This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of fittings made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.6 of this document. Components manufactured for water for other purposes, drainage and sewerage are possibly not suitable for water supply for human consumption.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with Parts 1, 2, 4 and 5 of EN 12201, it is applicable to PE fittings, their joints and to joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  );
b)   an operating temperature of 20 °C as a reference temperature;
c)   buried in the ground;
d)   sea outfalls;
e)   laid in water;
f)   above ground, including pipes suspended below bridges.
NOTE 2   For applications operating at constant temperature greater than 20 °C and up to 40 °C, see prEN 12201 1:2021, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 3   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
These fittings can be of the following types:
a)   fusion fittings;
1)   electrofusion fittings;
2)   spigot end fittings (for butt fusion using heated tools and electrofusion socket fusion);
3)   socket fusion fittings (see Annex A);
b)   mechanical fittings;
1)   compression fittings;
2)   flanged fittings;
c)   fabricated fittings (see Annex B).

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies materials and the general aspects of polyethylene (PE) pressure piping systems (mains and service pipes) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1   For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment attention is drawn to Clause 6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [6].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-2, EN 12201 3, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  ;
b)   an operating temperature of 20 °C as a reference temperature.
NOTE 3   For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of valves or valve bodies made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes.
It is applicable to isolating unidirectional and bi-directional valves with spigot ends or electrofusion sockets intended to be fused with PE pipes or fittings conforming to prEN 12201 2 and prEN 12201 3 respectively.
Valves made from materials other than PE, designed for the supply of water, drainage and sewerage under pressure conforming to the relevant standards can be used in PE piping systems according to EN 12201, provided that they have PE connections for butt fusion or electrofusion ends, including integrated material transition joints, conforming to prEN 12201 3.
NOTE 1   For valves or valve bodies intended for drainage and sewerage under pressure, additional specifications/tests could be necessary according to the requirements of the purchaser, especially for the chemical resistance of the components in contact with the fluids and functioning characteristics.
NOTE 2   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to 5.4. Components manufactured for water for other purposes are possibly not suitable for water supply for human consumption.
It also specifies the test parameters for the test methods referred to in this document.
NOTE 3   Valves made from material other than polyethylene (PE) designed for the supply of water intended for human consumption to a relevant standard(s) can be used in PE piping systems conforming to EN 12201 when they have relevant PE connection for butt fusion or electrofusion ends (see prEN 12201 3:2021).
In conjunction with Parts 1, 2, 3 and 5 of EN 12201 it is applicable to PE valves, their joints and to joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar );
b)   an operating temperature of 20 °C as a reference temperature;
c)   buried in the ground;
d)   sea outfalls;
e)   laid in water;
f)   above ground, including pipes suspended below bridges.
NOTE 4   For applications operating at constant temperature greater than 20 °C and up to 40 °C, see prEN 12201 1:2021, Annex A.
EN 12201 covers a range of allowable operating pressures and gives requirements concerning colours and additives.
NOTE 5   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
This Part of EN 12201 covers valves for pipes with a nominal outside diameter dn ≤ 400 mm.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of pipes made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to 6.3 of this document. Components manufactured for water for general purposes, drainage and sewerage are possibly not suitable for water supply for human consumption.
For use in contaminated soils special consideration is taken for pipes intended for the transport of water intended for human consumption or raw water prior to treatment.
NOTE 2   Pipes constructions including barrier layers are not covered by this document. ISO 21004 provides an alternative solution for use in contaminated soils [9].
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with Part 1 and Parts 3 to 5 of EN 12201, it is applicable to PE pipes, their joints and to joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  );
b)   an operating temperature of 20 °C as a reference temperature;
c)   buried in the ground;
d)   sea outfalls;
e)   laid in water;
f)   above ground, including pipes suspended below bridges.
NOTE 3   For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see prEN 12201-1:2021, Annex A
EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
This document specifies three types of pipe:
—   PE pipes (outside diameter dn) including any identification stripes;
—   PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) as specified in Annex B, where all layers have the same MRS rating. A coextruded pipe made of a combination of PE 100 and PE 100-RC layers are regarded as PE 100 and marked accordingly.
—   PE pipes (outside diameter dn) with a peelable, contiguous thermoplastics additional layer on the outside of the pipe (‘coated pipe’) as specified in Annex C.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
NOTE 5   Assessment of the resistance to slow crack growth of the PE pipe compound used for the manufacture of products to this document is required in accordance with prEN 12201-1:2021, Table 2.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of the fitness for purpose of the assembled piping systems intended for the conveyance of water intended for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes.
It also specifies the method of preparation of test piece joints, and the tests to be carried out on these joints for assessing the fitness for purpose of the system under normal and extreme conditions.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to the introduction of this document. Components manufactured for water for other purposes are possibly not suitable for water supply for human consumption.
It specifies the test parameters for the test methods referred to in this document.
NOTE 2   This document is intended only to be used by the product manufacturer to assess the performance of components according to prEN 12201 2, prEN 12201 3, or prEN 12201 4 when joined together under normal and extreme conditions. It is not intended for on-site testing of pipe systems.
In conjunction with Parts 1 to 4 of prEN 12201 it is applicable to PE pipes, fittings, valves, their joints and to joints with components of other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar );
b)   an operating temperature of 20 °C as a reference temperature for design purposes;
c)   buried in the ground;
d)   sea outfalls;
e)   laid in water;
f)   above ground, including pipes suspended below bridges.
NOTE 3   For applications operating at constant temperatures greater than 20 °C up to 40 °C, see prEN 12201 1:2021, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) solid wall piping intended to be used underground or above-ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document. This document is not intended for on-site testing of pipe systems. In conjunction with ISO 16422-1, ISO 16422-2, ISO/TS 16422-3 and ISO 1452-3, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar= 0,1 MPa = 105 Pa; 1 MPa= 1 N/mm2

  • Standard
    11 pages
    English language
    sale 15% off

This document specifies the general characteristics of solid-wall pipes made of oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended to be used underground or above-ground (where protected from direct sunlight), for water supply, buried drainage, sewerage, treated waste water and irrigation under pressure. In conjunction with ISO 16422-2, ISO/TS 16422-3, ISO 16422-5 and ISO 1452-4, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to valves, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2

  • Standard
    8 pages
    English language
    sale 15% off

This document specifies the characteristics of solid-wall pipes made of oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended to be used underground or above-ground (where protected from direct sunlight), for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document. In conjunction with ISO 16422-1 and ISO 16422-5, this document is applicable to oriented PVC-O pipes, with or without integral socket, intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2

  • Standard
    25 pages
    English language
    sale 15% off

This document specifies requirements for materials used in vulcanized rubber seals for the following: a) cold drinking-water supplies (up to 50 °C); b) drainage, sewerage, and rainwater systems (continuous flow up to 45 °C and intermittent flow up to 95 °C). The different designations of seals specified are defined according to their type, application, and requirements (see Table 5). General requirements for finished joint seals are also given; any additional requirements called for by the particular application are specified in the relevant product standards, taking into account that the performance of pipe joints is a function of the seal material properties, seal geometry, and pipe joint design. This document is intended to be used, where appropriate, with product standards which specify performance requirements for joints. This document is applicable to joint seals for all pipeline materials, including iron, steel, clay, fibre cement, concrete, reinforced concrete, plastics, and glass-reinforced plastics. It is applicable to elastomeric components of composite or non-composite seals. In the case of composite seals for materials of hardness ranges from 76 IRHD-M to 95 IRHD-M, the requirements for elongation at break, compression set, and stress relaxation apply only when the material is participating in the sealing function or in the long-term stability of the seal. Joint seals made with an enclosed void as part of their design are included in the scope of this document.

  • Standard
    14 pages
    English language
    sale 15% off

This document specifies general construction, performance and material requirements for the tapware FRT, PN 10. The application in the drinking water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
The conditions of use are according to the following Table 1:
[Table 1 - Conditions of use]
[Figure 1 - The different areas of FRT]

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance on the assessment of conformity of GRP-UP (glass-reinforced thermosetting resins based on unsaturated polyesters) piping products and assemblies in accordance with EN 1796 and EN 14364 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures. This Technical Specification also gives guidance on the assessment of conformity of GRP-UP manholes and inspection chambers in accordance with prEN 15383. Pipes according to EN 14364 are used for manufacturing the shafts and chamber units. Additional statements as needed to assess the conformity of manholes and inspection chambers are given in Annex F. NOTE 1 It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [3]. NOTE 2 If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [1], EN 45012 [2] or EN ISO/IEC 17021 [5], as applicable.

  • Technical specification
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance on the assessment of conformity of GRP-UP (glass-reinforced thermosetting resins based on unsaturated polyesters) piping products and assemblies in accordance with EN ISO 23856. ISO 25780 and ISO 16611 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
This document also gives guidance on the assessment of conformity of GRP-UP manholes and inspection chambers (see EN 15383 for additional information). Pipes (see EN ISO 23856) are used for manufacturing the shafts and chamber units. Additional statements as needed to assess the conformity of manholes and inspection chambers are given in Annex F.
NOTE 1   For the purpose of this document, the term polyester resin (UP) also includes vinyl-ester resins (VE).
NOTE 2   If third-party certification is involved, the certification body is accredited to ISO/IEC 17065 or EN ISO/IEC 17021 [3] as applicable.

  • Technical specification
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of solid-wall oriented unplasticized poly(vinyl chloride) (PVC-O) fittings for piping systems intended to be used underground or above ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. This document is applicable to double sockets, repair couplings, reducers and to non-end load bearing elbows only. This document is not applicable to tees, flange adaptors, etc. NOTE For double sockets, repair couplings, and reducers, there are no special fittings designs for end-load bearing applications. However, restrained gaskets can be used for end-load bearing applications. In this case, the requirements of ISO 16422-5 are applicable. This document also specifies the test parameters for the test methods referred to in this document. In conjunction with ISO 16422-1 and ISO 16422-5, this document is applicable to oriented PVC-O pipes with or without an integral socket, intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2, Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressure of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar =0,1 MPa=105 Pa; 1 MPa= 1 N/mm2

  • Technical specification
    19 pages
    English language
    sale 15% off

This document specifies the field of application, the dimensional, the physico-chemical, the design, the hydraulic, the mechanical, and the acoustic characteristics of controllable backflow preventers with reduced pressure zone Family B Type A.
This document covers controllable backflow preventers of Family B Type A, with reduced pressure zones, intended to prevent pollution of potable water by backflow, caused by backsiphonage or by backpressure.
It is applicable to controllable backflow preventers in denominations DN 6 up to DN 250.
It covers controllable backflow preventers of PN 10 that are capable of working without modification or adjustment:
-   at any pressure, up to 1 MPa (10 bar);
-   with any pressure variation, up to 1 MPa (10 bar);
-   in permanent duty at a limited temperature of 65 °C and for maximum 1 h at 90 °C.
It specifies also the test methods and requirements for verifying their characteristics, the marking and the presentation at delivery.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics and the requirements of air gap with non-circular overflow (unrestricted) Family A, Type B for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This document applies to air gaps in factory-assembled products and to constructed air gaps in situ and defines requirements and methods to verify and ensure compliance with this document during normal working use.
The fluid in the receiving vessel is assumed to have similar properties to the water supply. Where this is not the case, additional care or tests could be required to verify the efficacy of the solution in practical use.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies definitions, requirements and testing of additional functionalities for water meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in response to EU/EFTA Mandate M/441 EN. These AFDs are to be considered as “ancillary devices" as defined in EN 14154-1.
This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software.
NOTE    A manufacturer can claim compliance only for additional functionalities described in this standard. It is not mandatory that an AFD complies with all additional functionalities described herein.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies definitions, requirements and testing of additional functionalities for water meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in response to EU/EFTA Mandate M/441 EN. These AFDs are considered as “ancillary devices” as defined in EN ISO 4064-1:2017 and EN ISO 4064-4:2014.
This document does not cover the changing of metrological software within the meter or the upload/download of metrological software.
NOTE   A manufacturer can claim compliance only for additional functionalities described in this document. It is not mandatory that an AFD complies with all additional functionalities described herein.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Inspired on the International standards ISO 21053 part 1 LCC, the proposed EN standard will be enriched with additional sections:
‒ to define the Reference Service Life (RSL), Functional Units, safety criteria’s for water supply service,
parameters of in-used conditions.
‒ to clarify the conditions of validity of data’s (published, home data’s…)
‒ to introduce concept of Circular Economy and Recyclability of Ductile Iron pipelines.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the field of application, the dimensional, the physico-chemical, the design, the hydraulic, the mechanical, and the acoustic characteristics of controllable backflow preventers with reduced pressure zone, Family B, Type A.
This document covers controllable backflow preventers of Family B, Type A, with reduced pressure zones, intended to prevent pollution of potable water by backflow, caused by backsiphonage or by backpressure.
It is applicable to controllable backflow preventers in denominations DN 6 up to DN 250.
It covers controllable backflow preventers of PN 10 that are capable of working without modification or adjustment:
- at any pressure, up to 1 MPa (10 bar);
- with any pressure variation, up to 1 MPa (10 bar);
- in permanent duty at a limited temperature of 65 °C and for maximum 1 h at 90 °C.
It specifies also the test methods and requirements for verifying their characteristics, the marking and the presentation at delivery.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies dimensions, materials and performance requirements (including methods of test) for expansion valves, of nominal sizes from DN 15 to DN 32, having working pressures ) from 0,1 MPa (l bar) to 1,0 MPa (10 bar).
Expansion valves are intended for fitting to the cold potable water supply of storage water heaters, having a maximum distribution temperature of 95 °C, for all energy sources.
Expansion valves do not control the temperature and alone do not constitute the protection required for storage water heaters. Expansion valves limit pressure, in the water heaters to what they are fitted, that is produced by thermal expansion of the water.
NOTE   The use of the device specified in this document does not override the need to use controls (e.g. thermostats and cut-outs) which act directly on the power sources of water heaters (for more information see Annex A).

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation method of life cycle cost (LCC) and Life cycle assessment (LCA) of ductile iron pipes and fittings used for water applications and which are in compliance with EN 545.
LCC evaluation is based on concepts and methods developed in ISO 15686 5.
LCA evaluation is based on concepts and methods developed in ISO 15686 6, EN 15804:2012+A2:2019, EN ISO 14040 and EN ISO 14044.
In this document, LCA is limited to the evaluation of environmental impact due to CO2 emissions associated with the consumption of natural resources or energy and waste disposal. The other categories of impacts are not in the scope of this document.
Informative annexes are included in this document as a compilation of references, consensual factors, and scenarios with different DI pipelines.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for materials used for moulded seals made of thermoplastic elastomers (TPEs) for joints in: a) thermoplastic piping systems for non-pressure wastewater discharge (intermittent flow at up to 95 °C) inside buildings; b) thermoplastic piping systems for non-pressure underground drainage and sewerage (continuous flow at up to 45 °C and intermittent flow at up to 95 °C); c) thermoplastic rainwater piping systems. General requirements for finished joint seals are also given; any additional requirements for a particular application are specified in the relevant product standards taking into account that the performance of pipe joints is a function of the seal material properties, seal geometry and pipe joint design.

  • Standard
    11 pages
    English language
    sale 15% off

The standard specifies requirements for appliances for household and similar purposes to prevent the backflow of non-potable water into the water mains. It also specifies requirements for hose sets used for connecting such appliances to the water mains that supply water at a pressure not exceeding 1 MPa.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies dimensions, materials and performance requirements (including methods of test) for expansion valves, of nominal sizes from DN 15 to DN 32, having working pressures ) from 0,1 MPa (l bar) to 1,0 MPa (10 bar).
Expansion valves are intended for fitting to the cold potable water supply of storage water heaters, having a maximum distribution temperature of 95 °C, for all energy sources.
Expansion valves do not control the temperature and alone do not constitute the protection required for storage water heaters. Expansion valves limit pressure, in the water heaters to what they are fitted, that is produced by thermal expansion of the water.
NOTE   The use of the device specified in this document does not override the need to use controls (e.g. thermostats and cut-outs) which act directly on the power sources of water heaters (for more information see Annex A).

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-12-06: BTdecision D161/C047: project can proceed and be finalized (without link to legislation)

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The standard specifies requirements for appliances for household and similar purposes to prevent the backflow of non-potable water into the water mains. It also specifies requirements for hose sets used for connecting such appliances to the water mains that supply water at a pressure not exceeding 1 MPa.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides details about the aggressiveness factors, evaluation indicators of raw water, or inlet water of ductile iron pipe system and relevant lining information applicable to ductile iron pipes, fittings and accessories used in water mains and distribution system. This document is intended to serve as a tool for estimating the properties of certain water and their effect on internal linings of ductile iron pipes, fittings and accessories used in water mains and distribution system which are specified in ISO 2531, ISO 16631 and can be used to decide the most appropriate protective measures to ensure long term durability of pipeline. It is not always possible to definitively determine the aggressive parameters of certain water, and fully considered by limited test and evaluation. Therefore, the history information of the evaluated water, experiences of local water works can be taken for reference. The aggressiveness evaluation of water can be carried out before determining the internal lining materials of certain pipeline, and the evaluation and relevant tests can be done by qualified laboratories and engineers. Water that leads to high-level scaling in the pipeline is believed aggressive. Drainage and waste water are not in the scope of this document, the internal protection of drainage and waste water can be recommended by pipe suppliers.

  • Technical report
    19 pages
    English language
    sale 15% off

This document describes a method for the analysis, evaluation and management of risks that exist or may
arise from the use of potable water installations within buildings and, for certain purposes, outside
buildings but within the premises. Water Safety Plans for potable water supply systems are excluded
from the scope of this document.
The document is addressed to all organisations and other stakeholders which are responsible for
providing potable water within a safe potable water installation inside buildings according to EN 806,
EN 1717 and national regulations.

  • Technical report
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day