ISO/DIS 13174
(Main)Cathodic protection for harbour installations
Cathodic protection for harbour installations
Protection cathodique des installations portuaires
General Information
RELATIONS
Standards Content (sample)
DRAFT INTERNATIONAL STANDARD ISO/DIS 13174
Attributed to ISO/TC 156 by the Central Secretariat (see page iii)
Voting begins on Voting terminates on
2005-04-05 2005-09-05
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
FAST-TRACK PROCEDURECathodic protection for harbour installations
Protection cathodique des installations portuaires
ICS 47.020.99; 77.060
THIS DOCUMENT IS A DRAFT CIRCULATED FOR COMMENT AND APPROVAL. IT IS THEREFORE SUBJECT TO CHANGE AND MAY NOT BE
REFERRED TO AS AN INTERNATIONAL STANDARD UNTIL PUBLISHED AS SUCH.IN ADDITION TO THEIR EVALUATION AS BEING ACCEPTABLE FOR INDUSTRIAL, TECHNOLOGICAL, COMMERCIAL AND USER PURPOSES,
DRAFT INTERNATIONAL STANDARDS MAY ON OCCASION HAVE TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL TO BECOME
STANDARDS TO WHICH REFERENCE MAY BE MADE IN NATIONAL REGULATIONS.International Organization for Standardization, 2005
---------------------- Page: 1 ----------------------
ISO/DIS 13174
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
Copyright noticeThis ISO document is a Draft International Standard and is copyright-protected by ISO. Except as permitted
under the applicable laws of the user's country, neither this ISO draft nor any extract from it may be
reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic,
photocopying, recording or otherwise, without prior written permission being secured.
Requests for permission to reproduce should be addressed to either ISO at the address below or ISO's
member body in the country of the requester.ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Reproduction may be subject to royalty payments or a licensing agreement.
Violators may be prosecuted.
ii © ISO 2005 — All rights reserved
---------------------- Page: 2 ----------------------
ISO/DIS 13174
NOTE FROM THE ISO CENTRAL SECRETARIAT
This draft International Standard is submitted for voting to ISO member bodies under the fast-track procedure.
Technical Committee ISO/TC 156, Corrosion of metals and alloys, at its meeting held in May 2004, decided to
approve the submission of the standard EN 13174:2001, Cathodic protection for harbour installations, for
processing under the “Fast-track procedure”, in accordance with the provisions of Clause F.2, Annex F, of the
ISO/IEC Directives, Part 1 (fourth edition, 2001).F.2 “Fast-track procedure”
F.2.1 Proposals to apply the fast-track procedure may be made as follows.
F.2.1.1 Any P-member or category A liaison organization of a concerned technical committee may propose that
an existing standard from any source be submitted for vote as an enquiry draft. The proposer shall obtain the
agreement of the originating organization before making a proposal. The criteria for proposing an existing
standard for the fast-track procedure are a matter for each proposer to decide.F.2.1.2 An international standardizing body recognized by the ISO or IEC council board may propose that a
standard developed by that body be submitted for vote as a final draft International Standard.
F.2.1.3 An organization having entered into a formal technical agreement with ISO or IEC may propose, in
agreement with the appropriate technical committee or subcommittee, that a draft standard developed by that
organization be submitted for vote as an enquiry draft within that technical committee or subcommittee.
F.2.2 The proposal shall be received by the Chief Executive Officer, who shall take the following actions:
a) settle the copyright and/or trademark situation with the organization having originated the proposed
document, so that it can be freely copied and distributed to national bodies without restriction;
b) for cases F.2.1.1 and F.2.1.3, assess in consultation with the relevant secretariats which technical
committee/subcommittee is competent for the subject covered by the proposed document; where no
technical committee exists competent to deal with the subject of the document in question, the Chief
Executive Officer shall refer the proposal to the technical management board, which may request the Chief
Executive Officer to submit the document to the enquiry stage and to establish an ad hoc group to deal with
matters subsequently arising;c) ascertain that there is no evident contradiction with other International Standards;
d) distribute the proposed document as an enquiry draft (F.2.1.1 and F.2.1.3) in accordance with 2.6.1, or as a
final draft International Standard (case F.2.1.2) in accordance with 2.7.1, indicating (in cases F.2.1.1 and
F.2.1.3) the technical committee/subcommittee to the domain of which the proposed document belongs.
F.2.3 The period for voting and the conditions for approval shall be as specified in 2.6 for an enquiry draft and
2.7 for a final draft International Standard. In the case where no technical committee is involved, the condition for
approval of a final draft International Standard is that not more than one-quarter of the total number of votes cast
are negative.F.2.4 If, for an enquiry draft, the conditions of approval are met, the draft standard shall progress to the
approval stage (2.7). If not, the proposal has failed and any further action shall be decided upon by the technical
committee/subcommittee to which the document was attributed in accordance with F.2.2 b).
If, for a final draft International Standard, the conditions of approval are met, the document shall progress to the
publication stage (2.8). If not, the proposal has failed and any further action shall be decided upon by the
technical committee/subcommittee to which the FDIS was attributed in accordance with F.2.2 b), or by
discussion between the originating organization and the office of the CEO if no technical committee was
involved.If the standard is published, its maintenance shall be handled by the technical committee/subcommittee to which
the document was attributed in accordance with F.2.2 b), or, if no technical committee was involved, the
approval procedure set out above shall be repeated if the originating organization decides that changes to the
standard are required.© ISO 2005 — All rights reserved iii
---------------------- Page: 3 ----------------------
Page 2
EN 13174:2005
Contents
Foreword......................................................................................................................................................................4
Introduction .................................................................................................................................................................5
1 Scope ......................................................................................................................................................................5
1.1 Structures ............................................................................................................................................................5
1.2 Materials...............................................................................................................................................................5
1.3 Environment ........................................................................................................................................................5
1.4 Safety and environment protection...................................................................................................................5
2 Normative references ............................................................................................................................................6
3 Terms and definitions............................................................................................................................................6
4 Design basis ...........................................................................................................................................................9
4.1 Objectives............................................................................................................................................................9
4.2 Cathodic protection criteria ...............................................................................................................................9
4.3 Design parameters............................................................................................................................................10
4.4 Electrical current demand................................................................................................................................10
4.5 Cathodic protection systems...........................................................................................................................12
4.6 Electrical continuity..........................................................................................................................................13
........................................................................................................................................................13
4.7 Interactions......................................................................................................................14
5 Impressed current system design..........................................................................................................................................................14
5.1 Objectives......................................................................................................................................14
5.2 Design considerations...............................................................................................................................15
5.3 Equipment considerations...........................................................................................................................17
6 Galvanic anode system design..........................................................................................................................................................17
6.1 Objectives......................................................................................................................................17
6.2 Design considerations...............................................................18
6.3 Factors determining the anode current output and operating life
---------------------- Page: 4 ----------------------
Page 3
EN 13174:2005
6.4 Location of anodes ...........................................................................................................................................18
7 Cathodic protection system monitoring............................................................................................................19
7.1 Objectives..........................................................................................................................................................19
7.2 Potential measurements ..................................................................................................................................19
7.3 Measurement of impressed current anode electrical current output..........................................................19
7.4 Impressed current power source control.......................................................................................................20
8 Documentation.....................................................................................................................................................20
8.1 Objectives..........................................................................................................................................................20
8.2 Impressed current system ...............................................................................................................................20
8.3 Galvanic anodes system ..................................................................................................................................21
Annex A (informative) Guidance for current requirements for cathodic protection of harbour installations..22
A.1 Design current densities for the protection of bare steel in sea water.......................................................22
A.2 Design current densities for the protection of bare steel in saline mud ....................................................22
A.3 Values of coating breakdown factors of usual paint systems for the design of cathodic protection
systems......................................................................................................................................................................22
Annex B (informative) Anode resistance and life determination ..........................................................................23
B.1 Anodic resistance (R ) formulae .....................................................................................................................23
B.2 Anode life duration...........................................................................................................................................24
.........................25Annex C (informative) Typical electrochemical characteristics of impressed current anodes
---------------------- Page: 5 ----------------------Page 4
EN 13174:2005
Foreword
This European Standard has been prepared by Technical Committee CEN/TC 219 "Cathodic protection", the
secretariat of which is held by BSI.This European Standard shall be given the status of a national standard, either by publication of an identical text or by
endorsement, at the latest by July 2001, and conflicting national standards shall be withdrawn at the latest by July
2001.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries
are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France,
Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland
and the United Kingdom.---------------------- Page: 6 ----------------------
Page 5
EN 13174:2005
Introduction
Cathodic protection, is usually applied, together with protective coatings or paint to protect the external surfaces of
steel harbour installations and appurtenances from corrosion due to sea water or saline mud.
Cathodic protection works by supplying sufficient direct current to the immersed external surface of the structure in
order to change the steel to electrolyte potential to values where corrosion is insignificant.
The general principles of cathodic protection are detailed in EN 12473.1 Scope
This European Standard defines the means to be used to cathodically protect the immersed and buried metallic
external surfaces of steel harbour installations and appurtenances in sea water and saline mud.
1.1 StructuresThis European Standard covers the cathodic protection of fixed and floating structures. This essentially includes piers,
jetties, dolphins (mooring and berthing), sheet or tubular piling, pontoons, buoys, floating docks, lock and sluice gates.
It also covers the submerged areas of appurtenances, such as chains attached to the structure, when these are not
electrically isolated from the structure.It does not cover the cathodic protection of fixed or floating offshore structures, submarine pipelines or ships.
This European Standard does not include the internal protection of surfaces of any components such as ballast tanks
and internals of floating structures or the internals or back faces of sheet steel piling which is in contact with backfill.
1.2 MaterialsThis European Standard covers the cathodic protection of structures fabricated principally from bare or coated carbon
manganese steels.As some parts of the structure may be made of metallic materials other than carbon manganese steels, the cathodic
protection system should be designed to ensure that there is a complete control over any galvanic coupling and
minimise risks due to hydrogen embrittlement or hydrogen induced cracking (see EN 12473).
This European Standard does not cover concrete structures.1.3 Environment
This European Standard is applicable to the whole submerged zone in sea water, brackish waters and saline mud
which can normally be found in harbour installations wherever these structures are fixed or floating.
For surfaces which are alternately immersed and exposed to the atmosphere, the cathodic protection is only effective
when the immersion time is sufficiently long for the steel to become polarised.1.4 Safety and environment protection
This European Standard does not cover safety and environmental protection aspects associated with cathodic
protection. The relevant national or international regulations shall apply.---------------------- Page: 7 ----------------------
Page 6
EN 13174:2005
2 Normative references
This European Standard incorporates, by dated or undated references, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated
references, subsequent amendments to or revisions of any of these publications apply to this European Standard only
when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred
to applies (including amendments).General principles of cathodic protection in sea water
EN 12473, .
prEN 12496, Galvanic anodes for cathodic protection in sea water.
3 Terms and definitions
For the purposes of this European Standard the terms and definitions in EN 12473 and the following apply:
3.1atmospheric zone
zone located above the splash zone, ie. above the level reached by the normal swell, whether the structure is moving
or not3.2
buried zone
zone located under the mud line
3.3
Cathodic Protection zone
that part of the structure which can be considered independently with respect to cathodic protection design
3.4extended tidal zone
zone including the tidal zone, the splash zone and the transition zone
3.5
H.A.T.
level of highest astronomical tide
3.6
immersed zone
zone located above the mud line and below the extended tidal zone or the water line at a draught corresponding to
the normal working conditions3.7
L.A.T.
level of lowest astronomical tide
3.8
M.T.L.
mean tide level (also known as M.S.L. or M.W.L.)
3.9
R.O.V.
remotely operated vehicle
---------------------- Page: 8 ----------------------
Page 7
EN 13174:2005
3.10
piling
deep foundation tubular or sheet steel element forming part or whole harbour structure
3.11splash zone
the height of the structure which is intermittently wet and dry due to the wave action just above the H.A.T
3.12submerged zone
zone including the buried zone, the immersed zone and the transition zone
3.13
transition zone
zone located below L.A.T. and including the possible level inaccuracy of the structure installation which is affected by
a higher oxygen content due to normal swell or tidal movement---------------------- Page: 9 ----------------------
Page 8
EN 13174:2005
Figure 1 – Schematic representation of levels and zones in sea water environment
---------------------- Page: 10 ----------------------
Page 9
EN 13174:2005
4 Design basis
4.1 Objectives
The major objective of a cathodic protection system is to deliver sufficient current to each part of the structure and
appurtenances and distribute this current so that the potential of each part of the structure is within the limits given by
the protection criteria (see 4.2).Potentials should be as uniform as possible over the whole structure. This may be approached only by an adequate
distribution of the protective current over the structure during normal service conditions, however it may be difficult to
achieve in some areas such as chains, when a supplementary cathodic protection system should be considered.
The cathodic protection system for a fixed and floating structure is generally combined with a coating system, even
though some appurtenances such as chains, may not benefit from the use of coatings. Extensive coating damage
may also occur to buried areas of piling which is driven into position during installation.
Dielectric shields may be used in conjunction with anodes to minimise the risk of local over-protection.
The cathodic protection system should be designed either for the life time of the structure or for a period
corresponding to maintenance or dry-docking interval. Alternatively when it is not feasible to design the cathodic
protection system for the life of the structure or dry-docking is not possible, the system should be designed for easy
replacement, typically using divers or R.O.V.The above objectives should be achieved by the design of a cathodic protection system using impressed current or
galvanic anode systems or a combination of both.4.2 Cathodic protection criteria
The criteria for cathodic protection are detailed in EN 12473.
To achieve an adequate cathodic protection level, steel structures should have potentials as indicated hereafter.
The accepted criterion for protection of steel in aerated sea water is a polarised potential more negative than
-0,80 V measured with respect to silver/silver chloride/sea water reference electrode (Ag/AgCl/sea water reference
electrode).However, steel immersed in solutions which contain active sulphate reducing bacteria (anaerobic conditions),
because of the possibility of microbiologically induced corrosion, a potential more negative than -0,90 V (Ag/AgCl/sea
water reference electrode) is generally recommended.A negative limit of -1,10 V (Ag/AgCl/sea water reference electrode) is generally recommended for coated structures.
Where there is a possibility of corrosion fatigue, the negative limit should be more positive. This negative limit should
be documented.---------------------- Page: 11 ----------------------
Page 10
EN 13174:2005
4.3 Design parameters
The design of a cathodic protection system should be made in accordance with the following parameters: structure
subdivision, component description and service conditions.4.3.1 Structure subdivision
Harbour structures to be protected can be divided into different Cathodic Protection zones, (CP zones), which can be
considered independently with respect to cathodic protection design, although they may not necessarily be electrically
isolated.EXAMPLE 1 For a berthing dolphin, the area of piling can be divided into two main CP zones: the immersed or wetted CP zone
and the buried CP zone. This division is related to the high current demand of the immersed or wetted CP zone due to the
velocity of water movement, salinity, oxygen content and temperature. In the buried CP zone the current demand will be reduced
due to the environment. There may be some specific elements which would not be included in a CP zone and therefore
constitute a CP zone by themselves e.g. seawater intakes.EXAMPLE 2 For buoys, a single zone is generally considered, sufficient to cover the body of the buoy and the influenced part
of the mooring chain(s).4.3.2 Description of CP zone
Each CP zone may consist of several components which should be fully described including material, surface area
and coating characteristics (type, lifetime and coating breakdown factor).4.3.3 Service conditions
The design of the cathodic protection system(s) will depend on service conditions which include: lifetime,
environment and operating conditions.- Lifetime: Either the whole design life of the structure, the dry-docking or maintenance period(s) should be
considered.- Environment: The sea water properties should be established (see EN 12473).
- Operating conditions: the cathodic protection design normally considers only the static conditions of the structure
because the durations when dynamic conditions prevail are generally negligible.4.4 Electrical current demand
4.4.1 General
To achieve the protection criteria for the conditions outlined in 4.3 it is necessary to select the appropriate current
density for each component.The current demand of each metallic component of the structure is the result of the product of its surface area
multiplied by the required current density.---------------------- Page: 12 ----------------------
Page 11
EN 13174:2005
4.4.2 Protection current density for bare steel
The current density required may not be the same for all components of the structure as the environmental and
service conditions are variable.The selection of design current densities may be based on experiences gained from similar structures in a similar
environment or from specific tests and measurements.The current density depends on the kinetics of electrochemical reactions and varies with parameters such as the
protection potential, surface condition, dissolved oxygen in sea water, seawater velocity at the steel surface,
temperature.The following should be evaluated for each design:
- initial current density required to achieve initial polarisation of the structure;
- maintenance current density required to maintain polarisation of the structure;
- final current density for possible repolarisation of the structure, e.g. after severe storms or cleaning operations.
As the initial polarisation preceding steady state conditions is normally short compared to the design life, the average
current density over the lifetime of the structure is usually very close to the maintenance current density.
The (average) maintenance current density is used to calculate the minimum mass of the anode material necessary
to maintain cathodic protection throughout the design life.Typical values of current densities as used for bare steel are given in annex A.
4.4.3 Protection current density for coated steel
The cathodic protection system may be combined with suitable coating systems. The coating reduces current density
and improves the current distribution over the surface.The reduction of current density may be in a ratio of 100 to 1 or even more. However, the current density will increase
with time as the coating deteriorates.An initial coating breakdown factor related mainly to mechanical damage occurring during the fabrication of the
structure and installation should be considered. A coating deterioration rate (i.e. an increase of the coating breakdown
factor) should be selected in order to take into account the coating ageing and possible mechanical damage occurring
to the coating during the lifetime of the structure or corresponding to the dry-docking or maintenance period(s).
These values are strongly dependent on the actual construction and operational conditions.
Guidelines for the values of coating breakdown factors (f ) are given in annex A.
The current density needed for the protection of coated steel is equal to the product of the current density for the bare
steel and the coating breakdown factor.J = J · f
c b c
---------------------- Page: 13 ----------------------
Page 12
EN 13174:2005
where:
J is the protection current density for coated steel in amperes per square metres,
is the protection current density for bare steel in amperes per square metres,f is the coating breakdown factor which varies with time due to ageing and mechanical damage:
f = 0 for a perfectly insulating coating.f = 1 for a bare structure.
This formula should be applied for each individual component or zone as defined in 4.3 where the coating, or the
current density for bare steel, may be different.4.4.4 Protection current demand
An evaluation of the current demand required should be carried out to optimise the mass and size of galvanic anodes,
or the capacity of impressed current systems. The protection current demand I of each component of the structure to
be cathodically protected is equal to:I = A · J
e e ce
where:
A is the surface area of the individual zone in square metres,
J is the individual protection current density for the component considered in amperes per square metre.
The protection current demand I of each CP zone is therefore equal to the sum of current demand of each
component included in the CP zone:I = (I )
z z e
where:
I is the protection current demand of each component included in the CP zone in amperes.
NOTE For current demand determination, the highest astronomical tide should be considered.
An estimate of the current demand of chains which are not electrically insulated from the structure should be made
and added to I when applicable. This is necessary to ensure a safe cathodic protection design, even if the potential
achieved on the chains (and their protection) will depend on the actual q...
PROJET DE NORME INTERNATIONALE ISO/DIS 13174
Attribué à l'ISO/TC 156 par le Secrétariat central (voir page iii)
Début de vote Vote clos le
2005-04-05 2005-09-05
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
PROCÉDURE «VOIE EXPRESS»Protection cathodique des installations portuaires
Cathodic protection for harbour installations
ICS 47.020.99; 77.060
CE DOCUMENT EST UN PROJET DIFFUSÉ POUR OBSERVATIONS ET APPROBATION. IL EST DONC SUSCEPTIBLE DE MODIFICATION ET NE
PEUT ÊTRE CITÉ COMME NORME INTERNATIONALE AVANT SA PUBLICATION EN TANT QUE TELLE.
OUTRE LE FAIT D'ÊTRE EXAMINÉS POUR ÉTABLIR S'ILS SONT ACCEPTABLES À DES FINS INDUSTRIELLES, TECHNOLOGIQUES ET
COMMERCIALES, AINSI QUE DU POINT DE VUE DES UTILISATEURS, LES PROJETS DE GUIDES DOIVENT PARFOIS ÊTRE CONSIDÉRÉS DU
POINT DE VUE DE LEUR POSSIBILITÉ DE DEVENIR DES NORMES POUVANT SERVIR DE RÉFÉRENCE DANS LA RÉGLEMENTATION NATIONALE.
Organisation internationale de normalisation, 2005---------------------- Page: 1 ----------------------
ISO/DIS 13174
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.Notice de droit d'auteur
Ce document de l'ISO est un projet de Norme internationale qui est protégé par les droits d'auteur de l'ISO.
Sauf autorisé par les lois en matière de droits d'auteur du pays utilisateur, aucune partie de ce projet ISO
ne peut être reproduite, enregistrée dans un système d'extraction ou transmise sous quelque forme que ce
soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, les enregistrements ou
autres, sans autorisation écrite préalable.Les demandes d'autorisation de reproduction doivent être envoyées à l'ISO à l'adresse ci-après ou au
comité membre de l'ISO dans le pays du demandeur.ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Toute reproduction est soumise au paiement de droits ou à un contrat de licence.
Les contrevenants pourront être poursuivis.
ii © ISO 2005 — Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/DIS 13174
NOTE DU SECRÉTARIAT CENTRAL
Le présent projet de Norme internationale est soumis au vote des comités membres de l'ISO selon la
procédure par voie express.Le comité technique ISO/TC 156, Corrosion des métaux et alliages, à sa réunion de mai 2004, a décidé
d'approuver la soumission de la norme EN 13174:2001, Protection cathodique des installations portuaires,
selon la «procédure par voie express», conformément aux dispositions de l'Article F.2, Annexe F, des
Directives ISO/CEI, Partie 1 (quatrième édition, 2001).F.2 «Procédure par voie express»
F.2.1 Les propositions d'appliquer la procédure par voie express peuvent être soumises selon les règles
décrites ci-dessous.F.2.1.1 Tout membre (P) d'un comité technique concerné et toute organisation ayant un statut de liaison de
catégorie A auprès de ce comité peuvent proposer de soumettre directement au vote, en tant que projet pour
enquête, une norme existante de toute origine. L'auteur de la proposition doit obtenir l'accord de
l'organisation d'origine avant de faire la proposition. Il appartient à l'auteur de chaque proposition de décider des
critères permettant de proposer le traitement d'une norme existante selon la procédure par voie express.
F.2.1.2 Un organisme international ayant des activités normatives reconnu par le bureau du conseil de l'ISO ou
de la CEI peut proposer qu'une norme qu'il a établie lui-même soit soumise au vote comme projet final de
Norme internationale.F.2.1.3 Une organisation ayant passé un accord technique formel avec l'ISO ou la CEI peut proposer, en
accord avec le comité technique ou sous-comité concerné, qu'un projet de norme établi par cette
organisation soit soumis au vote comme projet pour enquête au sein du comité technique ou sous-comité.
F.2.2 La proposition doit être adressée au Secrétaire général qui doit prendre les dispositions suivantes:
a) régler, avec l'organisation à l'origine de la proposition, les questions de droit d'auteur et/ou de marques de
fabrique, de façon que le texte proposé puisse être librement reproduit et diffusé aux organismes nationaux;
b) déterminer, dans les cas F.2.1.1 et F.2.1.3, en concertation avec les secrétariats concernés, lequel des
comités techniques ou sous-comités est compétent pour le sujet traité dans le document proposé; dans le
cas où il n'existe aucun comité technique compétent pour traiter de l'objet du document en question, le
Secrétaire général doit présenter la proposition au bureau de gestion technique qui peut inviter le Secrétaire
général à soumettre le document au stade enquête et à créer un groupe ad hoc chargé de traiter des
questions qui surgiraient par la suite;c) s'assurer qu'il n'y a pas de contradiction manifeste avec d'autres Normes internationales;
d) diffuser le document proposé sous forme de projet pour enquête (F.2.1.1 et F.2.1.3) selon le paragraphe 2.6.1,
ou sous forme de projet final de Norme internationale (cas F.2.1.2) selon le paragraphe 2.7.1, en indiquant
(cas F.2.1.1 et F.2.1.3) le comité technique ou sous-comité dont relève le document proposé.
F.2.3 Le délai pour la procédure de vote et les conditions d'approbation sont spécifiés en 2.6 pour un projet
pour enquête ou 2.7 pour un projet final de Norme internationale. Dans le cas où aucun comité technique n'est
concerné, la condition d'approbation pour un projet final de Norme internationale est que moins d'un quart des
votes exprimés soit négatif.F.2.4 Si, pour un projet d'enquête, les conditions d'approbation sont réunies, le projet de norme doit avancer au
stade approbation (2.7). Si cela n'est pas le cas, la proposition échoue et la suite doit être déterminée par le
comité technique ou sous-comité à qui on a attribué le document selon F.2.2 b).Si, pour un projet final de Norme internationale, les conditions d'approbation sont réunies, le document doit
avancer au stade publication (2.8). Si cela n'est pas le cas, la proposition échoue et la suite doit être déterminée
par le comité technique ou sous-comité à qui on a attribué le projet final de Norme internationale selon F.2.2 b)
ou par discussion entre l'organisation d'origine et le bureau du Secrétaire général si aucun comité technique
n'est concerné.Si la norme est publiée, la maintenance de celle-ci doit être confiée au comité technique ou sous-comité auquel
on a attribué le document selon F.2.2 b), ou, si aucun comité technique n'était concerné, la procédure
d'approbation décrite ci-dessus doit être répétée si l'organisation d'origine décide que des modifications à la
norme sont nécessaires.© ISO 2005 — Tous droits réservés iii
---------------------- Page: 3 ----------------------
Page 2
EN 13174:2005
Sommaire
Avant-propos...............................................................................................................................................................3
Introduction .................................................................................................................................................................4
1 Domaine d’application...................................................................................................................................5
1.1 Parties structurales .......................................................................................................................................5
1.2 Matériaux ........................................................................................................................................................5
1.3 Environnement...............................................................................................................................................5
1.4 Sécurité et protection de l’environnement..................................................................................................5
2 Références normatives .................................................................................................................................5
3 Termes et définitions.....................................................................................................................................6
4 Base de calcul ................................................................................................................................................9
4.1 Objectifs..........................................................................................................................................................9
4.2 Critères de protection cathodique ...............................................................................................................9
4.3 Paramètres de calcul .....................................................................................................................................9
4.4 Détermination du besoin en courant .........................................................................................................10
4.5 Systèmes de protection cathodique ..........................................................................................................12
4.6 Continuité électrique ...................................................................................................................................13
4.7 Interactions...................................................................................................................................................13
5 Conception d’un système à courant imposé ............................................................................................13
5.1 Objectifs........................................................................................................................................................13
5.2 Considérations relatives à la conception..................................................................................................14
5.3 Considérations relatives à l’équipement...................................................................................................14
6 Conception d’un système à anodes galvaniques.....................................................................................16
6.1 Objectifs........................................................................................................................................................16
6.2 Considérations relatives à la conception..................................................................................................16
6.3 Facteurs déterminant le courant débité par anode et la durée de vie en service.................................17
6.4 Emplacement des anodes...........................................................................................................................18
7 Surveillance des systèmes de protection cathodique.............................................................................18
7.1 Objectifs........................................................................................................................................................18
7.2 Mesures du potentiel ...................................................................................................................................18
7.3 Mesurage du courant débité par une anode à courant imposé ..............................................................19
7.4 Régulation de la source du courant imposé .............................................................................................19
8 Documentation.............................................................................................................................................19
8.1 Objectifs........................................................................................................................................................19
8.2 Système à courant imposé .........................................................................................................................20
8.3 Système par anodes galvaniques ..............................................................................................................20
Annexe A (informative) Recommandations relatives aux besoins en matière de courant pour la
protection cathodique des installations portuaires .................................................................................21
A.1 Densités de courant d’étude pour la protection de l’acier nu en eau de mer .......................................21
A.2 Densités théoriques de courant pour la protection de l’acier nu dans les fonds marins (vase) ........21
A.3 Valeurs des coefficients de dégradation du revêtement des systèmes classiques de peinture,
pour le calcul des systèmes de protection cathodique...........................................................................21
Annexe B (informative) Résistance de l’anode et détermination de la durée de vie..........................................22
B.1 Formules relatives à la résistance des anodes (R ).................................................................................22
B.2 Durée de vie des anodes.............................................................................................................................23
Annexe C (informative) Caractéristiques électrochimiques types des anodes à courant imposé...................24
---------------------- Page: 4 ----------------------Page 3
EN 13174:2005
Avant-propos
La présente norme européenne a été élaborée par le Comité Technique CEN/TC 219 "Protection cathodique" dont
le secrétariat est tenu par le BSI.Cette norme européenne devra recevoir le statut de norme nationale, soit par publication d'un texte identique, soit
par entérinement, au plus tard en juillet 2001, et toutes les normes nationales en contradiction devront être retirées
au plus tard en juillet 2001.Selon le Règlement Intérieur du CEN/CENELEC, les instituts de normalisation nationaux des pays suivants sont
tenus de mettre cette norme européenne en application: Allemagne, Autriche, Belgique, Danemark, Espagne,
Finlande, France, Grèce, Irlande, Islande, Italie, Luxembourg, Norvège, Pays-Bas, Portugal, République Tchèque,
Royaume-Uni, Suède et Suisse.---------------------- Page: 5 ----------------------
Page 4
EN 13174:2005
Introduction
La protection cathodique, associée, le plus souvent, à un revêtement ou à une peinture de protection, est
habituellement utilisée pour protéger la surface externe des installations portuaires en acier et des parties annexes
contre la corrosion due à l’eau de mer ou aux fonds marins.La protection cathodique consiste à fournir une quantité suffisante de courant continu à la surface externe
immergée de la structure pour abaisser le potentiel de l’acier par rapport à l’électrolyte jusqu’à des valeurs où la
corrosion est insignifiante.Les principes généraux de la protection cathodique sont détaillés dans l’EN 12473.
---------------------- Page: 6 ----------------------Page 5
EN 13174:2005
1 Domaine d’application
La présente norme européenne définit les moyens à mettre en œuvre pour assurer la protection cathodique des
parties métalliques externes immergées et enfouies des installations portuaires en acier et de leurs parties
annexes contre la corrosion due à l’eau de mer ou aux fonds marins.1.1 Parties structurales
La présente norme européenne est applicable à la protection cathodique des structures fixes et flottantes. Ces
structures comprennent essentiellement : les appontements, jetées, bourrelets d’embarcation (d’amarrage et
d’accostage), les pieux d’écoute et les pieux tubulaires, les pontons, les bouées, les docks flottants, les portes
d’écluse et les vannes, etc.Elle est également applicable aux surfaces submergées des parties annexes fixées à la structure (par exemple les
chaînes) lorsqu’elles ne sont pas isolées électriquement de la structure.Elle n’est pas applicable à la protection cathodique des structures fixes ou flottantes en mer, des canalisations
sous-marines ou des bateaux.La présente norme européenne n’est pas applicable à la protection interne de la surface des composants tels que
les ballasts ou les surfaces intérieures des structures flottantes, ni à l’intérieur ou aux faces arrières des pieux
d’écoute en acier en contact avec le remblayage, etc.1.2 Matériaux
La présente norme européenne est applicable à la protection cathodique des structures réalisées principalement à
partir d’aciers au carbone/manganèse nus ou revêtus.Certaines parties de la structure pouvant être réalisées en matériaux métalliques autres que les aciers au
carbone/manganèse, il convient de concevoir le système de protection cathodique de manière à assurer une
parfaite maîtrise de tout couplage galvanique et à réduire au maximum les risques dus à la fragilisation ou à la
fissuration induite par l’hydrogène (voir l’EN 12473).La présente norme européenne n’est pas applicable aux structures en béton.
1.3 Environnement
La présente norme européenne est applicable à l’ensemble de la zone submergée en eau de mer, en eau
saumâtre, dans les fonds marins (vase), des structures constituant les installations portuaires, que ces structures
soient fixes ou flottantes.En ce qui concerne les surfaces qui sont immergées de façon intermittente, la protection cathodique n’est efficace
que lorsque le temps d’immersion est suffisamment long pour permettre la polarisation de l’acier.
1.4 Sécurité et protection de l’environnementLa présente norme européenne ne traite pas des aspects liés à la protection de l’environnement. Les
réglementations nationales ou internationales concernées doivent s’appliquer.2 Références normatives
Cette Norme européenne comporte par référence datée ou non datée des dispositions d'autres publications. Ces
références normatives sont citées aux endroits appropriés dans le texte et les publications sont énumérées
ci-après. Pour les références datées, les amendements ou révisions ultérieurs de l'une quelconque de ces
publications ne s'appliquent à cette Norme européenne que s'ils y ont été incorporés par amendement ou révision.
Pour les références non datées, la dernière édition de la publication à laquelle il est fait référence s'applique.
---------------------- Page: 7 ----------------------Page 6
EN 13174:2005
EN 12473, Principes généraux de la protection cathodique en eau de mer.
prEN 12496, Anodes galvaniques pour protection cathodique dans l’eau de mer.
3 Termes et définitions
Pour les besoins de la présente Norme européenne, les définitions de l’EN 12473 et les suivantes s'appliquent.
3.1zone émergée
zone située au-dessus de la zone d’éclaboussure, c’est-à-dire au-dessus du niveau atteint par la houle normale,
que la structure soit ou non en déplacement3.2
zone enfouie
zone située sous le fond vaseux
3.3
zone de Protection Cathodique (PCZ)
partie de la structure qui peut être considérée de façon indépendante et pour laquelle est conçu un système de
protection cathodique3.4
zone de marnage étendue
zone comprenant la zone de marnage, la zone d’éclaboussure et la zone enterrée (ensouillée)
3.5H.A.T.
niveau de la marée astronomique maximale
3.6
zone immergée
zone située en dessous de la zone de marnage étendue et au-dessus du fond vaseux ou ligne correspondant à un
tirant d’eau pour des conditions de travail normales3.7
L.A.T.
niveau de la marée astronomique minimale
3.8
M.T.L.
niveau moyen de la marée (également désigné par M.S.L. ou M.W.L.)
3.9
R.O.V.
véhicule télécommandé
3.10
pieu
élément tubulaire ou en feuilles d’acier profondément enfoncé dans le sol, faisant partie de l’ensemble de la
structure portuaire3.11
zone d’éclaboussure
hauteur située juste au-dessus du H.A.T. à laquelle la structure est mouillée par intermittence par les vagues
3.12zone submergée
zone comprenant la zone enfouie, la zone immergée et la zone de transition
---------------------- Page: 8 ----------------------
Page 7
EN 13174:2005
3.13
zone enterrée (ensouillée)
zone située sous le L.A.T. incluant l’écart éventuel de la structure par rapport à l’horizontalité dû à une teneur en
oxygène plus élevée en raison du phénomène des marées ou de gonflement---------------------- Page: 9 ----------------------
Page 8
EN 13174:2005
zone atmosphérique
zone d’éclaboussure
H.A.T.
Zone de
marnage
étendue
Zone de marnage
M.T.L.
L.A.T.
zone de transition
Zone Zone immergée
submergée
Fond vaseux
Zone enfouie
Figure 1 – Représentation schématique des niveaux et des zones dans un environnement d’eau de mer
---------------------- Page: 10 ----------------------Page 9
EN 13174:2005
4 Base de calcul
4.1 Objectifs
L’objectif principal d’un système de protection cathodique est de fournir une quantité suffisante de courant pour
protéger la structure et ses parties annexes en répartissant ce courant de telle sorte que le potentiel de chacune
des parties de la structure se situe à l’intérieur des limites définies par les critères de protection (voir 4.2).
Il convient que les potentiels soient aussi homogènes que possible sur l’ensemble de la structure. Ceci ne peut
être obtenu que par une répartition adéquate du courant de protection sur la structure dans les conditions normales
de service de celle-ci. Cet objectif de répartition homogène peut cependant se révéler difficile à atteindre dans
certaines zones, telles que les chaînes, pour lesquelles il convient d’envisager l’ajout d’un système de protection
cathodique supplémentaire.Le système de protection cathodique ou une structure fixe et flottante est généralement associé à un système de
revêtement, même si certaines parties annexes, telles que les chaînes, ne peuvent pas bénéficier d’un revêtement
de protection. Des détériorations sérieuses peuvent également se produire sur la partie enfouie des pieux mis en
place lors de l’installation.Un bouclier diélectrique peut être installé à proximité des anodes pour réduire le plus possible les risques de sur-
protection.Il convient de concevoir le système de protection cathodique soit en fonction de la durée de vie de la structure, soit
pour une période correspondant à l’intervalle de temps entre deux opérations d’entretien en cale sèche. Si la
structure ne permet pas la pose d’un système de protection permanent pendant toute la durée de vie ou pendant
l’intervalle de temps entre deux opérations d’entretien en cale sèche, il convient d’équiper la structure d’un système
de protection facile à remplacer par des plongeurs ou des véhicules télécommandés.
Il convient que la conception du système de protection cathodique permette d’atteindre ces objectifs en utilisant
soit des anodes galvaniques, soit des anodes à courant imposé, soit une combinaison des deux méthodes.
4.2 Critères de protection cathodiqueLes critères de protection cathodique sont décrits de façon détaillée dans l’EN 12473.
Pour que le niveau de protection cathodique atteint soit suffisant, il convient que les potentiels de protection des
structures en acier soient conformes à ceux indiqués ci-après.Le critère adopté pour la protection cathodique de l’acier dans l’eau de mer aérée correspond à un potentiel plus
négatif que –0,80 V, mesuré par rapport à une électrode de référence argent/chlorure d’argent/eau de mer
(électrode de référence Ag/AgCl/eau de mer).Cependant, pour les structures en acier immergées dans une eau contenant des sulfates actifs destinés à réduire
la croissance bactérienne (conditions anaérobies), un potentiel plus négatif que – 0 ,90 V (électrode de référence
Ag/AgCl/Eau de mer) est habituellement recommandé en raison d’un risque de corrosion microbiologique réel.
Pour les structures revêtues, un potentiel plus négatif que –1,10 V (mesuré par rapport à une électrode de
référence Ag/AgCl/eau de mer) est recommandé.Pour tenir comte des risques de fatigue-corrosion, il convient parfois de prévoir une limite inférieure moins négative
en fonction des caractéristiques des matériaux. Le choix de cette limite négative doit être dûment justifié dans la
documentation.4.3 Paramètres de calcul
Il convient d’étudier la conception du système de protection cathodique en fonction des paramètres suivants :
subdivision de la structure, description des composants et conditions de service.
---------------------- Page: 11 ----------------------Page 10
EN 13174:2005
4.3.1 Subdivision de la structure
Les structures portuaires à protéger peuvent être subdivisées en différentes zones de Protection Cathodique
(PCZ), qui peuvent ensuite être considérées de façon indépendante, pour l’étude de la protection cathodique, bien
qu’il ne soit pas nécessaire de les isoler électriquement les unes des autres.EXEMPLE 1 Dans le cas d’un bourrelet d’embarcation, la zone du pieu peut être divisée en deux zones de protection
cathodique bien distinctes : la zone immergée et la zone enfouie. Cette distinction est justifiée par le besoin élevé en courant de
la zone immergée, en raison de la vitesse du mouvement de l’eau, de sa salinité, de sa teneur en oxygène et de sa
température. Le besoin en courant de la zone enfouie est moins élevé, ceci en raison de l’environnement. Certains éléments
spécifiques peuvent ne pas être inclus dans la PCZ et constituer à son tour une PCZ spécifique (par exemple, les prises d’eau
de mer).EXEMPLE 2 Dans le cas de bouées, une seule zone suffit généralement à couvrir le corps de la bouée et la partie de la ou
des chaînes d’amarrage sur laquelle la protection cathodique peut porter.4.3.2 Description des zones de protection cathodique
Chaque PCZ peut être constituée de plusieurs composants, il convient d’en donner une description complète, à
savoir les surfaces et les caractéristiques des matériaux et des revêtements (type, durée de vie et coefficient de
dégradation).4.3.3 Conditions de service
La conception du ou des systèmes de protection cathodique utilisé(s) est fonction des conditions de service : la
durée de vie prévue, l’environnement et les conditions de fonctionnement.Durée de vie : On considère, en général, soit la durée de vie complète de la structure, soit le ou les intervalles
de temps entre deux opérations d’entretien en cale sèche ;Environnement : Il est recommandé de déterminer les propriétés de l’eau de mer (voir l’EN 12473) ;
Conditions de fonctionnement : En général, la conception du système de protection cathodique tient
uniquement compte des conditions de fonctionnement de la structure à l’arrêt, le laps de temps pendant lequel
règnent des conditions de déplacement étant généralement négligeable.4.4 Détermination du besoin en courant
4.4.1 Généralités
Pour satisfaire aux critères de protection pour les conditions définies en 4.3, il est nécessaire de sélectionner pour
chacun des composants la densité de courant appropriée.Le besoin en courant de chaque composant métallique de la structure est estimé en multipliant la surface par la
densité de courant requise.4.4.2 Densité du courant de protection dans le cas de l’acier nu
La densité (moyenne) de courant de maintien nécessaire peut ne pas être la même pour tous les composants de la
structure, dans la mesure où les conditions d’environnement et de service sont variables.
Il est possible de choisir les densités de courant en se basant soit sur l’expérience acquise avec d’autres structures
installées dans le même environnement soit sur des essais et des mesurages.La densité du courant dépend de la cinétique des réactions électrochimiques et varie en fonction de paramètres
tels que le potentiel de protection, l’état de surface, la teneur en oxygène dissous dans l’eau de mer, la vitesse de
l’eau de mer à la surface de l’acier, la température, etc..---------------------- Page: 12 ----------------------
Page 11
EN 13174:2005
Pour chaque étude, il convient d’évaluer :
la densité de courant initiale, nécessaire pour obtenir la polarisation initiale de la structure ;
la densité de courant de maintien, nécessaire pour maintenir le niveau de polarisation sur la structure ;
la densité de courant finale requise pour une éventuelle repolarisation de la structure, suite à des tempêtes
sévères ou à des opérations de nettoyage, par exemple.La période de polarisation initiale précédant les conditions de service normales étant habituellement plus courte si
on la compare à la durée de vie théorique, la valeur moyenne de la densité de courant est généralement très
voisine de la densité du courant de maintien.Pour assurer une protection cathodique constante pendant toute la durée de vie théorique de la structure, on
calcule la masse minimale du matériau anodique nécessaire en fonction de la densité (moyenne) du courant de
maintien.Des valeurs typiques de densités de courant p
...
Questions, Comments and Discussion