Thermoplastics pipes for the transport of liquids under pressure — Calculation of head losses

Gives a method of calculating head loss in the transport of liquids under pressure in hydraulically smooth thermoplastic pipes. The formulae given (for calculating head drop and head loss, for temperature correction) apply to the transport of water under pressure, or to all other liquids of the same dynamic viscosity, at temperatures of up to 45 °C.

Tubes en matières thermoplastiques pour le transport de liquides sous pression — Calcul des pertes de charge

Plastomerne cevi za transport tekočin pod tlakom - Izračun tlačnih izgub

General Information

Status
Published
Publication Date
22-Dec-1993
Current Stage
9093 - International Standard confirmed
Completion Date
12-Jul-2022

Buy Standard

Technical report
ISO/TR 10501:1993 - Thermoplastics pipes for the transport of liquids under pressure -- Calculation of head losses
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical report
ISO/TR 10501:1995
English language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Technical report
ISO/TR 10501:1993 - Tubes en matieres thermoplastiques pour le transport de liquides sous pression -- Calcul des pertes de charge
French language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical report
ISO/TR 10501:1993 - Tubes en matieres thermoplastiques pour le transport de liquides sous pression -- Calcul des pertes de charge
French language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

TECHNICAL
ISO
REPORT
TR 10501
First edition
1993-12-15
Thermoplastics pipes for the transport of
liquids under pressure - Calculation of
head losses
Tubes en matieres thermoplastiques pour Ie transport de liquides sous
Pression - Calcul des pertes de Charge
Reference number
ISO/TR 10501:1993(E)

---------------------- Page: 1 ----------------------
ISO/TR 10501:1993(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be re-
presented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
The main task of technical committees is to prepare International Stan-
dards, but in exceptional circumstances a technical committee may pro-
pose the publication of a Technical Report of one of the following types:
- type 1, when the required support cannot be obtained for the publica-
tion of an International Standard, despite repeated efforts;
- type 2, when the subject is still under technical development or where
for any other reason there is the future but not immediate possibility
of an agreement on an International Standard;
- type 3, when a technical committee has collected data of a different
kind from that which is normally published as an International Standard
(“state of the art”, for example).
Technical Reports of types 1 and 2 are subject to review within three years
of publication, to decide whether they tan be transformed into Interna-
tional Standards. Technical Reports of type 3 do not necessarily have to
be reviewed until the data they provide are considered to be no longer
valid or useful.
lSO/rR 10501, which is a Technical Report of type 3, was prepared by
Technical Committee lSO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids, Sub-Committee SC 2, Plastics pipes and fittings for
wa ter supplies.
0 ISO 1993
All rights reserved. No part of this publication may be reproduced or utilized in any form or
by any means, electronie or mechanical, including photocopying and microfilm, without per-
mission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-l 211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
TECHNICAL REPORT ISO/TR 10501 :1993(E)
Thermoplastics pipes for the transport of liquids under
Calculation of head losses
pressure -
1 Scope 2.5 head loss, Ah : Change in pressure head
between two sections of a horizontal pipe due to
This Technical Report gives a method sf liquid flow through the Pipe.
calculating head loss in the transpoft of Iiquids
hydraulically smooth
under pressure in 2.6 head drop, J : Head loss per unit length of
.
thermoplastics pipes.
Pipe
The formulae given in the Technical Report apply
3 Symbols and units
to the transport of water under pressure, or to all
other liquids of the Same dynamic viscosity, at The Symbols and units used in this Technical
temperatures of up to 45%.
Report are given in Table 1.
2 Definitions
Table 1
For the purposes of this Technical Report, the
Sub- Quant ity Symbol Unit
following definitions apply.
clause
21 . Flowrate m3/h
: Volume of water flowing qv
2.1 flowrate, qv
through the pipe per unit time.
V mk
23 . Average velocity
24 . Average internal d m
2.2 steady flow : Flow in which the flowrate
diameter
through a measuring section does not vary with
time.
. Head loss m
25 Ah
. J
26 Head drop m/m
2.3 average velocity, v : Flowrate through the
pipe divided by the reference Cross-section of the Re
41 . Reynolds dimension-
Pipe. lt is calculated by dividing the actual number less
flowrate through the pipe by the Cross-section of
V
41 . Kinematic m2/s
the Pipe.
viscosity
m
42 . Pipe length 1
2.4 reference Cross-section of the Pipe, A :
Area of the circle with a diameter equal to the 0
t
C
43 . Temperature of
average internal diameter of the Pipe. The free
liquid
Cross-sectional area of the pipe is calculated from
43 . Temperatu re k dimension-
the inside diameter of the Pipe. t
correction factor less

---------------------- Page: 3 ----------------------
ISOTTR 10501 :1993(E)
4 Method of calculatisn Exponent b has the following values:
a) when the Reynolds number lies within the
4.1 Formulae for calculating head drop
range
4.1.1 The head drop for water, J,, in metres per
4 x 103 1< Re < 45 x 10’ :
metre, at a temperature of 20°C, is calculated
using one of the following formulae:
b = 0,24
4.1.1.1 Where the Reynolds numberl) lies within
b) when the Reynolds number lies within the
the range
range
4 x 103 5 Re < 45 x 10’ :
1,5 x 105 < Re 2 106 :
-
b
J 5,37 x 104(d-1924V1q76) = 0,20
0 -
4.1.1.2 Where the Reynolds numberl) lies within
4.2 Formula for calculating hea
...

SLOVENSKI STANDARD
SIST ISO/TR 10501:1995
01-november-1995
3ODVWRPHUQHFHYL]DWUDQVSRUWWHNRþLQSRGWODNRP,]UDþXQWODþQLKL]JXE
Thermoplastics pipes for the transport of liquids under pressure -- Calculation of head
losses
Tubes en matières thermoplastiques pour le transport de liquides sous pression -- Calcul
des pertes de charge
Ta slovenski standard je istoveten z: ISO/TR 10501:1993
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
SIST ISO/TR 10501:1995 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO/TR 10501:1995

---------------------- Page: 2 ----------------------

SIST ISO/TR 10501:1995
TECHNICAL
ISO
REPORT
TR 10501
First edition
1993-12-15
Thermoplastics pipes for the transport of
liquids under pressure - Calculation of
head losses
Tubes en matieres thermoplastiques pour Ie transport de liquides sous
Pression - Calcul des pertes de Charge
Reference number
ISO/TR 10501:1993(E)

---------------------- Page: 3 ----------------------

SIST ISO/TR 10501:1995
ISO/TR 10501:1993(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be re-
presented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
The main task of technical committees is to prepare International Stan-
dards, but in exceptional circumstances a technical committee may pro-
pose the publication of a Technical Report of one of the following types:
- type 1, when the required support cannot be obtained for the publica-
tion of an International Standard, despite repeated efforts;
- type 2, when the subject is still under technical development or where
for any other reason there is the future but not immediate possibility
of an agreement on an International Standard;
- type 3, when a technical committee has collected data of a different
kind from that which is normally published as an International Standard
(“state of the art”, for example).
Technical Reports of types 1 and 2 are subject to review within three years
of publication, to decide whether they tan be transformed into Interna-
tional Standards. Technical Reports of type 3 do not necessarily have to
be reviewed until the data they provide are considered to be no longer
valid or useful.
lSO/rR 10501, which is a Technical Report of type 3, was prepared by
Technical Committee lSO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids, Sub-Committee SC 2, Plastics pipes and fittings for
wa ter supplies.
0 ISO 1993
All rights reserved. No part of this publication may be reproduced or utilized in any form or
by any means, electronie or mechanical, including photocopying and microfilm, without per-
mission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-l 211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 4 ----------------------

SIST ISO/TR 10501:1995
TECHNICAL REPORT ISO/TR 10501 :1993(E)
Thermoplastics pipes for the transport of liquids under
Calculation of head losses
pressure -
1 Scope 2.5 head loss, Ah : Change in pressure head
between two sections of a horizontal pipe due to
This Technical Report gives a method sf liquid flow through the Pipe.
calculating head loss in the transpoft of Iiquids
hydraulically smooth
under pressure in 2.6 head drop, J : Head loss per unit length of
.
thermoplastics pipes.
Pipe
The formulae given in the Technical Report apply
3 Symbols and units
to the transport of water under pressure, or to all
other liquids of the Same dynamic viscosity, at The Symbols and units used in this Technical
temperatures of up to 45%.
Report are given in Table 1.
2 Definitions
Table 1
For the purposes of this Technical Report, the
Sub- Quant ity Symbol Unit
following definitions apply.
clause
21 . Flowrate m3/h
: Volume of water flowing qv
2.1 flowrate, qv
through the pipe per unit time.
V mk
23 . Average velocity
24 . Average internal d m
2.2 steady flow : Flow in which the flowrate
diameter
through a measuring section does not vary with
time.
. Head loss m
25 Ah
. J
26 Head drop m/m
2.3 average velocity, v : Flowrate through the
pipe divided by the reference Cross-section of the Re
41 . Reynolds dimension-
Pipe. lt is calculated by dividing the actual number less
flowrate through the pipe by the Cross-section of
V
41 . Kinematic m2/s
the Pipe.
viscosity
m
42 . Pipe length 1
2.4 reference Cross-section of the Pipe, A :
Area of the circle with a diameter equal to the 0
t
C
43 . Temperature of
average internal diameter of the Pipe. The free
liquid
Cross-sectional area of the pipe is calculated from
43 . Temperatu re k dimension-
the inside diameter of the Pipe. t
correction factor less

---------------------- Page: 5 ----------------------

SIST ISO/TR 10501:1995
ISOTTR 10501 :1993(E)
4 Method of calculatisn Exponent b has the following values:
a) when the Reynolds nu
...

RAPPORT
ISO
TECHNIQUE
TR 10501
Premiére édition
1993-l 2-l 5
Tubes en matières thermoplastiques pour
le transport de liquides sous pression -
Calcul des pertes de charge
Thermoplastics pipes for the transport of liquids under pressure -
Calculation of head losses
Numéro de référence
ISO/TR 10501 :1993(F)

---------------------- Page: 1 ----------------------
ISO/TR 10501:1993(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une
étude a le droit de faire partie du comité technique créé à cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
La tâche principale des comités techniques est d’élaborer les Normes
internationales, mais, exceptionnellement, un comité technique peut pro-
poser la publication d’un rapport technique de l’un des types suivants:
- type 1, lorsque, en dépit de maints efforts, l’accord requis ne peut être
réalisé en faveur de la publication d’une Norme internationale;
- type 2, lorsque le sujet en question est encore en cours de dévelop-
pement technique ou lorsque, pour toute autre raison, la possibilité
d’un accord pour la publication d’une Norme internationale peut être
envisagée pour l’avenir mais pas dans l’immédiat;
- type 3, lorsqu’un comité technique a reuni des données de nature dif-
férente de celles qui sont normalement publiées comme Normes
internationales (ceci pouvant comprendre des informations sur l’état
de la technique, par exemple).
Les rapports techniques des types 1 et 2 font l’objet d’un nouvel examen
trois ans au plus tard après leur publication afin de decider éventuellement
de leur transformation en Normes internationales. Les rapports techniques
du type 3 ne doivent pas nécessairement être révises avant que les don-
nées fournies ne soient plus jugées valables ou utiles.
L’ISO/rR 10501, rapport technique du type 3, a eté élaboré par le comité
technique lSO/TC 138, Tubes, raccords et robinetterie en matières plasti-
ques pour le transport des fluides, sous-comité SC 2, Tubes et raccords
en matigres plastiques pour adduction et distribution d’eau.
8 ISO 1993
Droits de reproduction réservés. Aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-l 211 Genève 20 l Suisse
Imprimé en Suisse
ii

---------------------- Page: 2 ----------------------
RAPPORT TECHNIQUE ISO/TR 10501:1993(F)
Tubes en matières thermoplastiques pour le transport de
- Calcul des pertes de charge
liquides sous pression
1 Domaine d’application 2.3 vitesse moyenne, v : Quotient du débit
dans le tube par sa section droite de référence.
Le présent Rapport technique donne une Cette vitesse est calculée en divisant le débit réel
méthode de calcul des pertes de charge lors du
dans le tube par la section droite de ce tube.
transport de liquides, sous pression, dans des
tubes en matières thermoplastiques lisses du
2.4 section droite de référence du tube, A :
point de vue hydraulique.
Surface du cercle de diamètre égal au diamètre
intérieur moyen du tube. La surface libre de la
Les formules données dans le présent Rapport
section droite du tube est calculée à l’aide du
technique s’appliquent au transport d’eau sous
diamètre intérieur de ce tube.
pression, ou a tout autre liquide de même
viscosité dynamique, à des températures
2.5 perte de charge, Ah : Variation de
inférieures à 45OC.
pression, entre deux sections d’un tube
horizontal, due à l’écoulement d’un liquide dans
2 Définitions ce tube.
Pour les besoins du présent Rapport technique, 2.6 perte de charge unitaire, J : Perte de
les définitions suivantes s’appliquent. charge par unité de longueur du tube.
2.1 vitesse d%coulement; débit, qv : Volume
3 Symboles et unités
d’eau qui s’écoule dans le tube par unité de
temps.
Les symboles et unités utilisés dans le présent
sont donnés dans le
Rapport technique
2.2 écoulement stable : lkoulement selon
tableau 1.
lequel le débit dans la section de mesure ne varie
pas avec le temps.
1

---------------------- Page: 3 ----------------------
ISO/TR 10501:1993(F)
Tableau 1 4.1.1.2 Si le nombre de Reynoldsl) est dans la
gamme
Grandeur Symbole Unité
Paragraphe
1,5 x 105 < Ke < 106 :
21 . Débit m3/h
qv
-
J $79 x 104 ( d-ly2’ vlT8’)
0 -
23 . Vitesse moyenne v m/s
24 . Diamètre d m
intérieur moyen
NOTE 1 - Les différentes formules généralement
25 . Perte de charge Ah m
utilisées pour calculer les pertes de charge dans les
tubes sont données dans l’annexe A.
26 . Perte de charge J m/m
unitaire
Re
41 . Nombre de sans
4.1.2 La perte de charge unitaire J, pour un
Reynolds dimension
liquide x qui diffère de l’eau est calculée à l’aide
V
de la formule suivante :
41 . Viscosité m*/s
cinématique
b
42 . Longueur du m
1
tube
0
43 . Température du t C
fluide où
43 . Facteur de k sans
t
J, est la perte de charge unitaire pour un liquide
correction de la dimension
donné;
température
Jo est la perte de charge unitaire pour l’eau à
20°C;
4 Méthode de calcul
est la viscosité cinématique d’un liquide
vX
donné à la température désirée;
4.1 Formules de calcul de la perte de charg
...

RAPPORT
ISO
TECHNIQUE
TR 10501
Premiére édition
1993-l 2-l 5
Tubes en matières thermoplastiques pour
le transport de liquides sous pression -
Calcul des pertes de charge
Thermoplastics pipes for the transport of liquids under pressure -
Calculation of head losses
Numéro de référence
ISO/TR 10501 :1993(F)

---------------------- Page: 1 ----------------------
ISO/TR 10501:1993(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une
étude a le droit de faire partie du comité technique créé à cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
La tâche principale des comités techniques est d’élaborer les Normes
internationales, mais, exceptionnellement, un comité technique peut pro-
poser la publication d’un rapport technique de l’un des types suivants:
- type 1, lorsque, en dépit de maints efforts, l’accord requis ne peut être
réalisé en faveur de la publication d’une Norme internationale;
- type 2, lorsque le sujet en question est encore en cours de dévelop-
pement technique ou lorsque, pour toute autre raison, la possibilité
d’un accord pour la publication d’une Norme internationale peut être
envisagée pour l’avenir mais pas dans l’immédiat;
- type 3, lorsqu’un comité technique a reuni des données de nature dif-
férente de celles qui sont normalement publiées comme Normes
internationales (ceci pouvant comprendre des informations sur l’état
de la technique, par exemple).
Les rapports techniques des types 1 et 2 font l’objet d’un nouvel examen
trois ans au plus tard après leur publication afin de decider éventuellement
de leur transformation en Normes internationales. Les rapports techniques
du type 3 ne doivent pas nécessairement être révises avant que les don-
nées fournies ne soient plus jugées valables ou utiles.
L’ISO/rR 10501, rapport technique du type 3, a eté élaboré par le comité
technique lSO/TC 138, Tubes, raccords et robinetterie en matières plasti-
ques pour le transport des fluides, sous-comité SC 2, Tubes et raccords
en matigres plastiques pour adduction et distribution d’eau.
8 ISO 1993
Droits de reproduction réservés. Aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-l 211 Genève 20 l Suisse
Imprimé en Suisse
ii

---------------------- Page: 2 ----------------------
RAPPORT TECHNIQUE ISO/TR 10501:1993(F)
Tubes en matières thermoplastiques pour le transport de
- Calcul des pertes de charge
liquides sous pression
1 Domaine d’application 2.3 vitesse moyenne, v : Quotient du débit
dans le tube par sa section droite de référence.
Le présent Rapport technique donne une Cette vitesse est calculée en divisant le débit réel
méthode de calcul des pertes de charge lors du
dans le tube par la section droite de ce tube.
transport de liquides, sous pression, dans des
tubes en matières thermoplastiques lisses du
2.4 section droite de référence du tube, A :
point de vue hydraulique.
Surface du cercle de diamètre égal au diamètre
intérieur moyen du tube. La surface libre de la
Les formules données dans le présent Rapport
section droite du tube est calculée à l’aide du
technique s’appliquent au transport d’eau sous
diamètre intérieur de ce tube.
pression, ou a tout autre liquide de même
viscosité dynamique, à des températures
2.5 perte de charge, Ah : Variation de
inférieures à 45OC.
pression, entre deux sections d’un tube
horizontal, due à l’écoulement d’un liquide dans
2 Définitions ce tube.
Pour les besoins du présent Rapport technique, 2.6 perte de charge unitaire, J : Perte de
les définitions suivantes s’appliquent. charge par unité de longueur du tube.
2.1 vitesse d%coulement; débit, qv : Volume
3 Symboles et unités
d’eau qui s’écoule dans le tube par unité de
temps.
Les symboles et unités utilisés dans le présent
sont donnés dans le
Rapport technique
2.2 écoulement stable : lkoulement selon
tableau 1.
lequel le débit dans la section de mesure ne varie
pas avec le temps.
1

---------------------- Page: 3 ----------------------
ISO/TR 10501:1993(F)
Tableau 1 4.1.1.2 Si le nombre de Reynoldsl) est dans la
gamme
Grandeur Symbole Unité
Paragraphe
1,5 x 105 < Ke < 106 :
21 . Débit m3/h
qv
-
J $79 x 104 ( d-ly2’ vlT8’)
0 -
23 . Vitesse moyenne v m/s
24 . Diamètre d m
intérieur moyen
NOTE 1 - Les différentes formules généralement
25 . Perte de charge Ah m
utilisées pour calculer les pertes de charge dans les
tubes sont données dans l’annexe A.
26 . Perte de charge J m/m
unitaire
Re
41 . Nombre de sans
4.1.2 La perte de charge unitaire J, pour un
Reynolds dimension
liquide x qui diffère de l’eau est calculée à l’aide
V
de la formule suivante :
41 . Viscosité m*/s
cinématique
b
42 . Longueur du m
1
tube
0
43 . Température du t C
fluide où
43 . Facteur de k sans
t
J, est la perte de charge unitaire pour un liquide
correction de la dimension
donné;
température
Jo est la perte de charge unitaire pour l’eau à
20°C;
4 Méthode de calcul
est la viscosité cinématique d’un liquide
vX
donné à la température désirée;
4.1 Formules de calcul de la perte de charg
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.