ISO 17742:2015
(Main)Energy efficiency and savings calculation for countries, regions and cities
Energy efficiency and savings calculation for countries, regions and cities
ISO 17742:2015 provides a general approach for energy efficiency and energy savings calculations with indicator-based and measure-based methods for the geographical entities countries, regions, and cities. ISO 17742:2015 considers all end-use sectors, such as households, industry, tertiary (services, etc.), agriculture, and transport. It does not incorporate calculation of energy efficiency and energy savings in energy supply sectors, such as power plants, refineries, and coal mines.
Calcul de l'efficacité énergétique et des économies d'énergie pour les pays, villes et régions
L'ISO 17742:2015 fournit une approche globale pour les calculs de l'efficacité énergétique et des économies d'énergie basés sur des méthodes fondées sur des indicateurs ou fondées sur des mesures. Elle s'applique aux entités géographiques de type pays, régions et villes. L'ISO 17742:2015 prend en compte tous les secteurs d'utilisation finale, tels que les ménages, l'industrie, le tertiaire (services, etc.), l'agriculture et le transport. Elle n'intègre pas le calcul de l'efficacité et des économies d'énergie dans le secteur de l'approvisionnement énergétique, comme les centrales électriques, les raffineries et les mines de charbon.
General Information
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 17742
First edition
2015-08-15
Energy efficiency and savings
calculation for countries, regions and
cities
Calcul de l’efficacité énergétique et des économies d’énergie pour les
pays, villes et régions
Reference number
ISO 17742:2015(E)
©
ISO 2015
---------------------- Page: 1 ----------------------
ISO 17742:2015(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2015, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 17742:2015(E)
Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Terms and definitions . 1
3 Savings to be calculated . 7
3.1 General . 7
3.2 Types of savings to be calculated . 7
3.2.1 Energy savings as part of energy consumption development . 7
3.2.2 Contributions to change of various types of energy savings . 9
3.2.3 Savings types for different cases .10
3.3 Methods, applications, and calculated savings .11
3.3.1 Indicator-based calculation method .11
3.3.2 Hidden structure effects in the indicator-based method .12
3.3.3 Measure-based calculation method .12
3.3.4 Energy baseline and additional savings in the measure-based method .13
3.3.5 Aggregated results of indicator-based and measure-based methods .13
3.3.6 Demarcation and integration of indicator-based and measure-based methods .14
3.3.7 Incorporation of other policies that affect energy consumption .14
4 Indicator-based savings calculations .15
4.1 Indicators and calculation of savings .15
4.1.1 Energy efficiency indicators .15
4.1.2 Structure effects and disaggregation .15
4.1.3 Indicator choice and savings definition .16
4.2 General calculation of indicator-based energy savings .16
4.2.1 Calculation approach .16
4.2.2 Step 1: Choice of indicator types .17
4.2.3 Step 2: Calculation of indicator values .17
4.2.4 Step 3: Calculation of energy savings per indicator .20
4.3 Computational issues in the calculation of indicator-based savings.21
4.3.1 General.21
4.3.2 Variants of the calculation method .22
4.3.3 Energy consumption units .23
4.3.4 Overall indicator-based energy savings .24
4.4 Reliability of saving figures .24
4.4.1 Indicators resulting in negative savings .24
4.4.2 The quality of indicator-based energy-saving figures .24
5 Measure-based savings calculations .26
5.1 Measures and calculation of savings .26
5.1.1 Elementary unit of action and unitary energy savings .26
5.1.2 Energy baseline options for end-user actions .27
5.1.3 Savings types from measure-based calculations .28
5.2 General calculation of measure-based energy savings.29
5.2.1 Calculation approach .29
5.2.2 Step 1: Calculation of unitary gross annual energy savings .31
5.2.3 Step 2: Calculation of total gross annual energy savings .36
5.2.4 Step 3: Calculation of total (net) annual energy savings .38
5.2.5 Step 4: Calculation of remaining energy savings for the calculation year .40
5.2.6 Calculation of overall measure-based energy savings, taken into
account overlap .40
5.3 Reliability of calculated savings .41
Annex A (informative) Examples of energy efficiency indicators .43
Annex B (informative) Level of detail and data handling in measure-based calculations .51
© ISO 2015 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 17742:2015(E)
Bibliography .53
iv © ISO 2015 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 17742:2015(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT), see the following URL: Foreword — Supplementary information.
The committee responsible for this document is ISO/TC 257, Evaluation of energy savings.
© ISO 2015 – All rights reserved v
---------------------- Page: 5 ----------------------
ISO 17742:2015(E)
Introduction
Due to the recognized role of savings in international climate and energy policy, e.g. expressed by
[9]
International Energy Agency, there is a need for harmonized methods at the international level.
In addition, many countries that have formulated policies and targets have a need for evaluating the
energy savings achieved, or the impact of implemented policies, and need these calculation methods as
well.
This International Standard concerns savings at the level of countries, regions, and cities. The practical
application can be different due to specific restrictions, such as the availability of data at lower levels.
This International Standard is meant to calculate both realized savings (ex-post evaluation) as well
as expected savings (ex-ante evaluation). The latter is only possible if detailed data on future energy
developments is available.
This International Standard can be used by any stakeholder (decision makers, companies, NGO, etc.)
that wants to quantify the energy savings over a specific period.
This International Standard is part of a set of International Standards developed in TC 257 (see Figure 1)
and builds on the general principles outlined in ISO 17743, including reporting and system boundaries.
Figure 1 — Work programme of ISO/TC 257
This International Standard covers both indicator-based and measure-based calculation methods. The
indicator method is based on energy indicators (e.g. mean gas consumption per dwelling) which are
vi © ISO 2015 – All rights reserved
---------------------- Page: 6 ----------------------
ISO 17742:2015(E)
often calculated from statistical data. The measure-based method considers the saving effect of policy
measures or measures taken by other stakeholders to enhance energy efficiency.
The indicator-based and measure-based calculation methods are presented as two separate calculation
methods. Using a combination of indicator-based and measure-based methods is not part of this
International Standard. However, the differences and application of both methods are highlighted.
This International Standard provides a general framework for calculating energy savings. For the
indicator-based methods, examples of specific calculations per indicator are presented separately in
Annex A.
When applying this International Standard, the user can choose between different variants of the
indicator- or measure-based method. In order to be transparent on the way results have been obtained,
the user of this International Standard has to specify the variant used when presenting the results.
In order to ensure the credibility of the results, all savings calculations have to be documented to the
point of allowing them to be duplicated or reproduced by an independent analyst. The requirements are
specified in detail when this International Standard is elaborated for concrete calculation applications
(see also ISO 17743).
The energy-saving types to be calculated, and the characteristics of the indicator-based and measure-
based methods, are presented in Clause 3. The standard on the indicator-based calculation method is
described in Clause 4 and that on the measure-based calculation methods in Clause 5. Annex A provides
some example indicators that can be used in indicator-based calculations. Annex B shows the levels of
detail at which measure-based methods can be applied.
© ISO 2015 – All rights reserved vii
---------------------- Page: 7 ----------------------
INTERNATIONAL STANDARD ISO 17742:2015(E)
Energy efficiency and savings calculation for countries,
regions and cities
1 Scope
This International Standard provides a general approach for energy efficiency and energy savings
calculations with indicator-based and measure-based methods for the geographical entities countries,
regions, and cities.
This International Standard considers all end-use sectors, such as households, industry, tertiary
(services, etc.), agriculture, and transport. It does not incorporate calculation of energy efficiency and
energy savings in energy supply sectors, such as power plants, refineries, and coal mines.
Energy consumption does not include feedstock energy, such as oil products for the production of
plastics.
This International Standard is not intended to be used for calculating energy savings of individual
households, organizations, companies, or other end users.
Energy from renewable energy sources “behind-the-meter” (e.g. from solar water heating panels)
decreases the amount of supplied energy and can be part of the calculated energy savings. Users of this
International Standard should be aware that this energy from renewable energy sources behind-the-
meter can also be claimed as part of the total energy from renewable sources.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
adjustment factor
quantifiable parameter affecting energy consumption
Note 1 to entry: In this International Standard, adjustment factors for indicator-based methods are restricted to
corrections for variations in weather conditions.
Note 2 to entry: In this International Standard, adjustment factors for measure-based methods include production
throughput, weather conditions, working hours, behaviour related parameters (e.g. indoor temperature and light
level), etc.
Note 3 to entry: Factors at high aggregation level that affect the savings attributed to policies or programs (e.g.
free rider effect or rebound effect) are not part of the adjustment factors.
[SOURCE: ISO 17743, modified — with notes instead of examples.]
2.2
city
geographical area under control of a municipal administration
Note 1 to entry: The municipal administration is subject to provincial and national governance.
2.3
country
geographical area under control of a national government
Note 1 to entry: According to the definition of the UN Statistical Office.
© ISO 2015 – All rights reserved 1
---------------------- Page: 8 ----------------------
ISO 17742:2015(E)
2.4
deemed savings
default value for unitary energy savings, estimated and/or agreed to by stakeholders
Note 1 to entry: The default value can be based on available measurements or calculations.
2.5
diffusion indicator
indicator showing the penetration of energy-saving devices, systems, or practices
EXAMPLE Number of solar water heaters, efficient lamps or electrical appliances with a label A+ or A++,
fraction of passenger transport by public modes, or transport of goods by rail and water.
2.6
double counting
counting the savings for a combination of facilitating measures, focusing on the same end-user action,
as the sum of what would be saved by each measure alone, when the combined savings is less than the
sum
Note 1 to entry: In this International Standard, double counting is not valid for elementary units of action (e.g. the
saving effect of insulation and high efficiency boiler) where it is termed technical interaction.
Note 2 to entry: In this International Standard, double counting is used for calculation at high aggregation level
(e.g. all dwellings), while the term consequential effects can be used at lower aggregation level (e.g. individual
company) in other International Standards.
[SOURCE: CEN 16212, modified — definition adapted.]
2.7
driver
quantity that is assumed to predominantly influence the level of energy consumption under
consideration in indicator-based methods
Note 1 to entry: A driver can be an activity (e.g. production) but also a property of a system (e.g. amount of floor
space).
2.8
elementary unit of action
entity for which unitary energy savings can be defined and summed up
Note 1 to entry: Generally, it relates to an energy using system or a participant in an energy savings programme.
2.9
end-user action
energy efficiency improvement measure implemented on the site of an end user
2.10
energy baseline
quantitative reference(s) providing a basis for comparison of energy performance
Note 1 to entry: An energy baseline usually reflects a specified period of time.
Note 2 to entry: An energy baseline can be adjusted using variables affecting energy use and/or consumption
such as production level, degree days (outdoor temperature), etc.
Note 3 to entry: With respect to energy performance, the definition for this International Standard only concerns
energy efficiency.
[SOURCE: ISO/IEC 13273-1, 3.3.10, modified — adapted notes.]
2 © ISO 2015 – All rights reserved
---------------------- Page: 9 ----------------------
ISO 17742:2015(E)
2.11
energy carrier
substance or phenomenon that can be used to produce mechanical work or heat or to operate a process
EXAMPLE Electricity, hydrogen, and automotive fuels that can be used by energy using systems.
[SOURCE: ISO/IEC 13273-1, 3.1.2, modified — without note.]
2.12
energy consumption
quantity of energy applied
Note 1 to entry: The unit of energy consumption can be expressed related to the involved energy carrier but also
in the standard unit for energy, Joule.
[SOURCE: ISO/IEC 13273-1, 3.1.15]
2.13
energy consumption in final units
final energy when energy carriers are counted according to their energy content
Note 1 to entry: The energy content values can be taken from energy statistics where they are applied to sum up
the energy consumption of different energy carriers.
2.14
energy consumption in primary units
final energy when energy carriers are counted according to the energy consumption needed to deliver
them to the end users
Note 1 to entry: For instance, the consumption of electricity is multiplied with a factor of 2,5 when the conversion
of fuels to electricity has an efficiency of 40 %.
Note 2 to entry: In this way, it is possible to account for the fact that savings on final energy consumption can also
reduce transformation losses in the energy supply system.
2.15
energy efficiency
ratio or other quantitative relationship between an output of performance, service, goods, or energy
and an input of energy
EXAMPLE Energy conversion efficiency; energy required/energy used; output/input; theoretical energy
used to operate/energy used to operate.
[SOURCE: ISO/IEC 13273-1, 3.4.1, modified — without notes.]
2.16
energy efficiency improvement
increase in energy efficiency as a result of technological, design, behavioural, and/or economic changes
[SOURCE: ISO/IEC 13273-1, 3.4.3]
2.17
energy efficiency improvement measure
action normally leading to an energy efficiency improvement which can be verified, measured or
estimated
Note 1 to entry: Measure encompasses both end-user action and facilitating measure.
© ISO 2015 – All rights reserved 3
---------------------- Page: 10 ----------------------
ISO 17742:2015(E)
2.18
energy end user
individual or a group of individuals or organization with responsibility for operating an energy using
system
Note 1 to entry: The energy end user can differ from the customer who might purchase the energy but does not
necessarily use it.
[SOURCE: ISO/IEC 13273-1, 3.1.12]
2.19
energy savings
reduction of energy consumption compared to an energy baseline
Note 1 to entry: Energy savings can be realized or expected.
Note 2 to entry: Energy savings can be the result of implementation of an action(s) or of autonomous progress.
[SOURCE: ISO/IEC 13273-1, 3.3.11, last part of definition and notes adapted]
2.20
energy use
manner or kind of application of energy
Note 1 to entry: Characteristics of energy use include, but are not limited to, the purpose of the use, source(s)
choice, and application.
[SOURCE: ISO/IEC 13273-1, 3.1.14]
2.21
energy using system
physical item with defined system boundaries, using energy
Note 1 to entry: An energy using system can be one or many plants, processes, parts of a process, buildings, parts
of a building, machines, equipment, products, etc.
[SOURCE: ISO/IEC 13273-1, 3.1.11]
2.22
facilitating measure
energy efficiency service or an improvement programme offered to an energy end user
Note 1 to entry: A facilitating measure is offered by a stakeholder that is not the energy end user.
EXAMPLE A subsidy scheme for insulation of dwellings or a label on the efficiency of appliances.
2.23
feedstock energy
energy of raw materials which is used for non-energy purposes
EXAMPLE Oil for producing plastics and natural gas for producing fertilizers.
[SOURCE: ISO/IEC 13273-1, 3.1.3, modified — adapted example.]
2.24
final energy
energy as delivered to the energy using system
Note 1 to entry: This concept is sometimes referred to as delivered energy.
[SOURCE: ISO/IEC 13273-1, 3.1.13]
4 © ISO 2015 – All rights reserved
---------------------- Page: 11 ----------------------
ISO 17742:2015(E)
2.25
free rider effect
provision of financial incentives for saving measures to end users who would have taken the measures
anyway
EXAMPLE Savings arising from subsidies, or tax reductions, provided to end users that would have taken
the measures anyway.
Note 1 to entry: The free rider effect can be estimated through, for example, a comparison with energy savings
realized in similar circumstances but without the subsidy scheme.
2.26
gross energy savings
energy savings using adjustment factors, but except correction for double counting, multiplier effect,
free riders, and rebound effect
Note 1 to entry: Gross energy savings include adjustment factors mentioned in 2.1.
2.27
indicator-based method
determination of energy savings from the variation of energy consumption indicators over a period
EXAMPLE For industry, a decrease in energy consumption per tonne of steel is accounted for as savings.
2.28
indicator-based savings
energy savings calculated with indicator-based methods
2.29
measure-based method
determination of energy savings from end-user actions using unitary energy savings and elementary
units of action
Note 1 to entry: If end-user actions are due to facilitating measures, such as policy, the measure-based methods
consider savings due to policy.
EXAMPLE In case of a subsidy scheme for boilers in households, the savings are calculated from the average
savings per boiler (compared to a chosen reference boiler) times the number of subsidized boilers (corrected for
free riders that apply for subsidy but would have installed the efficient boiler anyway).
2.30
measure-based savings
energy savings calculated with measure-based methods
2.31
multiplier effect
effect of a facilitating measure after the measure has ended or in fields outside the focus
EXAMPLE Temporarily promotion of efficient appliances changes the market for these appliances in such a
way that further penetration occurs after ending the promotion activity.
Note 1 to entry: In the standard, the multiplier effect is used for calculations at high aggregation level (e.g. all
dwellings), while the term consequential effects can be used at lower aggregation level (e.g. individual company)
in other standards.
2.32
net energy savings
energy savings with use of the adjustment factor(s) and, if relevant, correction factors for double
counting, multiplier effect, free riders and rebound effect
© ISO 2015 – All rights reserved 5
---------------------- Page: 12 ----------------------
ISO 17742:2015(E)
2.33
rebound effect
change in energy using behaviour that yields an increased level of service and that occurs as a result of
taking an end-use action
EXAMPLE Some households can take some of the benefits of energy efficiency improvements to their home
in the form of higher internal temperatures, and so use more energy than might be calculated from the end-user
action.
Note 1 to entry: The rebound effect can take many forms. Apart from the case in the example (higher internal
temperature setting) the effect is often difficult to determine.
2.34
region
geographical area with the ability to influence energy savings, not being a city or a country
2.35
saving lifetime
number of years for which savings of end-user actions remain present
Note 1 to entry: The savings lifetime can take into account deterioration of yearly savings.
EXAMPLE See list of specified lifetimes in Annex of Reference [8].
2.36
specific energy consumption
quotient describing the total amount of energy necessary to generate a unit of output, activity, economic
value, or service
2
EXAMPLE Gigajoule (GJ) per ton of steel, annual kilowatt hour (kWh) per square meter (m ), litres of fuel
per kilometre (km), etc.
[SOURCE: ISO/IEC 13273-1, 3.1.17]
2.37
structure effect
changes in activities or characteristics of energy using systems that affect energy consumption, not
being energy savings
EXAMPLE Intensity of use for appliances, occupation rate for buildings, and shift in between sectors for
industry.
Note 1 to entry: The actual form of the structure effects differs for the various aggregation levels in calculations
(country, sector, organization, building, etc.).
Note 2 to entry: For the indicator-based method, the effect of the driver on energy consumption is, by definition,
not part of the structure effect.
Note 3 to entry: For the measure-based method, the demarcation between structure effect and savings can be
dependent on formulating policy as savings measure or another measure (e.g. speed limits for traffic to avoid
accidents or to save petrol).
2.38
system boundary
physical or site limits as defined for a stated purpose
EXAMPLE A process; a site; an organization; a city, a region, or a country.
Note 1 to entry: The stated purpose could be for a management system, or for a savings program with a given
national, regional, or local scope.
[SOURCE: ISO/IEC 13273-1, 3.3.2, modified — example with extended scope, notes adapted.]
6 © ISO 2015 – All rights reserved
---------------------- Page: 13 ----------------------
ISO 17742:2015(E)
2.39
technical interaction
relation of the elementary unit of action to the surrounding technical system, or to other elementary
units of action, which influences the unitary energy savings
Note 1 to entry: In case of technical interaction between two elementary units of action, both energy savings
cannot be simply summed up.
EXAMPLE The combination of thermal insulation and a new efficient boiler where the combined savings are
smaller than the sum of the savings for each unit of action apart.
2.40
unitary energy savings
calculated energy savings per elementary unit of action
Note 1 to entry: Also called “unitary g
...
NORME ISO
INTERNATIONALE 17742
Première édition
2015-08-15
Calcul de l’efficacité énergétique et
des économies d’énergie pour les
pays, villes et régions
Energy efficiency and savings calculation for countries, regions and
cities
Numéro de référence
ISO 17742:2015(F)
©
ISO 2015
---------------------- Page: 1 ----------------------
ISO 17742:2015(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2015, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 17742:2015(F)
Sommaire Page
Avant-propos .v
Introduction .vi
1 Domaine d’application . 1
2 Termes et définitions . 1
3 Économies d’énergie à calculer . 7
3.1 Généralités . 7
3.2 Types d’économies d’énergie à calculer . 8
3.2.1 Économies d’énergie considérées dans le cadre du développement de la
consommation d’énergie . 8
3.2.2 Contributions aux variations de différents types d’économies d’énergie . 9
3.2.3 Types d’économies d’énergie pour les différents cas.11
3.3 Méthodes, applications et économies calculées .13
3.3.1 Méthode de calcul fondée sur des indicateurs .13
3.3.2 Effets de structure cachés dans la méthode fondée sur des indicateurs .13
3.3.3 Méthode de calcul fondée sur des mesures .14
3.3.4 Situation de référence et économies supplémentaires dans la méthode
fondée sur des mesures .14
3.3.5 Résultats agrégés des méthodes fondées sur des indicateurs et des
méthodes fondées sur des mesures .15
3.3.6 Démarcation et intégration de la méthode fondée sur des indicateurs et
de la méthode fondée sur des mesures .16
3.3.7 Incorporation d’autres politiques qui influent sur la
consommation énergétique.16
4 Calculs des économies d’énergie basées sur des indicateurs .17
4.1 Indicateurs et calcul des économies .17
4.1.1 Indicateurs d’efficacité énergétique .17
4.1.2 Effets de structure et désagrégation .17
4.1.3 Choix des indicateurs et définition des économies .18
4.2 Calcul général des économies d’énergie basées sur des indicateurs .18
4.2.1 Méthode de calcul .18
4.2.2 Étape 1: Choix des types d’indicateurs .19
4.2.3 Étape 2: Calcul de la valeur des indicateurs .20
4.2.4 Étape 3: Calcul des économies d’énergie par indicateur .22
4.3 Questions mathématiques dans le calcul des économies d’énergie basées sur
des indicateurs .24
4.3.1 Généralités .24
4.3.2 Variantes de la méthode calcul, .24
4.3.3 Unités de consommation d’énergie .25
4.3.4 Économies d’énergie globales basées sur des indicateurs .26
4.4 Fiabilité des chiffres reflétant les économies d’énergie .27
4.4.1 Indicateurs traduisant des économies d’énergie négatives .27
4.4.2 Qualité des chiffres reflétant les économies d’énergie basées sur
des indicateurs .27
5 Calculs des économies d’énergie basées sur des mesures .29
5.1 Mesures et calcul des économies .29
5.1.1 Unité élémentaire d’action et économies d’énergie unitaires .29
5.1.2 Options de situations de référence pour les actions d’utilisation finale.30
5.1.3 Types d’économies des calculs basés sur des mesures .31
5.2 Calcul général des économies d’énergie basées sur des mesures .32
5.2.1 Méthode de calcul .32
5.2.2 Étape 1: Calcul des économies d’énergie annuelles brutes unitaires.34
5.2.3 Étape 2: Calcul des économies d’énergie annuelles brutes totales .40
© ISO 2015 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 17742:2015(F)
5.2.4 Étape 3: Calcul des économies d’énergie annuelles (nettes) totales .41
5.2.5 Étape 4: Calcul des économies d’énergie restantes pour l’année de calcul.43
5.2.6 Calcul des économies d’énergie globales basées sur des mesures, avec
prise en compte des chevauchements .44
5.3 Fiabilité des économies d’énergie calculées .45
Annexe A (informative) Exemples d’indicateurs d’efficacité énergétique .46
Annexe B (informative) Niveau de détail et traitement des données dans les calculs basés
sur des mesures .55
Bibliographie .57
iv © ISO 2015 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 17742:2015(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/patents).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer
un engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos -
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 257, Évaluation des économies d’énergie.
© ISO 2015 – Tous droits réservés v
---------------------- Page: 5 ----------------------
ISO 17742:2015(F)
Introduction
En raison du rôle reconnu des économies d’énergie dans les politiques climatiques et énergétiques
[9]
internationales, soutenu notamment par l’Agence internationale de l’énergie, il devient nécessaire
d’harmoniser les méthodes au plan international. D’autre part, les pays qui ont formulé des politiques
et des objectifs souhaitent évaluer les économies d’énergie réalisées ou estimer l’impact des politiques
mises en œuvre, et ont besoin de ces méthodes de calcul.
La présente Norme internationale concerne les économies d’énergie au niveau des pays, des régions et
des villes. L’application pratique peut être différente en raison de restrictions spécifiques, telles que la
disponibilité des données aux niveaux inférieurs.
La présente Norme internationale a pour objet de calculer les économies réalisées (évaluation ex-post)
et les économies attendues (évaluation ex-ante). Le calcul des économies attendues est uniquement
possible si des données détaillées des développements énergétiques futurs sont disponibles.
La présente Norme internationale s’adresse à toute partie prenante (décideurs, entreprises, ONG, etc.)
qui souhaite quantifier des économies d’énergie sur une période spécifique.
La présente Norme internationale fait partie d’un ensemble de Normes internationales élaborées dans
le cadre de la TC 257 (voir Figure 1) et s’appuie sur les principes généraux décrits dans l’ISO 17743, y
compris la génération de rapports et le périmètre du système.
Figure 1 — Programme de travail de l’ISO 257
vi © ISO 2015 – Tous droits réservés
---------------------- Page: 6 ----------------------
ISO 17742:2015(F)
La présente Norme internationale couvre les méthodes de calcul fondées sur des indicateurs et les
méthodes de calcul fondées sur des mesures. La méthode des indicateurs est basée sur des indicateurs
énergétiques (par exemple, la consommation moyenne de gaz par logement) qui sont souvent calculés à
partir de données statistiques. La méthode fondée sur des mesures prend en compte l’effet d’économie
induit par des dispositions politiques ou des mesures prises par d’autres acteurs, afin d’améliorer
l’efficacité énergétique.
Les méthodes fondées sur des indicateurs et les méthodes fondées sur des mesures sont présentées
comme deux méthodes de calcul distinctes. La combinaison de ces méthodes ne fait pas partie de
la présente Norme internationale. Cependant, les différences et l’application de ces deux méthodes y
sont décrites.
La présente Norme internationale fournit un cadre général pour le calcul des économies d’énergie.
Pour les méthodes fondées sur des indicateurs, l’Annexe A propose des exemples de calculs spécifiques
propres à chaque indicateur.
Lors de l’application de la présente Norme internationale, l’utilisateur peut choisir entre les différentes
variantes de la méthode fondée sur des indicateurs ou de la méthode fondée sur des mesures. Pour
garantir la transparence des résultats obtenus, l’utilisateur de la présente Norme internationale doit
indiquer la variante utilisée lors de la présentation des résultats.
Pour garantir la crédibilité des résultats, tous les calculs d’économies doivent être documentés afin
de rendre leur reproductibilité possible par un analyste indépendant. Les exigences sont spécifiées de
façon détaillée lorsque la présente Norme internationale est élaborée pour des applications de calcul
concrètes (voir également l’ISO 17743).
Les types d’économie d’énergie à calculer ainsi que les caractéristiques des méthodes fondées sur des
indicateurs ou fondées sur des mesures sont présentées à l’Article 3. Les considérations relatives à la
méthode de calcul fondée sur des indicateurs sont décrites à l’Article 4 et celles relatives aux méthodes
de calcul fondées sur des mesures sont traitées à l’Article 5. L’Annexe A fournit quelques exemples
d’indicateurs susceptibles d’être utilisés dans des calculs basés sur des indicateurs. L’Annexe B présente
les niveaux de détail auxquels les méthodes fondées sur des mesures peuvent être appliquées.
© ISO 2015 – Tous droits réservés vii
---------------------- Page: 7 ----------------------
NORME INTERNATIONALE ISO 17742:2015(F)
Calcul de l’efficacité énergétique et des économies
d’énergie pour les pays, villes et régions
1 Domaine d’application
La présente Norme internationale fournit une approche globale pour les calculs de l’efficacité
énergétique et des économies d’énergie basés sur des méthodes fondées sur des indicateurs ou fondées
sur des mesures. Elle s’applique aux entités géographiques de type pays, régions et villes.
La présente Norme internationale prend en compte tous les secteurs d’utilisation finale, tels que les
ménages, l’industrie, le tertiaire (services, etc.), l’agriculture et le transport. Elle n’intègre pas le calcul
de l’efficacité et des économies d’énergie dans le secteur de l’approvisionnement énergétique, comme
les centrales électriques, les raffineries et les mines de charbon.
La consommation énergétique n’inclut pas l’énergie intrinsèque, comme les produits pétroliers utilisés
pour la production de plastiques.
La présente Norme internationale n’est pas destinée à être utilisée pour calculer les économies
d’énergie réalisées individuellement par des ménages, des organisations, des entreprises ou d’autres
utilisateurs finaux.
L’énergie provenant de sources d’énergie renouvelables «hors réseau» (par exemple, de panneaux
solaires pour la production d’eau chaude) diminue la quantité d’énergie fournie et peut être intégrée dans
le calcul des économies d’énergie. Il convient que les utilisateurs de la présente Norme internationale
soient conscients que cette énergie hors réseau peut être considérée comme faisant partie de l’énergie
totale issue des sources renouvelables.
2 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
2.1
coefficient d’ajustement
paramètre quantifiable affectant la consommation d’énergie
Note 1 à l’article: Dans la présente Norme internationale, les coefficients d’ajustement utilisés pour les méthodes
fondées sur des indicateurs sont limités aux corrections des variations liées aux conditions météorologiques.
Note 2 à l’article: Dans la présente Norme internationale, les coefficients d’ajustement utilisés pour les méthodes
fondées sur des mesures comprennent les paramètres liés au débit de production, aux conditions météorologiques,
aux horaires d’utilisation, au comportement (température intérieure, intensité lumineuse), etc.
Note 3 à l’article: Les coefficients à un haut niveau d’agrégation qui ont une incidence sur les économies attribuées
aux politiques ou aux programmes (par exemple, l’effet d’aubaine ou l’effet de rebond) ne font pas partie des
coefficients d’ajustement.
[SOURCE: ISO 17743, modifiée — exemples remplacés par des notes.]
2.2
ville
zone géographique sous le contrôle d’une administration municipale
Note 1 à l’article: L’administration municipale relève d’une gouvernance régionale et nationale.
© ISO 2015 – Tous droits réservés 1
---------------------- Page: 8 ----------------------
ISO 17742:2015(F)
2.3
pays
zone géographique sous le contrôle d’un gouvernement national
Note 1 à l’article: Selon la définition de la Division statistique des Nations Unies.
2.4
économies présumées
valeur par défaut des économies d’énergie unitaires, estimée et/ou approuvée par les parties prenantes
Note 1 à l’article: La valeur par défaut peut être basée sur des mesures ou des calculs disponibles.
2.5
indicateur de diffusion
valeur indiquant la pénétration des dispositifs, systèmes ou pratiques d’économie d’énergie
EXEMPLE Nombre de chauffe-eau solaires, d’ampoules basse consommation ou d’appareils électriques de
classe A+ ou A++, fraction du transport de passagers par mode de transport public ou transport de marchandises
par rail et par eau.
2.6
double comptage
prise en compte des économies dues à une combinaison de mesures d’incitation ciblant la même action
d’utilisateur final, comme étant la somme de ce qui serait économisé par chaque mesure individuelle,
lorsque les économies combinées sont inférieures à la somme
Note 1 à l’article: Dans la présente Norme internationale, le double comptage n’est pas valide pour des unités
élémentaires d’action (par exemple, l’effet d’économie d’une isolation et d’une chaudière à haut rendement
énergétique) en cas d’interaction technique.
Note 2 à l’article: Dans la présente Norme internationale, le double comptage est utilisé pour le calcul à des
niveaux d’agrégation élevés (un ensemble de logements par exemple), alors que le terme « effet indirect » peut
être utilisé pour des niveaux d’agrégation plus faibles (par exemple, une entreprise individuelle) dans d’autres
Normes internationales.
[SOURCE: CEN 16212, modifiée — définition adaptée.]
2.7
pilote
quantité supposée influencer de manière prédominante le niveau de consommation énergétique étudié
dans les méthodes fondées sur des indicateurs
Note 1 à l’article: Un pilote peut être une activité (par exemple production), mais aussi une propriété d’un système
(par exemple surface au sol).
2.8
unité élémentaire d’action
entité pour laquelle des économies d’énergie unitaires peuvent être définies et additionnées
Note 1 à l’article: Elle se réfère généralement à un système consommateur d’énergie ou à un participant à un
programme d’économies d’énergie.
2.9
action d’utilisateur final
mesure d’amélioration de l’efficacité énergétique mise en œuvre sur le site d’un utilisateur final
2.10
consommation de référence
référence(s) quantifiée(s) servant de base pour la comparaison de performances énergétiques
Note 1 à l’article: Une consommation de référence reflète généralement une période de temps déterminée.
2 © ISO 2015 – Tous droits réservés
---------------------- Page: 9 ----------------------
ISO 17742:2015(F)
Note 2 à l’article: Une consommation de référence peut être ajustée à l’aide de facteurs ayant une incidence
sur l’usage et/ou la consommation énergétique, tels que le niveau de production, les degrés-jour (température
extérieure), etc.
Note 3 à l’article: En ce qui concerne les performances énergétiques, la définition de la présente Norme
internationale concerne uniquement l’efficacité énergétique.
[SOURCE: ISO/IEC 13273-1, 3.3.10, modifiée — notes adaptées.]
2.11
vecteur énergétique
substance ou phénomène pouvant être utilisé(e) pour produire un travail mécanique ou de la chaleur,
ou pour faire fonctionner un processus
EXEMPLE Électricité, hydrogène et carburants automobiles qui peuvent être utilisés par des systèmes
consommateurs d’énergie
[SOURCE: ISO/IEC 13273-1, 3.1.2, modifiée — sans note.]
2.12
consommation énergétique
quantité d’énergie utilisée
Note 1 à l’article: L’unité de consommation d’énergie peut être exprimée en fonction du vecteur énergétique
concerné, mais aussi dans l’unité standard d’énergie, à savoir le Joule.
[SOURCE: ISO/IEC 13273-1, 3.1.15]
2.13
consommation d’énergie en unités finales
énergie finale où les vecteurs énergétiques sont pris en compte en fonction de leur contenu énergétique
Note 1 à l’article: Les valeurs de contenu énergétique peuvent êtres issues de statistiques énergétiques où elles
sont appliquées pour additionner la consommation énergétique de différents vecteurs énergétiques.
2.14
consommation d’énergie en unités primaires
énergie finale où les vecteurs énergétiques sont pris en compte en fonction de la consommation
d’énergie nécessaire pour les fournir aux utilisateurs finaux
Note 1 à l’article: Par exemple, la consommation d’électricité est multipliée par un facteur de 2,5 lorsque la
conversion des combustibles en électricité a une efficacité de 40 %.
Note 2 à l’article: De cette manière, il est possible de tenir compte du fait que les économies réalisées sur
la consommation d’énergie finale peuvent également réduire les pertes de transformation dans le système
d’approvisionnement énergétique.
2.15
efficacité énergétique
ratio, ou autre relation quantitative, entre une performance, un service, un bien ou une énergie produits
et un apport en énergie
EXEMPLE L’efficacité de conversion d’énergie, le rapport « énergie nécessaire/énergie utilisée », le rapport
« sortie/entrée », le rapport « énergie théoriquement utilisée pour fonctionner/énergie effectivement utilisée
pour fonctionner ».
[SOURCE: ISO/IEC 13273-1, 3.4.1, modifiée — sans note.]
2.16
amélioration de l’efficacité énergétique
accroissement de l’efficacité énergétique résultant de modifications technologiques, de conception,
comportementales et/ou économiques
[SOURCE: ISO/IEC 13273-1, 3.4.3]
© ISO 2015 – Tous droits réservés 3
---------------------- Page: 10 ----------------------
ISO 17742:2015(F)
2.17
action d’amélioration de l’efficacité énergétique
action aboutissant normalement à une amélioration de l’efficacité énergétique pouvant être vérifiée,
mesurée ou évaluée
Note 1 à l’article: La mesure concerne à la fois l’action d’utilisateur final et la mesure d’incitation.
2.18
utilisateur final de l’énergie
personne, groupe de personnes ou organisme ayant la responsabilité du fonctionnement d’un système
consommateur d’énergie
Note 1 à l’article: L’utilisateur final de l’énergie peut différer du client qui peut acheter de l’énergie sans
forcément l’utiliser.
[SOURCE: ISO/IEC 13273-1, 3.1.12]
2.19
économies d’énergie
réduction de la consommation énergétique par rapport à une consommation de référence
Note 1 à l’article: L’économie d’énergie peut être effective ou attendue.
Note 2 à l’article: L’économie d’énergie peut être le résultat de la mise en œuvre d’une ou de plusieurs actions ou
d’une amélioration autonome.
[SOURCE: ISO/IEC 13273-1, 3.3.11, dernière partie de la définition et notes adaptées]
2.20
usage énergétique
mode ou type d’utilisation de l’énergie
Note 1 à l’article: Les caractéristiques de l’usage énergétique comprennent, entre autres, l’objectif de l’usage, le
choix de la ou des sources et la mise en œuvre.
[SOURCE: ISO/IEC 13273-1, 3.1.14]
2.21
système consommateur d’énergie
système physique ayant un périmètre défini et qui consomme de l’énergie
Note 1 à l’article: Un système consommateur d’énergie peut être une ou plusieurs installations, procédés, parties
d’un procédé, bâtiments, parties d’un bâtiment, machines, équipements, produits, etc.
[SOURCE: ISO/IEC 13273-1, 3.1.11]
2.22
mesure d’incitation
service d’efficacité énergétique ou programme d’amélioration proposé à un utilisateur final de l’énergie
Note 1 à l’article: Une mesure d’incitation est offerte par un acteur qui n’est pas l’utilisateur final de l’énergie.
EXEMPLE Un programme de subvention pour l’isolation de logements ou un label pour l’efficacité des appareils.
2.23
contenu énergétique des intrants
énergie présente dans les intrants et qui n’est pas utilisée à des fins énergétiques
EXEMPLE Pétrole pour la production de matières plastiques et gaz naturel pour la production d’engrais.
[SOURCE: ISO/IEC 13273-1, 3.1.3, modifiée — exemple adapté.]
4 © ISO 2015 – Tous droits réservés
---------------------- Page: 11 ----------------------
ISO 17742:2015(F)
2.24
énergie finale
énergie telle que fournie à un système consommateur d’énergie
Note 1 à l’article: Ce concept est parfois désigné sous le terme «énergie fournie».
[SOURCE: ISO/IEC 13273-1, 3.1.13]
2.25
effet d’aubaine
mise à disposition d’incitations financières pour la réalisation de mesures d’économies à destination
d’utilisateurs finaux qui auraient de toute façon réalisé ces mesures
EXEMPLE Économies issues de subventions ou de crédits d’impôt destinés à des utilisateurs finaux qui
auraient de toute façon réalisé les mesures.
Note 1 à l’article: L’effet d’aubaine peut être estimé, par exemple, grâce à une comparaison avec les économies
d’énergie réalisées dans des circonstances similaires mais sans programme de subvention.
2.26
économies d’énergie brutes
économies d’énergie utilisant des coefficients d’ajustement, à l’exception des corrections pour double
comptage, effet multiplicateur, effet d’aubaine et effet de rebond
Note 1 à l’article: Les économies d’énergie brutes comprennent les coefficients d’ajustement mentionnés en 3.1.
2.27
méthode fondée sur des indicateurs
détermination des économies d’énergie à partir de la variation d’indicateurs de consommation d’énergie
sur une certaine période
EXEMPLE Pour l’industrie, une baisse de la consommation d’énergie par tonne d’acier constitue une
économie d’énergie.
2.28
économies basées sur des indicateurs
économies d’énergie calculées avec des méthodes fondées sur des indicateurs
2.29
méthode fondée sur des mesures
détermination des économies d’énergie issues d’actions d’utilisateur final à l’aide d’économies d’énergie
unitaires et d’unités élémentaires d’action
Note 1 à l’article: Si les actions d’utilisation finale sont dues à des mesures d’incitation, notamment d’ordre
politique, les méthodes fondées sur des mesures imputent les économies à la politique.
EXEMPLE Dans le cadre d’un programme de subvention de chaudières pour les ménages, les économies sont
calculées à partir des économies moyennes réalisées par chaudière (comparées à une chaudière de référence
définie) multipliées par le nombre de chaudières subventionnées (en appliquant une correction pour les
utilisateurs profitant de l’effet d’aubaine et qui auraient de toute façon installé une chaudière plus eff
...
Questions, Comments and Discussion