Hexagon flange head tapping screws

This International Standard specifies hexagon flange head tapping screws with threads from ST2,2 up to and
including ST9,5.

Vis à tôle à tête hexagonale à embase cylindro-tronconique

L'ISO 10509:2012 spécifie les vis à tôle à tête hexagonale à embase cylindro-tronconique, de diamètre nominal ST2,2 à ST9,5 inclus.

Pločevinski vijaki s šestrobo glavo s krajcem

Ta mednarodni standard določa pločevinske vijake s šestrobo glavo s krajcem z navojem od ST2,2 do vključno ST9,5.

General Information

Status
Published
Publication Date
07-May-2012
Current Stage
9093 - International Standard confirmed
Completion Date
01-Jul-2022

Relations

Buy Standard

Standard
ISO 10509:2012 - Hexagon flange head tapping screws
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 10509:2015
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 10509:2012 - Vis a tôle a tete hexagonale a embase cylindro-tronconique
French language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 10509
Second edition
2012-05-15
Hexagon flange head tapping screws
Vis à tôle à tête hexagonale à embase cylindro-tronconique
Reference number
ISO 10509:2012(E)
©
ISO 2012

---------------------- Page: 1 ----------------------
ISO 10509:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 10509:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10509 was prepared by Technical Committee ISO/TC 2, Fasteners, Subcommittee SC 13, Fasteners with
non-metric thread.
This second edition cancels and replaces the first edition (ISO 10509:1992), which has been technically revised.
In particular, Clauses 2 and 5, Tables 1 and 2, as well as Figures 1 and A.1 have been technically revised.
© ISO 2012 – All rights reserved iii

---------------------- Page: 3 ----------------------
INTERNATIONAL STANDARD ISO 10509:2012(E)
Hexagon flange head tapping screws
1 Scope
This International Standard specifies hexagon flange head tapping screws with threads from ST2,2 up to and
including ST9,5.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 225, Fasteners — Bolts, screws, studs and nuts — Symbols and descriptions of dimensions
ISO 1478, Tapping screws thread
ISO 2702, Heat-treated steel tapping screws — Mechanical properties
ISO 3269, Fasteners — Acceptance inspection
ISO 3506-4, Mechanical properties of corrosion-resistant stainless steel fasteners — Part 4: Tapping screws
ISO 4042, Fasteners — Electroplated coatings
ISO 4759-1, Tolerances for fasteners — Part 1: Bolts, screws, studs and nuts — Product grades A, B and C
ISO 8992, Fasteners — General requirements for bolts, screws, studs and nuts
ISO 10683, Fasteners — Non-electrolytically applied zinc flake coatings
ISO 16048, Passivation of corrosion-resistant stainless-steel fasteners
3 Dimensions
For the dimensions, see Figure 1 and Table 1.
Symbols and descriptions of dimensions are specified in ISO 225.
© ISO 2012 – All rights reserved 1

---------------------- Page: 4 ----------------------
ISO 10509:2012(E)
a)  Type C
b)  Type F
c)  Type R
Key
1 chamfer or radius
a
Optional indentation.
b
Dimension a is to be measured at the core diameter of the first full thread.
Figure 1 — Hexagon flange head tapping screw
2 © ISO 2012 – All rights reserved

---------------------- Page: 5 ----------------------
ISO 10509:2012(E)
Table 1 — Dimensions
Dimensio
...

SLOVENSKI STANDARD
SIST ISO 10509:2015
01-marec-2015
1DGRPHãþD
SIST ISO 10509:1996
3ORþHYLQVNLYLMDNLVãHVWURERJODYRVNUDMFHP
Hexagon flange head tapping screws
Vis à tôle à tête hexagonale à embase cylindro-tronconique
Ta slovenski standard je istoveten z: ISO 10509:2012
ICS:
21.060.10 Sorniki, vijaki, stebelni vijaki Bolts, screws, studs
SIST ISO 10509:2015 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 10509:2015

---------------------- Page: 2 ----------------------

SIST ISO 10509:2015
INTERNATIONAL ISO
STANDARD 10509
Second edition
2012-05-15
Hexagon flange head tapping screws
Vis à tôle à tête hexagonale à embase cylindro-tronconique
Reference number
ISO 10509:2012(E)
©
ISO 2012

---------------------- Page: 3 ----------------------

SIST ISO 10509:2015
ISO 10509:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

---------------------- Page: 4 ----------------------

SIST ISO 10509:2015
ISO 10509:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10509 was prepared by Technical Committee ISO/TC 2, Fasteners, Subcommittee SC 13, Fasteners with
non-metric thread.
This second edition cancels and replaces the first edition (ISO 10509:1992), which has been technically revised.
In particular, Clauses 2 and 5, Tables 1 and 2, as well as Figures 1 and A.1 have been technically revised.
© ISO 2012 – All rights reserved iii

---------------------- Page: 5 ----------------------

SIST ISO 10509:2015

---------------------- Page: 6 ----------------------

SIST ISO 10509:2015
INTERNATIONAL STANDARD ISO 10509:2012(E)
Hexagon flange head tapping screws
1 Scope
This International Standard specifies hexagon flange head tapping screws with threads from ST2,2 up to and
including ST9,5.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 225, Fasteners — Bolts, screws, studs and nuts — Symbols and descriptions of dimensions
ISO 1478, Tapping screws thread
ISO 2702, Heat-treated steel tapping screws — Mechanical properties
ISO 3269, Fasteners — Acceptance inspection
ISO 3506-4, Mechanical properties of corrosion-resistant stainless steel fasteners — Part 4: Tapping screws
ISO 4042, Fasteners — Electroplated coatings
ISO 4759-1, Tolerances for fasteners — Part 1: Bolts, screws, studs and nuts — Product grades A, B and C
ISO 8992, Fasteners — General requirements for bolts, screws, studs and nuts
ISO 10683, Fasteners — Non-electrolytically applied zinc flake coatings
ISO 16048, Passivation of corrosion-resistant stainless-steel fasteners
3 Dimensions
For the dimensions, see Figure 1 and Table 1.
Symbols and descriptions of dimensions are specified in ISO 225.
© ISO 2012 – All rights reserved 1

---------------
...

NORME ISO
INTERNATIONALE 10509
Deuxième édition
2012-05-15
Vis à tôle à tête hexagonale à embase
cylindro-tronconique
Hexagon flange head tapping screws
Numéro de référence
ISO 10509:2012(F)
©
ISO 2012

---------------------- Page: 1 ----------------------
ISO 10509:2012(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2012
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord écrit
de l’ISO à l’adresse ci-après ou du comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2012 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 10509:2012(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de
normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales,
en liaison avec l’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l’approbation de 75 % au moins des comités membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de droits
de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de ne pas avoir
identifié de tels droits de propriété et averti de leur existence.
L’ISO 10509 a été élaborée par le comité technique ISO/TC 2, Éléments de fixation, sous-comité SC 13,
Éléments de fixation à filetage non métrique.
Cette deuxième édition annule et remplace la première édition (ISO 10509:1992), qui a fait l’objet d’une révision
technique. En particulier, les Articles 2 et 5, les Tableaux 1 et 2, ainsi que les Figures 1 et A.1 ont fait l’objet
d’une révision technique.
© ISO 2012 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
NORME INTERNATIONALE ISO 10509:2012(F)
Vis à tôle à tête hexagonale à embase cylindro-tronconique
1 Domaine d’application
La présente Norme internationale spécifie les vis à tôle à tête hexagonale à embase cylindro-tronconique, de
diamètre nominal ST2,2 à ST9,5 inclus.
2 Références normatives
Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les
références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du
document de référence s’applique (y compris les éventuels amendements).
ISO 225, Éléments de fixation — Vis, goujons et écrous — Symboles et description des dimensions
ISO 1478, Filetage de vis à tôle
ISO 2702, Vis à tôle en acier traité thermiquement — Caractéristiques mécaniques
ISO 3269, Éléments de fixation — Contrôle de réception
ISO 3506-4, Caractéristiques mécaniques des éléments de fixation en acier inoxydable résistant à la
corrosion — Partie 4 : Vis à tôle
ISO 4042, Éléments de fixation — Revêtements électrolytiques
ISO 4759-1, Tolérances des éléments de fixation — Partie 1: Vis, goujons et écrous — Grades A, B et C
ISO 8992, Éléments de fixation — Exigences générales pour vis, goujons et écrous
ISO 10683, Éléments de fixation — Revêtements non électrolytiques de zinc lamellaire
ISO 16048, Passivation des éléments de fixation en acier inoxydable résistant à la corrosion
3 Dimensions
Voir Figure 1 et Tableau 1.
Les symboles et la description des dimensions sont spécifiés dans l’ISO 225.
© ISO 2012 – Tous droits réservés 1

---------------------- Page: 4 ----------------------
ISO 10509:2012(F)
a)  Type C
b)  Type F
c)  Type R
Légende
1 chanfrein ou rayon
a
Cuvette facultative.
b
La dimension a doit être mesurée sur le diamètre de tige, au niveau du premier filet complet.
Figure 1 — Vis à tôle à tête hexagonale cylindro-tronconique
2 © ISO 2012 – Tous droits réservés

---------------------- Page: 5 -----------------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.