Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of radon and its short-lived decay products and associated measurement methods

This document outlines guidance for measuring radon-222 activity concentration and the potential alpha energy concentration of its short-lived decay products in the air. The measurement methods fall into three categories: a) spot measurement methods; b) continuous measurement methods; c) integrated measurement methods. This document provides several methods commonly used for measuring radon-222 and its short-lived decay products in air. This document also provides guidance on the determination of the inherent uncertainty linked to the measurement methods described in its different parts.

Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 1: Origine du radon et de ses descendants à vie courte, et méthodes de mesure associées

Le présent document présente les recommandations pour le mesurage de l'activité volumique du radon 222 et de l'énergie alpha potentielle volumique de ses descendants à vie courte dans l'air. Les méthodes de mesure se divisent en trois catégories: a) méthodes de mesure ponctuelle; b) méthodes de mesure en continu; c) méthodes de mesure intégrée. Le présent document fournit plusieurs méthodes couramment utilisées pour le mesurage du radon 222 et de ses descendants à vie courte dans l'air. Le présent document fournit également des recommandations relatives à la détermination de l'incertitude relative aux méthodes de mesure décrites dans ses diverses parties.

General Information

Status
Published
Publication Date
17-Sep-2019
Current Stage
9020 - International Standard under periodical review
Start Date
15-Jul-2024
Completion Date
15-Jul-2024
Ref Project

Relations

Buy Standard

Standard
ISO 11665-1:2019 - Measurement of radioactivity in the environment -- Air: radon-222
English language
33 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ISO 11665-1:2019 - Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of radon and its short-lived decay products and associated measurement methods Released:9/18/2019
English language
33 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11665-1:2019 - Mesurage de la radioactivité dans l'environnement -- Air: radon 222
French language
33 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ISO 11665-1:2019 - Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of radon and its short-lived decay products and associated measurement methods Released:9/18/2019
French language
33 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 11665-1
Second edition
2019-09
Measurement of radioactivity in the
environment — Air: radon-222 —
Part 1:
Origins of radon and its short-lived
decay products and associated
measurement methods
Mesurage de la radioactivité dans l'environnement — Air: radon 222 —
Partie 1: Origine du radon et de ses descendants à vie courte, et
méthodes de mesure associées
Reference number
©
ISO 2019
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 8
4 Principle .10
5 Equipment .10
6 Sampling .10
6.1 General .10
6.2 Sampling objective .11
6.3 Sampling characteristics . .11
6.4 Sampling conditions .11
6.4.1 Installation of sampling device .11
6.4.2 Sampling duration .12
6.4.3 Volume of air sampled . . .13
7 Detection .13
7.1 Silver-activated zinc sulphide ZnS(Ag) scintillation .13
7.2 Gamma-ray spectrometry.13
7.3 Liquid scintillation .13
7.4 Air ionization .14
7.5 Semi-conductor (alpha detection) .14
7.6 Solid-state nuclear track detectors (SSNTD) .14
7.7 Discharge of polarised surface inside an ionization chamber .14
8 Measurement .14
8.1 Methods .14
8.2 Influence quantities .15
8.3 Calibration .16
8.4 Quality control .16
9 Expression of results .16
10 Test report .16
Annex A (informative) Radon and its decay products — General information .18
Annex B (informative) Example of results of spot, integrated and continuous
measurements of radon-222 activity concentration .28
Annex C (informative) Example of a test report .30
Bibliography .31
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/iso/foreword .html.
This document was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies,
and radiological protection, Subcommittee SC 2, Radiological protection.
This second edition cancels and replaces the first edition (ISO 11665-1:2012), of which it constitutes a
minor revision. The changes compared to the previous edition are as follows:
— update of the Introduction;
— in A.2.4, details added for change in radon activities concentration in time and space in buildings;
— update of the Bibliography.
A list of all the parts in the ISO 11665 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2019 – All rights reserved

Introduction
Radon isotopes 222, 219 and 220 are radioactive gases produced by the disintegration of radium
isotopes 226, 223 and 224, which are decay products of uranium-238, uranium-235 and thorium-232
respectively, and are all found in the earth's crust (see Annex A for further information). Solid elements,
[1]
also radioactive, followed by stable lead are produced by radon disintegration .
When disintegrating, radon emits alpha particles and generates solid decay products, which are also
radioactive (polonium, bismuth, lead, etc.). The potential effects on human health of radon lie in its solid
decay products rather than the gas itself. Whether or not they are attached to atmospheric aerosols,
radon decay products can be inhaled and deposited in the bronchopulmonary tree to varying depths
[2][3][4][5]
according to their size .
[6]
Radon is today considered to be the main source of human exposure to natural radiation. UNSCEAR
suggests that, at the worldwide level, radon accounts for around 52 % of global average exposure to
natural radiation. The radiological impact of isotope 222 (48 %) is far more significant than isotope
220 (4 %), while isotope 219 is considered negligible (see Annex A). For this reason, references to radon
in this document refer only to radon-222.
Radon activity concentration can vary from one to more orders of magnitude over time and space.
Exposure to radon and its decay products varies tremendously from one area to another, as it depends
on the amount of radon emitted by the soil and building materials, weather conditions, and on the
degree of containment in the areas where individuals are exposed.
As radon tends to concentrate in enclosed spaces like houses, the main part of the population exposure
is due to indoor radon. Soil gas is recognized as the most important source of residential radon through
infiltration pathways. Other sources are described in other parts of ISO 11665 and ISO 13164 series for
[59]
water .
Radon enters into buildings via diffusion mechanism caused by the all-time existing difference between
radon activity concentrations in the underlying soil and inside the building, and via convection
mechanism inconstantly generated by a difference in pressure between the air in the building and the
air contained in the underlying soil. Indoor radon activity concentration depends on radon activity
concentration in the underlying soil, the building structure, the equipment (chimney, ventilation
systems, among others), the environmental parameters of the building (temperature, pressure, etc.)
and the occupants’ lifestyle.
-3
To limit the risk to individuals, a national reference level of 100 Bq·m is recommended by the World
[5] -3
Health Organization . Wherever this is not possible, this reference level should not exceed 300 Bq·m .
This recommendation was endorsed by the European Community Member States that shall establish
national reference levels for indoor radon activity concentrations. The reference levels for the annual
-3[5]
average activity concentration in air shall not be higher than 300 Bq·m .
To reduce the risk to the overall population, building codes should be implemented that require radon
prevention measures in buildings under construction and radon mitigating measures in existing
buildings. Radon measurements are needed because building codes alone cannot guarantee that radon
concentrations are below the reference level.
ISO 11665 consists of several parts (see Figure 1) dealing with:
— measurement met
...


Deleted: ©
Deleted: –All rights reserved
ISO TC 85/SC 2
Formatted: Font: 12 pt, Bold
Formatted: Font: 12 pt, Bold
Date : 2019-09
Style Definition: Heading 1:
Indent: Left: 0 pt, First line: 0 pt,
Tab stops: Not at 21.6 pt
Style Definition: Heading 2: Font:
ISO TC 85/SC 2
Bold, Tab stops: Not at 18 pt
Style Definition: Heading 3: Font:
Secretariat: AFNOR
Bold
Style Definition: Heading 4: Font:
Measurement of radioactivity in the environment — Air: Radon 222 — Part 1:
Bold
Origins of radon and its short-lived decay products and associated measurement
Style Definition: Heading 5: Font:
methods Bold
Style Definition: Heading 6: Font:
Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 1 : Origine Bold
du radon et de ses descendants à vie courte et méthodes de mesure associées Style Definition: ANNEX
Style Definition: Code: Tab stops:
16.15 pt, Left + 32.6 pt, Left +
48.75 pt, Left + 65.2 pt, Left +
81.35 pt, Left + 97.8 pt, Left +
113.95 pt, Left + 130.4 pt, Left +
146.55 pt, Left + 162.75 pt, Left
Style Definition: RefNorm
Style Definition: List Continue 5:
Font: Indent: Hanging: 20.15 pt,
Don't add space between
paragraphs of the same style
Style Definition: Body Text_Center
Style Definition: Dimension_100
Style Definition: Figure subtitle
Style Definition: Figure Graphic
Style Definition
... [6]
Style Definition: List Continue 1
Style Definition
... [5]
Style Definition
... [4]
Style Definition
... [3]
Style Definition: Note indent 2
Style Definition
... [2]
Style Definition
... [1]
Formatted
... [7]
Formatted: English (U.S.)
Formatted
... [8]
Deleted: xx
Formatted: English (U.S.)
Formatted
... [9]
Deleted: /FDIS
Formatted
... [10]
Formatted: English (U.S.)
Formatted
... [11]
Formatted: Font: Not Bold
Deleted: /FDIS
© ISO 2019, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or
utilized otherwise in any form or by any means, electronic or mechanical, including photocopying,
or posting on the internet or an intranet, without prior written permission. Permission can be
requested from either ISO at the address below or ISO’s member body in the country of the
requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH‐1214 Vernier, Geneva, Switzerland
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
copyright@iso.org
www.iso.org
Deleted: www.iso.org¶
ii © ISO 2019 – All rights reserved

Deleted: /FDIS
Contents
Foreword . 4
Introduction. 5
1  Scope . 1
2  Normative references . 1
3  Terms, definitions and symbols . 1
4  Principle . 9
5  Equipment . 10
6  Sampling . 10
7  Detection . 12
8  Measurement . 14
9  Expression of results . 16
10  Test report . 16
Annex A (informative) Radon and its decay products — General information . 18
A.1  Radon isotopes . 18
A.2  Changes in radon activity concentration . 19
A.2.1  In the soil . 19
A.2.2  At the soil-atmosphere interface . 20
atmosphere . 20
A.2.3  In the
A.2.4  In buildings . 21
A.3  Short-lived radon-222 decay products . 25
Annex B (informative) Example of results of spot, integrated and continuous
measurements of radon-222 activity concentration . 28
Annex C (informative) Example of a test report . 30
Bibliography . 31

© ISO 2019 – All rights reserved iii

Deleted: /FDIS
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national
standards bodies (ISO member bodies). The work of preparing International Standards is normally
carried out through ISO technical committees. Each member body interested in a subject for which a
technical committee has been established has the right to be represented on that committee.
International organizations, governmental and non‐governmental, in liaison with ISO, also take part in
the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all
matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Deleted: www.iso.org/directives
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents). Deleted: www.iso.org/patents
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www.iso.org/iso/foreword.html. Deleted: www.iso.org/iso/forewor
d.html
This document was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies,
and radiological protection, Subcommittee SC 2, Radiological protection.
This second edition cancels and replaces the first edition (ISO 11665‐1:2012), of which it constitutes a
minor revision. The changes compared to the previous edition are as follows:
— update of the Introduction; Formatted: List Continue 1
— in A.2.4, details added for change in radon activities concentration in time and space in buildings;
— update of the Bibliography.
A list of all the parts in the ISO 11665 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html. Deleted: www.iso.org/members.ht
ml
iv © ISO 2019 – All rights reserved

Deleted: /FDIS
Introduction
Radon isotopes 222, 219 and 220 are radioactive gases produced by the disintegration of radium
isotopes 226, 223 and 224, which are decay products of uranium‐238, uranium‐235 and thorium‐232
respectively, and are all found in the earth's crust (see Annex A for further information). Solid elements,
[1]
also radioactive, followed by stable lead are produced by radon disintegration .
When disintegrating, radon emits alpha particles and generates solid decay products, which are also
radioactive (polonium, bismuth, lead, etc.). The potential effects on human health of radon lie in its solid
decay products rather than the gas itself. Whether or not they are attached to atmospheric aerosols,
radon decay products can be inhaled and deposited in the bronchopulmonary tree to varying depths
[2][3][4][5]
according to their size .
[6]
Radon is today considered to be the main source of human exposure to natural radiation. UNSCEAR
suggests that, at the worldwide level, radon accounts for around 52 % of global average exposure to
natural radiation. The radiological impact of isotope 222 (48 %) is far more significant than isotope
220 (4 %), while isotope 219 is considered negligible (see Annex A). For this reason, references to
radon in this document refer only to radon‐222.
Radon activity concentration can vary from one to more orders of magnitude over time and space.
Exposure to radon and its decay products varies tremendously from one area to another, as it depends
on the amount of radon emitted by the soil and building materials, weather conditions, and on the
degree of containment in the areas where individuals are exposed.
As radon tends to concentrate in enclosed spaces like houses, the main part of the population exposure
is due to indoor radon. Soil gas is recognized as the most important source of residential radon through
infiltration pathways. Other sources are described in other parts of ISO 11665 and ISO 13164 series for
[58]
water .
Radon enters into buildings via diffusion mechanism caused by the all‐time existing difference between
radon activity concentrations in the underlying soil and inside the building, and via convection
mechanism inconstantly generated by a difference in pressure between the air in the building and the
air contained in the underlying soil. Indoor radon activity concentration depends on radon activity
concentration in the underlying soil, the building structure, the equipment (chimney, ventilation
systems, among others), the environmental parameters of the building (temperature, pressure, etc.) and
the occupants’ lifestyle.
‐3
To limit the risk to individuals, a national reference level of 100 Bq·m is recommended by the World
[5] ‐3
Health Organization . Wherever this is not possible, this reference level should not exceed 300 Bq·m .
This recommendation was endorsed by the European Community Member States that shall establish
national reference levels for indoor radon activity concentrations. The reference levels for the annual
‐3[5]
average activity concentration in air shall not be higher than 300 Bq·m .
To reduce the risk to the overall population, building codes should be implemented that require radon
prevention measures in buildings under construction and radon mitigating measures in existing
buildings. Radon measurements are needed because building codes alone cannot guarantee that radon
concentrations are below the reference level.
ISO 11665 consists of several parts (see Figure 1) dealing with:
— measurement methods for radon‐222 and its short‐lived decay products (see ISO 11665‐2,
ISO 11665‐3, ISO 11665‐4, ISO 11665‐5 and ISO 11665‐6);
NOTE 1 There are many methods for measuring the radon‐222 activity concentration and the potential
alpha energy concentration of its short‐lived decay products. The choice of measurement method depends on
the expected level of concentration and on the intended use of the data, such as scientific research and health‐
[8][9]
.
related assessments
— measurement methods for the radon‐222 exhalation rate (see ISO 11665‐7 and ISO 11665‐9);
© ISO 2019 – All rights reserved v

Deleted: /FDIS
NOTE 2 ISO 11665‐7 refers back to ISO 11665‐5 and ISO 11665‐6.
— measurement methods for the radon‐222 in the soil (see ISO 11665‐11);
— methodologies for radon‐222 measurements in buildings (see ISO 11665‐8);
— measurement methods for the radon‐222 diffusion coefficient (see ISO/TS 11665‐12 and
ISO/TS 11665‐13)
NOTE 3 ISO 11665‐8 refers back to ISO 11665‐4 for radon measurements for initial investigation purposes
in a building and to ISO 11665‐5, ISO 11665‐6 and ISO 11665‐7 for measurements for any additional
investigation.
vi © ISO 2019 – All rights reserved

Deleted: /FDIS
Deleted:
Figure 1 — Structure of the ISO 11665 series
© ISO 2019 – All rights reserved vii

Deleted: /FDIS
Measurement of radioactivity in the environment —
Air: Radon 222 — Part 1: Origins of radon and its short-lived
decay products and associated measurement methods
1 Scope
This document outlines guidance for measuring radon‐222 activity concentration and the potential
alpha en
...


NORME ISO
INTERNATIONALE 11665-1
Deuxième édition
2019-09
Mesurage de la radioactivité dans
l'environnement — Air: radon 222 —
Partie 1:
Origine du radon et de ses
descendants à vie courte, et méthodes
de mesure associées
Measurement of radioactivity in the environment — Air:
radon-222 —
Part 1: Origins of radon and its short-lived decay products and
associated measurement methods
Numéro de référence
©
ISO 2019
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.2 Symboles . 9
4 Principe .10
5 Équipement .10
6 Prélèvement .10
6.1 Généralités .10
6.2 Objectif du prélèvement .11
6.3 Caractéristiques du prélèvement .11
6.4 Conditions de prélèvement .11
6.4.1 Installation du dispositif de prélèvement .11
6.4.2 Durée de prélèvement .12
6.4.3 Volume d’air prélevé .13
7 Détection .13
7.1 Scintillation du sulfure de zinc activé à l’argent ZnS(Ag) .13
7.2 Spectrométrie gamma .13
7.3 Scintillation liquide .13
7.4 Ionisation de l’air .14
7.5 Semi-conducteur (détection alpha) .14
7.6 Détecteurs solides de traces nucléaires (DSTN) .14
7.7 Décharge d’une surface polarisée à l’intérieur d’une chambre d’ionisation .14
8 Mesurage.14
8.1 Méthodes .14
8.2 Grandeurs d’influence.15
8.3 Étalonnage .16
8.4 Contrôle qualité .16
9 Expression des résultats.16
10 Rapport d’essai .16
Annexe A (informative) Radon et ses descendants — Informations générales .18
Annexe B (informative) Exemple de résultats de mesure ponctuelle, intégrée et en continu
de l’activité volumique du radon 222 .28
Annexe C (informative) Exemple de rapport d’essai .30
Bibliographie .31
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC 85, Énergie nucléaire, technologies
nucléaires, et radioprotection, sous-comité SC 2, Radioprotection.
Cette deuxième édition annule et remplace la première édition (ISO 11665-1:2012), dont elle constitue
une révision mineure. Les modifications par rapport à l’édition précédente sont les suivantes:
— l’Introduction a été mise à jour;
— en A.2.4, des détails ont été ajoutés pour tenir compte de la variation des activités volumiques du
radon ans le temps et dans l’espace dans les bâtiments;
— la Bibliographie a été mise à jour.
Une liste de toutes les parties de la série ISO 11665 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
iv © ISO 2019 – Tous droits réservés

Introduction
Les isotopes 222, 219 et 220 du radon sont des gaz radioactifs produits par la désintégration des
isotopes 226, 223 et 224 du radium, lesquels sont respectivement des descendants de l’uranium 238, de
l’uranium 235 et du thorium 232, et sont tous présents dans l’écorce terrestre (voir Annexe A pour plus
d’informations). Des éléments solides, eux aussi radioactifs, suivis par du plomb stable, sont produits
[1]
par la désintégration du radon .
Lorsqu’il se désintègre, le radon émet des particules alpha et génère des descendants solides qui sont
eux aussi radioactifs (par exemple polonium, bismuth, plomb, etc.). Les effets potentiels du radon sur
la santé humaine sont liés aux descendants plutôt qu’au gaz lui-même. Qu’ils soient ou non attachés à
des aérosols atmosphériques, les descendants du radon peuvent être inhalés et déposés dans l’arbre
[2][3][4][5]
broncho-pulmonaire à différentes profondeurs, suivant leur taille .
Le radon est aujourd’hui considéré comme la principale source d’exposition de l’homme au rayonnement
[6]
naturel. L’UNSCEAR suggère qu’au niveau mondial, le radon intervient pour environ 52 % de
l’exposition moyenne globale au rayonnement naturel. L’impact radiologique de l’isotope 222 (48 %)
est nettement plus important que celui de l’isotope 220 (4 %), l’isotope 219 est quant à lui considéré
comme négligeable (voir Annexe A). Pour cette raison, les références au radon dans le présent document
désignent exclusivement le radon 222.
L’activité volumique du radon peut varier d’un à plusieurs ordres de grandeur dans le temps et l’espace.
L’exposition au radon et à ses descendants varie considérablement d’un lieu à l’autre. Elle dépend de
la quantité de radon émise par le sol et des matériaux de construction en ces lieux, des conditions
météorologiques et du degré de confinement dans les lieux où sont exposées les personnes.
Comme le radon a tendance à se concentrer dans les espaces clos tels que les maisons, la majeure partie
de l’exposition de la population provient du radon présent dans l’atmosphère intérieure des bâtiments.
Le gaz issu du sol est considéré comme la source la plus importante de radon résidentiel via des voies
d’infiltration. D’autres sources sont décrites dans d’autres parties de l’ISO 11665 et dans la série
[59]
ISO 13164 pour l’eau .
Le radon pénètre dans les bâtiments par un mécanisme de diffusion dû à la différence permanente
entre l’activité volumique du radon dans le sol sous-jacent et celle existant à l’intérieur du bâtiment,
et par un mécanisme de convection généré par intermittence par une différence de pression entre l’air
dans le bâtiment et celui contenu dans le sol sous-jacent. L’activité volumique du radon à l’intérieur des
bâtiments dépend de l’activité volumique du radon dans le sol sous-jacent, de la structure du bâtiment,
des équipements (cheminée, systèmes de ventilation mécanique, entre autres), des paramètres
environnementaux du bâtiment (température, pression, etc.), mais également du mode de vie de ses
occupants.
–3
Pour limiter le r
...


Style Definition: Heading 1:
ISO/TC 85/SC 2
Indent: Left: 0 pt, First line: 0 pt
Style Definition: Heading 2: Font:
Date : 2019‐09
Bold, Tab stops: Not at 18 pt
Bold
ISO/TC 85/SC 2 Style Definition: Heading 4: Font:
Bold
Secrétariat: AFNOR Style Definition: Heading 5: Font:
Bold
Style Definition: Heading 6: Font:
Bold
Style Definition: ANNEX
Style Definition: RefNorm
Style Definition: List Number 1
Style Definition: Dimension_100
Mesurage de la radioactivité dans l’environnement — Air: radon 222 — Partie 1:
Style Definition: Body Text_Center
Origine du radon et de ses descendants à vie courte, et méthodes de mesure
Style Definition: Figure subtitle
associées
Style Definition: Figure Graphic
Style Definition: List Continue 1
Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of
Style Definition: AMEND Terms
radon and its short-lived decay products and associated measurement methods
Heading: Font: Bold
Style Definition: AMEND Heading
1 Unnumbered: Font: Bold
Deleted: 05‐13
Deleted: /FDIS
Type du document : Norme internationale
Sous‐type du document :
Stade du document : (50) Approbation
Langue du document : F
Deleted: /FDIS
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne
peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique
ou mécanique, y compris la photocopie, l’affichage sur l’internet ou sur un Intranet, sans
autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci‐après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH‐1214 Vernier, Geneva, Switzerland
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
copyright@iso.org
www.iso.org Deleted: www.iso.org

Publié en Suisse
© ISO 2019 – Tous droits réservés
ii
Deleted: /FDIS
Sommaire Page
Avant-propos . 4
Introduction . 5
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.2 Symboles . 9
4 Principe . 11
5 Équipement . 11
6 Prélèvement . 11
6.1 Généralités . 11
6.2 Objectif du prélèvement . 12
6.3 Caractéristiques du prélèvement . 12
6.4 Conditions de prélèvement . 12
6.4.1 Installation du dispositif de prélèvement . 12
6.4.2 Durée de prélèvement . 13
6.4.3 Volume d’air prélevé . 14
7 Détection . 14
7.1 Scintillation du sulfure de zinc activé à l’argent ZnS(Ag) . 14
7.2 Spectrométrie gamma . 14
7.3 Scintillation liquide . 14
7.4 Ionisation de l’air . 15
7.5 Semi-conducteur (détection alpha) . 15
7.6 Détecteurs solides de traces nucléaires (DSTN) . 15
7.7 Décharge d’une surface polarisée à l’intérieur d’une chambre d’ionisation . 15
8 Mesurage . 15
8.1 Méthodes . 15
8.2 Grandeurs d’influence . 16
8.3 Étalonnage . 17
8.4 Contrôle qualité . 17
9 Expression des résultats . 17
10 Rapport d’essai . 17
Annexe A (informative) Radon et ses descendants — Informations générales . 19
Annexe B (informative) Exemple de résultats de mesure ponctuelle, intégrée et en continu
de l’activité volumique du radon 222. 29
Annexe C (informative) Exemple de rapport d’essai . 31
Bibliographie . 32

© ISO 2019 – Tous droits réservés
iii
Deleted: /FDIS
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le
droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2
(voir www.iso.org/directives). Deleted: www.iso.org/directives
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant les
références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Deleted: www.iso.org/brevets
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www.iso.org/iso/fr/avant‐propos. Deleted: www.iso.org/iso/fr/avant‐propos
Le présent document a été élaboré par le comité technique ISO/TC 85, Énergie nucléaire, technologies
nucléaires, et radioprotection, sous‐comité SC 2, Radioprotection.
Cette deuxième édition annule et remplace la première édition (ISO 11665‐1:2012), dont elle constitue
une révision mineure. Les modifications par rapport à l’édition précédente sont les suivantes:
— l’Introduction a été mise à jour;
— en A.2.4, des détails ont été ajoutés pour tenir compte de la variation des activités volumiques du
radon ans le temps et dans l’espace dans les bâtiments;
— la Bibliographie a été mise à jour.
Une liste de toutes les parties de la série ISO 11665 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html. Deleted: www.iso.org/fr/members.html
© ISO 2019 – Tous droits réservés
iv
Deleted: /FDIS
Introduction
Les isotopes 222, 219 et 220 du radon sont des gaz radioactifs produits par la désintégration des
isotopes 226, 223 et 224 du radium, lesquels sont respectivement des descendants de l’uranium 238, de
l’uranium 235 et du thorium 232, et sont tous présents dans l’écorce terrestre (voir Annexe A pour plus
d’informations). Des éléments solides, eux aussi radioactifs, suivis par du plomb stable, sont produits
[1]
par la désintégration du radon .
Lorsqu’il se désintègre, le radon émet des particules alpha et génère des descendants solides qui sont
eux aussi radioactifs (par exemple polonium, bismuth, plomb, etc.). Les effets potentiels du radon sur la
santé humaine sont liés aux descendants plutôt qu’au gaz lui‐même. Qu’ils soient ou non attachés à des
aérosols atmosphériques, les descendants du radon peuvent être inhalés et déposés dans l’arbre
[2][3][4][5]
broncho‐pulmonaire à différentes profondeurs, suivant leur taille .
Le radon est aujourd’hui considéré comme la principale source d’exposition de l’homme au
[6]
rayonnement naturel. L’UNSCEAR suggère qu’au niveau mondial, le radon intervient pour environ
52 % de l’exposition moyenne globale au rayonnement naturel. L’impact radiologique de l’isotope 222
(48 %) est nettement plus important que celui de l’isotope 220 (4 %), l’isotope 219 est quant à lui
considéré comme négligeable (voir Annexe A). Pour cette raison, les références au radon dans le
présent document désignent exclusivement le radon 222.
L’activité volumique du radon peut varier d’un à plusieurs ordres de grandeur dans le temps et l’espace.
L’exposition au radon et à ses descendants varie considérablement d’un lieu à l’autre. Elle dépend de la
quantité de radon émise par le sol et des matériaux de construction en ces lieux, des conditions
météorologiques et du degré de confinement dans les lieux où sont exposées les personnes.
Comme le radon a tendance à se concentrer dans les espaces clos tels que les maisons, la majeure partie
de l’exposition de la population provient du radon présent dans l’atmosphère intérieure des bâtiments.
Le gaz issu du sol est considéré comme la source la plus importante de radon résidentiel via des voies
d’infiltration. D’autres sources sont décrites dans d’autres parties de l’ISO 11665 et dans la série
[58]
ISO 13164 pour l’eau .
Le radon pénètre dans les bâtiments par un mécanisme de diffusion dû à la différence permanente
entre l’activité volumique du radon dans le sol sous‐jacent et celle existant à l’intérieur du bâtiment, et
par un mécanisme de convection généré par intermittence par une différence de pression entre l’air
dans le bâtiment et celui contenu dans le sol sous‐jacent. L’activité volumique du radon à l’intérieur des
bâtiments dépend de l’activité volumique du radon dans le sol sous‐jacent, de la structure du bâtiment,
des équipements (cheminée, systèmes de ventilation mécanique, entre autres), des paramètres
environnementaux du bâtiment (température, pression, etc.), mais également du mode de vie de ses
occupants.
–3
Pour limiter le risque pour les individus, un niveau de référence national de 100 Bq·m est
[5]
recommandé par l’Organisation mondiale de la santé . Lorsque cela n’est pas possible, il convient que
−3
ce niveau de référence ne dépasse pas 300 Bq·m . Cette recommandation a été entérinée par les États
membres de la Communa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.