61754-7 © IEC:1996+A1:1999+A2:2000(E) – 7 –

Figure 2a – MPO female plug connector angled interface

– 8 – 61754-7 © IEC:1996+A1:1999+A2:2000(E)

Table 1a – Dimensions of the MPO female plug connector angled interface

Reference Dimensions Notes
Minimum Maximum
A 0,699 mm 0,701 mm 1
B 7,9 mm 8,1 mm
C 4,597 mm 4,603 mm 2
D 6,3 mm 6,5 mm
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm 3
J 7,9 mm 8,1 mm
K 1,4 mm –
L 0,2 mm 0,8 mm 4 and 5
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42° 45°
AB – 45°
AC – 45°
AD 7,5° 8,5°
NOTE 1 Each pin-hole shall accept a gauge pin as shown in figure 2c to a depth of 5,5 mm with a maximum force
of 1,7 N. In addition, two pin-holes of a plug shall accept a gauge as shown in figure 2d to a depth of 5,5 mm with a
maximum force of 3,4 N.
NOTE 2 Dimension C is defined as the distance between two pin-hole centres.
NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is
movable by a certain axial compression force, and therefore t
...

Questions, Comments and Discussion