Rubber compounding ingredients — Carbon black — Determination of light transmittance of toluene extract — Part 1: Rapid method

Ingrédients de mélange du caoutchouc — Noir de carbone — Détermination de la transmittance spectrale de l'extrait toluénique — Partie 1: Méthode rapide

General Information

Status
Withdrawn
Publication Date
30-Nov-1983
Withdrawal Date
30-Nov-1983
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Aug-1990
Ref Project

Relations

Effective Date
15-Apr-2008

Buy Standard

Standard
ISO 3858-1:1983 - Rubber compounding ingredients -- Carbon black -- Determination of light transmittance of toluene extract
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 3858-1:1983 - Rubber compounding ingredients — Carbon black — Determination of light transmittance of toluene extract — Part 1: Rapid method Released:12/1/1983
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

International Standard @ 385811
~~~
INTERNATIONAL ORGANIZATION FOR STANOARDIZATION.MEMflYHAPOflHAR OPrAHH3AUHR Il0 CTAHAAPTH3AUHH.ORGANlSATlON INTERNATIONALE DE NORMALISATION
Rubber compounding ingredients - Carbon black -
Determination of light transmittance of toluene extract -
Part 1 : Rapid method
Ingrédients de mélange du caoutchouc - Noir de carbone - Détermination de la transmittance spectrale de l'extrait
toluénique - Partie 1 : Méthode rapide
Second edition - 1983-12-15
I
-
Ref. No. IS0 3858/1-1983 (E)
UDC 678.046.2:620.1
8
z
c Descriptors : rubber industry, carbon black, physical tests, determination, toluene, transmittance, discoloration.
.
s
Price based on 2 pages

---------------------- Page: 1 ----------------------
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of developing International
Standards is carried out through IS0 technical committees. Every member body
interested in a subject for which a technical committee has been authorized has the
right to be represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council.
International Standard IS0 3858/1 was developed by Technical Committee
ISO/TC 45, Rubber and rubber products.
This second edition was submitted directly to the IS0 Council, in accordance with
clause 6.11.2 of part 1 of the Directives for the technical work of ISO. It cancels and
replaces the first edition (i.e. IS0 3858-19771, which had been approved by the member
bodies of the following countries :
Australia
India Spain
Belgium
Ireland Sweden
Bulgaria Italy Thailand
Canada
Mexico Turkey
France Netherlands United Kingdom
Germany, F. R. Romania USSR
Hungary South Africa, Rep. of Yugoslavia
No member body had expressed disapproval of the document.
0 International Organization for Standardization, 1983 O
Printed in Switzerland

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD IS0 3858/1-1983 (E)
Rubber compounding ingredients - Carbon black -
Determination of light transmittance of toluene extract -
Part 1 : Rapid method
O Introduction 5.2 Oven, preferably gravity convection type, capable of be-
ing maintained at 105 f 2 OC.
IS0 3858 consists of the following parts :
-
Part 1 : Rapid method. 5.3 Spectrometer, giving direct readings of light
transmittance at 425 nm, and with a selector for continuous
- a high resolution prism or grating.
variation, for example
Part 2 : Method for product evaluation.
0 Bandpass shall be within f 10 nm (see note 1).
1 Scope and field of application
AC nstant voltage transformer shall be ins rted into the supply
This part of IS0 3858 specifies a rapid method for the circuit if the voltage is known to vary by more than 4 V.
determination of the light transmittance of the toluene extract
from carbon black by means of a spectrometer.
The spectrometer shall be equipped with absorption cells, of
The method provides a qualitative indication of the degree of thickness 10,OO f 0,05 mm (see notes 2 and 3). with parallel
discoloration of toluene by carbon blacks for use in the rubber
sides polished flat to within 10 nm.
industry.
NOTES
2 References
1 Current types of colorimeters may differ by the width of a passing
band and may therefore give different transmittance results. The
IS0 471, Rubber - Standard temperatures, humidities and
results may be more comparable if such colorimeters are calibrated
times for the conditioning and testing of test pieces.
against the same high resolution spectrometer, for example having a
passing band which is narrower than 2 nm at 425 nm mean
wavelength, and the readings corrected by using the calibration curve
IS0 1126, Carbon black for use in the rubber industry - Deter-
for each instrument through the useful range of transmittance.
mination of loss on heating.
e
2 Cylindrical cells of inner diameter 10,OO f 0,05 mm may give dif-
ferent results from parallelepipedic cells. If used, it is recommended
3 Principle
that they be calibrated against a parallelepipedic cell over the full useful
range of transmittance and that corrections be taken from the calibra-
Drying of the carbon black and weighing of a test portion.
tion curve.
Mixing with a measured volume of toluene at room
3 If the cell used does not give a 10 mm optical path length, the
temperature. Filtration of the mixture and transfer of the filtrate
transmittance which would be obtained through a cell of 10 mm is
to an absorption cell. Measurement of the light transmittance
given
...

Norme internationale @ 385811
INTERNATIONAL ORGANIZATION FOR STANOAROIZATION*ME~~YHAPOi(IHAR OPrAHHJAUMA nO CTAHAAPTM3AUMM*ORGANlSATlON INTERNATIONALE DE NORMALISATION
Ingrédients de mélange du caoutchouc - Noir de
a
carbone - Détermination de la transmittance spectrale de
l'extrait toluénique -
Partie I : Méthode rapide
Rubber compounding ingredients - Carbon black - Determination of light transmittance of toluene extract -
Part 1 : Rapid method
Deuxième édition - 1983-12-15
-
' CDU 678.046.2: 620.1 Réf. no : IS0 3858/1-1983 (FI
8
O!
- Descripteurs : industrie des élastomères, noir de carbone, essai physique, toluène, facteur de transmission, décoloration.
s
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
Avant-propos
L'ISO (organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
des Normes internationales est confiée aux comités techniques de I'ISO. Chaque
comité membre intéressé par une étude a le droit de faire partie du comité technique
correspondant. Les organisations internationales, gouvernementales et non gouverne-
mentales, en liaison avec I'ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I'ISO.
La Norme internationale IS0 =/I a été élaborée par le comité technique ISO/TC 45,
Élastomères et produits à base d'élastomères.
Cette deuxième édition fut soumise directement au Conseil de I'ISO, conformément au
paragraphe 6.11.2 de la partie 1 des Directives pour les travaux techniques de I'ISO.
Elle annule et remplace la première édition (IS0 3858-1977). qui avait été approuvée par
les comités membres des pays suivants :
Afrique du Sud, Rép. d'
France Roumanie
Allemagne, R. F. Hongrie Roya urne- U ni
Australie Inde
Suède
Belgique Irlande Thaïlande
Bulgarie Italie
Turquie
Canada Mexique URSS
Espagne Pays-Bas Yougoslavie
Aucun comité membre ne l'avait désapprouvée.
O Organisation internationale de normalkation, 1983 O
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE IS0 3858/1-1983 (FI
Ingrédients de mélange du caoutchouc - Noir de
carbone - Détermination de la transmittance spectrale de
l'extrait toluénique -
Partie 1 : Méthode rapide
O Introduction 5.2 Étuve, de préférence à tirage naturel, permettant de
maintenir une température de 105 f 2 OC.
L'ISO 3858 comprend les parties suivantes :
5.3 Spectromètre, permettant une lecture directe de la
-
Partie 1 : Méthode rapide.
transmittance spectrale à 425 nm, à sélecteur de radiations à
variation continue, par exemple prisme ou réseau de haute
-
Partie 2 : Méthode d'évaluation du produit.
résolution. La bande passante doit être dans les limites de
O
f 10 nm (voir note 1).
1 Objet et domaine d'application
On doit insérer un stabilisateur de tension dans le circuit d'ali-
mentation si l'on sait que ta tension peut varier de plus de 4 V.
La présente partie de I'ISO 3858 spécifie une méthode rapide de
détermination de la transmittance spectrale de l'extrait toluéni-
Le spectromètre doit être équipé de cuves d'absorption de
que du noir de carbone au moyen d'un spectromètre.
10,OO f 0,05 mm d'épaisseur (voir notes 2 et 3) et dont les
faces parallèles planes sont polies à 10 nm près.
La méthode donne une indication qualitative du degré de déco-
à I'indus-
loration du toluène par des noirs de carbone destinés
NOTES
trie du caoutchouc.
1 Les modèles courants de colorimètres peuvent différer par la lar-
geur de la bande passante et donner ainsi des résultats différents de
2 Références transmittance spectrale. Les résultats obtenus avec de tels appareils
peuvent être rendus plus comparables si on étalonne ces appareils par
rapport à un spectromètre de haute résolution, ayant par exemple une
IS0 471, Caoutchouc - Températures, humidités et durées
bande passante de largeur inférieure à 2 nm pour une longueur d'onde
normales pour le conditionnement et /'essai des éprouvettes.
moyenne de 425 nm, et si les lectures sont corrigées en utilisant la
courbe d'étalonnage de chaque instrument établie pour toute la
IS0 1126, Noir de carbone pour /'industrie des élastomères -
gamme utile de transmittance spectrale.
Détermination de la perte à la chaleur.
2 Les cuves cylindriques de 10,OO f 0,05 mm de diamètre intérieur
peuvent donner des résultats différents par rapport aux cuves parallélé-
pipédiques. Si on les utilise, il est recommandé de les étalonner par rap-
3 Principe
port à une cuve parallélépipédique pour toute la gamme utile de trans-
mittance spectrale et de corriger les résultats d'après la courbe d'éta-
Séchage du noir de carbone et pesée d'une prise d'essai.
lonnage.
Mélangeage avec un certain volume de toluène à la tempéra-
ture ambiante. Filtration du mélange formé et transvasement
3 Si le parcours optique à travers la cuve n'est pas égal à 10 mm, la
du filtrat dans une cuve d'absorption. Mesurage de la transmit-
transmittance spectrale que l'on obtiendrait avec une cuve de 10 mm
tance spectrale du filtrat par rapport au toluène pur, à l'aide
est donnée par l'équation
d'un spectromètre réglé à une longueur d'onde sélectionnée.
10 20
lg To=TXIgT--+2 I
4 Réacti
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.