Nanotechnologies — Method to quantify air concentrations of carbon black and amorphous silica in the nanoparticle size range in a mixed dust manufacturing environment

This document provides guidelines to quantify and identify air concentration (number of particles/cm3) of particles of carbon black and/or amorphous silica by size in air samples collected in a mixed dust industrial manufacturing environment. The method is defined for air samples collected with an electrical low pressure cascade impactor (ELPCI). on a 25 mm polycarbonate substrate. The method is suitable for sampling in manufacturing environments where there are a variety of particle types contributing to the overall atmosphere. This method is applicable only to environments with chemically and physically distinct particles contributing to aerosols or when confounders can be controlled (e.g. diesel sources). Other sampling methods can also be suitable, though this document is limited to describing methods associated with the electrical low pressure cascade impactor. Samples collected with the electrical low pressure cascade impactor are analyzed via TEM and EDS to for particle morphology and elemental composition, respectively, to permit identification of particles by type. This information is then used, in conjunction with particle concentration by size range, as determined by the electrical low pressure cascade impactor, to determine concentration of the materials of interest by size.

Nanotechnologies — Méthode de quantification des concentrations dans l'air de noir de carbone et de silice amorphe à l'échelle nanométrique dans un environnement de fabrication industrielle contenant des mélanges de poussières

Le présent document fournit des lignes directrices pour quantifier et identifier la concentration (nombre de particules/cm3) de particules de noir de carbone et/ou de silice amorphe par taille, dans les échantillons d'air prélevés dans un environnement de fabrication industrielle contenant des mélanges de poussières. La méthode est définie pour les échantillons d'air prélevés en utilisant un impacteur en cascade à basse pression à détection électrique (ELPCI) sur un substrat de polycarbonate de 25 mm. La méthode décrite convient pour effectuer des prélèvements dans des environnements de fabrication où l'atmosphère générale contient une grande diversité de types de particules. Cette méthode n'est applicable qu'aux environnements dont les particules contribuant aux aérosols sont chimiquement et physiquement distinctes, ou lorsque les matériaux parasites peuvent être contrôlés (particules provenant de moteurs diesel, par exemple). Bien que le présent document se limite à la description de méthodes associées à l'impacteur en cascade à basse pression à détection électrique, d'autres méthodes de prélèvement pourraient également convenir. Les échantillons recueillis avec l'impacteur en cascade à basse pression à détection électrique sont analysés par MET et EDS afin de déterminer, respectivement, la morphologie des particules et la composition élémentaire, pour pouvoir identifier les particules par type. Ces informations sont ensuite utilisées, conjointement avec la concentration de particules par plage granulométrique, déterminée à l'aide de l'impacteur en cascade à basse pression à détection électrique, afin de déterminer la concentration des matériaux étudiés en fonction de leur taille.

General Information

Status
Published
Publication Date
22-Apr-2019
Current Stage
9092 - International Standard to be revised
Completion Date
21-Nov-2022
Ref Project

Buy Standard

Technical specification
ISO/TS 21361:2019 - Nanotechnologies -- Method to quantify air concentrations of carbon black and amorphous silica in the nanoparticle size range in a mixed dust manufacturing environment
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
ISO/TS 21361:2019 - Nanotechnologies -- Méthode de quantification des concentrations dans l'air de noir de carbone et de silice amorphe a l'échelle nanométrique dans un environnement de fabrication industrielle contenant des mélanges de poussieres
French language
14 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

TECHNICAL ISO/TS
SPECIFICATION 21361
First edition
2019-04
Nanotechnologies — Method to
quantify air concentrations of carbon
black and amorphous silica in the
nanoparticle size range in a mixed
dust manufacturing environment
Nanotechnologies — Quantification du noir de carbonne et de la silice
amorphe nanométriques en suspension dans l'air en ambiance de
production
Reference number
ISO/TS 21361:2019(E)
©
ISO 2019

---------------------- Page: 1 ----------------------
ISO/TS 21361:2019(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

---------------------- Page: 2 ----------------------
ISO/TS 21361:2019(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Abbreviations. 3
6 Reagents . 3
7 Apparatus . 4
7.1 Air sampling — Equipment and consumable supplies . 4
7.1.1 Electrical low cascade pressure impactor (ELPCI) . 4
7.1.2 Limit of Detection . 4
7.1.3 Real-time aerosol monitor . 5
7.1.4 Vacuum pump . 5
7.1.5 Polycarbonate substrate . 5
7.1.6 Hydrocarbon grease . 5
7.2 Analytical/microscopy laboratories . 6
7.3 Sample analysis — Equipment and consumables . 6
7.3.1 Transmission electron microscope (TEM) . 6
7.3.2 Energy dispersive spectrometry (EDS) . 6
7.3.3 Computer . 6
7.3.4 TEM Grid . 6
8 Air sample collection . 6
8.1 Preparation for sampling . 6
8.2 Determination of sampling time . 7
8.3 Sample collection procedure . 7
9 Procedure for analysis . 7
9.1 General . 7
9.2 Preparation of substrates . 8
9.3 Sample analysis . 8
9.3.1 Instrument conditions . 8
9.3.2 Data collection . 8
9.4 Calculation of air concentration . 9
10 Uncertainties and performance criteria .10
10.1 Particle counting with the ELPCI.10
10.2 Particle analysis with TEM/EDS .11
11 Test report .11
Annex A (informative) Case study overview .12
Bibliography .13
© ISO 2019 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO/TS 21361:2019(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see www .iso
.org/iso/foreword .html.
This document was prepared by Technical Committee ISO/TC 229, Nanotechnologies.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2019 – All rights reserved

---------------------- Page: 4 ----------------------
ISO/TS 21361:2019(E)

Introduction
Nanomaterials are widely used in industrial settings in the manufacture of consumer products. Carbon
black and/or amorphous silica are commonly used in consumer products, such as rubber products,
insulating materials, and others. Although these materials typically exist as agglomerates in dimensions
larger than the nanoscale, there is also potential for worker exposure to these materials in the
nanoscale size range. In spite of the widespread use of nanomaterials such as these, quantification of air
concentrations of specific nanomaterials in mixed dust settings, such as a manufacturing environment,
have been challenging to date and has been identified as a hindrance to the development of nano-
specific occupational exposure limits (Gordon, et al. 2014; Hansen, et al. 2012; van Broekhuizen, et al.
2013). This method outlines a technique whereby particles carbon black and amorphous silica can be
identified, distinguished, and quantified (in terms of air concentrations) by size in such manufacturing
settings. It is anticipated that although this method is specific to carbon black and amorphous silica,
the general principles of the method can be applied to many materials in a variety of manufacturing
environments. This method advances beyond existing techniques for analysis in that it provides
quantitative information regarding exposure to specific materials by size; many other methods provide
quantitative information on nanoparticle exposures that are incapable of differentiating by material
type. This method includes both a defined methodology for collecting air samples in the manufacturing
settings as well as a methodology for analyzing the sample to obtain appropriate information for
quantifying air concentration of the materials of interest. Application of this methodology has recently
been published in the peer-reviewed literature (Kreider, et al. 2015).
This document will provide guidelines to quantify and identify particles carbon black and/or
amorphous silica in air samples collected in a mixed dust industrial manufacturing environment. The
guidelines describe air sample collection and the characterization of the particles in the air samples
by both particle size and elemental composition. The particles in the air sample are collected in the
various stages of a cascade impactor with cut-offs for median particle size between 6 nm and 10 µm.
This impactor determines the number particle size distribution in real-time based on the particle
aerodynamic diameter. Particles collected on each stage are collected for off-line analysis using
Transmission Electron Microscopy (TEM) and Energy Dispersive Spectrometry (EDS) to identify
amorphous silica and carbon black particles. The TEM-EDS measurement provides the elemental
composition and source of the particles in each stage. Scanning Electron Microscopy (SEM) is also an
option to TEM in the electron microscopy/dispersive spectrometry combination. The concentration of
3
particles of a specific nanomaterial in a given size range (#/cm ) is given by the product of the total
3
particle count for size range (#/cm ) obtained from the cascade impactor and the fraction of particles
identified as the specific material of interest (e.g. carbon black or amorphous silica) from the TEM-EDS
results. Though this technique is described for carbon black and amorphous silica, the technique can
be applied to the measurement of other particle types, provided they are in the size range of 6 nm to
2,5 µm and can be observed by TEM/SEM and chemically characterized by EDS.
At this time, this methodology represents the one of the methods available to quantify chemical-
specific exposures to nanoparticles by size with this degree of sensitivity. Many of the other existing
methods that can speciate and quantify chemical exposure in this size range are mass-based, and thus
are limited by mass-based detection limits that are high when compared to the mass of particles in
this size range. Furthermore, although other sampling methods may be amenable to the techniques
described herein, none have been evaluated or validated for this purpose. Therefore, this methodology
offers increased sensitivity for quantification of exposure to specific particle types in the nanoscale
when such an interest arises. This methodology could be implemented as a higher tier step in an
occupational exposure assessment sampling strategy for nanomaterials, particularly in the event hot
spots for exposure are identified using other methods and there is an interest in understanding the
nature of the exposure. Results from this analysis can be used to compare to health benchmarks, as
they become available, to understand potential health risk of workers. In addition, it could be useful in
selecting appropriate personal protective equipment (PPE) at a very early stage of the manufacturing
process, when required.
© ISO 2019 – All rights reserved v

---------------------- Page: 5 ----------------------
TECHNICAL SPECIFICATION ISO/TS 21361:2019(E)
Nanotechnologies — Method to quantify air concentrations
of carbon black and amorphous silica in the nanoparticle
size range in a mixed dust manufacturing environment
1 Scope
This document provides guidelines to quantify and identify air concentration (number of particles/
3
cm ) of particles of carbon black and/or amorphous silica by size in air samples collected in a mixed
dust industrial manufacturing environment.
The method is defined for air samples collected with an electrical low pressure cascade impactor
(ELPCI). on a 25 mm polycarbonate substrate. The method is suitable for sampling in manufacturing
environments where there are a variety of particle types contributing to the overall atmosphere.
This method is applicable only to environments with chemically and physically distinct particles
contributing to aerosols or when confounders can be controlled (e.g. diesel sources). Other sampling
methods can also be suitable, though this document is limited to describing methods associated with
the electrical low pressure cascade impactor.
Samples collected with the electrical low pressure cascade impactor are analyzed via TEM and EDS to
for particle morphology and elemental composition, respectively, to permit identification of particles
by type. This information is then used, in conjunction with particle concentration by size range,
as determined by the electrical low pressure cascade impactor, to determine concentration of the
materials of interest by size.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 10312, Ambient Air — Determination of asbestos fibres — Direct‐transfer transmission electron
microscopy method
ISO 4225, Air quality — General aspects — Vocabulary
ISO/TS 80004-1, Nanotechnologies — Vocabulary — Part 1: Core terms
ISO 22309, Microbeam analysis — Quantitative analysis using energy‐dispersive spectrometry (EDS) for
elements with an atomic number of 11 (Na) or above
ISO/TS 10798, Nanotechnologies — Charaterization of single‐wall carbon nanotubes using scanning
electron microscopy and energy dispersive X‐ray spectrometry analysis
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4225 and ISO/TS 80004-1 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
© ISO 2019 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO/TS 21361:2019(E)

3.1
particle aerodynamic diameter
−3
diameter of a sphere of density 1,000 kg m that has the same settling velocity as the irregular particle
3.2
cascade impactor
device for simultaneously collecting particles separately in a number of size ranges by impaction,
depending on the momentum
3.3
cut‐off
size of particles at which the retention efficiency of an instrument device drops below a specified value
under defined conditions
3.4
nanoscale
size range from approximately 1 nm to 100 nm
3.5
nanomaterial
material with any external dimension in the nanoscale or having internal structure or surface structure
in the nanoscale
3.6
particle
minute piece of matter with defined physical boundaries
3.7
sampling time
interval of time over which a single sample is taken
4 Principle
Air sampling is conducted using an electrical low pressure cascade impactor (ELPCI). The ELPCI is
a cascade impactor with multiple stages representing different size bins, distinguished based on
aerodynamic diameter. The cascade impactor is connected to a vacuum pump, which pulls air (and
subsequently airborne particles) into the impactor. As particles enter the cascade impactor, they are
charged and then subsequently separated by aerodynamic size onto different stages. As the particles
come into contact with the surface of their appropriate stage, they transmit an electrical current to the
ELPCI. This electrical current is then converted into a particle count for that stage, thus permitting the
ELPCI to conduct real-time particle counting. This particle count is reported as number of particles per
3
cm of air. In addition to the particle counting function, the ELPCI also allows for collection of samples
on each stage, using a 25 mm polycarbonate substrate.
Following completion of air sampling, these substrates are analyzed via TEM to identify the particles
on each stage by morphology coupled with EDS to identify the particles on each stage by elemental
composition. A minimum of 100 distinct particles per stage are analyzed using TEM- EDS to identify
the particle type, based on the chemical signature of the particles. Carbon black, made up primarily
of elemental carbon, elicits a strong carbon signal (and absence of other signals) on the EDS, whereas
silica (SiO ) elicits a strong silicon and oxygen signal. These profiles are used to designate particles
2
as carbon black or amorphous silica. Where there are potential confounders present in the sample,
such as soot (for carbon black) or crystalline silica (for amorphous silica), particle morphology and/or
diffraction pattern must be relied upon to identify the particles. Morphology is the main attribute that
distinguishes carbon black from soot, whereas morphology and diffraction can be used to distinguish
crystalline silica from amorphous. Furthermore, comparison to the morphology of the source materials
(e.g. carbon black or amorphous silica) can be evaluated under TEM to ensure appropriate assignation
of the particle type. The relative proportion of particles (e.g. number of particles by type out of 100
total particles identified per size fraction) identified by type of particle (carbon black, amorphous silica,
or other) is the key outcome of this analysis.
2 © ISO 2019 – All rights reserved

---------------------- Page: 7 ----------------------
ISO/TS 21361:2019(E)

To determine air concentration of the materials of interest (e.g. carbon black or amorphous silica), the
proportion of particles identified by type is multiplied by the total number of particles in each size bin
determined during the real-time air sampling. The outcome of this analysis is the air concentration of
3
each material type by size in number of particles/cm .
Though the method described herein will specifically focus on the analysis of carbon black and
amorphous silica, this methodology is transferrable to other materials, provided they have a unique
signal under EDS and/or are distinguishable via morphology under TEM.
5 Abbreviations
EDS energy dispersive spectroscopy
ELPCI electrical low pressure cascade impactor
HEPA high efficiency particulate arrestance
LOD limit of detection
PM10 airborne particles with an aerodynamic diameter less than 10 μm
SEM scanning electron microscopy
TEM transmission electron microscopy
6 Reagents
During the analysis, use only reagents of recognized analytical grade. All agents listed are required
to execute the transfer of the polycarbonate substrate content onto a TEM grid in accordance with
ISO 10312. No additional reagents are required for execution of this specification.
WARNING — Use the reagents in accordance with the appropriate health and safety regulations.
6.1 Water, fibre‐free.
A supply of freshly distilled, fibre-free water, or another source of fibre-free, pyrogen-free water shall
be used.
6.2 Chloroform, analytical grade.
Distilled in glass, preserved with 1 % (WV) ethanol; used to dissolve polycarbonate substrate.
6.3 l‐Methyl‐2‐pyrrolidone.
Used to dissolve polycarbonate substrate.
6.4 Dimethylformamide.
Used to dissolve polycarbonate substrate.
6.5 Glacial acetic acid.
Used to dissolve polycarbonate substrate.
6.6 Acetone.
Used to dissolve polycarbonate substrate.
© ISO 2019 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO/TS 21361:2019(E)

7 Apparatus
7.1 Air sampling — Equipment and consumable supplies
7.1.1 Electrical low cascade pressure impactor (ELPCI)
An electrical low pressure cascade impactor, consisting of a minimum of 14 size bins, should be used for
collection of air samples. Of the size bins, at least 3 should be within the nanoscale, defined as less than
100 nm. The ELPCI should be operated in accordance with the manufacturer’s instructions.
An example of measurement capability for a commercially available electrical low pressure impactor
operating at a 10 l/min flow rate is presented in the Table 1.
Table 1 — Measurement range for commercially available electrical low pressure cascade
impactor (Dekati, 2011)
D50 % Di Number min Number max Mass conc. min Mass conc. max
3 3 3 3
nm nm 1/cm 1/cm µg/m µg/m
10 000 Unavailable Unavailable Unavailable Unavailable Unavailable
6 800 8 200 0,1 2,40E+04 30 10 000
4 400 5 500 0,1 2,40E+04 10 3 000
2 500 3 300 0,15 5,40E+04 3 1 000
1 600 2 000 0,3 1,10E+05 1,4 450
1 000 1 300 0,5 1,90E+05 0,7 210
640 800 1 3,50E+05 0,3 100
400 510 2 6,40E+05 0,1 50
260 320 3 1,20E+06 0,07 20
170 210 5 2,10E+06 0,03 10
108 140 10 3,70E+06 0,02 5
60 80 20 7,30E+06 0,005 2
30 42 50 1,70E+07 0,002 0,5
17 22 100 3,40E+07 0,001 0,25
6 1 250 8,30+07 0,000 4 0,13
D50 % = Aerodynamic diameter cut-offs for 50 % efficiency; Di = Geometric mean aerodynamic diameter of stage
7.1.2 Limit of Detection
Based on the table above and the expected volumetric flow rate of the sampling equipment (10 l/min),
the practical limits of detection (LOD) for both carbon black and amorphous silica (based on a one-
second sample) by particle size are found in Table 2.
Table 2 — Limits of detection by particle size (Dekati, 2011)
D50 % Di LOD
nm nm in # of particles
10 000 Not applicable
6 800 8 200 16,6
4 400 5 500 16,6
2 500 3 300 24,9
D50 % = Aerodynamic diameter cut-offs for 50 % efficiency;
D = Geometric mean aerodynamic diameter of stage;
i
LOD = Limit of detection.
4 © ISO 2019 – All rights reserved

---------------------- Page: 9 ----------------------
ISO/TS 21361:2019(E)

Table 2 (continued)
D50 % Di LOD
nm nm in # of particles
1 600 2 000 49,8
1 000 1 300 83
640 800 166
400 510 332
260 320 498
170 210 830
108 140 1 660
60 80 3 320
30 42 8 300
17 22 16 600
6 1 41 500
D50 % = Aerodynamic diameter cut-offs for 50 % efficiency;
D = Geometric mean aerodynamic diameter of stage;
i
LOD = Limit of detection.
Detection limits presented in this table are approximate based on a typical impactor; each impactor
has exact specifications that may result in deviations from the reported detection limits. The detection
limit for a specific duration can be calculated by converting the minimum concentration of particles
detectable to number of particles based on sample duration and volumetric flow rate of the impactor.
Increasing the duration of sampling will decrease the detection limit based on increased volume of
collection.
7.1.3 Real‐time aerosol monitor
A real-time aerosol monitor, capable of measuring mass of particulate consistent with the size range of
the ELPCI (e.g. PM10 if largest size bin of ELPCI is 10 μm), should be operating coincident with the ELPCI
sampling. Output of the real-time aerosol monitor will be used to appropriately designate sample time
of the ELPCI to prevent under/overloading of the substrate (see 8.2 and Table 3). The real-time aerosol
monitor should be operated in accordance with the manufacturer’s instructions.
7.1.4 Vacuum pump
A vacuum pump, calibrated to a flow rate consistent with what is required for appropriate size
fractionation in the ELPCI (i.e. 10 l/min), will be required to introduce air and particles into the cascade
impactor. The vacuum pump should be operated in accordance with the manufacturer’s instructions.
7.1.5 Polycarbonate substrate
A 25-mm polycarbonate substrate. The substrate should be compatible with the stages of the ELPCI.
Polycarbonate substrates should be handled using tweezers or similar to prevent transfer of oils from
the skin. This polycarbonate substrate is mounted in the ELPCI for sample collection.
Other collection media, such as polycarbonate filters, mixed cellulose ester filters, or others, could be
considered only if and when proper steps are taken to ensure size fractionation is unaffected by the
selected media.
7.1.6 Hydrocarbon grease
A silicone- and halogen-free vacuum grease is recommended for use on the surface of the selected
stages to prevent particle bounce within the cascade impactor. Select stages will be treated with this
grease at the time of sampling.
© ISO 2019 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO/TS 21361:2019(E)

7.2 Analytical/microscopy laboratories
The laboratories used for sample analysis, including sample preparation immediately prior to microscopy
analysis, shall be sufficiently free of contamination such that blank substrate analyses demonstrate an
absence of carbon black or amorphous silica as established by the method detection limit.
7.3 Sample analysis — Equipment and consumables
7.3.1 Transmission electron microscope (TEM)
A transmission electron microscope (TEM) is the preferred microscope for analysis of these samples,
though scanning electron microscopes (SEM) or scanning-transmission electron microscopes (STEM)
are also acceptable. The selected microscope must be capable of being coupled with an EDS. The TEM is
used for morphological identification of t
...

SPÉCIFICATION ISO/TS
TECHNIQUE 21361
Première édition
2019-04
Nanotechnologies — Méthode de
quantification des concentrations
dans l'air de noir de carbone
et de silice amorphe à l'échelle
nanométrique dans un environnement
de fabrication industrielle contenant
des mélanges de poussières
Nanotechnologies — Method to quantify air concentrations of carbon
black and amorphous silica in the nanoparticle size range in a mixed
dust manufacturing environment
Numéro de référence
ISO/TS 21361:2019(F)
©
ISO 2019

---------------------- Page: 1 ----------------------
ISO/TS 21361:2019(F)

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO/TS 21361:2019(F)

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Principe . 2
5 Abréviations . 3
6 Réactifs . 3
7 Appareillage . 4
7.1 Prélèvement d’air — Équipement et consommables . 4
7.1.1 Impacteur en cascade à basse pression à détection électrique (ELPCI) . 4
7.1.2 Limite de détection . 5
7.1.3 Moniteur d’aérosols en temps réel . 6
7.1.4 Pompe à vide . 6
7.1.5 Substrat de polycarbonate . 6
7.1.6 Graisse d’hydrocarbure . 6
7.2 Laboratoires d’analyse/de microscopie . 6
7.3 Analyse des échantillons — Équipement et consommables . 6
7.3.1 Microscope électronique à transmission (MET) . 6
7.3.2 Spectromètre à sélection d’énergie (EDS) . 6
7.3.3 Ordinateur . 7
7.3.4 Grille de MET . 7
8 Prélèvement des échantillons d’air . 7
8.1 Préparation au prélèvement . 7
8.2 Détermination de la durée d’échantillonnage. 7
8.3 Mode opératoire de prélèvement des échantillons . 8
9 Mode opératoire d’analyse . 8
9.1 Généralités . 8
9.2 Préparation des substrats . 8
9.3 Analyse des échantillons . 9
9.3.1 Conditions de mesure de l’instrument. 9
9.3.2 Collecte des données . 9
9.4 Calcul de la concentration dans l’air .10
10 Incertitudes et critères de performance .11
10.1 Comptage des particules avec l’ELPCI .11
10.2 Analyse des particules par MET/EDS .12
11 Rapport d’essai .12
Annexe A (informative) Présentation d’une étude de cas .13
Bibliographie .14
© ISO 2019 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO/TS 21361:2019(F)

Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos . ht m l .
Le présent document a été élaboré par le comité technique ISO/TC 229, Nanotechnologies.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
iv © ISO 2019 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO/TS 21361:2019(F)

Introduction
Les nanomatériaux sont largement utilisés pour la fabrication des produits de consommation en milieu
industriel. Le noir de carbone et/ou la silice amorphe sont couramment employés dans les produits
de consommation tels que les produits du caoutchouc, les matériaux isolants et autres. Bien que ces
matériaux existent généralement sous forme d’agglomérats de dimensions supérieures à l’échelle
nanométrique, il existe également un risque d’exposition des travailleurs à ces matériaux dans la
plage granulométrique à l’échelle nanométrique. Malgré l’usage répandu des nanomatériaux tels que
ceux précités, la quantification des concentrations dans l’air de nanomatériaux spécifiques dans les
milieux contenant des mélanges de poussières, tels que les environnements de fabrication, s’est avérée
problématique jusqu’à aujourd’hui et a été identifiée comme une entrave à la définition de limites
d’exposition professionnelle spécifiques aux nanomatériaux (Gordon et al. 2014; Hansen et al. 2012;
van Broekhuizen et al. 2013). La présente méthode exploite une technique qui permet d’identifier, de
distinguer et de quantifier (en termes de concentrations dans l’air) les particules de noir de carbone et
de silice amorphe, en fonction de leur taille, dans de tels milieux de fabrication. Bien que cette méthode
soit spécifique au noir de carbone et à la silice amorphe, ses principes généraux peuvent théoriquement
s’appliquer à de nombreux matériaux dans une diversité d’environnements de fabrication. Cette
méthode va au-delà des techniques d’analyse existantes car elle fournit des informations quantitatives
sur l’exposition à des matériaux spécifiques en fonction de leur taille; bon nombre d’autres méthodes
génèrent des informations quantitatives sur les expositions aux nanoparticules mais ne sont pas
capables de les différentier par type de matériau. Cette méthode comprend à la fois une méthodologie
définie pour prélever des échantillons d’air dans les milieux de fabrication, ainsi qu’une méthodologie
d’analyse des échantillons permettant d’obtenir des informations appropriées pour quantifier la
concentration dans l’air des matériaux étudiés. L’application de cette méthodologie a récemment fait
l’objet d’une publication dans la littérature spécialisée (Kreider et al., 2015).
Le présent document fournira des lignes directrices pour quantifier et identifier les particules de
noir de carbone et/ou de silice amorphe, dans les échantillons d’air prélevés dans un environnement
de fabrication industrielle contenant des mélanges de poussières. Ces lignes directrices décrivent
le prélèvement des échantillons d’air et la caractérisation des particules dans ces échantillons, en
fonction à la fois de la taille des particules et de la composition élémentaire. Les particules présentes
dans l’échantillon d’air sont collectées dans les différents étages d’un impacteur en cascade avec des
diamètres de coupure pour la taille de particule médiane entre 6 nm et 10 µm. L’impacteur détermine,
en temps réel, la distribution granulométrique en nombre sur la base du diamètre aérodynamique des
particules. Les particules recueillies à chaque étage sont collectées en vue d’une analyse hors ligne,
par microscopie électronique à transmission (MET) et spectrométrie à sélection d’énergie (EDS), afin
d’identifier les particules de silice amorphe et de noir de carbone. Le mesurage par MET‐EDS détermine
la composition élémentaire et la source des particules à chaque étage. La microscopie électronique
à balayage (MEB) constitue également une alternative à la MET dans la combinaison microscopie
électronique/spectrométrie à dispersion. La concentration de particules d’un nanomatériau spécifique
3
sur une plage granulométrique donnée (nombre de particules/cm ) est obtenue en multipliant le
3
nombre total de particules dans la plage concernée (nombre de particules/cm ) déterminé à partir
de l’impacteur en cascade, par la fraction de particules identifiées comme étant le matériau étudié
spécifique (noir de carbone ou silice amorphe, par exemple) à partir des résultats de l’analyse par MET‐
EDS. Bien que cette technique soit décrite pour le noir de carbone et la silice amorphe, elle peut être
appliquée au mesurage d’autres types de particule, sous réserve que ces particules soient dans la plage
granulométrique de 6 nm à 2,5 µm, qu’il soit possible de les observer par MET/SEM et de les caractériser
chimiquement par EDS.
À ce stade, cette méthodologie représente l’une des méthodes disponibles pour quantifier les
expositions chimiques aux nanoparticules, en fonction de leur taille, avec ce degré de sensibilité. Un
grand nombre des autres méthodes existantes qui peuvent différencier et quantifier l’exposition
chimique dans cette plage granulométrique reposent sur la masse et sont donc soumises à des limites
de détection fondées sur la masse, qui sont élevées par rapport à la masse des particules dans cette
plage. Par ailleurs, bien que les autres méthodes d’échantillonnage puissent être souples par rapport
aux techniques décrites dans le présent document, aucune n’a été évaluée ou validée à cet effet. Par
conséquent, cette méthodologie accroît la sensibilité de la quantification de l’exposition à des types
de particules spécifiques à l’échelle nanométrique lorsque cette quantification présente un intérêt.
© ISO 2019 – Tous droits réservés v

---------------------- Page: 5 ----------------------
ISO/TS 21361:2019(F)

Cette méthodologie pourrait être mise en œuvre sous la forme d’une étape de niveau supérieur dans
la stratégie d’échantillonnage pour l’évaluation de l’exposition professionnelle aux nanomatériaux, en
particulier en cas d’identification, par d’autres méthodes, de zones sensibles en termes d’exposition et
lorsque la compréhension de la nature de l’exposition présente un intérêt. Les résultats de cette analyse
peuvent être utilisés pour comparer les références en matière de santé, dès qu’elles sont disponibles,
afin de comprendre le risque potentiel pour la santé des travailleurs. De plus, il pourrait s’avérer utile
de choisir des équipements de protection individuelle (EPI) appropriés à un stade précoce du processus
de fabrication, lorsque cela est requis.
vi © ISO 2019 – Tous droits réservés

---------------------- Page: 6 ----------------------
SPÉCIFICATION TECHNIQUE ISO/TS 21361:2019(F)
Nanotechnologies — Méthode de quantification des
concentrations dans l'air de noir de carbone et de silice
amorphe à l'échelle nanométrique dans un environnement
de fabrication industrielle contenant des mélanges de
poussières
1 Domaine d’application
Le présent document fournit des lignes directrices pour quantifier et identifier la concentration
3
(nombre de particules/cm ) de particules de noir de carbone et/ou de silice amorphe par taille, dans les
échantillons d’air prélevés dans un environnement de fabrication industrielle contenant des mélanges
de poussières.
La méthode est définie pour les échantillons d’air prélevés en utilisant un impacteur en cascade à basse
pression à détection électrique (ELPCI) sur un substrat de polycarbonate de 25 mm. La méthode décrite
convient pour effectuer des prélèvements dans des environnements de fabrication où l’atmosphère
générale contient une grande diversité de types de particules. Cette méthode n’est applicable qu’aux
environnements dont les particules contribuant aux aérosols sont chimiquement et physiquement
distinctes, ou lorsque les matériaux parasites peuvent être contrôlés (particules provenant de moteurs
diesel, par exemple). Bien que le présent document se limite à la description de méthodes associées
à l’impacteur en cascade à basse pression à détection électrique, d’autres méthodes de prélèvement
pourraient également convenir.
Les échantillons recueillis avec l’impacteur en cascade à basse pression à détection électrique sont
analysés par MET et EDS afin de déterminer, respectivement, la morphologie des particules et la
composition élémentaire, pour pouvoir identifier les particules par type. Ces informations sont ensuite
utilisées, conjointement avec la concentration de particules par plage granulométrique, déterminée
à l’aide de l’impacteur en cascade à basse pression à détection électrique, afin de déterminer la
concentration des matériaux étudiés en fonction de leur taille.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s'applique (y compris les
éventuels amendements).
ISO 10312, Air ambiant — Détermination des fibres d’amiante — Méthode de microscopie électronique à
transmission directe
ISO 4225, Qualité de l’air — Aspects généraux — Vocabulaire
ISO/TS 80004-1, Nanotechnologies — Vocabulaire — Partie 1: Termes "coeur"
ISO 22309, Analyse par microfaisceaux — Analyse élémentaire quantitative par spectrométrie à sélection
d'énergie (EDS) des éléments ayant un numéro atomique de 11 (Na) ou plus
ISO/TS 10798, Nanotechnologies — Caractérisation des nanotubes de carbone à simple paroi par
microscopie électronique à balayage et spectroscopie à dispersion d'énergie
© ISO 2019 – Tous droits réservés 1

---------------------- Page: 7 ----------------------
ISO/TS 21361:2019(F)

3 Termes et définitions
Pour les besoins du présent document, les termes et définitions de l’ISO 4225 et l’ISO/TS 80004‐1 ainsi
que les suivants, s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https: //www .iso .org/obp
— IEC Electropedia: disponible à l’adresse http: //www .electropedia .org/
3.1
diamètre aérodynamique d’une particule
−3
diamètre d’une sphère ayant une masse volumique de 1 000 kg·m qui a la même vitesse de
sédimentation que la particule de forme irrégulière
3.2
impacteur en cascade
appareil qui prélève simultanément, par impact, des particules en les séparant en un certain nombre de
plages granulométriques en fonction de leurs paramètres d’inertie
3.3
diamètre de coupure
dimension des particules à partir de laquelle le rendement d’un séparateur devient inférieur à une
valeur spécifiée dans des conditions données
3.4
échelle nanométrique
échelle de longueur s’étendant approximativement de 1 nm à 100 nm
3.5
nanomatériau
matériau ayant une dimension externe à l’échelle nanométrique ou ayant une structure interne ou une
structure de surface à l’échelle nanométrique
3.6
particule
élément de matière isolé possédant des limites physiques définies
3.7
durée d’échantillonnage
intervalle de temps pendant lequel est prélevé un seul échantillon
4 Principe
Le prélèvement d’air est réalisé à l’aide d’un impacteur en cascade à basse pression à détection
électrique (ELPCI). L’ELPCI est un impacteur en cascade à plusieurs étages représentant différentes
classes granulométriques qui se distinguent en fonction du diamètre aérodynamique. L’impacteur en
cascade est raccordé à une pompe à vide qui aspire l’air (et donc les particules qui y sont en suspension)
dans l’impacteur. Lorsque les particules entrent dans l’impacteur en cascade, elles sont chargées puis
réparties par taille aérodynamique entre les différents étages. Dès qu’elles viennent en contact avec
la surface de l’étage correspondant à leur taille, elles transmettent un courant électrique à l’ELPCI. Ce
courant électrique est ensuite converti en un nombre de particules pour l’étage concerné, permettant
ainsi à l’ELPCI d’effectuer un comptage de particules en temps réel. Ce comptage des particules est
3
exprimé en nombre de particules par cm d’air. En plus de la fonction de comptage de particules,
l’ELPCI permet également de recueillir des échantillons à chaque étage, en utilisant un substrat de
polycarbonate de 25 mm.
2 © ISO 2019 – Tous droits réservés

---------------------- Page: 8 ----------------------
ISO/TS 21361:2019(F)

Une fois le prélèvement d’air achevé, ces substrats sont analysés par MET afin d’identifier les particules
présentes à chaque étage par leur morphologie, et grâce au couplage avec l’EDS, les compositions
élémentaires des particules sont identifiées à chaque étage. Un minimum de 100 particules distinctes
par étage sont analysées par MET‐EDS afin d’identifier le type de particule, sur la base de la signature
chimique des particules. Le noir de carbone, principalement constitué de carbone élémentaire, induit
un puissant signal de carbone (et aucun autre signal) sur l’EDS, alors que la silice (SiO ) produit un
2
puissant signal de silicium et d’oxygène. Ces profils sont utilisés pour déterminer si les particules sont
du noir de carbone ou de la silice amorphe. Lorsque l’échantillon contient des matériaux parasites
potentiels tels que de la suie (pour le noir de carbone) ou de la silice cristalline (pour la silice amorphe),
il faut se référer à la morphologie des particules et/ou au diagramme de diffraction pour identifier les
particules. La morphologie est le principal attribut qui distingue le noir de carbone de la suie, alors que
la morphologie et la diffraction peuvent servir à différentier la silice cristalline de la silice amorphe. Par
ailleurs, il est possible d’effectuer une évaluation par MET en comparant la morphologie des matériaux
de base (par exemple le noir de carbone ou la silice amorphe), afin de s’assurer que le type de particule a
été correctement déterminé. La proportion relative de particules (par exemple le nombre de particules
par type sur un total de 100 particules identifiées par fraction granulométrique) identifiées par type
de particule (noir de carbone, silice amorphe ou autre) constitue le principal résultat de cette analyse.
Pour déterminer la concentration dans l’air des matériaux étudiés (noir de carbone ou silice amorphe,
par exemple), la proportion de particules identifiées par type est multipliée par le nombre total de
particules dans chaque classe granulométrique déterminée pendant le prélèvement d’air en temps
réel. Le résultat de cette analyse est la concentration dans l’air de chaque type de matériau par taille,
3
exprimée en nombre de particules/cm .
Bien que la méthode décrite dans le présent document soit spécifiquement axée sur l’analyse du noir
de carbone et de la silice amorphe, cette méthodologie peut être transposée à d’autres matériaux, sous
réserve que ces derniers induisent un signal unique en EDS et/ou qu’il soit possible de les distinguer par
leur morphologie en MET.
5 Abréviations
EDS Spectrométrie à sélection d’énergie
ELPCI Impacteur en cascade à basse pression à détection électrique
HEPA Arrêt des particules à haute efficacité
LDD Limite de détection
PM10 Particules en suspension dans l’air dont le diamètre aérodynamique est inférieur à 10 μm
MEB Microscopie électronique à balayage
MET Microscopie électronique à transmission
6 Réactifs
Pendant l’analyse, utiliser uniquement des réactifs de qualité analytique reconnue. Tous les réactifs
figurant dans la liste ci‐dessous sont requis pour exécuter le transfert du contenu du substrat de
polycarbonate sur une grille de MET conformément à l’ISO 10312. Aucun autre réactif n’est requis pour
l’exécution de cette spécification.
AVERTISSEMENT — Utiliser les réactifs conformément aux règlementations appropriées en
matière d’hygiène et de sécurité.
© ISO 2019 – Tous droits réservés 3

---------------------- Page: 9 ----------------------
ISO/TS 21361:2019(F)

6.1 Eau, exempte de fibres.
Une alimentation en eau récemment distillée et exempte de fibres, ou une autre source d’eau exempte
de fibres et d’agents pyrogènes doit être utilisée.
6.2 Chloroforme, de qualité analytique.
Distillé dans un récipient en verre, conservé avec 1 % (V/V) d’éthanol; utilisé pour dissoudre le substrat
de polycarbonate.
6.3 1-Méthyl-2-pyrrolidone.
Utilisée pour dissoudre le substrat de polycarbonate.
6.4 Diméthylformamide.
Utilisé pour dissoudre le substrat de polycarbonate.
6.5 Acide acétique glacial.
Utilisé pour dissoudre le substrat de polycarbonate.
6.6 Acétone.
Utilisée pour dissoudre le substrat de polycarbonate.
7 Appareillage
7.1 Prélèvement d’air — Équipement et consommables
7.1.1 Impacteur en cascade à basse pression à détection électrique (ELPCI)
Pour le prélèvement des échantillons d’air, il convient d’utiliser un impacteur en cascade à basse
pression à détection électrique, constitué d’un minimum de 14 classes granulométriques. Parmi les
classes granulométriques, il est recommandé qu’au moins 3 soient à l’échelle nanométrique, c’est-à-dire
à moins de 100 nm. Il convient d’utiliser l’ELPCI conformément aux instructions du fabricant.
Le Tableau 1 présente un exemple de capacité de mesure d’un impacteur en cascade à basse pression à
détection électrique du commerce, fonctionnant à un débit de 10 l/min.
Tableau 1 — Plage de mesure d’un impacteur en cascade à basse pression à détection électrique
du commerce (Dekati, 2011)
D50 % Di Nombre Nombre Conc. en masse Conc. en masse
  min. max. min. max.
3 3 3 3
nm nm 1/cm 1/cm µg/m µg/m
10 000 Non disponible Non disponible Non disponible Non disponible Non disponible
6 800 8 200 0,1 2,40E+04 30 10 000
4 400 5 500 0,1 2,40E+04 10 3 000
2 500 3 300 0,15 5,40E+04 3 1 000
1 600 2 000 0,3 1,10E+05 1,4 450
1 000 1 300 0,5 1,90E+05 0,7 210
640 800 1 3,50E+05 0,3 100
D50 % = Diamètre aérodynamique de coupure pour un rendement de 50 %; Di = Diamètre aérodynamique géométrique
moyen de l’étage.
4 © ISO 2019 – Tous droits réservés

---------------------- Page: 10 ----------------------
ISO/TS 21361:2019(F)

Tableau 1 (suite)
D50 % Di Nombre Nombre Conc. en masse Conc. en masse
  min. max. min. max.
3 3 3 3
nm nm 1/cm 1/cm µg/m µg/m
400 510 2 6,40E+05 0,1 50
260 320 3 1,20E+06 0,07 20
170 210 5 2,10E+06 0,03 10
108 140 10 3,70E+06 0,02 5
60 80 20 7,30E+06 0,005 2
30 42 50 1,70E+07 0,002 0,5
17 22 100 3,40E+07 0,001 0,25
6 1 250 8,30+07 0,000 4 0,13
D50 % = Diamètre aérodynamique de coupure pour un rendement de 50 %; Di = Diamètre aérodynamique géométrique
moyen de l’étage.
7.1.2 Limite de détection
Sur la base du tableau qui précède et du débit volumique at
...

Questions, Comments and Discussion