Measurement of radioactivity in the environment — Air: radon-222 — Part 8: Methodologies for initial and additional investigations in buildings

This document specifies requirements for the determination of the activity concentration of radon in all types of buildings. The buildings can be single family houses, public buildings, industrial buildings, underground buildings, etc. This document describes the measurement methods used to assess, during the initial investigation phase, the average annual activity concentration of radon in buildings. It also deals with investigations needed to identify the source, entry routes and transfer pathways of the radon in the building (additional investigations). Finally, this document outlines the applicable requirements for the immediate post‑mitigation testing of the implemented mitigation techniques, monitoring of their effectiveness and testing of the sustainability of the building's behaviour towards radon. This document does not address the technical building diagnostic or the prescription of mitigation work.

Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 8: Méthodologies appliquées aux investigations initiales et complémentaires dans les bâtiments

Le présent document spécifie les exigences applicables à la détermination de l'activité volumique du radon dans tout type de bâtiment (habitations privées, bâtiments publics, bâtiments industriels, bâtiments souterrains, etc.). Le présent document décrit les méthodes de mesure utilisées pour évaluer, lors de la phase de dépistage, l'activité volumique moyenne annuelle du radon dans les bâtiments. Le présent document expose les actions à entreprendre pour identifier la source, les voies d'entrée et de transfert du radon dans le bâtiment (investigations complémentaires). Pour finir, le présent document développe les exigences applicables à la vérification immédiate des techniques de remédiation mises en œuvre, au contrôle de leur efficacité ainsi qu'à la vérification de la pérennité de la situation du bâtiment vis-à-vis du radon. Le présent document ne traite ni du diagnostic technique ni de la spécification de travaux de remédiation.

General Information

Status
Published
Publication Date
09-Dec-2019
Current Stage
6060 - International Standard published
Start Date
10-Dec-2019
Due Date
01-Dec-2019
Completion Date
10-Dec-2019
Ref Project

Relations

Buy Standard

Standard
ISO 11665-8:2019 - Measurement of radioactivity in the environment -- Air: radon-222
English language
19 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11665-8:2019 - Mesurage de la radioactivité dans l'environnement -- Air: radon 222
French language
20 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 11665-8
Second edition
2019-12
Measurement of radioactivity in the
environment — Air: radon-222 —
Part 8:
Methodologies for initial and
additional investigations in buildings
Mesurage de la radioactivité dans l'environnement — Air: radon 222 —
Partie 8: Méthodologies appliquées aux investigations initiales et
complémentaires dans les bâtiments
Reference number
ISO 11665-8:2019(E)
©
ISO 2019

---------------------- Page: 1 ----------------------
ISO 11665-8:2019(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 11665-8:2019(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 3
4 Organization of the measuring stages . 4
5 Initial investigations . 4
5.1 Objective . 4
5.2 Methodology followed during the initial investigation . 4
5.3 Selection of measuring devices . 5
5.4 Location of the measuring points . 5
5.4.1 General. 5
5.4.2 Determination and selection of the homogeneous zones . 5
5.4.3 Number of measuring devices to be installed . 6
5.4.4 Installation of measuring devices . 6
5.5 Installation and removal of the measuring devices . 6
5.6 Processing of the measuring devices . 7
5.7 Data analysis . 7
5.8 Initial investigation report . 8
6 Additional investigations . 8
6.1 General . 8
6.2 Methodology for additional investigations . 9
6.2.1 General. 9
6.2.2 Building mapping . 9
6.2.3 Identification of radon sources and entry routes . 9
6.2.4 Identification of transfer pathways .10
6.3 Report of additional investigations .11
7 Immediate post-mitigation testing of the technical solutions applied .12
8 Control of the effectiveness of the technical solutions applied .12
9 Control of the sustainability .12
Annex A (informative) Examples of underground buildings and buried levels .13
Annex B (informative) Organization of radon measuring phases in a building .14
Annex C (informative) Initial investigation report .15
Annex D (informative) Example of analysis of initial investigation measurement results .17
Bibliography .18
© ISO 2019 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 11665-8:2019(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/ iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies,
and radiological protection, Subcommittee SC 2, Radiological protection.
This second edition cancels and replaces the first edition (ISO 11665-8:2012), of which it constitutes a
minor revision. The changes compared to the previous edition are as follows:
— update of the Introduction;
— update of the Bibliography.
A list of all the parts in the ISO 11665 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html .
iv © ISO 2019 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 11665-8:2019(E)

Introduction
Radon isotopes 222, 219 and 220 are radioactive gases produced by the disintegration of radium
isotopes 226, 223 and 224, which are decay products of uranium-238, uranium-235 and thorium-232
respectively, and are all found in the earth's crust (see Annex A of ISO 11665-1:2019 for further
information). Solid elements, also radioactive, followed by stable lead are produced by radon
[1]
disintegration .
When disintegrating, radon emits alpha particles and generates solid decay products, which are also
radioactive (polonium, bismuth, lead, etc.). The potential effects on human health of radon lie in its solid
decay products rather than the gas itself. Whether or not they are attached to atmospheric aerosols,
radon decay products can be inhaled and deposited in the bronchopulmonary tree to varying depths
[2][3][4][5]
according to their size .
[6]
Radon is today considered to be the main source of human exposure to natural radiation. UNSCEAR
suggests that, at the worldwide level, radon accounts for around 52 % of global average exposure to
natural radiation. The radiological impact of isotope 222 (48 %) is far more significant than isotope 220
(4 %), while isotope 219 is considered negligible (see Annex A of ISO 11665-1:2019). For this reason,
references to radon in this document refer only to radon-222.
Radon activity concentration can vary from one to more orders of magnitude over time and space.
Exposure to radon and its decay products varies tremendously from one area to another, as it depends
on the amount of radon emitted by the soil and building materials, weather conditions, and on the
degree of containment in the areas where individuals are exposed.
As radon tends to concentrate in enclosed spaces like houses, the main part of the population exposure
is due to indoor radon. Soil gas is recognized as the most important source of residential radon through
infiltration pathways. Other sources are described in other parts of ISO 11665 and ISO 13164 series for
[7]
water .
Radon enters into buildings via diffusion mechanism caused by the all-time existing difference between
radon activity concentrations in the underlying soil and inside the building, and via convection
mechanism inconstantly generated by a difference in pressure between the air in the building and the
air contained in the underlying soil. Indoor radon activity concentration depends on radon activity
concentration in the underlying soil, the building structure, the equipment (chimney, ventilation
systems, among others), the environmental parameters of the building (temperature, pressure, etc.)
and the occupants’ lifestyle.
-3
To limit the risk to individuals, a national reference level of 100 Bq·m is recommended by the World
[5] -3
Health Organization . Wherever this is not possible, this reference level should not exceed 300 Bq·m .
This recommendation was endorsed by the European Community Member States that should establish
national reference levels for indoor radon activity concentrations. The reference levels for the annual
-3[5]
average activity concentration in air should not be higher than 300 Bq·m .
To reduce the risk to the overall population, building codes should be implemented that require radon
prevention measures in buildings under construction and radon mitigating measures in existing
buildings. Radon measurements are needed because building codes alone cannot guarantee that radon
concentrations are below the reference level.
The assessment of the radon activity concentration of the atmosphere in a building is based on a step-by-
step procedure with two measuring stages: the initial investigation, to estimate the annual average
value of the radon activity concentration in the building, and, when needed, additional investigations.
When it is decided that the radon activity concentration in a building has to be reduced, mitigation
[8][9][10].
techniques are adapted to each individual case The impact of the mitigation is assessed using
new radon measurements in the building.
NOTE The origin of radon-222 and its short-lived decay products in the atmospheric environment are
described generally in ISO 11665-1 together with measurement methods.
© ISO 2019 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 11665-8:2019(E)
Measurement of radioactivity in the environment — Air:
radon-222 —
Part 8:
Methodologies for initial and additional investigations in
buildings
1 Scope
This document specifies requirements for the determination of the activity concentration of radon in
all types of buildings. The buildings can be single family houses, public buildings, industrial buildings,
underground buildings, etc.
This document describes the measurement methods used to assess, during the initial investigation
phase, the average annual activity concentration of radon in buildings. It also deals with investigations
needed to identify the source, entry routes and transfer pathways of the radon in the building (additional
investigations).
Finally, this document outlines the applicable requirements for the immediate post-mitigation
testing of the implemented mitigation techniques, monitoring of their effectiveness and testing of the
sustainability of the building's behaviour towards radon.
This document does not address the technical building diagnostic or the prescription of mitigation work.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 6707-1, Building and civil engineering — Vocabulary — Part 1: General terms
ISO 11665-1, Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of radon
and its short-lived decay products and associated measurement methods
ISO 11665-4, Measurement of radioactivity in the environment — Air: Radon 222 — Part 4: Integrated
measurement methods for determining average activity concentration using passive sampling and delayed
analysis
ISO 11665-7, Measurement of radioactivity in the environment — Air: radon-222 — Part 7: Accumulation
method for estimating surface exhalation rate
3 Terms, definitions and symbols
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11665-1 and ISO 6707-1 and
the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at http:// www .iso .org/ obp
© ISO 2019 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 11665-8:2019(E)

— IEC Electropedia: available at http:// www .electropedia .org/
3.1.1
additional investigations
stage of actions, including measurements, when identifying the sources of radon and its entry routes
and transfer pathways in a building
3.1.2
building
anything that is constructed or results from construction operations, usually partially or totally
enclosed and designed to stand permanently in one place, and whose main purpose is to provide shelter
for its occupants and contents
Note 1 to entry: In this document, a building is considered as underground if its roof is partly or entirely
underground (see Figure A.1).
Note 2 to entry: The buried levels of a building are those with their ceiling entirely below the ground level
(see Figure A.2).
3.1.3
building mapping
spatial presentation of measurement results showing the distribution of radon activity concentration
data in the different spaces of the building in order to identify those where radon activity concentration
is the highest
Note 1 to entry: The measurements carried out for the building mapping are representative of the prevailing
conditions at the time of sampling and thus cannot be used to establish the annual average activity concentrations.
3.1.4
homogeneous zone
zone including one or more adjacent volumes inside the building that share identical or very close
characteristics (type of walls, floors, basement, foundations, building level, water supply, water usage
patterns, ventilation, openings, temperature, etc.) with a homogeneous activity concentration of radon
Note 1 to entry: A homogeneous zone is defined based on the following main criteria:
— same type of soil-building interface;
— same ventilation conditions (no ventilation system, natural ventilation, mechanical ventilation, etc.);
— same temperature level.
Note 2 to entry: In cases where water can be a potential source of radon, the following additional criteria apply:
— same mode of water supply (direct, indirect, continuous, recycled);
— same type of water usage patterns (washing, showering, therapeutic care).
3.1.5
initial investigation
first stage of actions, including measurements, when determining the annual average activity
concentration of radon in a building
3.1.6
mitigation techniques
technical means implemented in an existing building in order to reduce the activity concentration of radon
3.1.7
occupied volume
volume regularly occupied with a residence time justifying an interest with regard to the radon
exposure risk
EXAMPLE Living-room, workshop, office, classroom, etc.
2 © ISO 2019 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 11665-8:2019(E)

3.1.8
radon entry routes
passages and vectors (air or water) that permit radon to penetrate the building
Note 1 to entry: Radon does not enter uniformly across the entire envelope of the building. The preferred entry
routes are cracks in the soil-building interface, piping runs, etc.
3.1.9
radon source
origin of radon present in the building
Note 1 to entry: The main source of radon in buildings is usually the underlying soil. In some cases, building
materials, the outdoor air, water (inflow water, supply water, thermal water, etc.) and even city gas are additional
sources that can increase the radon activity concentration.
3.1.10
radon transfer pathways
passages and vectors (air or water) that permit radon to move from one volume in the building to another
Note 1 to entry: Radon transfer pathways commonly include piping runs, staircases, doorways, etc.
3.1.11
soil-building interface
contact surface between the soil and the building
Note 1 to entry: The soil-building interface can, for example, be formed by:
— a beaten-earth floor;
— an earthen floor;
— a slab or floor on a crawl space, technical space, basement or cellar;
— buried or semi-buried walls in contact with the ground;
— etc.
3.1.12
technical building diagnostic
investigation operations conducted to identify the causes of the presence of radon detected in a building
during the initial investigation, and to provide the data and information needed to choose appropriate
long-lasting mitigation techniques
3.1.13
value of interest
pre-fixed value of the annual average radon activity concentration, from which actions shall be taken to
[11]
reduce the annual average activity concentration in a building
Note 1 to entry: The values of interest, also referred to as reference levels, are fixed by regulations issued by the
competent administrative national authority or agreed contractually by the parties involved.
3.1.14
volume
closed space in a building
EXAMPLE Room, corridor, box room, workshop, office, classroom, crawl space, cellar, etc.
3.2 Symbols
For the purposes of this document, the symbols given in ISO 11665-1 and the following apply.
© ISO 2019 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 11665-8:2019(E)

C average annual radon activity concentration, in becquerels per cubic metre
C value of interest of the radon activity concentration, in becquerels per cubic metre
I
4 Organization of the measuring stages
The assessment of the radon activity concentration of the atmosphere in a building is based on a step-
by-step procedure with different measuring stages:
— The presence of radon in a building shall be demonstrated through an initial investigation
in accordance with the requirements described in Clause 5. The aim of this stage is to obtain
measurement data with which to assess the annual average activity concentration of radon that is
compared to the value of interest.
— If the initial investigation demonstrates that the radon activity concentration is lower than any values
of interest, the sustainability of the building's behaviour towards radon is monitored in accordance
with the requirements set out in Clause 9. If changes in the building can alter its sustainability,
the initial investigation shall be performed again in accordance with the requirements set out in
Clause 5.
— If the initial investigation demonstrates that the radon activity concentration is higher than
any values of interest, investigations shall be performed in order to identify the causes of the
presence of radon at this level in the building (technical building diagnostic, etc.). Depending on
the type of building involved, and particularly for large-footprint buildings with complex structure
configurations, additional investigations may be carried out to help identify the sources of radon
(soil, building materials and water) and its entry routes and transfer pathways in the building.
These additional investigations shall be carried out in accordance with the requirements set out
in Clause 6.
— If mitigation techniques (simple actions such as power on ventilation, building works, etc.) are
implemented, immediate post-mitigation testing may be performed using short-term radon
measurements that are not representative of the annual average value (see Clause 7). The
effectiveness and the sustainability of these mitigation techniques shall be monitored in accordance
with the requirements set out in Clauses 8 and 9.
NOTE An example of the organization of the different stages is given in Annex B.
5 Initial investigations
5.1 Objective
The aim of the initial investigation is to determine whether a building or part of a building shows an
annual average value of radon activity concentration above any values of interest.
5.2 Methodology followed during the initial investigation
The initial investigation shall be performed following the time sequence described below:
— selection of measuring devices;
— location of the measuring points in the building;
— installation and removal of measuring devices;
— processing of measuring devices;
— data analysis of measurement results obtained for each homogeneous zone;
4 © ISO 2019 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 11665-8:2019(E)

— initial investigation report drafting.
5.3 Selection of measuring devices
The measurement method used to approximate the annual average activity concentration shall be the
long-term integrated measurement method in accordance with ISO 11665-4.
Several types of measuring device complying with the requirements of ISO 11665-4 may be used
during the initial investigation. However, to facilitate the data analysis and the interpretation of the
measurement results, the same type of measuring device shall be used per building.
For a specific atmosphere with a high variable equilibrium factor (dusty atmosphere, high humidity,
highly ventilated, etc.), a passive measuring device in so-called “closed configuration” shall be used.
5.4 Location of the measuring points
5.4.1 General
The installation of the measuring devices follows a three-stage protocol which determines:
— the homogeneous zones in the building under investigation;
— the number of devices per homogeneous zone required to take the representative measurements;
— the locations of the measuring points in the homogeneous zones.
5.4.2 Determination and selection of the homogeneous zones
Homogeneous zones are determined from the lowest floor upwards in order to progressively select a total
surface of occupied homogeneous zone that is at least equal to the ground level area of the building. This
approach is expected to select the homogeneous zones with the highest activity concentration of radon.
This approach is performed following two steps:
— the determination of homogeneous zones is based on:
— the following main criteria:
— same type of soil-building interface;
— same ventilation conditions (no ventilation system, natural ventilation, mechanical
ventilation, etc.);
— same temperature level;
— the following additional criteria when water can be a potential source of radon:
— same mode of water supply (direct, indirect, continuous, recycled);
— same type of water usage patterns (washing, showering, therapeutic care);
— the selection of homogeneous zones shall comprise at least one occupied room.
In specific cases where specific sources other than soil (water and/or building materials) have been
identified, this approach is performed for each building floor concerned.
For buried levels of a building, this approach is performed for each floor that is below ground-level, and
each homogeneous zone that is occupied is selected.
For underground buildings, this approach is performed for each building floor.
© ISO 2019 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 11665-8:2019(E)

In the case of large buildings or buildings with a complex structure, the determination of the
homogeneous zones requires a visit to these premises.
In the case of single family houses, the determination of the homogeneous zones is usually simple as
each floor constitutes a homogeneous zone.
5.4.3 Number of measuring devices to be installed
At least one measuring device shall be installed in each selected homogeneous zone, with a minimum of
two devices per building.
2
In the case of large homogeneous zones, one device is installed for every 200 m .
5.4.4 Installation of measuring devices
The measuring device(s) shall be installed in an occupied volume of the building for each selected
homogeneous zone. Areas not representative of the exposure conditions shall be avoided, particularly
entrances, cellars, garages, pathways and attics.
The use of the premises shall dictate the choice of location. Normal conditions of use and occupation of
the premises shall not be altered during the measurement.
The measuring device shall be placed on a free surface between 1 m and 2 m above the ground, under
the following conditions:
— the chosen position is selected with a free space consistent with the detection volume of the
measuring device to ensure a measurement representative of the atmosphere of the homogeneous
zone; if the walls are made of building materials with a high content of thorium, a free space of at
least 20 cm shall be left around the sensor to avoid the influence of the thoron's exhalation from the
[8]
walls ;
— the measuring device shall be placed away from:
— a source of heat (radiator, chimney, electrical equipment, television, direct sunlight, etc.);
— a
...

NORME ISO
INTERNATIONALE 11665-8
Deuxième édition
2019-12
Mesurage de la radioactivité dans
l'environnement — Air: radon 222 —
Partie 8:
Méthodologies appliquées
aux investigations initiales et
complémentaires dans les bâtiments
Measurement of radioactivity in the environment — Air:
radon-222 —
Part 8: Methodologies for initial and additional investigations in
buildings
Numéro de référence
ISO 11665-8:2019(F)
©
ISO 2019

---------------------- Page: 1 ----------------------
ISO 11665-8:2019(F)

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 11665-8:2019(F)

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.2 Symboles . 4
4 Organisation des phases de mesure . 4
5 Dépistage . 5
5.1 Objectif . 5
5.2 Méthodologie suivie lors du dépistage . 5
5.3 Choix des dispositifs de mesure . 5
5.4 Implantation des points de mesure . 5
5.4.1 Généralités . 5
5.4.2 Détermination et sélection des zones homogènes . 5
5.4.3 Nombre de dispositifs de mesure à installer . 6
5.4.4 Implantation des dispositifs de mesure . 6
5.5 Pose et dépose des dispositifs de mesure . 7
5.6 Traitement des dispositifs de mesure . 7
5.7 Analyse des données . 7
5.8 Rapport de dépistage . 8
6 Investigations complémentaires . 9
6.1 Généralités . 9
6.2 Méthodologie des investigations complémentaires . 9
6.2.1 Généralités . 9
6.2.2 Cartographie du bâtiment .10
6.2.3 Identification des sources et des voies d’entrée du radon.10
6.2.4 Identification des voies de transfert .11
6.3 Rapport d’investigations complémentaires .12
7 Vérification immédiate de l’efficacité des solutions techniques mises en œuvre .12
8 Contrôle de l’efficacité des solutions techniques appliquées .13
9 Contrôle de pérennité .13
Annexe A (informative) Exemples de bâtiments souterrains et de niveaux enterrés .14
Annexe B (informative) Organisation des phases de mesure du radon dans un bâtiment .15
Annexe C (informative) Rapport de dépistage .16
Annexe D (informative) Exemple d’analyse des résultats de mesure du dépistage .18
Bibliographie .19
© ISO 2019 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 11665-8:2019(F)

Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes
nationaux de normalisation (comités membres de l'ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l'ISO participent également aux travaux.
L'ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/ brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, de la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute autre information au sujet de
l’adhésion de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les
obstacles techniques au commerce (OTC), voir le lien suivant: www .iso .org/ iso/ fr/ avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC 85, Énergie nucléaire, technologies
nucléaires, et radioprotection, sous-comité SC 2, Radioprotection.
Cette deuxième édition annule et remplace la première édition (ISO 11665-8:2012), qui a fait l’objet
d’une révision technique. Les modifications par rapport à l’édition précédente sont les suivantes:
— mise à jour de l’introduction;
— mise à jour de la bibliographie.
Une liste de toutes les parties de la série ISO 11665 est disponible sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/ fr/ members .html.
iv © ISO 2019 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 11665-8:2019(F)

Introduction
Les isotopes 222, 219 et 220 du radon sont des gaz radioactifs produits par la désintégration des
isotopes 226, 223 et 224 du radium, lesquels sont respectivement des descendants de l’uranium 238,
de l’uranium 235 et du thorium 232, et sont tous présents dans l’écorce terrestre (voir Annexe A de
l’ISO 11665-1:2019 pour plus d’informations). Des éléments solides, eux aussi radioactifs, suivis par du
[1]
plomb stable, sont produits par la désintégration du radon .
Lorsqu’il se désintègre, le radon émet des particules alpha et génère des descendants solides qui sont
eux aussi radioactifs (par exemple polonium, bismuth, plomb, etc.). Les effets potentiels du radon sur
la santé humaine sont liés à ses descendants solides plutôt qu’au gaz lui-même. Qu’ils soient ou non
attachés à des aérosols atmosphériques, les descendants du radon peuvent être inhalés et déposés dans
[2][3][4][5]
l’arbre broncho-pulmonaire à différentes profondeurs, suivant leur taille .
Le radon est aujourd’hui considéré comme la principale source d’exposition de l’homme au rayonnement
[6]
naturel. L’UNSCEAR suggère qu’au niveau mondial, le radon intervient pour environ 52 % de
l’exposition moyenne globale au rayonnement naturel. L’impact radiologique de l’isotope 222 (48 %) est
nettement plus important que celui de l’isotope 220 (4 %), l’isotope 219 est quant à lui considéré comme
négligeable (voir Annexe A de l’ISO 11665-1:2019). Pour cette raison, les références au radon dans le
présent document désignent exclusivement le radon 222.
L’activité volumique du radon peut varier d’un à plusieurs ordres de grandeur dans le temps et l’espace.
L’exposition au radon et à ses descendants varie considérablement d’un lieu à l’autre. Elle dépend de
la quantité de radon émise par le sol et des matériaux de construction en ces lieux, des conditions
météorologiques et du degré de confinement dans les lieux où sont exposées les personnes.
Comme le radon a tendance à se concentrer dans les espaces clos tels que les maisons, la majeure partie
de l’exposition de la population provient du radon présent dans l’atmosphère intérieure des bâtiments.
Le gaz issu du sol est considéré comme la source la plus importante de radon résidentiel via des voies
d’infiltration. D’autres sources sont décrites dans d’autres parties de l’ISO 11665 et dans la série
[7]
ISO 13164 pour l’eau .
Le radon pénètre dans les bâtiments par un mécanisme de diffusion dû à la différence permanente
entre l’activité volumique du radon dans le sol sous-jacent et celle existant à l’intérieur du bâtiment,
et par un mécanisme de convection généré par intermittence par une différence de pression entre l’air
dans le bâtiment et celui contenu dans le sol sous-jacent. L’activité volumique du radon à l’intérieur des
bâtiments dépend de l’activité volumique du radon dans le sol sous-jacent, de la structure du bâtiment,
des équipements (cheminée, systèmes de ventilation mécanique, entre autres), des paramètres
environnementaux du bâtiment (température, pression, etc.), mais également du mode de vie de ses
occupants.
–3
Pour limiter le risque pour les individus, un niveau de référence national de 100 Bq·m est recommandé
[5]
par l’Organisation mondiale de la santé . Lorsque cela n’est pas possible, il convient que ce niveau de
−3
référence ne dépasse pas 300 Bq·m . Cette recommandation a été entérinée par les États membres de
la Communauté européenne qui doivent établir des niveaux de référence nationaux pour les activités
volumiques du radon à l’intérieur des bâtiments. Il convient que les niveaux de référence pour l’activité
-3[5]
volumique moyenne annuelle dans l’air ne soient pas supérieurs à 300 Bq·m .
Pour réduire le risque pour l’ensemble de la population, il convient de mettre en œuvre des codes de
construction qui exigent des mesures de prévention du radon dans les bâtiments en construction
et des mesures de remédiation du radon dans les bâtiments existants. Les mesurages du radon sont
nécessaires, car les codes de construction ne peuvent à eux seuls garantir que les concentrations de
radon sont inférieures au niveau de référence.
La détermination de l’activité volumique du radon dans l’atmosphère d’un bâtiment s’appuie sur une
procédure méthodique comprenant deux phases de mesure: les investigations initiales (le dépistage),
permettant d’estimer la valeur moyenne annuelle de l’activité volumique du radon dans le bâtiment; et
si nécessaire, des investigations complémentaires.
© ISO 2019 – Tous droits réservés v

---------------------- Page: 5 ----------------------
ISO 11665-8:2019(F)

Lorsque l’activité volumique du radon doit être réduite dans un bâtiment, les techniques de remédiation
[8][9][10]
sont adaptées à chaque cas particulier . On vérifie l’impact de la remédiation par de nouveaux
mesurages du radon dans le bâtiment.
NOTE L’origine du radon 222 et de ses descendants à vie courte dans l’environnement atmosphérique ainsi
que les méthodes de mesure sont décrites de manière générale dans l’ISO 11665-1.
vi © ISO 2019 – Tous droits réservés

---------------------- Page: 6 ----------------------
NORME INTERNATIONALE ISO 11665-8:2019(F)
Mesurage de la radioactivité dans l'environnement — Air:
radon 222 —
Partie 8:
Méthodologies appliquées aux investigations initiales et
complémentaires dans les bâtiments
1 Domaine d’application
Le présent document spécifie les exigences applicables à la détermination de l’activité volumique du
radon dans tout type de bâtiment (habitations privées, bâtiments publics, bâtiments industriels,
bâtiments souterrains, etc.).
Le présent document décrit les méthodes de mesure utilisées pour évaluer, lors de la phase de dépistage,
l’activité volumique moyenne annuelle du radon dans les bâtiments. Le présent document expose les
actions à entreprendre pour identifier la source, les voies d’entrée et de transfert du radon dans le
bâtiment (investigations complémentaires).
Pour finir, le présent document développe les exigences applicables à la vérification immédiate des
techniques de remédiation mises en œuvre, au contrôle de leur efficacité ainsi qu’à la vérification de la
pérennité de la situation du bâtiment vis-à-vis du radon.
Le présent document ne traite ni du diagnostic technique ni de la spécification de travaux de
remédiation.
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
ISO 6707-1, Bâtiments et ouvrages de génie civil — Vocabulaire — Partie 1: Termes généraux
ISO 11665-1, Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 1: Origine du
radon et de ses descendants à vie courte, et méthodes de mesure associées
ISO 11665-4, Mesurage de la radioactivité dans l’environnement — Air: radon 222 — Partie 4: Méthode
de mesure intégrée pour la détermination de l’activité volumique moyenne du radon avec un prélèvement
passif et une analyse en différé
ISO 11665-7, Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 7: Méthode
d'estimation du flux surfacique d'exhalation par la méthode d'accumulation
3 Termes, définitions et symboles
3.1 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 11665-1 et
l’ISO 6707-1, ainsi que les suivants s’appliquent.
© ISO 2019 – Tous droits réservés 1

---------------------- Page: 7 ----------------------
ISO 11665-8:2019(F)

L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
— IEC Electropedia: disponible à l’adresse http:// www .electropedia .org/
3.1.1
investigations complémentaires
phase de réalisation de mesurages permettant d’aider à l’identification des sources de radon, de leurs
voies d’entrée et de leurs voies de transfert dans le bâtiment
3.1.2
bâtiment
tout ce qui est construit ou résulte d’opérations de construction, généralement partiellement ou
totalement fermé et conçu pour rester en permanence au même endroit, et dont la finalité principale est
d’abriter des occupants ou des contenus
Note 1 à l'article: Dans le présent document, un bâtiment est considéré comme souterrain si son toit se situe
partiellement ou entièrement sous terre (voir Figure A.1).
Note 2 à l'article: Les niveaux enterrés d’un bâtiment sont ceux dont le plafond se situe entièrement en dessous
du niveau du sol (voir Figure A.2).
3.1.3
cartographie du bâtiment
représentation spatiale des résultats de mesure indiquant la répartition de l’activité volumique
du radon dans les différents volumes du bâtiment afin d’identifier les zones qui présentent l’activité
volumique la plus importante
Note 1 à l'article: Les mesurages réalisés pour la cartographie du bâtiment ne sont représentatifs que des
conditions rencontrées au moment du prélèvement et ne peuvent pas donc pas être utilisés pour estimer l’activité
volumique moyenne annuelle.
3.1.4
zone homogène
zone qui comporte un ou plusieurs volumes contigus à l’intérieur d’un bâtiment et dont les
caractéristiques sont identiques ou très proches (nature des murs, du sol, du sous-sol, des fondations,
niveau du bâtiment, alimentation en eau, type d’utilisation de l’eau, ventilation, ouvertures, température,
etc.) avec une activité volumique du radon homogène
Note 1 à l'article: Une zone homogène se définit principalement sur la base des critères suivants:
— même type d’interface sol-bâtiment;
— mêmes conditions de ventilation (pas de système de ventilation, ventilation naturelle, ventilation
mécanique, etc.);
— même niveau de température.
Note 2 à l'article: Lorsque l’eau peut être une source potentielle de radon, les critères supplémentaires suivants
s’appliquent:
— même mode d’alimentation en eau (direct, indirect, continu, recyclé);
— même type d’utilisation de l’eau (lavage, douche, soins thérapeutiques).
3.1.5
investigations initiales ou dépistage
première étape du processus, y compris le mesurage, visant à déterminer les valeurs moyennes
annuelles de l’activité volumique du radon dans un bâtiment
2 © ISO 2019 – Tous droits réservés

---------------------- Page: 8 ----------------------
ISO 11665-8:2019(F)

3.1.6
techniques de remédiation
moyens techniques mis en œuvre dans un bâtiment existant afin de réduire l’activité volumique du radon
3.1.7
volume occupé
volume régulièrement occupé avec un temps de présence justifiant une vigilance vis-à-vis du risque
d’exposition au radon
EXEMPLE Salle à manger, atelier, bureau, salle de classe, etc.
3.1.8
voies d’entrée du radon
passages empruntés ou vecteurs utilisés (air ou eau) par le radon pour pénétrer dans le bâtiment
Note 1 à l'article: L’entrée du radon dans un bâtiment ne se fait pas de façon uniforme sur toute l’enveloppe du
bâtiment. Les voies d’entrée privilégiées du radon sont les fissures dans l’interface sol-bâtiment, les passages de
canalisation, etc.
3.1.9
source du radon
origine de la présence du radon dans le bâtiment
Note 1 à l'article: Dans les bâtiments, la principale source du radon est en général le sol sous-jacent. Dans certains
cas, les matériaux de construction, l’air extérieur, l’eau (de captage, de distribution, thermale, etc.) et même le gaz
de ville peuvent participer à l’augmentation de l’activité volumique du radon.
3.1.10
voies de transfert du radon
passages empruntés ou vecteurs utilisés (air ou eau) par le radon pour se déplacer d’un volume à un
autre dans le bâtiment
Note 1 à l'article: Les voies de transfert du radon sont généralement les passages de canalisation, les escaliers, les
portes, etc.
3.1.11
interface sol-bâtiment
surface de contact entre le sol et le bâtiment
Note 1 à l'article: L’interface sol-bâtiment peut par exemple être constituée de:
— sol en terre battue;
— dallage sur terre-plein;
— dalle ou plancher sur un vide technique, vide sanitaire, sous-sol ou cave;
— murs enterrés ou semi-enterrés en contact avec le terrain;
— etc.
3.1.12
diagnostic technique du bâtiment
opérations d’investigation réalisées pour identifier les causes de la présence de radon détecté dans
le bâtiment lors du dépistage et pour fournir les éléments nécessaires au choix de techniques de
remédiation pérennes adaptées
© ISO 2019 – Tous droits réservés 3

---------------------- Page: 9 ----------------------
ISO 11665-8:2019(F)

3.1.13
valeur d’intérêt
valeur préalablement fixée de l’activité volumique moyenne annuelle du radon à partir de laquelle des
[11]
actions doivent être entreprises pour abaisser cette activité volumique moyenne annuelle
Note 1 à l'article: Les valeurs d’intérêt, également nommées niveaux de référence, sont fixées réglementairement
par l’Autorité administrative nationale compétente ou convenues contractuellement entre les parties impliquées.
3.1.14
volume
espace fermé dans un bâtiment
EXEMPLE Pièce de vie, couloir, débarras, atelier, bureau, salle de classe, vide sanitaire, cave, etc.
3.2 Symboles
Pour les besoins du présent document, les symboles donnés dans l'ISO 11665-1 ainsi que les suivants,
s’appliquent.
C activité volumique annuelle moyenne, en becquerels par mètre cube
C valeur d’intérêt de l’activité volumique du radon, en becquerels par mètre cube
I
4 Organisation des phases de mesure
La détermination de l’activité volumique du radon dans l’atmosphère d’un bâtiment s’appuie sur un
mode opératoire méthodique comprenant différentes phases de mesure:
— la mise en évidence de la présence de radon dans un bâtiment doit être réalisée au moyen d'un
dépistage conformément aux exigences fixées à l’Article 5. Cette phase vise à obtenir des résultats
de mesure pour évaluer l'activité volumique moyenne annuelle du radon, et qui sont comparés à la
valeur d'intérêt;
— si le dépistage fait apparaître une activité volumique du radon plus faible que l'une ou plusieurs valeurs
d'intérêt, la pérennité de la situation du bâtiment vis-à-vis du radon est contrôlée conformément aux
exigences fixées à l’Article 9. Si des modifications remettant en cause cette pérennité sont effectuées
dans ce bâtiment, un nouveau dépistage doit être mis en œuvre conformément aux exigences fixées
à l’Article 5;
— si le dépistage fait apparaître une activité volumique du radon supérieure à une ou plusieurs valeurs
d'intérêt, des opérations d’investigation destinées à identifier les causes d’un tel niveau de radon
sont réalisées (diagnostic technique du bâtiment, etc.). En fonction du type de bâtiment rencontré
et notamment, pour des bâtiments de grande surface au sol avec des soubassements complexes, des
investigations complémentaires peuvent être menées afin d’aider à identifier les sources du radon
(sol, matériaux de construction, eau) ainsi que ses voies d’entrées et de transfert dans le bâtiment.
Ces investigations complémentaires doivent être réalisées conformément aux exigences fixées à
l’Article 6;
— si des techniques de remédiation (actions simples comme la mise en route de la ventilation ou
effectuer des travaux de construction) sont mises en œuvre, la vérification immédiate de leur
efficacité peut être réalisée à court terme en effectuant des mesurages du radon non représentatifs
de la valeur moyenne annuelle (voir Article 7). L'efficacité puis la pérennité de ces actions de
remédiation doivent être contrôlées conformément aux exigences fixées aux Articles 8 et 9.
NOTE Un exemple d’organisation des différentes phases est donné à l’Annexe B.
4 © ISO 2019 – Tous droits réservés

---------------------- Page: 10 ----------------------
ISO 11665-8:2019(F)

5 Dépistage
5.1 Objectif
L’objectif du dépistage est de déterminer si un bâtiment ou une partie d’un bâtiment présente une
valeur d’activité volumique moyenne annuelle du radon supérieure à une ou plusieurs valeurs d’intérêt.
5.2 Méthodologie suivie lors du dépistage
Le dépistage doit être réalisé en suivant la chronologie décrite ci-après:
— choix des dispositifs de mesure;
— implantation des points de mesure dans le bâtiment;
— pose et dépose des dispositifs de mesure;
— traitement des dispositifs de mesure;
— analyse des données des résultats de mesure obtenus pour chaque zone homogène;
— rédaction du rapport de dépistage.
5.3 Choix des dispositifs de mesure
La méthode de mesure utilisée pour estimer l’activité volumique moyenne annuelle doit être la méthode
de mesure intégrée sur le long-terme conforme à l’ISO 11665-4.
Plusieurs types de dispositifs de mesure, répondant aux exigences de l’ISO 11665-4, peuvent être utilisés
dans le cadre du dépistage. Toutefois, afin de faciliter l’analyse des données ainsi que l’interprétation
des résultats de mesure, le même type de dispositif doit être utilisé par bâtiment.
Dans le cas d’une atmosphère spécifique où le facteur d’équilibre présente une forte variabilité
(atmosphère empoussiérée, à fort taux d’humidité, très ventilée, etc.), un dispositif de mesure passif dit
«en configuration fermée» doit être utilisé.
5.4 Implantation des points de mesure
5.4.1 Généralités
L’implantation des dispositifs de mesure suit un protocole en trois phases qui détermine:
— les zones homogènes du bâtiment étudié;
— le nombre de dispositifs nécessaires par zone homogène afin de réaliser des mesurages représentatifs;
— les lieux d’implantation des dispositifs de mesure dans les zones homogènes.
5.4.2 Détermination et sélection des zones homogènes
Les zones homogènes sont déterminées en partant du niveau le plus bas afin de progressivement
sélectionner une surface totale de zone homogène occupée au moins égale à la surface au sol du bâtiment.
Cette approche vise à sélectionner les zones homogènes qui présentent les activités volumiques de
radon les plus élevées.
© ISO 2019 – Tous droits réservés 5

---------------------- Page: 11 ----------------------
ISO 11665-8:2019(F)

Cette approche se découpe en deux phases:
— la détermination des zones homogènes est basée sur:
— les principaux critères suivants:
— même type d’interface sol-bâtiment;
— mêmes conditions de ventilation (pas de système de ventilation, ventilation naturelle,
ventilation mécanique, etc.);
— même niveau de température;
— les critères supplémentaires suivants lorsque l’eau peut être une source potentielle de radon:
— même mode d’alimentation en eau (direct, indirect, continu, recyclé);
— même type d’utilisation de l’eau (lavage, douche, soins thérapeutiques);
— la sélectio
...

Questions, Comments and Discussion